• 제목/요약/키워드: Endoscopic ultrasound

검색결과 103건 처리시간 0.017초

22-gauge Co-Cr versus stainless-steel Franseen needles for endoscopic ultrasound-guided tissue acquisition in patients with solid pancreatic lesions

  • Yuki Tanisaka;Masafumi Mizuide;Akashi Fujita;Ryuhei Jinushi;Rie Shiomi;Takahiro Shin;Kei Sugimoto;Tomoaki Tashima;Yumi Mashimo;Shomei Ryozawa
    • Clinical Endoscopy
    • /
    • 제57권2호
    • /
    • pp.237-245
    • /
    • 2024
  • Background/Aims: Endoscopic ultrasound-guided tissue acquisition (EUS-TA) using Franseen needles is reportedly useful for its high diagnostic yield. This study compared the diagnostic yield and puncturing ability of EUS-TA using 22-gauge cobalt-chromium (CO-Cr) needles with those of stainless-steel Franseen needles in patients with solid pancreatic lesions. Methods: Outcomes were compared between the 22-gauge Co-Cr Franseen needle (December 2019 to November 2020; group C) and stainless-steel needle (November 2020 to May 2022; group S). Results: A total of 155 patients (group C, 75; group S, 80) were eligible. The diagnostic accuracy was 92.0% in group C and 96.3% in group S with no significant intergroup differences (p=0.32). The rate of change in the operator (from training fellows to experts) was 20.0% (15/75) in group C and 7.5% (6/80) in group S. Stainless-steel Franseen needles showed less inter-operator difference than Co-Cr needles (p=0.03). Conclusions: Both Co-Cr and stainless-steel Franseen needles showed high diagnostic ability. Stainless-steel Franseen needles are soft and flexible; therefore, the range of puncture angles can be widely adjusted, making them suitable for training fellows to complete the procedure.

Stereomicroscopic on-site evaluation in endoscopic ultrasound-guided tissue acquisition of upper gastrointestinal subepithelial lesions

  • Seigo Nakatani;Kosuke Okuwaki;Masafumi Watanabe;Hiroshi Imaizumi;Tomohisa Iwai;Takaaki Matsumoto;Rikiya Hasegawa;Hironori Masutani;Takahiro Kurosu;Akihiro Tamaki;Junro Ishizaki;Ayana Ishizaki;Mitsuhiro Kida;Chika Kusano
    • Clinical Endoscopy
    • /
    • 제57권1호
    • /
    • pp.89-95
    • /
    • 2024
  • Background/Aims: In stereomicroscopic sample isolation processing, the cutoff value (≥4 mm) of stereomicroscopically visible white cores indicates high diagnostic sensitivity. We aimed to evaluate endoscopic ultrasound-guided tissue acquisition (EUS-TA) using a simplified stereomicroscopic on-site evaluation of upper gastrointestinal subepithelial lesions (SELs). Methods: In this multicenter prospective trial, we performed EUS-TA using a 22-gauge Franseen needle in 34 participants with SELs derived from the upper gastrointestinal muscularis propria, requiring pathological diagnosis. The presence of stereomicroscopically visible white core (SVWC) in each specimen was assessed using stereomicroscopic on-site evaluation. The primary outcome was EUS-TA's diagnostic sensitivity with stereomicroscopic on-site evaluation based on the SVWC cutoff value (≥4 mm) for malignant upper gastrointestinal SELs. Results: The total number of punctures was 68; 61 specimens (89.7%) contained stereomicroscopically visible white cores ≥4 mm in size. The final diagnoses were gastrointestinal stromal tumor, leiomyoma, and schwannoma in 76.5%, 14.7%, and 8.8% of the cases, respectively. The sensitivity of EUS-TA with stereomicroscopic on-site evaluation based on the SVWC cutoff value for malignant SELs was 100%. The per-lesion accuracy of histological diagnosis reached the highest level (100%) at the second puncture. Conclusions: Stereomicroscopic on-site evaluation showed high diagnostic sensitivity and could be a new method for diagnosing upper gastrointestinal SELs using EUS-TA.

Comparison of 19-gauge conventional and Franseen needles for the diagnosis of lymphadenopathy and classification of malignant lymphoma using endoscopic ultrasound fine-needle aspiration

  • Mitsuru Okuno;Keisuke Iwata;Tsuyoshi Mukai;Yusuke Kito;Takuji Tanaka;Naoki Watanabe;Senji Kasahara;Yuhei Iwasa;Akihiko Sugiyama;Youichi Nishigaki;Yuhei Shibata;Junichi Kitagawa;Takuji Iwashita;Eiichi Tomita;Masahito Shimizu
    • Clinical Endoscopy
    • /
    • 제57권3호
    • /
    • pp.364-374
    • /
    • 2024
  • Background/Aims: Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) using a 19-gauge needle is an efficient sampling method for the diagnosis of lymphadenopathy. This study compared 19-gauge conventional and Franseen needles for the diagnosis of lymphadenopathy and classification of malignant lymphoma (ML). Methods: Patient characteristics, number of needle passes, puncture route, sensitivity, specificity, and accuracy of cytology/histology for lymphadenopathy were analyzed in patients diagnosed with lymphadenopathy by EUS-FNA using conventional or Franseen needles. Results: Between 2012 and 2022, 146 patients met the inclusion criteria (conventional [n=70] and Franseen [n=76]). The median number of needle passes was significantly lower in the conventional group than in the Franseen group (3 [1-6] vs. 4 [1-6], p=0.023). There were no significant differences in cytological/ histological diagnoses between the two groups. For ML, the immunohistochemical evaluation rate, sensitivity of flow cytometry, and cytogenetic assessment were not significantly different in either group. Bleeding as adverse events (AEs) were observed in three patients in the Franseen group. Conclusions: Both the 19-gauge conventional and Franseen needles showed high accuracy in lymphadenopathy and ML classification. Considering sufficient tissue collection and the avoidance of AEs, the use of 19-gauge conventional needles seems to be a good option for the diagnosis of lymphadenopathy.

Clinical utility of endoscopic ultrasound-guided tissue acquisition for comprehensive genomic profiling of patients with biliary tract cancer, especially with intrahepatic cholangiocarcinoma

  • Takafumi Yanaidani;Kazuo Hara;Nozomi Okuno;Shin Haba;Takamichi Kuwahara;Yasuhiro Kuraishi;Nobumasa Mizuno;Sho Ishikawa;Masanori Yamada;Tsukasa Yasuda
    • Clinical Endoscopy
    • /
    • 제57권3호
    • /
    • pp.384-392
    • /
    • 2024
  • Background/Aims: Endoscopic ultrasound-guided tissue acquisition (EUS-TA) is a standard diagnostic method for biliary tract cancer (BTC), and samples obtained in this manner may be used for comprehensive genomic profiling (CGP). This study evaluated the utility of EUS-TA for CGP in a clinical setting and determined the factors associated with the adequacy of CGP in patients with BTC. Methods: CGP was attempted for 105 samples from 94 patients with BTC at the Aichi Cancer Center, Japan, from October 2019 to April 2022. Results: Overall, 77.1% (81/105) of the samples were adequate for CGP. For 22-G or 19-G fine-needle biopsy (FNB), the sample adequacy was 85.7% (36/42), which was similar to that of surgical specimens (94%, p=0.45). Univariate analysis revealed that 22-G or larger FNB needle usage (86%, p=0.003), the target primary lesions (88%, p=0.015), a target size ≥30 mm (100%, p=0.0013), and number of punctures (90%, p=0.016) were significantly positively associated with CGP sample adequacy. Conclusions: EUS-TA is useful for CGP tissue sampling in patients with BTC. In particular, the use of 22-G or larger FNB needles may allow for specimen adequacy comparable to that of surgical specimens.

Endoscopic Resection of Xanthogranulomatous Gastritis Presenting as a Subepithelial Tumor: A Case Report

  • Kim, Tae Wan;Kim, Tae Ho;Kim, Chang Whan;Chang, Jae Hyuck;Han, Sok Won;Kim, Jae Kwang
    • 대한상부위장관⦁헬리코박터학회지
    • /
    • 제18권3호
    • /
    • pp.198-203
    • /
    • 2018
  • Xanthogranulomatous gastritis (XGG) presenting as a subepithelial tumor (SET) is a very rare entity. We report a case of SET-like XGG diagnosed and treated with endoscopic resection. A 55-year-old female patient was initially referred with a 1.5-cm SET located at the anterior wall of the middle antrum. Endoscopic ultrasound examination revealed submucosal invasion without any perigastric lymph node enlargement. Endoscopic resection was performed for an accurate diagnosis and treatment, and the lesion was diagnosed histopathologically as XGG. At the 18-month follow-up after endoscopic resection, there was no evidence of XGG recurrence. SET-like XGG is very rare and the diagnosis is a preoperative challenge. However, inflammatory tumors should be considered in the differential diagnosis of SET.

Role of Endoscopic Ultrasound-Guided Fine-Needle Aspiration in the Evaluation of Abdominal Lymphadenopathy of Unknown Etiology

  • Nonthalee Pausawasdi;Kotchakon Maipang;Tassanee Sriprayoon;Phunchai Charatcharoenwitthaya
    • Clinical Endoscopy
    • /
    • 제55권2호
    • /
    • pp.279-286
    • /
    • 2022
  • Background/Aims: Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is a standard procedure for obtaining tissue from lesions near the gastrointestinal lumen. However, there is a scarcity of information on the diagnostic performance of EUS-FNA for abdominal lymphadenopathy of unknown causes. To assess the accuracy of EUS-FNA in diagnosing abdominal lymphadenopathy of unknown etiology. Methods: The EUS records of patients with undiagnosed abdominal lymphadenopathy between 2010 and 2015 were reviewed. Results: A total of 42 patients were included in this study. Adequate specimens were obtained from 40 patients (95%). The final diagnoses were metastatic cancer (n=16), lymphoma (n=9), tuberculosis (n=8), inflammatory changes (n=6), and amyloidosis (n=1). For diagnosing malignancy, EUS-FNA had a sensitivity of 84.6%, specificity of 95.7%, positive predictive value of 91.7%, negative predictive value of 91.7%, and area under the receiver operating characteristic curve (AUROC) of 0.901. For the diagnosis of lymphoma, EUS-FNA was 100% accurate when combined with cytologic evaluation and immunohistochemical staining. The diagnostic sensitivity decreased to 75%, whereas the specificity remained 100%, for tuberculosis. The overall AUROC was 0.850. No procedure-related complications occurred. Conclusions: EUS-FNA showed high diagnostic performance for abdominal lymphadenopathy of unknown causes, especially malignancy, lymphoma, and tuberculosis. Therefore, it is a crucial diagnostic tool for this patient population.

양성 소장협착의 내시경적 진단과 치료 (Endoscopic Diagnosis and Treatment of Benign Small Bowel Stricture)

  • 김진수
    • The Korean Journal of Medicine
    • /
    • 제99권4호
    • /
    • pp.199-205
    • /
    • 2024
  • Benign small bowel strictures can occur in association with various conditions, including small bowel Crohn's disease, nonsteroidal anti-inflammatory drug-induced enteritis, ischemic enteritis, intestinal tuberculosis, radiation enteritis, postoperative adhesions, and anastomotic strictures. Benign small bowel strictures are classified into two categories, low-grade and high-grade. Low-grade small bowel strictures involve a partial reduction of the internal diameter of the small intestine, causing slight obstruction of the passage of food and digestive fluids without significant bowel obstruction symptoms. By contrast, high-grade small bowel strictures involve a severe narrowing of the intestinal lumen, leading to marked obstruction of the passage of food and digestive fluids and pronounced bowel obstruction symptoms. Small bowel strictures can be diagnosed using various methods, including abdominal plain radiography, abdominal computed tomography, computed tomography enterography, magnetic resonance enterography, balloon-assisted enteroscopy, and abdominal ultrasound. Each diagnostic method has unique advantages and disadvantages as well as differences in diagnostic specificity and sensitivity. Therefore, even if small bowel strictures are not observed using a single imaging technique, their presence cannot be completely excluded. A comprehensive diagnosis that combines clinical information from multiple diagnostic modalities is necessary. Therapeutic approaches for managing small bowel strictures include medical therapy, endoscopic balloon dilation using balloon-assisted enteroscopy, and surgical methods such as strictureplasty and segmental resection. Endoscopic balloon dilation, in particular, can help reduce complications associated with repeated surgeries for strictures.