• Title/Summary/Keyword: Energy Efficiency Improvement

Search Result 1,002, Processing Time 0.03 seconds

Study on the Evaluation of Uncertainty for the Efficiency of 0.75[kW] Class Three Phase Induction Motor (0.75[kW]급 삼상유도전동기 효율의 불확도 평가에 관한 연구)

  • Jun, Hee-Deuk;Park, Han-Seok;Kim, Dea-Kyong;Woo, Kyung-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.4
    • /
    • pp.653-659
    • /
    • 2015
  • In the last few years, the regulations for efficiency grade of the three phase induction motor are internationally being discussed and upgraded for the protection of environment and energy saving. So the efficiency improvement and the reliable test result are essential to determine the premium grade three phase induction motor. While a study on developing the efficiency motor is active, there is little research about the guarantee for efficiency. So in this paper, the dispersion characteristic of the efficiency is studied using uncertainty theory for the three phase induction motor to improve the reliability of efficiency. The values such as input voltage, current, speed, torque were obtained by loss separation method to evaluate the uncertainty. From the result, it was known that the important loss factor could affect the uncertainty is the stray loss.

Development of the IFC based IDF Converter for Energy Performance Assessment in the Early Design Phase (초기 설계단계 에너지 성능평가를 위한 IFC 기반 IDF 변환기 개발)

  • Kim, In-Han;Kim, Ji-Eun;Choi, Jung-Sik
    • Korean Journal of Computational Design and Engineering
    • /
    • v.16 no.2
    • /
    • pp.146-155
    • /
    • 2011
  • As the seriousness of environmental pollution being on a rise, a low carbon and environment-friendly design for energy efficiency has been issued. With respect to energy in the construction industry, an adoption of BIM which is possible for the various energy performance assessments in the early design phase has been actively working on. In the most cases of energy performance assessment, the data compatibility from the lack of standard software and format became a problem and the improvement for data compatibility system has been needed. This study is to develop the IFC based IDF converter as a middleware which connects between BIM software and energy analysis software. For the building energy performance assessment, Energy Plus and IFC are selected for the standard energy analysis software and its file format. Parameters are organized by steps and the integrated material library is built so it is trying to reduce the existing problem of energy software interface as much as possible. The development of IDF Converter will promote the spread of related fields with increasing the BIM standard and the utilization of energy performance assessment.

Design of CIM(Common Information Model) Profile for Smart City Energy Monitoring (스마트시티 에너지 감시를 위한 CIM(Common Information Model) 프로파일 설계)

  • Youngil, Kim;Changhun, Chae;Yeri, Kim;Jihoon, Lee
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.2
    • /
    • pp.127-135
    • /
    • 2022
  • With the advent of high technologies such as the 4th Industrial Revolution and artificial intelligence and big data, efforts are being made to solve urban problems and improve the quality of life by applying new technologies in the smart city field. In addition, as carbon neutrality has emerged as an important issue due to global warming, smart city energy platform technologies such as urban energy management, efficiency improvement, and carbon reduction are in the spotlight. In order to effectively manage urban energy, energy resource information such as electricity, water, gas, hot water, heating, etc. must be collected from the management system of various energy utilities and managed on the central platform. The centrally integrated data is delivered to external city management systems that require city energy information through an energy platform. This study developed a CIM profile for smart city energy monitoring required to provide energy data to external systems. Electric data model were designed using the CIM class of IEC 61970, and water, gas, and heat data model were designed in compliance with the UML-based design ideas of IEC 61970.

Performance Analysis of ILEACH and LEACH Protocols for Wireless Sensor Networks

  • Miah, Md. Sipon;Koo, Insoo
    • Journal of information and communication convergence engineering
    • /
    • v.10 no.4
    • /
    • pp.384-389
    • /
    • 2012
  • In this paper, we examine the problems of the low energy adaptive clustering hierarchy (LEACH) protocol and present ideas for improvement by selecting the cluster head node. The main problem with LEACH lies in the random selection of cluster heads. There exists a probability that the formed cluster heads are unbalanced and may remain in one part of the network, which makes some part of the network unreachable. In this paper, we present a new version of the LEACH protocol called the improved LEACH (ILEACH) protocol, which a cluster head is selected based on its ratio between the current energy level and an initial energy level, and multiplies by the root square of its number of neighbor nodes. The simulation results show that the proposed ILEACH increases the energy efficiency and network lifetime.

The Performance Field-Application of Natural Ventilation System (자연환기시스템의 현장 적용성 평가-열환경,에너지부분)

  • Choi, Dong-Hyuk;Choi, Gyoung-Seok;Kang, Jae-Sik;Lee, Seung-Eon
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.689-694
    • /
    • 2009
  • On account of Indoor Air Quality(IAQ) deterioration by reason of high isulation and air tightness for energy saving, absence of energy efficiency ventilation system development that can be domestic existing window system, the cost increase and the energy addition loss by mechanical ventilation for IAQ improvement the ventilation obligation making design standard was prepared by a social and technical background and the necessity. In this study, open module type natural ventilation window system for energy saving included a fixed and continuous quantity ventilation was developed. The purpose that indoor thermal comfort environment evaluate of indoor resident.

  • PDF

A Robust Transport Protocol Based on Intra-Cluster Node Density for Wireless Sensor Networks (무선 센서 네트워크를 위한 클러스터 내 노드 밀도 기반 트랜스포트 프로토콜)

  • Baek, Cheolheon;Moh, Sangman
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.10 no.6
    • /
    • pp.381-390
    • /
    • 2015
  • The efficient design of a transport protocol contributes to energy conservation as well as performance improvement in wireless sensor networks (WSNs). In this paper, a node-density-aware transport protocol (NDTP) for intra-cluster transmissions in WSNs for monitoring physical attributes is proposed, which takes node density into account to mitigate congestion in intra-cluster transmissions. In the proposed NDTP, the maximum active time and queue length of cluster heads are restricted to reduce energy consumption. This is mainly because cluster heads do more works and consume more energy than normal sensor nodes. According to the performance evaluation results, the proposed NDTP outperforms the conventional protocol remarkably in terms of network lifetime, congestion frequency, and packet error rate.

Green New Deal Project and Low Carbon, Green Growth Strategy (녹색뉴딜사업 및 저탄소 녹색성장 전략)

  • Lee, Sun
    • Journal of the Korean Professional Engineers Association
    • /
    • v.42 no.2
    • /
    • pp.41-48
    • /
    • 2009
  • The Government declared 'Low-Carbon Green Growth' as the new national vision for future development to improve economic growth and quality of life through higher energy efficiency, less energy consumption, wider use of renewable energy, etc. Korea can no longer delay participating in international efforts against global warming by reducing carbon dioxide and other greenhouse gas emissions. Thus low-carbon green growth is not a matter of choice, and it becomes indispensible to sustaining the nation's economic development. The Government is determined to take the initiative in speeding up economic recovery by carrying out the large scale investment projects such as the Korean version of a 'Green New Deal. The 49 trillion-won projects include river improvement, eco-friendly transportation networks, advanced information infrastructure, water resources & dam construction, green cars & clean energy development, etc. which will create nearly one million new jobs over the next four years.

  • PDF

Analysis on the Ventilation Rate of Express Bus according to the Geometry of Vent (고속버스의 환기구 형태에 따른 환기량 분석)

  • Shin, In-Hwaw;Yoo, Ho-Chun
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.174-178
    • /
    • 2011
  • This paper deals with the free cooling system of express bus using natural energy source in order to improve the room air quality and save cooling energy. In an express bus, there are may passengers in unit area, requiring the improvement of air quality and giving higher energy saving efficiency. Particularly, the express buses running fast make it easy to take in outdoor air at a flow rate controllable with a damper mechanism. This paper proposes the analysis on the air flow achieved by a damper controlled vertically and horizontally in order not to deteriorate the ride comfort of the passengers.

  • PDF

Comparison & Analysis of Anti-Reflection Coatings for Crystalline Si Solar cells (결정질 실리콘 태양전지의 반사방지막 비교 분석)

  • Cho, Kyeong-Yeon;Lee, Ji-Hun;Lee, Soo-Hong;Lee, Kyu-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.221-222
    • /
    • 2008
  • In Crystalline Si solar cells, Anti-Reflection Coating is contribute to improvement in energy conversion efficiency due to decrease of optical loss and recombination owing to surface passivation. Porous Si is formed electrochemical etching that uses chemical solution and anodization etching. So It gives that advantage in rapid process time and without high cost equipment. In this paper, We compare Porous Si with $SiO_2$/SiNx ARC and analyze that by anti-reflection coating.

  • PDF

Radiation-Induced Graft Copolymerization of Acrylic Acid onto Polyester

  • Chang, Hoon-Sean;Kong, Young-Kun;Lee, Chong-Kwang;Park, Jae-Ho
    • Nuclear Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.65-74
    • /
    • 1977
  • The radiation-induced graft polymerization of acrylic acid onto polyester fabric was investigated with accelerated electron beams as ratiation source at high dose rates. Homopolymerization was suppressed by addition of cations which is known as homopolymerization inhibitor, but this practical advantage was obtained at the expense of grafting efficiency. The rate of grafting (%/sec) was proportional to the 0.82th power of dose rates over the range from 1.6$\times$10$^{6}$ to 10$\times$10$^{6}$ rad/sec. The grafted polyester fabric showed considerable improvement in moisture regain and antistatic properties.

  • PDF