• Title/Summary/Keyword: Energy Consumption Source

Search Result 491, Processing Time 0.027 seconds

A Study on the Various Light Source Radiation Conditions and use of LED Illumination for Plant Factory (식물공장 각종광원의 방사조건과 LED조명의 활용에 관한 연구)

  • Yoon, Cheol-Gu;Choi, Hong-Kyoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.10
    • /
    • pp.14-22
    • /
    • 2011
  • The artificial lights to be introduced for the plant factories is requiring the artificial light resources with minimizing the energy consumption to reduce the greenhouse gases which is a major cause of global warming, and maximizing the efficiency in photosynthesis effect light-wave range, in which the plants can be greatly grown and developed, and having the signal light-wave range for forming the light types. the best growing and developing environment for the plants has recently realized with utilizing the LED(Lighting Emitting Diode) lamps, as a environment-friendly green lamps, which can elevating the light efficiency with using only the specific light wave range. In this study, to provide the necessary lights for the full artificial light type of the plant factory, the following research/study and experiments has been conducting. experiments of the spectrum for each light sources, and LED, The intensity of illumination, Irradiance, Photosynthesis Photon Flux Density.

Power based Routing Scheme for Ubiquitous Sensor Networks (유비쿼터스 센서 네트워크에서의 전력 기반 라우팅기법)

  • Won, Jongho;Park, Hyung-Kun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.649-651
    • /
    • 2018
  • Since the ubiquitous sensor network is not connected to external power source and operated by its own battery, it is required to maximize the network life using the efficient energy utilization. In a conventional hop count based routing protocol, most sensor nodes are designed with a constant transmission power. In this paper, we propose a routing protocol that prolongs the network lifetime by balancing the power consumption among the nodes by controlling the transmit power according to the residual power of the nodes, and compared the performance of the proposed routing protocol through computer simulations.

  • PDF

Real-Time Communication of Periodic Messages on Wireless Sensor and Actor Networks (무선 센서-엑터 네트워크에서 주기적 메시지의 실시간 전송)

  • Ngo, Dao Quan;Lee, Sang-Jin;Kim, Myung-Kyun
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2008.06d
    • /
    • pp.291-296
    • /
    • 2008
  • Wireless network technologies are becoming more widely used in industrial environment. The industrial communication system requires a real-time delivery of messages. The sensors periodically senses the physical environment and wants to deliver the data in real-time to the sink. This paper proposes a real-time protocol for periodic messages on wireless sensor and actor networks to be used in industrial communications. The proposed protocol delivers the data message using the shortest path from the source and the nearest actor. The protocol considers the energy consumption by reducing the number of broadcast messages during flooding. We have evaluated the performance of the proposed protocol using QualNet simulator. The simulation results show that the data messages have been delivered in real-time and the number of broadcast messages is reduced from 90% to 35% compared the existing protocols.

  • PDF

Carbon Emission Evaluation of Tap Water (수돗물의 탄소 배출량 평가)

  • Kim, Jin-Keun;Jeon, Hong-Jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.4
    • /
    • pp.511-517
    • /
    • 2011
  • To evaluate carbon emission in water treatment processes, LCA (life cycle assessment) was applied to 8 multi-regional water treatment plants (WTPs) from intake to supply of tap water. Investigation of 8 WTPs revealed that average carbon emission for 1 $m^3$ of tap water was 221 g. Major carbon emission sources in water supply system were intake and supply processes. Meanwhile, mixing process was the main carbon emission source in unit water treatment processes. Carbon emission was proportional to the turbidity and COD of raw water. Intake of better raw water and minimization of energy consumption in unit processes are needed to reduce carbon emission in the WTPs. In addition, comparison of carbon emission among WTPs can be used as a parameter for optimization of operation and maintenance of water treatment processes.

Oxidation of Carbon Monoxide by Pseudomonas carboxydohydrogena (Pseudomonas carboxydohydrogena에 의한 일산화탄소의 산화)

  • ;Hegeman, George
    • Korean Journal of Microbiology
    • /
    • v.21 no.1
    • /
    • pp.27-35
    • /
    • 1983
  • The stoichiometry between the consumption of CO and $O_2$ and the production of $CO_2(2CO+O_2{\rightarrow}2CO_2)$) showed that Pseudomonas carboxydohydrogena grows as a typical aerobic CO oxidizer with CO. The optimal concentration of CO for growth was found to be 30% in gas mixture with air. The initial buffer concentration of the culture medium did not affect the growth of this bacterium. P. carboxydohydrogena is an obligate aerobe and dose not use nitrate as a terminal electron acceptor. The CO dehydrogenase is an inducible and soluble enzyme. The reaction rate and stability were maximal at pH7.5, and the Arrhenius plot revealed an activation energy of 37.7kJ/mol (9.0 Kcal/mol). The crude enzyme used methylene blue, thionin, and toluylene blue as electron acceptors for the oxidation of CO to $Co_2$ under anaerobic conditions. It was found that water must be the source of the second oxygen atom for CO oxidation.

  • PDF

The Effective Product Method of Biodiesel (바이오디젤의 효과적 생산방법)

  • Lim, Young-Kwan;Shin, Seong-Cheol;Yim, Eui-Soon;Song, Heung-Ok
    • Applied Chemistry for Engineering
    • /
    • v.19 no.2
    • /
    • pp.137-144
    • /
    • 2008
  • In these days, there has been increased focus on global warming and the exhaustion of resources caused by the heavy consumption of fossil resources. In order to resolve these problems, biomass is increasingly gaining international attention as a source of renewable energy. Biodiesel fuel produced by the transesterification of vegetable oils and animal fats is expected to be one of the eco-friendly biomass based alternatives to petrodiesel. This article reviews some of the research for effective of biodiesel production.

An Experimental Study on the Reduction of Diesel Emission Using Low Temperature Plasma Apparatus (저온 플라즈마 장치를 이용한 디젤기관의 유해배출물질 저감에 관한 실험적 연구)

  • 김홍석;원준희;정태용
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.5
    • /
    • pp.12-19
    • /
    • 2000
  • The increasing use of vehicles is causing air-pollution problems. Diesel vehicles are preferred to gasoline vehicles, because the diesel vehicles are superior to gasoline vehicles in terms of fuel consumption, durability, power and efficiency. But the emission reduction technologies for diesel vehicle are not developed well like those for gasoline vehicles. Moreover, the NOx and smoke emitted from diesel vehicle are recognized as a main source of the air-pollution in the urban areas. The emission reduction devices have been installed for each of the emission gas components. Using plasma(i.e. electrical energy)only, the emission gas was found to be reduced. The present paper investigate the effects of a low temperature plasma device in engine performance as well as in emission reduction with the change of the applied voltage and the loading rate of the engine.

  • PDF

Development of Calculation Method on the GHG Emission of Railroad (철도부문 온실가스 배출량 산정 방법론 연구)

  • Lee, Jae-Young;Jung, Woo-Sung;Kwon, Tae-Soon;Kim, Hee-Man;Kang, Sung-Hae
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.828-830
    • /
    • 2009
  • In Korea, various efforts to cope with the Post-Kyoto system have been recently performed because a duty for the GHG(Greenhouse Gas) reduction may be allocated from 2013. Especially, the role of railroad has been strengthened to decrease total GHG emission of transportation system. Therefore, it is necessary to investigate the GHG emission and the reduction strategies of railroad. The purpose of this study was to develop the calculation method of GHG emission released from railroad. Main source of GHG emission was the energy consumption of railroad vehicle and infrastructure. Based on the emission factor and the equation reported in IPCC 2006 guideline, the total GHG emission of railroad was about 1.4 million tons CO2e in 2007. Using this calculation method, the GHG data of railroad can be calculated quantitatively and managed systematically in the future.

  • PDF

The Economic Analysis on the Heating System Remodeling by the Life Cycle Costing in Permanent Rental Apartment (LCC 기법을 이용한 영구임대아파트 난방방식 리모델링에 대한 경제성분석 -유지관리비용을 중심으로-)

  • 박민용;장승재
    • Journal of the Korean housing association
    • /
    • v.15 no.1
    • /
    • pp.33-40
    • /
    • 2004
  • Considering the present development situation of rental apartment since 1982, the supply of rental housing for low-income dwellers has contributed a amount of quantities, but has been deficient qualities in housing policy. To propose the device of remodeling for low-income dwellers in deteriorated apartment, this study investigated the energy consumption of central heating system and the characteristics of maintenance cost in permanent rental apartment. The results of evaluation of alternative heating systems by Life Cycle Costing in permanent rental apartment were as follows; From Life Cycle 15∼20 years by Present Worth Method, the economic heating system of remodeling is central heating system (heat source: B-C oil), unit heating system(natural gas), central heating system(natural gas) in order.

Implementation of the Arc Detection Device Using IR Sensor (IR 센서를 이용한 아크 발생 검출 장치 구현)

  • Hyun, Deuk-Chang
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.4
    • /
    • pp.258-262
    • /
    • 2017
  • Recently energy consumption has been increasing because of advances in the industry, and electrical fires have accounted for 31.9% of all fire accidents. An electrical fire is caused by a short circuit, power surge, or poor contact. Safety devices for short circuits or power surges are currently mandatory and can actually detect problems, but arcing caused by contact failure is difficult to detect in advance. This study used an IR sensor to detect the heat concentration caused by the arc. The data from the low-resolution sensor was amplified as much as four times by interpolation to find the exact location of the heat source and were then investigated.