• 제목/요약/키워드: Enamel shade composite

검색결과 7건 처리시간 0.023초

색상 측정 기기를 이용한 복합레진 적층 수복과 단일 수복의 색상 비교 분석 (Colorimetric comparison of single layered dental composite with double layered dental composite)

  • 송영상;김자현;이빈나;장지현;장훈상;황윤찬;오원만;황인남
    • Restorative Dentistry and Endodontics
    • /
    • 제37권2호
    • /
    • pp.84-89
    • /
    • 2012
  • Objectives: This study analyzed the difference in color caused by different thickness in enamel layer of composite resins when applied with single and layering placement technique, and evaluated if the results agreed with the shade guide from the manufacturers to verify reliability of the color matching process of the manufacturers. Materials and Methods: For single composite resin samples, 6 mm diameter and 4 mm thickness cylindrical samples were fabricated using Ceram-X mono (DENTSPLY DeTrey) and CIE $L^*a^*b^*$ values were measured with spectrophotometer. Same process was done for layering composite resin samples, making 3 dentinal shade samples, 4 mm thickness, for each shade using Ceram-X duo (DENTSPLY DeTrey) and enamel shade resins were layered in 2 mm thickness and CIE $L^*a^*b^*$ values were measured. These samples were ground to 0.2 mm thickness each time, and CIE $L^*a^*b^*$ values were measured to 1 mm thickness of enamel shade resin. Results: Color difference (${\Delta}E^*$) between single and layering composite resin was 1.37 minimum and 10.53 maximum when layering thicknesses were between 1 mm and 2 mm and 6 out of 10 same shade groups suggested by manufacturer showed remarkable color difference at any thickness (${\Delta}E^*$ > 3.3). Conclusion: When using Ceram-X mono and duo for composite resin restoration, following the manufacturer's instructions for choosing the shade is not appropriate, and more accurate information for Ceram-X duo is needed on the variation and expression of the shades depending on the thickness of the enamel.

직접수복용 레진과 기공용 레진으로 제작한 레진 인레이를 투과한 광중합기의 광강도 (Power density of light curing units through resin inlays fabricated with direct and indirect composites)

  • 장훈상;임영준;김정미;홍성옥
    • Restorative Dentistry and Endodontics
    • /
    • 제35권5호
    • /
    • pp.353-358
    • /
    • 2010
  • 연구목적: 본 연구는 직접수복용 레진 (Filtek Z350, Supreme XT)과 기공용 레진 (Sinfony)으로 제작한 레진 인레이를 투과하는 광중합기의 광강도를 측정하고 레진 인레이를 구성하는 색조에 따라 투과되는 광강도를 측정하였다. 연구 재료 및 방법: A3 색조의 레진 인레이를 Z350 A3 한 가지 색조로 제작한 것과 Supreme XT A3B와 A3E 두 가지 색조로 제작한 것을 이용하였으며 Sinfony는 제조사의 지시에 따라 A3, E3, T1 세 가지 색조로 제작하였고 두께는 1.5 mm로 통일하였다. 할로겐 광중합기 (Optilux 360)와 LED 광중합기 (Elipar S10)를 이용하여 레진 인레이를 투과하는 광강도를 휴대용 광강도 측정기 (Cure Rite)로 측정하였다. 각 레진의 색조가 광강도의 투과에 미치는 영향을 분석하기 위해 0.5mm 두께로 레진 시편을 제작하여 광강도를 측정하였다. 결과: Z350 A3로 제작한 레진 인레이를 투과한 광강도가 가장 낮았으며, 다음으로 Supreme XT A3B와 A3E로 제작한 레진 인레이, 그리고 Sinfony A3, E3, T1으로 제작한 레진 인레이 순으로 광강도가 유의하게 증가하였다 (p < 0.05). 0.5mm의 레진 시편을 투과한 광강도를 측정한 결과 dentin shade인 Sinfony A3, Z350 A3, Supreme XT A3B가 가장 낮았으며, enamel shade인 Supreme XT A3E, Sinfony E3, 그리고 translucent shade인 Sinfony T1 순으로 유의하게 증가하였다 (p < 0.05). 결론: 레진 인레이를 제작할 경우 단색의 직접 수복용 레진을 사용하기 보다는 기공용 레진의 dentin shade, enamel shade, translucent shade를 모두 사용하는 것이 레진 인레이 하방으로 더 많은 중합광을 투과시킬 수 있는 것으로 사료된다.

복합레진의 조건등색에 관한 연구 (METAMERISM IN COMPOSITE RESINS UNDER FIVE STANDARD ILLUMINANTS - D65, A, C, FCW AND TL84)

  • 박기정;황윤찬;김선호;오원만;황인남
    • Restorative Dentistry and Endodontics
    • /
    • 제28권5호
    • /
    • pp.402-408
    • /
    • 2003
  • This study was done to present a criterion in selection of the most proper light sources and materials by measuring metamerism index(MI) of the light curing composite resins with spectrocolorimeter. Metamerism is defined when two objects appear to be the same color in one illuminant but different in another. This is due to the fact that they have different spectral curves that fail to match under the second illuminant. In this study, A1 & A3 shade of five light curing composite resins (Esthet-X, Filteck Z250, Filteck A110. Charisma. Vitalescence) were chosen based on Vita shade. Five samples were made for shade of each product with Teflon mold (diameter: 15mm, thickness: 2mm). Metamerism index of each samples on a Barium sulfate plate($L^{*}=96.54,{\;}a^{*}=0.19,{\;}b^{*}=0.01$) prepared for sample fixation were measured with spectrocolorimeter(Miniscan XE plus. Model 4000s. Hunter Lab. USA) by applying standard light source D^{65}, C. Fcw, TL84 and A. Standardization was done with reference standard(X=80.8, Y=85.7, Z=90.8) and light trap. The results were as follows. 1. Different resins with same Vita shade showed recognizable color difference (${\delta}E^{*}>2$). 2. All composites had MI below accepted value 0.5 between standard illuminant(D$_{65}$, C, & A) and below 1.5 under fluorescent condition (Fcw & TL84). 3. MI value between $D^{65}$ and A showed higher value than MI value between other source of light(p<0.01). 4. All resins except Z250 showed MI value that A3 is higher than A1 between $D^{65}$ and A(p<0.05).except Z250 showed MI value that A3 is higher than A1 between $D^{65}$ and A(p<0.05).

광중합복합레진의 두께에 따른 투명도 차이가 수복물의 색상에 미치는 영향 (TRANSLUCENCY OF LIGHT CURED COMPOSITE RESINS DEPENDS ON THICKNESS & ITS INFLUENCE ON COLOR OF RESTORATIONS)

  • 황인남;이광원
    • Restorative Dentistry and Endodontics
    • /
    • 제24권4호
    • /
    • pp.585-603
    • /
    • 1999
  • Esthetic availabilities used as an esthetic restorative maternals can be determined by the optical coincidence among materials, enamel and dentin. Enamel is highly translucent. That's why esthetic materials need to correspond the close translucency of enamel. But the translucent materials are affected by the background color. So it should be predicted that the color of estorative materials depend on the any thickness and the spectral reflectance of the background on which they are placed. The object of this investigation, under above hypothesis, was to determine and analyze how they affect the final color according to the thickness, translucency and background color (white, black and dentin) fill three commercial light cured composite resins(Charisma, Spectrum TPH and Z100). And correlation was analyzed to find out the possibility of the prediction when using the certain background color and thickness of materials. Followings are the result 1. The I shade of CHA showed the lowest contrast ratio($Co_7$) while the B3 shade of Z100 showed the highest contrast ratio(p<0.05). 2. The value of $L^*$ and $b^*$ on the white and dentin background is increased with decreasing thickness. And there are significant relationships between increasing thickness and each value(R>0.085). But there is a little change of $L^*$ and $b^*$ value on the black background regardless of the thickness(p>0.05). 3. For the $a^*$ value, there was little difference in values as a function of thickness and changed irregularly regardless of thickness in all background. 4. The pattern of increasing value of $L^*$ and $b^*$ with decreasing thickness was similar to the group of white and dentin background. In both dentin one showed lesser change of value. 5. The values of $L^*a^*b^*$ measured on the different background with same thickness showed the recognizable color difference(${\Delta}E^*$>2) when the thickness was below 2.6mm. 6. Contrast ratio was increased with increasing thickness with significant relationship (R>0.9). 7. Spectral reflectance of composite resins that calculated from Kubelka-Munk equation was showed little difference compared with observed value w1th decreasing thickness.

  • PDF

광중합 복합레진 수복시 여러 광조사 방법에 따른 미세변연누출에 관한 연구 (MICROLEAKAGE OF CL V COMPOSITE RESTORATIONS USING VARIOUS LIGHT CURING METHODS)

  • 양철영;유현미;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제25권2호
    • /
    • pp.299-308
    • /
    • 2000
  • The purpose of this in vitro study was to evaluate the microleakage of 5 curing methods in class V composite restorations which are composed of two-step light curing, pulse-delay cure, low curing-light intensity, moderate curing-light intensity and high curing-light intensity. In this study, class V cavities were prepared on buccal and lingual surfaces of 50 extracted human upper or lower molars on cementum margin. Single Bond adhesive and Z-100 shade A2 were applied for each group following the manufacture's instruction. The experimental teeth were randomly divided into 5 groups of 10 samples (20 surfaces) each. Group 1: two-step light curing; Group 2: pulse-delay cure; Group 3: low curing-light intensity; Group 4: moderate curing-light intensity; Group 5: high curing-light intensity. After 500 thermocycling between $5^{\circ}C$ and $55^{\circ}C$, the 60 teeth were placed in 2% methylene blue dye for 24 hours, then rinsed with tab water. The specimens were embedded in clear resin, then sectioned buccolingually through the center of restoration with a low speed diamond saw. The dye penetration on each of the specimen was then observed with a stereomicroscope at ${\times}20$. The composite resin/tooth interfaces were examined under Scanning Electron Microscopy. The results were statistically analyzed using the Kruskal-Wallis One Way ANOVA and Dunn's Method. The results of this study were as follows. 1. In all groups, the leakage values seen at the enamel margin were significantly lower than those seen at the dentin margin(P<0.05). 2. No group in this study showed significant differences in leakage values at both the enamel and the dentin margins(P<0.05). 3. In all groups, the gaps seen at the enamel margin were significantly lower than those seen at the dentin margin(P<0.05). 4. The gaps in this study showed significant differences and two-step light-curing and low curing-light intensity produced significant less gap than high curing-light intensity(P<0.05).

  • PDF

광중합형 복합레진의 중합 전, 후의 색 성분이 중합률과 굴곡강도에 미치는 영향 (Effects of the color components of light-cured composite resin before and after polymerization on degree of conversion and flexural strength)

  • 유지아;조병훈
    • Restorative Dentistry and Endodontics
    • /
    • 제36권4호
    • /
    • pp.324-335
    • /
    • 2011
  • 연구목적: 복합레진의 색조를 색 성분요소인 CIE $Lab^*$ 각 성분요소로 측정하고, 동일 시편에 대해서 중합률과 2축 굴곡강도(biaxial flexural strength)를 측정하여 이들의 상관관계를 비교함으로써 복합레진의 중합전, 후의 색 성분요소가 중합률과 물성에 미치는 영향을 알아보고자 하였다. 연구 재료 및 방법: 두 종류의 복합레진 Premisa (Kerr Co.)와 Denfil (Vericom Co)의 법랑질 색조(A1, A2, A3, A4)와 상아질 색조(A2O, A3O)에 대해 원판형의 시편을 제작하여 색성분, 중합률 및 2축 굴곡강도를 측정하였다. 분광광도계를 이용하여 중합 전, 후 및 7일에 CIE $L^*,\;a^*,\;b^*$ 값을 측정하고, 같은 시편에 대해 근적외선분광기를 이용하여 중합 후 2시간과 7일에 중합률을 측정하였다. 중합 7일 후에 색 성분과 중합률을 측정한 후 만능시험기에서 2축 굴곡강도를 측정하였다. 색요소인 CIE $L^*,\;a^*,\;b^*$ 각각의 값과 중합률, 및 2축 굴곡강도의 상관관계를 분석하였다. 결과: 두 종의 광중합형 복합레진은 중합 전과 후에 색 성분요소, 즉 색조의 변화가 있었고, 광중합 후에도 시간이 경과하면서 중합률이 증가되었다. 중합률은 제품, 기간, 및 색조의 영향을 받고(3-way ANOVA, p < 0.05), 굴곡강도는 제품 및 색조의 영향을 받았다(2-way ANOVA, p < 0.05). 중합률은 Premisa 한 제품에서만 중합 전, 후의 CIE $a^*$ component와 유의한 상관관계를 보였고, 굴곡강도도 Premisa에서 CIE $a^*$ 및 CIE $b^*$ component와 음의 상관관계를 보였다(Pearson product moment correlation, p < 0.05). 결론: 광중합 복합레진의 중합률과 굴곡강도는 제품의 중합 전,후의 색 성분에 의해 영향을 받았다.

설측 복합레진 색상이 치아 순측 색상에 미치는 영향 (INFLUENCE OF THE COLOR OF COMPOSITE RESINS APPLIED TO LINGUAL SURFACE ON THE LABIAL TOOTH COLOR)

  • 문승희;박수정;조현구;황윤찬;오원만;황인남
    • Restorative Dentistry and Endodontics
    • /
    • 제34권4호
    • /
    • pp.309-323
    • /
    • 2009
  • 본 연구는 순면 잔존 치질의 두께와 후방 복합레진의 색상이 최종 수복된 치아표면의 색상에 미치는 영향을 알아보고자 시행하였다. 배경판으로 사용될 복합레진은 Filtek Supreme (3M ESPE, St. Paul, U.S,A.)의 A1, A2, A6D, B1, B2, B3, C1, C2, C6D를 선택하였다. 배경판으로 사용될 복합레진 시편은 직경 10 mm, 두께 4.5 mm로 각 shade당 한 개씩 제작하였다. 순면 잔존 치질은 상악 중절치 치관의 순면을 제외한 나머지 부위를 아크릴릭 레진을 이용하여 매몰 후 저속의 Diamond Wheel Saw (Isomet ; Buehler Ltd, Lake Bluff, U.S.A.)를 이용하여 주수 하에 순면으로부터 2.5 mm 두께로 절단하였다. 절단된 상아질측 표면을 2000번 사포로 연마하여 2.2 mm 두께의 시편을 얻었다. 분광광도계 $Spectrolino^{(R)}$(Serial No. 3257-18522, GretagMacbeth, Regensdorf, Switzerland)를 이용하여 치아 시편을 9개의 복합레진 시편위에 접촉면에 수분이 있는 상태로 위치시켜 치아 순면색상을 측정하였다. 그 후, 치아시편의 상아질 측면을 1.0 mm까지 0.3 mm 간격으로 연마하면서 복합레진 시편위에 위치시켜 동일한 방법으로 색상을 측정하였다. 모든 시편에서 $L^{\ast}$값과 $b^{\ast}$값은 배경색에 무관하게 치아시편의 두께가 두꺼워질수록 증가하는 양상을 보였으나(p < 0.05), $a^{\ast}$값은 배경색에 무관하게 두께에 따른 유의한 차이를 보이지 않았다.