• 제목/요약/키워드: Energy Conservation Measure

검색결과 35건 처리시간 0.028초

건물 주광환경 평가도구의 비교분석에 관한 연구 (Study on Comparative Analysis of Daylight Evaluation Tools for Building Environment)

  • 박경은;김준태
    • 한국태양에너지학회 논문집
    • /
    • 제22권4호
    • /
    • pp.26-34
    • /
    • 2002
  • Daylighting in building is very important as it has an effect on work performance as well as on their visual health. It is also regarded as a good energy conservation measure in saving energy used for lighting. There are many daylighting evaluation tools such as empirical equations, tables, nomograms, diagrams, protractors, computer simulation, scale models. This study conducted initial daylight measurements to analyze luminous environment in classrooms of elementary school and comparative analysis on three daylighting evaluation tools, such as daylight factor calculation formula, the graphic method with BRE Protractor and computer simulation with Adeline 3.0. It is found that the computer simulation tool produced the closest result to actual measurements of luminous environment in elementary school classroom, and the other simplified tools made appropriate results so that they can be used in the early stage of daylighting design process.

에너지 절약형 건물의 통합설계 확산을 위한 시뮬레이션 사용성 개선 방향 - 실무자 설문과 설계 프로세스 비교 및 분석을 중심으로 - (How to Improve Usability of Building Energy Simulation for the Integrated Design Process - Based on Practitioner Survey and Design Process Comparison -)

  • 김선혜
    • KIEAE Journal
    • /
    • 제15권6호
    • /
    • pp.47-56
    • /
    • 2015
  • Purpose and Method: Despite benefits of building energy simulations, practitioners seem to be reluctant to use simulations for design decision making. By means of survey and interviews, this study aims to investigate domestic hindrance against increasing simulation usability, and to collect user requirement to enhance technical functionality of the simulation. Also this study compares the Information Sharing Workflow by Stantec and general domestic design process in order to identify a direction of the Integrated Design Process. Result: Finally this study wraps up with suggestions of how simulation functionality and use protocol should be in order to satisfy user requirement and also to gather more users.

HFM, LFA와 TCi를 이용한 건축 재료의 열전도율 측정과 상관관계 분석 (Building Materials Thermal Conductivity Measurement and Correlation with Heat Flow Meter, Laser Flash Analysis and C-Therm TCi)

  • 차정훈;서정기;김수민
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.92-97
    • /
    • 2011
  • Nowdays the most critical problem is global warming and the most important reason is the high emition of carbondioxide. 23% of the use of carbondioxide is used in building and decreasing the use of it is very important. One of the biggest factor that can decrease the use of energy is developing the heat conducting ratio of the materials we use in building. Heat conducting ratio is the important factor in the use of reducing energy comsumation. In this research, there are methods about how to measure the heat conducting ratio, and the existing the representing measuring method which is Heat Flow Meter HFM 436, Laser Flash Analysis and find out about the TCi of the new method C-Therm and compare the results.

  • PDF

에너지 안보 및 기후변화 대책을 고려한 발전구성비의 도출 : 정책 목표간의 상호보완성을 중심으로 (Fuel Mix of Electricity Generating System Considering Energy Security and Climate Change Mitigations : Focusing on Complementarity between Policy Objectives)

  • 류하늬;김규남;김연배
    • 자원ㆍ환경경제연구
    • /
    • 제20권4호
    • /
    • pp.761-796
    • /
    • 2011
  • 본 연구는 발전부문에서 에너지 정책의 목표인 에너지 안보와 기후변화 대책 간의 상호보완성을 고려하면서 최저 비용을 기준으로 도출된 발전 구성비를 나타내었다. 에너지 안보의 수준을 측정하기 위해 에너지 안보 가격지수를 도입하여 화석연료의 공급 집중도에서 비롯된 안보 위협을 평가하였다. CSC 방법론의 적용을 통해 원자력과 육상풍력이 석탄가스화 복합발전 및 미분탄 화력발전을 대체하는 경우가 비용효율적인 대체안으로 나타났으며, 잠재적인 탄소 감축 가능량 및 안보 개선폭을 확인하였다. 또한 이러한 대체안이 탄소 감축뿐만 아니라 에너지 안보의 개선을 달성하는 상호보완성을 확인하였다. 추가적인 에너지 안보의 개선을 위해서는 화석연료의 해외자원개발을 통한 에너지 자급률을 제고하는 것이 최선의 대안으로 나타났으며, 이를 기반으로 2020년의 특정 목표치를 달성하기 위해 최저 비용을 나타내는 발전구성비를 도출하였다.

  • PDF

공동주택의 에너지 자립을 위한 핵심요소기술의 에너지 성능평가 (Energy Performance Evaluation of Zero Energy Technologies for Zero Energy Multi-House)

  • 윤종호;김병수
    • 한국태양에너지학회 논문집
    • /
    • 제27권3호
    • /
    • pp.161-167
    • /
    • 2007
  • Zero Energy Multi-House(ZeMH) signifies a residential building which can be self sufficient with just new and renewable energy resources without the aid of any existing fossil fuel. For success of ZeMH, various innovative energy technologies Including passive and active systems should be well integrated with a systematic design approach. The first step for ZeMH is definitely to minimize the conventional heating and cooling loads over 50% with major energy conservation measure and passive solar features which are mainly related to building design components such as super-insulation, super window, including infiltration and ventilation issues. The purpose of this study is to analyze the thermal effect of various building design components in the early design of ZeMH. The process of the study is presented in the following. 1) selection reference model for simulation 2) verification of reference model with computer simulation program(ESP-r 9.0). 3) analysis of effect according to insulation-thickness, kinds of windows, rate of infiltration. and The simulation results indicate that almost 50% savings of conventional heating load in multi-house can be achieved with the optimum design of building components such as super insulation, super window, infiltration, ventilation.

Definition of Power Quality Factors at The Point of Common Coupling in Single-Phase Systems and Three-Phase Systems

  • Kim Hyosung;Blaabjerg Frede;Bak-Jensen Birgitte
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.489-496
    • /
    • 2001
  • This paper proposes an unified definition of powers for various circuit conditions such as balanced/unbalanced, sinusoidal/non-sinusoidal, and linear/nonlinear, for single-phase systems and three-phase systems. Conventional reactive power is more classified into an interactive power and a scattering power. These powers are defined both in the time domain and the frequency domain consistently, and agree well with the conservation law. Several important power quality factors are defined to measure and evaluate the power quality for the various circuits in the single-phase and three-phase systems. Simulation results show the power quality factors can evaluate and classify the various circuit conditions clearly.

  • PDF

Definition of Powers and Power Quality Factors at a Point of Common Coupling in Single-Phase Systems and Three-Phase Systems

  • Kim, Hyosung;Frede Blaabjerg;Jensen, Birgitte-Bak
    • Journal of Power Electronics
    • /
    • 제2권1호
    • /
    • pp.32-45
    • /
    • 2002
  • This paper proposes an unified definition of powers for various circuit conditions such as balanced/unbalanced, sinusoidal/non-sinusoidal, and linear/nonlinear, fur single-phase systems and three-phase systems. Conventional reactive power is more classified into an interactive power and an alternating power. These powers are defined both in the time domain and the frequency domain consistently, and agree well with the conservation law. Several important power quality factors are defined to measure and evaluate the power quality fur the various circuits in the single-phase and three-phase systems. Simulation results show the power quality factors can evaluate and classify the various circuit conditions clearly.

Investigation of school building microclimate using advanced energy equipment: Case study

  • Alwetaishi, Mamdooh;Alzaed, Ali;Sonetti, Giulia;Shrahily, Raid;Jalil, Latif
    • Environmental Engineering Research
    • /
    • 제23권1호
    • /
    • pp.10-20
    • /
    • 2018
  • Buildings are responsible of major energy consumption globally. In addition, they are linked to thermal comfort. The need to provide comfort becomes more crucial in schools as they are the place where students learn, and develop their skills. This research aims to investigate the energy responsiveness of new and traditional school building design, where major variation in form, amount of external walls and glazing are different. The research focused on indoor microclimate condition of selected schools in the city of Jeddah where the climate is hot and humid using advanced tools for monitoring. The research uses advanced energy equipment to measure several aspects such as floor temperature, roof temperature, globe temperature and other factors which can lead to predictable thermal comfort of users. The findings suggest that a larger area of glazing shielded from sunlight has a greater influence on both indoor condition and general thermal sensation. The finding also suggests that the glazing ratio is a major contributor on indoor thermal pattern which can result in an increase in temperature profile between from $7-10^{\circ}C$. The findings of this research can assist in the improvement in the design of the prototype school building in hot and humid climate.

Multi-Attribute Data Fusion for Energy Equilibrium Routing in Wireless Sensor Networks

  • Lin, Kai;Wang, Lei;Li, Keqiu;Shu, Lei
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제4권1호
    • /
    • pp.5-24
    • /
    • 2010
  • Data fusion is an attractive technology because it allows various trade-offs related to performance metrics, e.g., energy, latency, accuracy, fault-tolerance and security in wireless sensor networks (WSNs). Under a complicated environment, each sensor node must be equipped with more than one type of sensor module to monitor multi-targets, so that the complexity for the fusion process is increased due to the existence of various physical attributes. In this paper, we first investigate the process and performance of multi-attribute fusion in data gathering of WSNs, and then propose a self-adaptive threshold method to balance the different change rates of each attributive data. Furthermore, we present a method to measure the energy-conservation efficiency of multi-attribute fusion. Based on our proposed methods, we design a novel energy equilibrium routing method for WSNs, viz., multi-attribute fusion tree (MAFT). Simulation results demonstrate that MAFT achieves very good performance in terms of the network lifetime.

토양의 총 경제적 가치 (The Total Economic Value of Soil in Korea)

  • 박소연;유승훈
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제21권6호
    • /
    • pp.156-168
    • /
    • 2016
  • The Korean government is planning to invest a lot of funds for conservation of the soil. Accordingly, it needs quantitative information on the soil. This paper attempts to analyze the total value of soil quantitatively: the total economic value of soil can be divided into use value and non-use value. To this end, we apply a replacement cost method (RCM) and contingent valuation method (CVM). Especially, CVM is most widely used to measure the non-use value such as environment goods. We employed the one-and-one-half-bounded dichotomous choice (OOHBDC) for willingness to pay (WTP) elicitation and a spike model. The monthly mean WTP was estimated to be KRW 3,949 per household for the next 10 years, which is statistically significant at the 1% level. Expanding the value to the relevant population gives us KRW 897.9 billion per year and as of the end of 2015, the non-use value of soil was assessed to be KRW 838.6 billion. Meanwhile, use value is subdivided into direct use value and indirect use value. This value was calculated KRW 3,277 trillion and KRW 51.8 trillion, respectively. As a result, total economic value of soil is estimated to be KRW 3,330 trillion in Korea.