• Title/Summary/Keyword: Energy Fluence

Search Result 154, Processing Time 0.031 seconds

Laser application in 3-D micromachining (레이져를 이용한 3차원 형상가공에 관한 연구)

  • 윤경구;이성국;황경현
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.75-78
    • /
    • 1995
  • This paper presents the feasibility of laser ablation process in 3-D micro machining of MEMS (micro Electro Mechanical System)parts. The micro machining characteristics of polymer(Energy fluence, pulse repetition rate, number of pulse, ablation rate)are investigated and 3-D micro machined samples are demonstrated.

  • PDF

Medical Laser (의료용 Laser)

  • 김덕원
    • Korean Journal of Optics and Photonics
    • /
    • v.1 no.1
    • /
    • pp.107-113
    • /
    • 1990
  • Characteristics and applications of three major types of lasers are discussed. They are chemical-metabolic, thermal destructive, and nonthermal mechanical lasers. The thermal destructive lasers ($CO_2$, Argon, and Nd:YAG) are especially explained in detail with regard to energy density, wavelength, fluence, stage of thermal destruction, and advantages of laser surgery. Excimer and Q-swiched lasers are discussed as nonthermal mechanical ones. Delivery system, optical fiber and articulated arm, is also discussed. Finally, recent advancements of medical laser are included in the conclusion.

  • PDF

Preparation of photoresist-derived carbon micropatterns by proton ion beam lithography and pyrolysis

  • Nam, Hui-Gyun;Jung, Jin-Mook;Hwang, In-Tae;Shin, Junhwa;Jung, Chang-Hee;Choi, Jae-Hak
    • Carbon letters
    • /
    • v.24
    • /
    • pp.55-61
    • /
    • 2017
  • Carbon micropatterns (CMs) were fabricated from a negative-type SU-8 photoresist by proton ion beam lithography and pyrolysis. Well-defined negative-type SU-8 micropatterns were formed by proton ion beam lithography at the optimized fluence of $1{\times}10^{15}ions\;cm^{-2}$ and then pyrolyzed to form CMs. The crosslinked network structures formed by proton irradiation were converted to pseudo-graphitic structures by pyrolysis. The fabricated CMs showed a good electrical conductivity of $1.58{\times}10^2S\;cm^{-1}$ and a very low surface roughness.

Ar-GCIB를 이용하여 ToF-SIMS에서 얻은 쥐의 뇌조직 이미지

  • Son, Hyeon-Gyeong;Lee, Tae-Geol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.378.1-378.1
    • /
    • 2016
  • 나노바이오연구분야에서 ToF-SIMS를 이용하여 lipid와 metabolite같은 저 분자의 생체물질을 측정하는데 널리 이용되어 왔다. 최근에는 고 분자량의 생체물질을 측정하기 위해서 C60, water cluster, argon cluster등의 다양한 종류의 클러스터 이온빔들이 개발되어 왔다. [1,2] 하지만 tissue샘플을 클러스터 이온빔을 이용하여 분석한 결과에서도 m/z 1500이상의 고분자를 측정한 결과는 거의 없다. 바이오샘플의 charging을 상쇄하기위해 low energy electron beam (~20 eV)을 사용하는데, low energy electron beam이 샘플에 damage를 주기 때문이다. [3] 본 연구에서는 electron fluence (electrons/cm2)가 증가함에 따라 PC(16:0/18:1(9Z)와 Ganglioside GM1의 intensity가 감소함을 알았고, low energy electron beam에 의해 생체 물질이 damage를 받을 수 있음을 확인하였다. 따라서 tissue 샘플을 SUS기판에 샘플링하고 Ar-GCIB를 이용하면 charging없이 tissue imaging을 성공적으로 수행할 수 있고, m/z 2000이상의 고 분자량의 생체물질을 측정할 수 있음을 확인하였다.

  • PDF

Turn-off time improvement by fast neutron irradiation on pnp Si Bipolar Junction Transistor

  • Ahn, Sung Ho;Sun, Gwang Min;Baek, Hani
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.501-506
    • /
    • 2022
  • Long turn-off time limits high frequency operation of Bipolar Junction Transistors (BJTs). Turn-off time decreases with increases in the recombination rate of minority carriers at switching transients. Fast neutron irradiation on a Si BJT incurs lattice damages owing to the displacement of silicon atoms. The lattice damages increase the recombination rate of injected holes with electrons, and decrease the hole lifetime in the base region of pnp Si BJT. Fast neutrons generated from a beryllium target with 30 MeV protons by an MC-50 cyclotron were irradiated onto pnp Si BJTs in experiment. The experimental results show that the turn-off time, including the storage time and fall time, decreases with increases in fast neutron fluence. Additionally, it is confirmed that the base current increases, and the collector current and base-to-collector current amplification ratio decrease due to fast neutron irradiation.

SHIELDING DESIGN ANALYSES FOR SMART CORE WITH 49-CEDM

  • Kim, Kyo-Youn;Kim, Ha-Yong;Cho, Byung-Oh;Zee, Sung-Quun;Chang, Moon-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.225-229
    • /
    • 2001
  • In Korea, an advanced reactor system of 330MWt power called SMART (System integrated Modular Advanced ReacTor) is being developed by KAERI to supply energy for seawater desalination as well as electricity generation. A shielding design of the SMART core with 49 CEDM is established by a two-dimensional discrete ordinates radiation transport analyses. The DORT two-dimensional discrete ordinates transport code is used to evaluate the SMART shielding designs. Three axial regions represent the SMART reactor assembly, each of which is modeled in the R-Z geometry. The BUGLE-96 library is used in the analyses, which consists of 47 neutron and 20 gamma energy groups. The results indicate that the maximum neutron fluence at the bottom of reactor vessel is $5.89 {\times} 10^{17}\;n/cm^2$ and that on the radial surface of reactor vessel is $4.49 {\times} 10^[16}\;n/cm^2$. These results meet the requirement, $1.0 {\times} 10^{20}\;n/cm^2$, in 10 CFR 50.61 and the integrity of SMART reactor vessel during the lifetime of the reactor is confirmed.

  • PDF

SPECTRUM WEIGHTED RESPONSES OF SEVERAL DETECTORS IN MIXED FIELDS OF FAST AND THERMAL NEUTRONS

  • Kim, Sang In;Chang, Insu;Kim, Bong Hwan;Kim, Jang Lyul;Lee, Jung Il
    • Nuclear Engineering and Technology
    • /
    • v.46 no.2
    • /
    • pp.273-280
    • /
    • 2014
  • The spectrum weighted responses of various detectors were calculated to provide guidance on the proper selection and use of survey instruments on the basis of their energy response characteristics on the neutron fields. To yield the spectrum weighted response, the detector response functions of 17 neutron-measuring devices were numerically folded with each of the produced calibration neutron spectra through the in-house developed software 'K-SWR'. The detectors' response functions were taken from the IAEA Technical Reports Series No. 403 (TRS-403). The reference neutron fields of 21 kinds with 2 spectra groups with different proportions of thermal and fast neutrons have been produced using neutrons from the $^{241}Am$-Be sources held in a graphite pile, a bare $^{241}Am$-Be source, and a DT neutron generator. Fluence-average energy ($E_{ave}$) varied from 3.8 MeV to 16.9 MeV, and the ambient-dose-equivalent rate [$H^*(10)/h$] varied from 0.99 to 16.5 mSv/h.

The Dependence of the Wedge Factor with the Variation of High Energy Photon Beam Fluences (고에너지 광자선의 선속 변화에 따른 쐬기인자의 의존성)

  • 오영기;윤상모;김재철;박인규;김성규
    • Progress in Medical Physics
    • /
    • v.11 no.1
    • /
    • pp.1-18
    • /
    • 2000
  • For wedged photon beams, the variation of the wedge factor with field size was reported by several authors. However, until now such variation with field size had not been explained quantitatively. Therefore, the variation of the wedge factor was investigated by measuring outputs with field sizes increasing from 4 cm $\times$ 4 cm to 25 cm $\times$ 25 cm for open and wedged 6 and 10MV X-ray beams. The relative outputs for wedged fields to 10 cm $\times$ 10 cm have been obtained. The results show the Increase of the wedge factor caused by the change in fluence of high energy Photon beam with field size, up to 8.0% for KD77-6MV X-ray beam. This increase could be explained as a linear function of the irradiated wedge volume except small field size up to about 10 cm. In the cases of the narrow rectangular beam parallel to the wedge direction, the wedge factor decreases slightly with increasing field size up to about 10-15 cm due to a relatively reduced photon fluence from the change of the wedge thickness. We could explain the causes of a wedge factor variation with field size as the fluences of primary photon passed throughout the wedge, contributing to the dose at the central beam axis and that the fluences were affected by the gradient of the wedge with the change of field size. For clinical use, the formula developed to describe the wedge factor variation with field size has been corrected.

  • PDF

Harmonic frequency analysts of acoustic Barkhausen noise on neutron irradiated material (중성자조사재료의 acoustic Barkhausen noise의 harmonic frequency 분석)

  • Sim Cheul-Muu;Park Seung-Sik;Koo Kil-Moo;Sohn Jae-Min;Lee Chang-Hee
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.401-406
    • /
    • 1999
  • In relation to a non-destructive evaluation of irradiation damages of micro-structure interstitial, void and dislocation, the changes in the hysteresis loop, Barkhausen noise amplitude and the harmonics frequency due to a neutron irradiation were measured and evaluated. The Mn-Mo-Ni low alloy steel of RPV was irradiated to a neutron fluence of $2.3\times10^{19}\;n/cm^2\;(E\geq1\;MeV)\;at\;288^{\circ}C$. The saturation magnetization of neutron irradiated metal did not change. The neutron irradiation caused the coercivity to increase, whereas susceptibility to decrease. The amplitude of Barkhausen noise parameters associated with the domain wall motion were decreased by a neutron irradiation. The spectrum of Barkhausen noise is analysed with an applied frequency of 4 Hz and 8 Hz, sampling time of $50\;{\mu}sec\;and\;20\;{\mu}sec$. The harmonic frequency shows 4 Hz, 8 Hz, 12 Hz; and 16 Hz reflected from an unirradiated specimen. On the contrary, the harmonic frequency disappeared on the irradiated specimen.

  • PDF

The Analysis of Spectrum on the Barkhausen Noise of Hysteresis Loops on Neutron Irradiated Material

  • Sim, Cheul-Muu;Chang, Kee-Ok;Park, Kook-Nam;Cho, Man-Soon;Park, Chang-Oong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.1E
    • /
    • pp.7-12
    • /
    • 1999
  • In relation to a non-destructive evaluation of irradiation damages, the changes in the hysteresis loop and Barkhausen noise amplitude and the harmonics frequency due to a neutron irradiation were measured and evaluated. The Mn-Mo-Ni low alloy steel of RPV was irradiated to a neutron fluence of 2.3 ×10/sup 19/ n/㎠ (E ≥1 MeV) at 288℃. The saturation magnetization of neutron irradiated metal did not change. The neutron irradiation caused the coercivity to increase, whereas susceptibility to decrease. The amplitude of Barkhausen noise parameters associated with the domain wall motion were decreased by a neutron irradiation. The spectrum of Barkhausen noise is analysed with an applied frequency of 4 Hz and 8 Hz, sampling time of 50 μ sec and 20 μ sec. The harmonic frequency shows 4 Hz, 8 Hz, 12 Hz and 16 Hz reflected from an unirradiated specimen. On the contrary, the harmonic frequency disappeared on the irradiated specimen. In addition to the amplitude, the harmonic frequency of Barkhausen noise is taken into accounts as a promising tool for monitoring the irradiation induced degradation of the reactor materials such as a SA508 of PWR-RPV steel and a Zr₄ of HANARO-CNH.

  • PDF