• Title/Summary/Keyword: Energy Coefficient

Search Result 2,859, Processing Time 0.025 seconds

Determination of Effective Energy of CT X-ray beams (CT X-선 빔들의 유효에너지 결정)

  • Kim, Jong Eon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.517-522
    • /
    • 2019
  • The purpose of this study is to determine the effective energy of CT X-ray beams by using the CT slice images of a CT number calibration insert part in the AAPM CT performance phantom. The CT number calibration insert part in the AAPM CT performance phantom was scanned five times by using a CT canner for 80, 100 and 120 kVp X-ray beams. The average value of CT numbers of each pin were measured for each CT slice image. The correlation coefficients were obtained by linear fit between the average value of CT numbers measured and liner attenuation coefficient under different energy at each pin calculated from data of NIST. A photon energy corresponding to the maximum value of the obtained correlation coefficient was determined as an effective energy. As a result, the effective energy was 56, 62 and 66~67 keV, respectively, for 80, 100 and 120 kVp X-ray beams.

Thermal Performance Evaluation of The Window Film Insulation for Building Energy Savings (건물에너지 절감을 위한 열차단 필름의 성능 평가)

  • Nam, Jung-Woo;Won, Jong-Seo
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.75-80
    • /
    • 2008
  • Recently, Energy savings in buildings has received much attention in response to the increased needs for global warming and better comforts of the occupants in apartment housing. This study proposes the method which uses the sun control window film to reduce the cooling load and heating load improving the thermal performance of the building and it improves an energy efficiency. The film which used in actual measurement has a low shading coefficient and a solar energy transmission. so we measured the surface temperature of the triple Low-e glazing system used and inside temperature according to the change of outside temperature and solar energy to study thermal performance evaluation. As a result, it was helpful to use window film insulation to reduce inside temperature in summer and to keep room warm in winter.

  • PDF

A Comparison of Energy Intake and Energy Expenditure in Normal-Weight and Over-Weight Korean Adults (정상체중 성인과 과체중 성인의 에너지 섭취량, 휴식대사량, 활동대사량 비교연구)

  • 박정아;김기진;윤진숙
    • Korean Journal of Community Nutrition
    • /
    • v.9 no.3
    • /
    • pp.285-291
    • /
    • 2004
  • The purpose of this study was to compare the energy expenditure and energy intake of normal-weight and overweight Korean adults. We recruited 242 adults to determine resting energy expenditure, physical activity and energy intake. Resting energy expenditure was measured by indirect calorimetry. Energy intake for consecutive two days was assessed by 24 hour recall method. Daily activity pattern for 24 hour was collected from each subject. Body weight, lean body mass and percentage body fat were measured by INBODY 3.0. The subject were divided into normal ($20\leqBMI$ < 25) and overweight ($BMI \geq 25$) groups by BMI. There was no significant difference in intake of energy between two groups. Energy intake of each group was lower than the 7th Korean RDA of energy. Overweight subjects showed significantly lower REE/kg body weight. However, REE/kg lean body mass (LBM) did not differ between the two groups. Total activity energy was significantly higher in the overweight group compared to the normal group. Daily activity coefficient of overweight group in male was lower than that of normal group. Daily activity coefficient was almost same in two female groups. LBM was highly correlated with REE and total energy expenditure. We concluded that the overweight group consumed more energy than the normal group due to the heavier body weight.

A Study on the Flow Characteristics around Tidal Current Turbine (조류발전용 터빈 주위의 유동 특성에 관한 연구)

  • Kim, Bu-Gi;Yang, Chang-Jo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.18 no.6
    • /
    • pp.610-616
    • /
    • 2012
  • All the countries in the world is currently facing the full scale of energy-climate era currently, and making strong energy policy that will lead to green growth of the future energy resources by utilizing renewable energy as the basis of entering the advanced country becomes the goal of development that satisfies the demand for energy in 21st century. Recently, ocean energy attracted the attention along with the necessity of developing renewable energy. Ocean energy is the one of most prominent recyclable and clean resources that has not been developed yet. So, it is highly required to develop good tidal current energy conversion system in coastal area. The inflow angle that acts against tidal current turbine, seabed effect and the change of efficiency along the occurrence of cavitation were investigated through the wake flow characteristics in this study. Power coefficient degradation by seabed effect did not appear in the condition of this calculation. Efficiency degradation appeared from above $10^{\circ}$ regarding inflow angle and power coefficient was calculated as lower by 7 % at $45^{\circ}$. Torque and power coefficient increased as inflow velocity rose, but power coefficient degradation appeared from above 3m/s when the cavitation happened. So, it was recognized that the larger inflow angle and occurrence of cavitation become the reason for power degradation through the flow characteristics.

The Effect of Energy-Saving Investment on Reduction of Greenhouse Gas Emissions (에너지절약투자의 온실가스 배출 감소 효과)

  • Kim, Hyeon;Jeong, Kyeong-Soo
    • Environmental and Resource Economics Review
    • /
    • v.9 no.5
    • /
    • pp.925-945
    • /
    • 2000
  • This paper analyses the impact of energy-saving investment on Greenhouse gas emissions using a model of energy demand in Korea. SUR method was employed to estimate the demand equation. The econometric estimates provide information about the energy price divisia index, sector income, and energy saving-investment elasticities of energy demand. Except for energy price divisia, the elasticities of each variable are statistically significant. Also, the price and substitution elasticities of each energy price are similar to the results reported by the previous studies. The energy-saving investment is statistically significant and elasticities of each sector is inelastic. Using the coefficient of energy-saving investment and carbon transmission coefficient, the amount of reduction of energy demand and the reduction of carbon emissions can be estimated. The simulation is performed with the scenario that the energy-saving investment increase by 10~50%, keeping up with Equipment Investment Plan of 30% increase in energy-saving investment by 2000. The results show that the reduction of energy demand measured as 11.2% based upon 1995's level of the energy demand, in industrial sector. Accordingly, the carbon emissions will be reduced by 11.3% based upon 1995's level of the carbon emissions in industrial sector.

  • PDF

The Analysis of Activity Energy, Total Energy, and Estimated Energy Expenditures in 5th and 6th Grade Primary School Students (초등학교 5, 6학년 남녀학생의 활동에너지 소비량 및 에너지필요추정량 분석)

  • Kim, Mi-Jeong;Na, Hyeon-Ju;Kim, Young-Nam
    • Korean Journal of Community Nutrition
    • /
    • v.16 no.2
    • /
    • pp.195-205
    • /
    • 2011
  • This study was conducted to investigate the time spent, activity coefficient and energy expenditure on 7 different types of activity. Total of 386 5th and 6th grade primary school boys and girls in Seoul participated in this study. The participants spent 8 hrs for rest, 4 hrs for out of school study, 3 hrs for leisure, 1 hr 45 mins. for hygiene, 1 hr for commute, and 15 mins. for house choir activity in the day of 6 class hours. The average activity coefficient of 1 day for boys and girls were 1.69 and 1.64, respectively. The TEEs were 2,382 kcal and 2,050 kcal for boys and girls, respectively. The energy cost for study related activity (in school and study activities) was 40% of the TEE, and for rest 20%, for commute 9%, and for hygiene 10% of the TEE. The energy cost for house choir was only about 2% of TEE. The 91.2% participant's EER was higher than the EER shown in the table of 2010 DRI for Koreans. When the participant's EER was compared with the energy allowance calculated by the method in 2000 RDA for Korean, 81.6% was in the range of ${\pm}5%$, and the correlation coefficients between the 2 values were 0.981 for boys and 0.978 for girls, which means high agreements.

Impact of Horizontal Global Solar Radiation Calculation Modelson Building Energy Performance Analysis Considering Solar Heat Gain Coefficient and Window-to-wall Ratio (수평면 전일사량 산출모델이 일사열취득계수 및 창면적비를 고려한 건물 에너지 성능분석에 미치는 영향)

  • Kim, Kee Han;Oh, John Kie-Whan
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.1
    • /
    • pp.39-47
    • /
    • 2014
  • Solar applications analysis and building energy performance depend on the quality of the solar resource data available. Unfortunately, most of the weather stations do not measure solar radiation data in Korea, as a reason many researchers have studied different solar radiation estimation models and suggested to apply them to various locations in Korea. In addition, they also studied the impact of hourly global solar radiation on energy performance of an office building by comparing the simulated building energy consumptions using four different weather files, one using measured, and three estimated solar radiation from different models, which are Cloud-cover Radiation Model (CRM), Zhang and Huang Model (ZHM), and Meteorological Radiation Model (MRM), and concluded that there was some impact on energy performance of the building due to the using different solar radiation models. However, the result cannot be applied to all other buildings since the simulated office building for that study only used limited building characteristics such as using fixed values of solar heat gain coefficient (SHGC) and window-to-wall ratio (WWR), which are significant parameters related to solar radiation that affect to the building energy consumptions. Therefore, there is a need to identify how the building energy consumption will be changed by varying these building parameters. In this study, the impact of one measured and three estimated global solar radiation on energy performance of the office building was conducted taking account of SHGC and WWR. As a result, it was identified that the impact of four different solar radiation data on energy performance of the office building was evident regardless SHGC and WWR changes, and concluded that the most suitable solar models was changed from the CRM/ZHM to the MRM as SHGC and WWR increases.

Study on the mixing performance of mixing vane grids and mixing coefficient by CFD and subchannel analysis code in a 5×5 rod bundle

  • Bin Han ;Xiaoliang Zhu;Bao-Wen Yang;Aiguo Liu;Yanyan Xi ;Lei Liu ;Shenghui Liu;Junlin Huang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3775-3786
    • /
    • 2023
  • Mixing Vane Grid (MVG) is one of the most important structures in fuel assembly due to its high performance in mixing the coolant and ultimately increasing Critical Heat Flux (CHF), which avoids the temperature rising suddenly of fuel rods. To evaluate the mixing performance of the MVG, a Total Diffusion Coefficient (TDC) mixing coefficient is defined in the subchannel analysis code. Conventionally, the TDC of the spacer grid is obtained from the combination of experiments and subchannel analysis. However, the processing of obtaining and determine a reasonable TDC is much challenging, it is affected by boundary conditions and MVG geometries. In is difficult to perform all the large and costing rod bundle tests. In this paper, the CFD method was applied in TDC analysis. A typical 5 × 5 MVG was simulated and validated to estimate the mixing performance of the MVG. The subchannel code was used to calculate the TDC. Firstly, the CFD method was validated from the aspect of pressure drop and lateral temperature distribution in the subchannels. Then the effect of boundary conditions including the inlet temperature, inlet velocities, heat flux ratio between hot and cold rods and the arrangement of hot and cold rods on MVG mixing and TDC were studied. The geometric effects on mixing are also carried out in this paper. The effect of vane pattern on mixing was investigated to determine which one is the best to represent the grid's mixing performance.

Characteristics of the Seasonal Variation of the Radiation in a Mixed Forest at Kwangneung Arboretum (광릉수목원 혼합림에서 복사 에너지의 계절 변화 특성)

  • 김연희;조경숙;김현탁;엄향희;최병철
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.3
    • /
    • pp.285-296
    • /
    • 2003
  • The measurement of the radiation energy, trunk temperature, leaf area index (LAI), air temperature, vapor pres-sure, and precipitation has been conducted under a mixed forest at Kwangneung Arboretum during the period of 2001. Characteristics of the diurnal and seasonal variation of the radiative energy were investigated. The aerodynamic roughness length was determined as about 1.6 m and the mean albedo was about 0.1 The downward short-wave radiation was linearly correlated with the net radiation and its correlation coefficient was about 0.96. From this linear relation, the heating coefficient was calculated and its annual mean value was about 0.21 The albedo and heating coefficient was varied with season, surface characteristics, and meteorological conditions. The diurnal and seasonal variations of radiation energy were discussed in terms of the surface characteristics and meteorological conditions. In the daytime, during clear skies, net radiation was dominated by the shortwave radiation. In presence of clouds and fog, the radiation energy was diminished. At night, the net radiation was entirely dominated due to the net longwave radiation. There was no distinct diurnal variation in net radiation flux during the overcast or rainy days. The net radiation was strongest in spring and weakest in winter. The seasonal development in leaf area was also reflected in a strong seasonal pattern of the radiation energy balance. The timing, duration, and maximum leaf area and trunk temperature were found to be an important control on radiation energy budget. The trunk temperature was either equal or warmer than air temperature during most of the growing season because the canopy could absorb a substantial amount of sunlight. After autumn (after the middle of October), the trunk temperature was consistently cooler than air temperature.

Evaluation of Blast Pressure Generated by an Explosion of Explosive Material (폭발성 물질의 폭발에 따른 폭발압력 평가)

  • Yoon, Yong-Kyun
    • Explosives and Blasting
    • /
    • v.36 no.4
    • /
    • pp.26-34
    • /
    • 2018
  • Explosions of vapor cloud formed due to the leakage from installations with flammable fuels have often occurred in Korea and foreign countries. In this study, TNT equivalency method and Multi-Energy method for vapor cloud explosion blast modelling are described and demonstrated in a case study. As TNT equivalency method is simple and direct, it has been widely used for modelling a vapor cloud explosion blast. But TNT equivalency method found to be difficult to select a proper correlation between the amount of combustion energy produced from the vapor cloud explosion and the equivalent amount of TNT to model its blast effects. Multi-Energy method assumes that the strength of vapor cloud explosion blast depends on the layout of the space where the vapor cloud is spreading. Strictly speaking, the explosive potential of a vapor cloud is dependent upon the density of the obstructed regions. In this study, Flixborough accident are analyzed as a case study to assess the applicability of TNT equivalency method and Multi-Energy method. TNT equivalency method and Multi-Energy method found to be applicable if coefficient of TNT equivalency and coefficient of strength of explosion blast are selected properly.