• Title/Summary/Keyword: Endosseous implants

Search Result 78, Processing Time 0.029 seconds

ALVEOLAR BONE LOSS & BONE DENSITY CHANCES DURING THE FIRST YEAR A COMPARATIVE STUDY ON FOUR TYPES OF ROOT-FORM ENDOSSEOUS DENTAL IMPLANT SYSTEMS (치근형 골내 임플란트의 초기 1년간 치조골 소실 및 골 밀도 변화에 관한 연구)

  • Jung Young-Chul;Han Chong-Hyun;Lee Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.3
    • /
    • pp.455-469
    • /
    • 1994
  • Regular radiographic examination has been considered an essential diagnositic method for osseointegrated dental implantation. This study investigated marginal bone loss through the measurement on periapical radiographs and changes in bone density through digital subtraction image radiographic method around 88 endoseous root-form dental implants in 43 human subjects. Four types of endosseous dental implants were investigated : Standard series, Mini series and Hex-lock system of Steri-Oss Dental implant system, and $Br{\aa}nemark$-type implant from 3i dental implant system, in a 3 month interval for a total period of 12 months. The results were as follows : 1. Rapid bone loss occurred in the first 3 months in all 4 groups, and the bone level stabilized at the first thread of the implant fixtures. Amount of bone loss for 12 months showed correlation with the length of the polished neck portion. 2. Most of the implant systems showed resorption of alveolar bone up to the polished neck portion although a long polished neck could delay the resolution. 3. Alveolar bone loss apical to the polished neck portion stabilized at the first thread of the fixtures with no correlation to either the time of exposure of the polished neck or types of implant systems. 4. No changes in bone density around the implant threads were observed throughout the experimental period. Bone density decreased at the marginal bone, and increased at the newly-formed alveolar crest. These results indicate that most of the alveolar bone loss occur within the first 12 months after installation of endosseous root-form dental implants resulting in the exposure of polished neck portions, and the bone level stabilizes thereafter at the first thread portions of the implant fixtures. The experimental period of 12 months seems insufficient for observing changes in bone density, and a long-term observation should be needed.

  • PDF

A CLINICAL STUDY OF MAXILLARY SINUS LIFT FOR DENTAL IMPLANT (임프란트 식립을 위한 상악동 거상술의 임상적 연구)

  • Lee, Seong-Jae;Jang, Hyon-Seok;Lee, Boo-Kyu;Kwon, Jong-Jin;Rim, Jae-Suk
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.21 no.4
    • /
    • pp.376-381
    • /
    • 1999
  • A variety of materials and procedures such as sinus floor elevation, sinus-lift graft, inlay bone graft using Le Fort I osteotomy, and onlay graft have been used to create adequate bone volume in the maxillary sinus for placement of endosseous implants in the posterior atrophic maxilla. Because of the frequent lack of bone in the posterior maxilla, sinus lift procedure has become a commonly practiced treatment modality. The 138 endosseous implants of 36 patients with sinus augmentation procedures performed in Korea University Hospital from January 1991 to December 1998 were summarized and analysed. The result of this study were as follows: 1. Age ranged from 39 to 57, with a mean of 50.7. 2. The mean survival rate for 138 implants with maxillary sinus lift procedure was 80.4%. 3. There was no corelationship between the fixture length, width and the survival rate. 4. The result showed that the healing period for 8-12 months was necessary if the residual alveolar bone height was less than 5mm. 5. Autogenous iliac corticocancellous block graft showed the most favorable survival rate(95%).

  • PDF

The skeletal cortical anchorage using titanium microscrew implants (Titanium microscrew implant를 이용한 skeletal cortical anchorage)

  • Park, Hyo-Sang
    • The korean journal of orthodontics
    • /
    • v.29 no.6 s.77
    • /
    • pp.699-706
    • /
    • 1999
  • Anchorage plays an important role in orthodontic treatment. Endosseous implants may be considered adequate firm anchorage. However, clinicians have hesitated to use endosseous implants as orthodontic anchorage because of limited implantation space, high cost, and long waiting period before osseointegration occurs. Recently, some clinicians have tried to use titanium miniscrews and microscrews in treatment due to their many advantages such as ease of insertion and removal, low cost, immediate loading, and the ability to place microscrews in any area of alveolar bone. The author treated a case with skeletal cortical anchorage using titanium microscrew implants. During six months of orthodontic force application from skeletal cortical anchorage, the author could get 4 mm bodily retraction and intrusion of upper anterior teeth. The most outstanding result was a 1.5 mm posterior refraction of the upper posterior teeth. The titanium microscrew implants had remained firm and stable throughout treatment. These results indicate that skeletal cortical anchorage might be a very good option.

  • PDF

Three Dimensional Optimum Design of Endosseous Implant in Dentistry by Multilevel Response Surface Optimization (다단계 반응표면법을 이용한 치과용 임플란트의 3차원 형상최적설계)

  • Han, Jung-Suk;Kim, Jong-Soo;Choi, Joo-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.7
    • /
    • pp.940-947
    • /
    • 2004
  • In this paper, an optimum design problem for endosseous implant in dentistry is studied to find best implant design. An optimum design problem is formulated to reduce stresses arising at the cortical as well as cancellous bones, in which sufficient design parameters are chosen for design definition that encompasses major implants in popular use. Optimization at once (OAO) with the large number of design variables, however, causes too costly solution or even failure to converge. A concept of multilevel optimization (MLO) is employed to this end, which is to group the design variables of similar nature, solve the sub-problem of smaller size for each group in sequence, and this is iterated until convergence. Each sub-problem is solved based on the response surface method (RSM) due to its efficiency for small sized problem.

Mandibular Posterior Rehabilitation Case after Occlusal Plane Correction using Micro-Implant Anchorage (Micro-Implant를 이용한 교정치료로 교합평면 개선 후 하악 구치부 수복증례)

  • Park, Ju-Mi
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.20 no.2
    • /
    • pp.143-150
    • /
    • 2004
  • Endosseous implants have been used to provide anchorage control in orthodontic treatment without the need for special patient cooperation. However these implants have limitation like space requirement, cost, equipments. Recently titanium micro-implant for orthodontic anchorage was introduced. Micro-implants are small enough to place in any area of the alveolar bone, easy to implant and remove, and inexpensive. In addition, orthodontic force application can begin almost immediately after implantation. The mandibular first, maxillary first, mandibula second, and maxillary second molars were the four most commonly missing teeth in adult sample. In case of posterior molar teeth missing, deflective contacts in any position, over time, has produced pathologic change of occlusal scheme because of extrusion of opposing teeth. This case had interocclusal space deficiency by mandibular right molars missing over time. The micro-implants had been used for intrusion of maxillary right molars for interocclusal space. The micro-implant would be absolute anchorage for orthodontic movement. Therefore, the micro-implant would be effective method for correction of occlusal plane.

Effects of electrical stimulation on healing of endo-osseous titanium implants in circumferential defect (전기자극이 성견 골결손부에 매식된 임플란트 주위조직의 치유에 미치는 영향)

  • Shim, Jae-Chang;Kim, Young-Jun;Chung, Hyun-Ju;Kim, Ok-Su
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.1
    • /
    • pp.177-193
    • /
    • 2004
  • Several experimental studies showed that the application of small amounts of electric current to bone stimulated osteogenesis at the site of the cathode and suggested that electrical currents promote osseointegration around dental implants. The purpose of this study was to determine the effect of direct microcurrent to endosseous titanium implants placed in bone defects. The right and left 2nd, 3rd and 4th mandibular premolars in ten mongrel dogs (15Kg of weight) were extracted. One monthe later, Ti-machined screw type implants(3.8 mm diameter x 8.5 mm length, $AVANA^{(R)}$, Ostem) were placed in surgically created circumferential defect area(width 5mm, depth 4mm). The implants were divided into three groups according to the treatment modalities: Control group- implants without electrical stimulation; Experimental group I- implants with allogenic demineralized freeze dried bone grafting; and Experimental group II-implants allogenic demineralized freeze dried bone grafting and electric stimulation. The animals were sacrificed in the 4th and 8th week after implant placement and un-decalcified specimens were prepared for histological and histometrical evaluation of bone-implant contact ratio (BIC) and bone formation area ratio (BFA) in defect area. Some specimens at 8 weeks after implantation were used for removal torque testing. Histologically, there was connective tissue infiltration in the coronal part of defect area in control and the experimental group I, whereas direct bone contact was found in the experimental group II without connective tissue invasion. Average BIC ratios at 4 weeks of healing were 60.1% in the experimental group II, 47.4% in the experimental group I and 42.7% in the control. Average BIC ratios at 8 weeks after implantation were 67.6% in the experimental group II, 55.9% in the experimental group I and 54.6% in the control. The average BFA ratio was 84.0% in the experimental group II, 71.8% in the experimental group I and 58.8% in the control at 4 weeks, and the BFA ratios were 89.6% in the experimental group II, 81.4% in the experimental group I and 70.5% in the control at 8 weeks after implantation. The experimental group II showed also significantly greater BIC and BFA ratios compared to the control and the experimental group I (p<0.05). The removal torque values at 8 weeks after implantation were 56 Ncm in the experimental group II, 49 Ncm in the experimental group I and 43 Ncm in the control. There was a statistically significant difference among 3 groups (p<0.05). These results suggest that electrical stimulation improve and accelerate bone healing around endosseous titanium implants in bone defect.

Short Dental Implants : A Literature Review and Rationale for Use (Short Implant에 대한 문헌 고찰과 임상 적용)

  • Kim, Yu-Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.3
    • /
    • pp.287-292
    • /
    • 2009
  • The clinical use of several endosseous oral implants designs has become highly predictable in recent decades. Implant success critically depends both on the vertical and horizontal dimensions of the prospective host site and on the quality of the local bone. Implants shorter than 10 mm can be a long-term solution for sites with limited bone height. This article describes theoretical characteristics and clinical outcome of short implants through a medline search. When surgical preparation is related to bone density, textured-surfaced implants are employed, operators' surgical skills are developed, and indications for implant treatment duly considered, the survival rates for short implants has been found to be comparable with those obtained with longer implants.

The impact of the alveolar bone sites on early implant failure: a systematic review with meta-analysis

  • Fouda, Atef Abdel Hameed
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.46 no.3
    • /
    • pp.162-173
    • /
    • 2020
  • Dental implants are the first option for replacement of missing teeth. Failure usually involves additional cost and procedures. As a result, the physician should limit the risk factors associated with implant failures. Implant site is one of many factors that can influence the success or failure of dental implants. The association between early implant failure (EIF) and implant site has yet to be documented. This review aims to estimate the impact of insertion site on the percentage of EIFs. An electronic and manual search of studies that reported early failure of dental implants based on collection site. A total of 21 studies were included in the review and examined for the association between EIF and alveolar site. Subgroup analysis, including a comparison between implants inserted in four alveolar ridge regions of both jaws was performed. The early failure rate was higher for maxillary implants (3.14%) compared to mandibular implants (1.96%). Applying a random effect, risk ratio (RR), and confidence interval (CI) of 95% revealed higher failure in the maxilla compared to the mandible (RR 1.41; 95% CI [1.19, 1.67]; P<0.0001; I2=58%). The anterior maxilla is more critical for early implant loss than other alveolar bone sites. Implants in the anterior mandible exhibited the best success rate compared of the sites.

Optimum Design of Endosseous Implant in Dentistry by Multilevel Optimization Method (다단계 최적화 기법을 이용한 치과용 골내 임플란트의 형상 최적 설계)

  • Han, Jung-Suk;Seo, Ki-Youl;Choi, Joo-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.1
    • /
    • pp.144-151
    • /
    • 2003
  • In this paper, an optimum design problem for endosseous implant in dentistry is studied to find best implant design. An optimum design problem is formulated to reduce stresses arising at the cortical as well as cancellous bones, in which sufficient design parameters are chosen fur design definition that encompasses major implants in popular use. Optimization at once (OAO) with the large number of design variables, however, causes too costly solution or even failure to converge. A concept of multilevel optimization (MLO) is employed to this end, which is to group the design variables of similar nature, solve the sub-problem of smaller size fur each group in sequence, and this is iterated until convergence. Each sub-problem is solved based on the response surface method (RSM) due to its efficiency for small sized problem. Favorable solution is obtained by the MLO, which is compared to both solutions made by RSM and sequential quadratic programming (SQP) in the OAO problem.