• Title/Summary/Keyword: Energy Management System

Search Result 2,244, Processing Time 0.034 seconds

A proposal of total energy operating system development using spatial information visualization and energy monitoring - Case study on design of total operation system in Sejong city - (건물 에너지 모니터링과 공간정보 시각화를 이용한 에너지 통합 운영시스템 개발 방안 제안 - 세종시 첫마을 공공건물을 대상으로 한 시스템 구축 사례 -)

  • Kwon, KeeJung;Lee, DongHwan;Cha, KiChun;Park, SeungHee
    • Journal of KIBIM
    • /
    • v.4 no.1
    • /
    • pp.8-12
    • /
    • 2014
  • This research and project is going on the Korean government. The objective of project is that developing total energy management solution. So, this paper is going to introduce a proposal that energy total operating system development using spatial information visualization and energy monitoring. It could efficiently operate the building energy wirelessly controling cooling/heating, lighting, air-conditioning and geothermal system. The metering data is collected to total database. The data is linked to BAS gateway, which is connected the device by the standard protocol.

Study on the Suitability of Bioenergy System from Food waste for Building Load (음식물쓰레기 바이오에너지 이용시스템의 건축물 적용성에 관한 연구)

  • Kang, Bum-Sung;Choi, Mi-Young;Ko, Myeong-Jin;Kim, Yong-Shik
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.132-140
    • /
    • 2008
  • Recently, the whole world is concerned about the saving energy and protective environment, so interest is increasing in new and renewable energy. Specially the Bioenergy continuity is possible, the research is advanced by the energy which it contributes in environmental conservation. From the research which it sees consequently it investigates about co-generation system of domestic bio-energy, it is used to analyze the electricity and heat energy of buildings that Energy Consumption Survey of Korea Energy Management Corporation and food waste generation quantity of Ministry of Environment. This paper is analyzed that application of food waste Biogas plant system.

  • PDF

Analyzing the Differential Views between the Designers and the Users on Certification Assessment Criteria of the G-SEED System - Focused on Certification Assessment Criteria for Apartment Buildings - (녹색건축 인증제도 평가항목에 대한 설계 실무자 및 사용자 의식 차이 분석 - 공동주택 인증 평가항목을 중심으로 -)

  • Choi, Yeo-Jin
    • KIEAE Journal
    • /
    • v.15 no.6
    • /
    • pp.87-92
    • /
    • 2015
  • Purpose: The green building certification system in Korea was introduced in 2002 and developed as an improvement version of the G-SEED(Green Standard for Energy and Environmental Design) system in 2013. This study conducts surveys targeting architectural designers and users on significance of certification assessment criteria for apartment buildings on the G-SEED system and examines the differential views between the two groups on assessment criteria. Method: First, The AHP(Analytic Hierarchy Process) method was used to find importance of assessment criteria and then the importances were compared with weighted points on the certification standard. Second, the t-test was used to investigate differential views between designer and user groups on certification assessment criteria based on drawn importances. Result: (1) While designer group considered land use and transportation, energy and environmental pollution, and water circulation management as more important, user group did material and resource, maintenance management, ecological environment, and indoor environment as more important. (2) Based on t-test results, sustainable energy, water circulation system, site management, habitat, acoustical environment, and light environment were found to be different on importance between the two groups.

A Design of Air Compressor Remote Control System Using USN Technology (USN 기술을 이용한 공기압축기 원격관리 시스템 설계)

  • Hwang, Moon-Young
    • Korean Journal of Artificial Intelligence
    • /
    • v.6 no.1
    • /
    • pp.1-10
    • /
    • 2018
  • Compressed Air is an important energy source used in most factories nowadays. The automation trend using air compressor has been gradually increasing with the interest of the 4th industry in recent years. With the air compressor system, it is possible to construct the device at low cost and easily achieve automation and energy saving. In addition, With trend of FA, miniaturation and light weight manufacturing trend expand their use in the electronics, medical, and food sectors. Research method is to design the technology for the remote control of the following information as USN base. Development of flexible sensing module from real time observation module for fusion of IT technology in compressed air systems, design and manufacture of flexible sensing module, and realiability assessment. Design of real-time integrated management system for observation data of compressed air system - Ability to process observation data measured in real time into pre-processing and analysis data. This study expects unconventionally decreasing effect of energy cost that takes up 60~70% of air compressor layout and operation and maintenance management cost through USN(Ubiquitous Sensor Network) technology by using optimum operational condition from real time observation module. In addition, by preventing maintenance cost from malfunction of air compressor beforehand, maintenance cost is anticipated to cut back.

Performance of Fuel Cell System for Medium Duty Truck by Cooling System Configuration (상용차용 고분자 전해질 연료전지 냉각시스템 배열에 따른 성능 특성)

  • WOO, JONGBIN;KIM, YOUNGHYEON;YU, SANGSEOK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.4
    • /
    • pp.236-244
    • /
    • 2021
  • Fuel cell systems for medium duty truck require high power demands under driving. Since high power demands results in significant heat generation, thermal management is crucial for the performance and durability of medium duty truck. Therefore, various configurations of dual stacks with cooling systems are investigated to understand appropriate thermal management conditions. The simulation model consists of a dynamic fuel cell stack model, a cooling system model equipped with a controller, and the mounted controller applies a feedback controller to control the operating temperature. Also, In order to minimize parasitic power, the comparison of the cooling systems involved in the arrangement was divided into three case. As a result, this study compares the reaction of fuel cells to the placement of the cooling system under a variety of load conditions to find the best placement method.

Power Stabilization Catenary line ESS of KTX High Speed Train (KTX 고속전철 급전선로의 ESS를 통한 전원안정화)

  • Pyo, Se-Wan;Lee, Eun-Kyu;Kim, Sang-Hoon
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2021-2030
    • /
    • 2011
  • This thesis paper is on the management of Energy Storage System for the catenary source stabilization of KTX's high-speed train section. It is the algorism that is to utilize on the voltage drop at the end and peak power suppression of the substation by supplying from the end, compensating consuming energy when the KTX retrogresses, by installing Energy Storage System at the end of the substation where is the section post. The algorism which this thesis is to utilize is verified through the catenary voltage modeling and simulation of the power conversion system, and the system validity of the Korail's Yongjeong section post which is currently in management is in the application review phase.

  • PDF

A Frequency Selection Algorithm for Power Consumption Minimization of Processor in Mobile System (이동형 시스템에서 프로세서의 전력 소모 최소화를 위한 주파수 선택 알고리즘)

  • Kim, Jae Jin;Kang, Jin Gu;Hur, Hwa Ra;Yun, Choong Mo
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.4 no.1
    • /
    • pp.9-16
    • /
    • 2008
  • This paper presents a frequency selection algorithm for minimization power consumption of processor in Mobile System. The proposed algorithm has processor designed low power processor using clock gating method. Clock gating method has improved the power dissipation by control main clock through the bus which is embedded clock block applying the method of clock gating. Proposed method has compared power consumption considered the dynamic power for processor, selected frequency has considered energy gain and energy consumption for designed processor. Or reduced power consumption with decreased processor speed using slack time. This technique has improved the life time of the mobile systems by clock gating method, considered energy and using slack time. As an results, the proposed algorithm reduce average power saving up to 4% comparing to not apply processor in mobile system.

Intelligent Energy Harvesting Power Management and Advanced Energy Storage System (지능형 에너지 저장시스템과 ESS 개발을 위한 소재 및 공정 기술)

  • Heo, Kwan-Jun;Kim, Sung-Jin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.7
    • /
    • pp.417-427
    • /
    • 2014
  • Renewable energy sources such as solar, wind and hydro provides utilizing renewable power and reduce the using fossil fuels. On the other hand, it is too critical to apply power system due to the intermittent nature of renewable energy sources, the continuous fluctuations of the power load, and the storage with high energy density. Energy storage system, including pumped-hydroelectric energy storage, compressed-air energy storage, superconducting magnetic energy storage, and electrochemical devices like batteries, supercapacitors and others have shown that solve some of the challenges. In this paper, we review the current state of applications of energy storage systems, and atomic layer deposition technology, graphene materials on the energy storage systems and processes.

Cell Balancing to Improve Safety and Performance against Unbalanced Voltage between Secondary Battery Cells (2차전지 셀(Cell) 간의 불균형 전압 발생에 대한 안전성 및 성능향상을 위한 셀 밸런싱(Cell Balancing))

  • Yongho Yoon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.24 no.4
    • /
    • pp.141-146
    • /
    • 2024
  • Energy Storage System(ESS) have been developed to store and efficiently utilize energy, transitioning from the traditional method of producing and consuming energy immediately via fossil fuels and generators. With the advancement of this technology, Battery Management System(BMS) that manage Li-ion batteries at the cell level play a crucial role in enhancing battery performance, lifespan, and safety. Among the BMS functions, cell balancing, which aligns the imbalanced voltages of cells, is essential for optimizing capacity in devices like ESS. It ensures all cells maintain the same voltage and capacity, improving performance and output stability. Therefore, this paper examines the operational characteristics of the cell balancing method within BMS when charging an imbalanced Li-ion battery.

A Research for Agentless Monitoring Application of Energy Consumption Analysis in a Data Center (데이터센터의 효율적인 에너지소비분석을 위한 에이전트리스 모니터링 애플리케이션에 관한 연구)

  • Lee, Yunho;Jung, Hyedong;Lim, Hojung;Kang, Jeonghoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.896-899
    • /
    • 2016
  • Server management and power management are important to operate a data center stably and efficiently. By this paper, we introduce an web based application that is able to monitor and visualize energy consumption, help to energy consumption analysis of a data center due to provide server monitoring information such as temperatures for server, status of each device, power status using server management interfaces and power management modules in data center, also suggest the methods to implement them. This application takes advantage of IPMI which is server management standard interfaces and server management technology in manufacturer's individual way so it can do integrated monitoring for heterogeneous severs, and there is little monitoring load inside of server system because it doesn't need to install agent program for monitoring target system, and it can be used successfully to energy consumption analysis, server management in a data center due to realtime provided energy consumption and monitoring information.

  • PDF