• Title/Summary/Keyword: Endovascular stent

Search Result 163, Processing Time 0.025 seconds

Analysis of failed mechanical thrombectomy with a focus on technical reasons: Ten years of experience in a single institution

  • Sinho Park;Dong Hoon Lee;Jae Hoon Sung;Seung Yoon Song
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • v.25 no.1
    • /
    • pp.13-18
    • /
    • 2023
  • Objective: Mechanical thrombectomy (MT) is an effective treatment for patients suffering from acute ischemic stroke secondary to large vessel occlusion. However, recanalization failure rates of interventions were about 20% in literature studies. We report our experience of unsuccessful MT with a focus on technical reasons. Methods: From December 2010 to June 2021, six hundred eight patients with acute ischemic stroke due to large artery occlusion received MT using a stent retriever with or without an aspiration catheter in our institution. We divided the reasons for failure into six categories. We analyzed the reasons for failure by dividing our experience time into 3 periods. Results: A total of 608 cases of thrombectomy for large vessel occlusion were identified in the study period. The successful recanalization rate was 90.4%. In most of the cases (20/57, 35%), the thrombus persisted despite several passes, and the second most common cause was termination of the procedure even after partial recanalization (10/57, 18%). Similar proportions of in-stent occlusion, distal embolization, and termination due to vessel rupture were observed. On analysis of three periods, the successful recanalization rate improved over time. Conclusions: MT fails due to various reasons, and intracranial artery stenosis is the main cause of MT failure. With the development of rescue techniques, the failure rate has gradually decreased. Further development of new devices and techniques could improve the recanalization rates.

Early and Midterm Results of Hybrid Endovascular Repair for Thoracic Aortic Disease (흉부대동맥 질환에서 시행된 하이브리드 혈관내 성형술의 중단기 성적)

  • Youn, Young-Nam;Kim, Kwan-Wook;Hong, Soon-Chang;Lee, Sak;Chang, Byung-Chul;Song, Seung-Jun
    • Journal of Chest Surgery
    • /
    • v.43 no.5
    • /
    • pp.490-498
    • /
    • 2010
  • Background: A hybrid procedure using an open surgical extra-anatomic bypass of aortic arch vessels and thoracic endovascular aortic repair (TEVAR) is less invasive than open surgery, and provides a suitable proximal landing zone. Here we report our experience with a hybrid TEVAR procedure at a single center. Material and Method: We retrospectively reviewed consecutive patients with thoracic aortic disease who received a hybrid TEVAR procedure between August 2008 and January 2010. Patients' data were prospectively collected and mean follow-up was $10.8{\pm}5.5$ months (range 3~20). Result: Nine patients (7 males and 2 females) with a mean age of $63.8{\pm}15.8$ years (range 38~84) underwent a hybrid procedure. Five patients had an arch or a proximal descending aortic aneurysm, two had a dissecting aneurysm of the descending aorta, and two had an aneurysm of the ascending arch and descending aorta. Mean expected mortality calculated by logistic EuroSCORE was 21%. Six patients underwent debranching and rerouting from ascending aorta to arch vessels, 2 had carotid-carotid bypass grafting, and 1 underwent carotid-axillary bypass grafting. Mean operation time was $221.4{\pm}84.0$ min (range 94~364). Deployment success of endovascular stent grafting was 100% with no endoleak on completion angiography. There was no mortality, and a small embolism in the branch of the right opthalmic artery in one patient. During follow-up, one intervention was required for the endoleak. Actuarial survival at 20 months was 100%. Conclusion: Early and mid-term results are encouraging and suggest that hybrid TEVAR procedures are less invasive and safer and represent an effective technique for treating thoracic aortic disease.

Single Center Experience of the Balloon-Stent Technique for the Treatment of Unruptured Distal Internal Carotid Artery Aneurysms: Sharing a Simple and Reliable Tip to Use Scepter-Atlas Combination (원위내경동맥에 위치한 비파열성 동맥류의 치료에 있어 풍선-스텐트 테크닉에 대한 단일기관의 경험: Scepter-Atlas 조합을 사용하기 위한 간단하지만 확실한 방법)

  • Yu-jung Park;Jieun Roh;Seung Kug Baik;Jeong A Yeom;Chul-Hoo Kang;Hee Seok Jeong;Sang Won Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.5
    • /
    • pp.1258-1273
    • /
    • 2021
  • Purpose The balloon-stent technique (BST) has certain strengths as an assisted technique for the treatment of complex aneurysms. After Atlas release, the BST can be executed without an exchange maneuver of the balloon to the stent-delivery catheter. The purpose of this article is to share our experience with the BST using the Scepter-Atlas combination. Materials and Methods Device inspection led us to a simple method to avoid failure in loading Atlas to the Scepter. From March 2018 to December 2019, 57 unruptured distal internal carotid artery (dICA) aneurysms were treated with coil embolization; among which, 25 aneurysms in 23 patients were treated with BST. Clinical and angiographic data were retrospectively collected and reviewed. Results The technical success rate of the Scepter-Atlas combination increased from 50% to 100% after careful inspection. BST angiographic results were comparable to the stent-assisted coil (SAC) group treated during the immediately post-embolization same period (modified Raymond-Roy classification [MRRC] 1 & 2 84% in BST, 96.3% in SAC) and during short-term follow-up (MRRC 1 & 2 95.8% in BST, 88.4% in SAC). A small number of patients showed periprocedural complications, but none had clinical consequences. Conclusion BST using the Scepter-Atlas combination can provide an effective and safe method for the treatment of dICA aneurysms. Scepters can be used as delivery catheters for Atlas.

Intervention for Chest Trauma and Large Vessel Injury (흉부 및 대혈관 외상의 인터벤션)

  • Hojun Lee;Hoon Kwon;Chang Won Kim;Lee Hwangbo
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.4
    • /
    • pp.809-823
    • /
    • 2023
  • Trauma is an injury to the body that involves multiple anatomical and pathophysiological changes caused by forces acting from outside the body. The number of patients with trauma is increasing as our society becomes more sophisticated. The importance and demand of traumatology are growing due to the development and spread of treatment and diagnostic technologies. In particular, damage to the large blood vessels of the chest can be life-threatening, and the sequelae are often severe; therefore, diagnostic and therapeutic methods are becoming increasingly important. Trauma to nonaortic vessels of the thorax and aorta results in varying degrees of physical damage depending on the mechanism of the accident and anatomical damage involved. The main damage is hemorrhage from non-aortic vessels of the thorax and aorta, accompanied by hemodynamic instability and coagulation disorders, which can be life-threatening. Immediate diagnosis and rapid therapeutic access can often improve the prognosis. The treatment of trauma can be surgical or interventional, depending on the patient's condition. Among them, interventional procedures are increasingly gaining popularity owing to their convenience, rapidity, and high therapeutic effectiveness, with increasing use in more trauma centers worldwide. Typical interventional procedures for patients with thoracic trauma include embolization for non-aortic injuries and thoracic endovascular aortic repair for aortic injuries. These procedures have many advantages over surgical treatments, such as fewer internal or surgical side effects, and can be performed more quickly than surgical procedures, contributing to improved outcomes for patients with trauma.

Initial Experience of ACE68 Reperfusion Catheter in Patients with Acute Ischemic Stroke Related to Internal Carotid Artery Occlusion

  • Jang, Hyoung-Gyu;Park, Jung-Soo;Lee, Jong-Myong;Kwak, Hyo-Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.5
    • /
    • pp.545-550
    • /
    • 2019
  • Objective : Penumbra ACE68 reperfusion catheter is a new large bore aspiration catheter used for reperfusion of large vessel occlusion. The objective of this study was to investigate the efficacy of this catheter in comparison to that of previous Penumbra catheters in patients with acute ischemic stroke related to internal carotid artery (ICA) occlusion. Methods : Data of all eligible patients who received endovascular treatment (EVT) for ICA occlusion using Penumbra aspiration catheters between January 2015 and December 2018 were retrospectively reviewed. After dividing into two groups according to use of penumbra ACE68, baseline characteristics of patients, successful recanalization rate, puncture to recanalization time, and switch to stent base technique rate were assessed. Successful recanalization was defined by a thrombolysis in cerebral infarction (TICI) score ${\geq}2b$ and favorable functional outcome was defined according to modified Rankin scale (score, 0-2). Results : ACE68 reperfusion catheter was used in 29 of 75 eligible patients (39%). The puncture to recanalization time was significantly shorter ($26{\pm}18.2$ minutes vs. $40{\pm}24.9$ minutes, p=0.011) and the rate of switch to stent-based retrieval was significantly lower (3% vs. 20%, p=0.046) in ACE68 catheter group. Moreover, although not statistically significant, the successful recanalization rate was higher (83% vs. 76%, p=0.492) in ACE68 catheter group. Favorable functional outcome was observed in 48% of patients treated with ACE68 reperfusion catheter and in 30% of patients treated using other Penumbra systems (p=0.120). Baseline Alberta Stroke Program Early CT Scores ${\geq}8$ (odds ratio [OR], 9.74; 95% confidence interval [CI], 1.72-54.99; p=0.010) and successful recanalization (OR, 10.20; 95% CI, 1.13-92.46; p=0.039) were independent predictors of favorable outcome. Conclusion : EVT using ACE68 reperfusion catheter can be considered a first-line therapy in patients with acute ICA occlusion as it can achieve rapid recanalization and reduce the frequency of conversion to stent-retrieve therapy.

Treatment for Giant Fusiform Aneurysm Located in the Cavernous Segment of the Internal Carotid Artery Using the Pipeline Embolization Device

  • Oh, Se-Yang;Kim, Myeong Jin;Kim, Bum-Soo;Shin, Yong Sam
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.1
    • /
    • pp.32-35
    • /
    • 2014
  • The pipeline embolization device (PED) is a new endovascular device for treatment of complex, fusiform and wide-neck intracranial aneurysms. The main mechanism of this stent is to divert the flow in the parent artery with reduction of inflow in the aneurysm leading to thrombosis. We treated a 40-year-old woman who had left facial pain and orbit discomfort. Angiography showed a giant fusiform aneurysm located in the cavernous segment of the left internal carotid artery. A PED was successfully deployed across the aneurysm. The procedure and post-procedural course were uneventful. After 3 months, angiography showed complete obliteration of the aneurysm with good patency of the branching vessels originating from the deployed segment. The patient's symptoms improved completely without complications.

Left Common Iliac Artery Rupture due to Hidden Blunt Trauma (Suspected Dildo-Masturbation Injury via Endovagina): A Case Report (내재된 둔상으로 인한 좌측 총 장골동맥 파열에 따른 출혈성 심정지 (질 내 경로를 통한 자위 행위로 인한 손상 의심): 증례보고)

  • Kyoung, Kyu Hyouck;Kim, Mi Jin;Choi, Byung Ho;Hong, Jung Seok;Hong, Eun Seog
    • Journal of Trauma and Injury
    • /
    • v.27 no.4
    • /
    • pp.211-214
    • /
    • 2014
  • A 34-year-old woman experienced a sudden cardiac arrest after complaining of abdominal pain. The cause of that serious event was a hidden hemorrhagic shock. On computed tomography of her pelvic area, we found that her left common iliac artery had been ruptured. No bone fractures were observed. Her angiography showed neither atherosclerosis nor an aneurysm of the artery. Because spontaneous ruptures of the common iliac artery are rare, we suspected, based on her husband's statement, that a hidden blunt trauma to the artery had occurred via an endo-vaginal route due to dildo masturbation. Unfortunately, she died without recovery, in spite of our having controlled the bleeding by using an angiographic endovascular stent-graft.

Next-Generation Frozen Elephant Trunk Technique in the Era of Precision Medicine

  • Suk-Won Song;Ha Lee;Myeong Su Kim;Randolph Hung Leung Wong;Jacky Yan Kit Ho;Wilson Y. Szeto;Heinz Jakob
    • Journal of Chest Surgery
    • /
    • v.57 no.5
    • /
    • pp.419-429
    • /
    • 2024
  • The frozen elephant trunk (FET) technique can be applied to extensive aortic pathology, including lesions in the aortic arch and proximal descending thoracic aorta. FET is useful for tear-oriented surgery in dissections, managing malperfusion syndrome, and promoting positive aortic remodeling. Despite these benefits, complications such as distal stent-induced new entry and spinal cord ischemia can pose serious problems with the FET technique. To prevent these complications, careful sizing and planning of the FET are crucial. Additionally, since the FET technique involves total arch replacement, meticulous surgical skills are essential, particularly for young surgeons. In this article, we propose several techniques to simplify surgical procedures, which may lead to better outcomes for patients with extensive aortic pathology. In the era of precision medicine, the next-generation FET device could facilitate the treatment of complex aortic diseases through a patient-tailored approach.

Endovascular Repair of Acute Type B Aortic Dissection: The Early Results and Aortic Wall Changes (급성 B형 대동맥 박리의 혈관내 스텐트-그라프트 삽입이 초기성적 및 대동맥 벽의 변화)

  • Her, Keun;Won, Yong-Soon;Shin, Hwa-Kyun;Yang, Jin-Sung;Baek, Kang-Seok
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.648-654
    • /
    • 2010
  • Background: This study assessed the early results of endovascular repair of acute type B aortic dissection and the aortic wall changes following endovascular repair. Material and Method: From July 2008 to May 2009, the preoperative and follow-up computed tomography (CT) scans of 5 patients with acute type B aortic dissection were evaluated, and these patients had underwent stent graft implantation within 13 days of the onset of dissection (mean: 7 days; range: 3~13). The whole lumen (WL), true lumen (TL) and false lumen (FL) diameters were measured at the proximal (p), middle (m) and distal (d) third of the descending thoracic aorta. Result: The study included four men and one woman with an average age of $59.4{\pm}20.1$ years (age range: 37~79 years). The follow-up CT was performed and evaluated at 7 days and 6 months. The primary tear was completely sealed in all the patients. No paraplegia, paresis or peripheral ischemia occurred and none of the patients died. No endoleaks developed in any of the patients during follow-up. The TL diameters increased from 20.4 to 33.5 mm in the proximal third (p/3), from 19.5 to 29.8 mm in the middle third (m/3) and from 15.2 to 23.5 mm in the distal third (d/3). The FL diameters decreased from 18.7 to 0 mm in the p/3, from 15.4 to 0 mm in the m/3 and from 21.4 to 8.7 mm in the d/3. The changes in the TL diameter were statistically significant in the middle and distal aorta, and those changes in the FL diameter were not statistically significant. There was a decrease in the WL after repair, but this was not statistically Significant. In three patients, the false lumen disappeared completely on follow-up CT at 6 months. Two patients had patent false lumens and no thrombosis. Conclusion: The early results showed that endovascular repair was effective in treating acute type B aortic dissection, and endovascular repair promoted positive aortic wall changes.

Clinical Outcomes After Drug-Coated Balloon Treatment in Popliteal Artery Disease: K-POP Registry 12-Month Results

  • Jong-Il Park;Young-Guk Ko;Seung-Jun Lee;Chul-Min Ahn;Seung-Woon Rha;Cheol-Woong Yu;Jong Kwan Park;Sang-Ho Park;Jae-Hwan Lee;Su-Hong Kim;Yong-Joon Lee;Sung-Jin Hong;Jung-Sun Kim;Byeong-Keuk Kim;Myeong-Ki Hong;Donghoon Choi
    • Korean Circulation Journal
    • /
    • v.54 no.8
    • /
    • pp.454-465
    • /
    • 2024
  • Background and Objectives: The popliteal artery is generally regarded as a "no-stent zone." Limited data are available on the outcomes of drug-coated balloons (DCBs) for popliteal artery disease. This study aimed to evaluate the 12-month clinical outcomes among patients who received DCB treatment for atherosclerotic popliteal artery disease. Methods: This prospective, multicenter registry study enrolled 100 patients from 7 Korean endovascular centers who underwent endovascular therapy using IN.PACT DCB (Medtronic) for symptomatic atherosclerotic popliteal artery disease. The primary endpoint was 12-month clinical primary patency and the secondary endpoint was clinically driven target lesion revascularization (TLR)-free rate. Results: The mean age of the study cohort was 65.7±10.8 years, and 77% of enrolled patients were men. The mean lesion length was 93.7±53.7 mm, and total occlusions were present in 45% of patients. Technical success was achieved in all patients. Combined atherectomy was performed in 17% and provisional stenting was required in 11%. Out of the enrolled patients, 91 patients completed the 12-month follow-up. Clinical primary patency and TLR-free survival rates at 12 months were 76.0% and 87.2%, respectively. A multivariate Cox regression analysis identified female and longer lesion length as the significant independent predictors of loss of patency. Conclusions: DCB treatment yielded favorable 12-month clinical primary patency and TLR-free survival outcomes in patients with popliteal artery disease.