• Title/Summary/Keyword: EndoCrown

Search Result 12, Processing Time 0.025 seconds

DFT Study of p-tert-Butylcalix[5]crown-6-ether Complexed with Alkylammonium Ions

  • Oh, Dong-Suk;Choe, Jong-In
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.4
    • /
    • pp.596-600
    • /
    • 2007
  • The structures and energies of p-tert-butylcalix[5]crown-6-ether (1) and its alkylammonium complexes have been calculated by DFT B3LYP/6-31G(d,p) method. We have studied the binding sites of these host-guest complexes focusing on the p-tert-butylcalix[5]arene pocket (endo) or the crown-6-ether moiety (exo) of 1. The smaller alkylammonium cations have the better complexation efficiency with p-tert-butylcalix[5]crown-6- ether than the bulkier alkylammonium ions. For the sec- and tert-butylammonium ions, the hydrogen-bond distances of the exo-complexes are shorter, therefore, stronger than the endo-cases. This DFT calculated result is in parallel with the trend of the experimental association constants of the branched butylammonium ions.

Does apical root resection in endodontic microsurgery jeopardize the prosthodontic prognosis?

  • Cho, Sin-Yeon;Kim, Euiseong
    • Restorative Dentistry and Endodontics
    • /
    • v.38 no.2
    • /
    • pp.59-64
    • /
    • 2013
  • Apical surgery cuts off the apical root and the crown-to-root ratio becomes unfavorable. Crown-to-root ratio has been applied to periodontally compromised teeth. Apical root resection is a different matter from periodontal bone loss. The purpose of this paper is to review the validity of crown-to-root ratio in the apically resected teeth. Most roots have conical shape and the root surface area of coronal part is wider than apical part of the same length. Therefore loss of alveolar bone support from apical resection is much less than its linear length.The maximum stress from mastication concentrates on the cervical area and the minimum stress was found on the apical 1/3 area. Therefore apical root resection is not so harmful as periodontal bone loss. Osteotomy for apical resection reduces longitudinal width of the buccal bone and increases the risk of endo-perio communication which leads to failure. Endodontic microsurgery is able to realize 0 degree or shallow bevel and precise length of root resection, and minimize the longitudinal width of osteotomy. The crown-to-root ratio is not valid in evaluating the prosthodontic prognosis of the apically resected teeth. Accurate execution of endodontic microsurgery to preserve the buccal bone is essential to avoid endo-perio communication.

A COMPARISON OF THE IRRIGATION SYSTEMS IN CALCIUM HYDROXIDE REMOVAL (근관세정 방법에 따른 수산화칼슘 제재의 제거 효율 비교)

  • Eun, Jae-Seung;Park, Se-Hee;Cho, Kyung-Mo;Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.6
    • /
    • pp.508-514
    • /
    • 2009
  • The purposes of this study were to compare the efficacy of irrigation systems by removing a calcium hydroxide $(Ca(OH)_2)$ paste from the apical third of the root canal and the effect of the patency file. Sixty single rooted human teeth were used in this study. The canals were instrumented by a crown-down manner with .04 taper ProFile to ISO #35. $Ca(OH)_2$ and distilled water were mixed and placed inside the root canals. The teeth were divided into 6 groups according to the root canal irrigation system and the use of patency file as follows: group 1 - conventional method: group 2 - $EndoActivator^{(R)}$: group 3 - $EndoVac^{(R)}$; group 4 - conventional method, patency: group 4 - $EndoActivator^{(R)}$, patency; group 6 - $EndoVac^{(R)}$, patency. All teeth were irrigated with sodium hypochlorite. After the root canal irrigation, the teeth were split in bucco-lingual aspect. Percentage of the root canal surface coverage with residual $Ca(OH)_2$ until 3 mm from working length was analyzed using Image Pro Plus ver. 4.0. Statistical analysis was performed using the One-way ANOVA, t-test and Scheffe's post-hoc test. Conventional groups had significantly more $Ca(OH)_2$ debris than $EndoActivator^{(R)}$, $EndoVac^{(R)}$ groups. There was no significant difference between $EndoActivator^{(R)}$ and $EndoVac^{(R)}$ groups. Groups with patency file showed more effective in removing $Ca(OH)_2$ paste than no patency groups. but. it was no significant difference. This study showed that $EndoActivator^{(R)}$ and $EndoVac^{(R)}$ systems were more effective in removing $Ca(OH)_2$ paste from the apical third of the root canal than conventional method.

EVALUATION OF ENTEROCOCCUS FAECALIS REMOVAL EFFICACY OF THE ENDOVAC® AND ENDOACTIVATOR® INTRACANAL IRRIGATION METHODS (EndoVac®과 EndoActivator®를 이용한 근관세척법의 Enterococcus faecalis 제거 효율 평가)

  • Song, Seung-Gon;Park, Se-Hee;Cho, Kyung-Mo;Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.5
    • /
    • pp.390-396
    • /
    • 2009
  • The aim of this study was to evaluate endodontic irrigation methods with $EndoVac^{(R)}$ and $EndoActivator^{(R)}$ in the elimination of Enterococcus faecalis from the root canals. Extracted 70 human single-rooted teeth were used. The canals were instrumented by a crown-down technique with .04 taper ProFile to ISO size 40. After the teeth were autoclaved, the canals were inoculated with E. faecalis and incubated for 48 h. The teeth were randomly divided into three experimental groups of 20 teeth each according to canal irrigation methods and two control groups as follows: group 1 - $EndoVac^{(R)}$; group 2 - $EndoActivator^{(R)}$; group 3-Conventional needle irrigation method. After canal irrigation using 2.5% NaOCl. first samples (S1) were taken using sterile paper point. And the canals were filled with sterile brain heart infusion (BHI) broth and incubated for 24 h, then second samples (S2) were taken. The samples were cultured on BHI agar plate to determine the numbers of colony forming units (CFU). In first sampling (S1), only one canal of conventional method among the all experimental groups was positive cultured. In second sampling (S2), $EndoVac^{(R)}$ group showed the least positive culture numbers of E. faecalis. There was statistically significant difference between the $EndoVac^{(R)}$ and conventional needle irrigation methods in the mean value of Log CFU. According to the results of this study, $EndoVac^{(R)}$ showed better efficacy than conventional needle irrigation method in the elimination of E. faecalis from the root canal.

DFT Study for Azobenzene Crown Ether p-tert-Butylcalix[4]arene Complexed with Alkali Metal Ion

  • Park, Seong-Jun;Choe, Jong-In
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.3
    • /
    • pp.541-545
    • /
    • 2008
  • Stable molecular isomers were calculated for the azobenzene crown ether p-tert-butylcalix[4]arene (1) in the host and their alkali-metal-ion complexes. The structures of two distinct isomers (cis and trans) have been optimized using DFT B3LYP/6-31G(d,p) method. Trans isomer of 1 is found to be 11.69 kcal/mol more stable than cis analogue. For two different kinds of complexation mode, the alkali-metal-cation in the crown-ether moiety (exo) has much better complexation efficiency than in the benzene-rings (endo) pocket for both isomers of 1. Sodium ion has much better complexation efficiency than potassium ion in all kinds of complexation mode with host 1. The Na+ complexation efficiency of the trans-complex (1) in the exo-binding mode is 8.24 kcal/mol better than cis-exo analogue.

STRESS DISTRIBUTION OF ENDODONTICALLY TREATED MAXILLARY SECOND PREMOLARS RESTORED WITH DIFFERENT METHODS: THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS (상이한 방법으로 수복한 근관치료된 상악 제2소구치의 응력분포: 3차원 유한요소법적 분석)

  • Lim, Dong-Yeol;Kim, Hyeon-Cheol;Hur, Bock;Kim, Kwang-Hoon;Son, Kwon;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.1
    • /
    • pp.69-79
    • /
    • 2009
  • The purpose of this study was to evaluate the influence of elastic modulus of restorative materials and the number of interfaces of post and core systems on the stress distribution of three differently restored endodontically treated maxillary second premolars using 3D FE analysis. Model 1, 2 was restored with a stainless steel or glass fiber post and direct composite resin. A PFG or a sintered alumina crown was considered. Model 3 was restored by EndoCrown. An oblique 500 N was applied on the buccal (Load A) and palatal (Load B) cusp. The von Mises stresses in the coronal and root structure of each model were analyzed using ANSYS. The elastic modulus of the definitive restorations rather than the type of post and core system was the primary factor that influenced the stress distribution of endodontically treated maxillary premolars. The stress concentration at the coronal structure could be lowered through the use of definitive restoration of high elastic modulus. The stress concentration at the root structure could be lowered through the use of definitive restoration of low elastic modulus.

ESTIMATION OF PHYSICAL PARAMETERS OF INDIVIDUAL TREES BY LIDAR DATA

  • ENDO TAKAHIRO;TERAOKA MASAKI;JYOTI BARUAH PRANAB;SETOJIMA MASAHIRO;KATSURA TORU;YASUOKA YOSHIFUMI
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.522-525
    • /
    • 2005
  • Light detection and ranging (LIDAR) is one of the effective technologies for monitoring forest inventory, and importance of forestry is increasing because of its function as the sink of green house gases (GHG). This study aims at development of a methodology for better and more accurate estimation of physical parameters of individual trees by removing sudden drops of LIDAR data within a crown. Our study area is located in Aomori prefecture, the northern part of Honshu Island, with the dominant species of Japanese cedar. The results show practicality of our method in the usage of LIDAR data in the field of forest inventory.

  • PDF

Comparison of shaping ability between single length technique and crown-down technique using Mtwo rotary file (Mtwo 전동 파일을 사용한 single length technique과 crown-down technique의 근관성형 효율 비교)

  • Lim, Yoo-Kyoung;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.4
    • /
    • pp.385-396
    • /
    • 2007
  • The aims of this study were to compare the shaping effect and safety between single length technique recommended by manufacturer and crown-down technique using Mtwo rotary file and to present a modified method in use of Mtwo file. Sixty simulated root canal resin blocks were used. The canals were divided into three groups according to instrument and the manner of using methods. Each group had 20 specimens. Group MT was instrumented with single length technique of Mtwo, group MC was instrumented with crown-down technique of Mtwo and group PT was instrumented with crown-down technique of ProTaper. All of the rotary files used in this study were operated by an electric motor. The scanned canal images of before and after preparation were superimposed. These superimposed images were evaluated at apical 1 to 8 mm levels Angle changes were calculated. The preparation time, weight loss, instrument failure and binding, canal aberrations, and centering ratio were measured. Statistical analysis of the three experimental groups was performed with ANOVA and Duncan's multiple range tests for post-hoc comparison and Fisher's exact test was done for the frequency comparison. In total preparation time, group MT and group MC were less than group PT. In the aberrations, group MT had more elbows than those of group MC and group PT. The binding of group MC was least and group MT was less than group PT (P < 0.05). Under the condition of this study, crown-down technique using Mtwo rotary file is better and safer method than single length technique recommended by the manufacturer.

A Study on the Shaping Ability of Three Different Rotary Nickel-Titanium Instruments in Simulated Curved Root Canal (만곡 근관에서 다양한 엔진 구동형 Nickel-Titanium 파일의 근관 성형능력에 대한 연구)

  • Kim, Kyoung-A;Chon, Seong-Min;Kwon, Su-Mi;Lee, Kwang-Won;Yu, Mi-Kyung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.4
    • /
    • pp.293-302
    • /
    • 2007
  • I. Objectives The purpose of this study was to compare the shaping ability between the single length technique performed with Mtwo instruments (VDW, Munich, Germany) and the crown-down technique using K3 (SybronEndo, West Collins, CA, USA) and RaCe (FKG, La Chaux-de-Fonds, Switzerland) instruments. II. Materials & Methods Forty five curved canals in resin blocks were equally divided in to three groups. Group 1 (Mtwo) was instrumented used the full length of canal according to the manufacturer's instructions. The simulated canals was prepared to an instrument size of 35, 0.04 taper canal terminus. In group 2 (Race) and group 3 (K3) was instrumented in a crown-down manner and prepared to an instrument size of 30, 0.06 taper canal terminus. Pre- and post-instrumentation images were scanned and assessment of canal shape was completed with a computer image analysis program. Material removal was measured at 7 measuring points, beginning 1mm from the end point of preparation. Differenced of centering ratio were statistically analyzed using One-way ANOVA followed by Duncan's test. II. Results & Conclusion There was no significant difference on 1, 2, 3 and 7mm measuring point. At 4 and 5 measuring point, significant difference showed between the Mtow instruments and other two instruments. (p<0.05)

A STUDY OF INSERTION DEPTH OF GUTTA PERCHA CONES AFTER SHAPING BY NI-TI ROTARY FILES IN SIMULATED CANALS (레진모형 근관에서 Ni-Ti 파일로 근관성형 후 거타퍼챠콘의 근관내 삽입깊이에 대한 연구)

  • Cho, Hyun-Gu;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.6
    • /
    • pp.550-558
    • /
    • 2007
  • The purpose of this study was to evaluate the insertion depth of several brands of master gutta percha cones after shaping by various Ni-Ti rotary files in simulated canals. Fifty resin simulated J-shape canals were instrumented with ProFile, ProTaper and HEROShaper. Simulated canals were prepared with ProFile .04 taper #25(n=10), .06 taper #25(n=10), ProTaper F2(n=10), HEROShaper .04 taper #25(n=10) and .06 taper #25(n=10). Size #25 gutta percha cones with a .04 & .06 taper from three different brands were used: DiaDent; META; Sure-endo. The gutta percha cones were selected and inserted into the prepared simulated canals. The distance from the apex of the prepared canal to the gutta percha cone tip was measured by image analysis program. Within limited data of this study, the results were as follows 1. When the simulated root canals were prepared with HEROShaper, gutta-percha cones were closely adapted to the root canal. 2. All brands of gutta percha cones fail to go to the prepared length in canal which was instrumented with ProFile, the cones extend beyond the prepared length in canal which was prepared with ProTaper. 3. In canal which was instrumented with HEROShaper .04 taper #25, Sure-endo .04 taper master gutta percha cone was well fitted(p < 0.05). 4. In canal which was instrumented with HEROShaper .06 taper #25, META .06 taper master gutta percha cone was well fitted(p < 0.05). As a result, we concluded that the insertion depth of all brands of master gutta percha cone do not match the rotary instrument, even though it was prepared by crown-down technique, as recommended by the manufacturer. Therefore, the master cone should be carefully selected to match the depth of the prepared canal for adequate obturation.