• Title/Summary/Keyword: Enamel bonding

Search Result 170, Processing Time 0.028 seconds

INTENTIONAL REPLANTATION OF THE CROWN-ROOT FRACTURED MAXILLARY CENTRAL INCISOR WITH RESIN BONDING : CASE REPORT (치관-치근 파절된 치아의 레진접착 후 의도적 재식술을 이용한 치험례)

  • Rhee, Ye-Ri;Park, Jae-Hong;Choi, Sung-Chul;Kim, Kwang-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.2
    • /
    • pp.288-292
    • /
    • 2009
  • A crown-root fracture is defined as a fracture involving enamel, dentin, and cementum. The fractures may be grouped according to pulpal involvement into uncomplicated and complicated. Generally a vertically crown-root fractured tooth must be extracted. However, it should be mentioned that the cases have been reported where bonding of the coronal fragment has led to consolidation of the intraalveolar part of the fracture. Definitive conservative therapy comprises one of four treatment alternatives; fragment removal only, fragment removal with gingivectomy, orthodontic extrusion of apical fragment, and surgical extrusion of apical fragment. The choice is primarily determined by the exact information on the site and the type of fracture, but the cost and the complexity of treatment can also be decisional factors. On the other hand, intentional replantation of the teeth with vertical root facture reconstructed with resin bonding has emerged as a new promising method in recent years. This case presents an intentional replantation of the crown-root fractured maxillary central incisor reconstructed with resin bonding. However, an obvious increase of radiolucency was observed after 4 months and the tooth was re-fractured after 16 months.

  • PDF

ADAPTATION OF COMPOSITE RESIN TO DENTINAL WALL USING DENTIN BONDING AGENTS (수종 상아질 접착제의 상아질과의 접합양상에 관한 주사 전자현미경적 연구)

  • Oh, Won-Mann;Yang, Kyu-Ho;Okuda, Reiichi;Sasazaki, Hiromi;Komatsu, Masashi
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.2
    • /
    • pp.641-654
    • /
    • 1994
  • This study was executed to evaluate adaptability of dentin bonding agents to dentinal wall with measuring contraction gap on interface between cavity wall and composite resin by SEM study. 6 kinds of dentin bonding agents were investigated for this study : Gluma, Super Bond C & B, All bond 2, Scotchbond multipurpose, Scotchbond 2 and Clearfil photo bond. 30 of fresh extracted teeth were randomly selected and divided into 6 groups with each 5. The round shaped cavities with 3mm dia. and 1.5mm depth were prepared on cementoenamel junction of buccal surface of teeth. Dentin bonding agents were applied to cavity wall and then the composite resin was filled in the cavity. Specimens were sectioned longitudinally on buccal surface. Sectioned aspects of specimens were impressioned with rubber base materials and finally precise replica were made of epoxy resin poured in negative impression. Contraction gaps were examined on interface between cavity wall and composite resin under condition of 200 and 2000 magnification of SEM. The results were as follows. 1. There were no gap on interface between enamel and composite resin in all specimens, but gaps were mainly exhibited on apical side of lateral wall of dentin of cavity. 2. In Gluma, 2 cases of 5 specimens exhibited excellent adaptation to the cavity wall, indicating no gaps on interface between cavity wall and composite resin. The other specimens showed gaps with range of $0{\sim}15{\mu}m$ width. 3. In Super Bond C & B, gaps with range of $0{\sim}10{\mu}m$ width were mainly exhibited on apical side of lateral wall of dentin of cavity. 4. In All bond 2, all specimens showed the most exellent adaptation to cavity wall when compared to the other materials, indicating no gap interface between cavity wall and composite resin. 5. In Scotchbond multipurpose, gaps with range of $0{\sim}10{\mu}m$ width were locally located on cavity wall. 6. In Scotchbond 2, all specimens showed great amount of gap with range of $5{\sim}25{\mu}m$, indicating the worst adaptation to cavity wall compared to the other materials. 7. In Clearfil photo bond, 2 case of 5 specimens exhibited exellent adaptation to cavity wall, indicating no gap. the other specimens showed gap with range of $0{\sim}15{\mu}m$ width on inferface between cavity wall and composite resin.

  • PDF

A COMPARATIVE STUDY OF THE SHEAR BOND STRENGTH OF DIFERENT CERAMIC BRACKETS AND ADHESIVES (세라믹 브라켓과 교정용 접착제에 따른 전단 결합 강도의 비교 연구)

  • Lee, Joo-Won;Yoo, Dong-Hwan;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.27 no.2
    • /
    • pp.315-326
    • /
    • 1997
  • The purpose of this study was to evaluate the shear bond strength of three kinds of different ceramic brackets with three different bonding adhesives. 5 specimens for each combination were tested for shear bond strength using Instron and for fracture site using SENL And 3 specimens were cross-sectioned for SEM examination of bonding pattern between bracket, resin and enamel surface. The results were as follows 1. The shear bond strength of chemical curing adhesives were higher than that of light curing adhesives. 2. The shear bond strength of Starfire bracket, chemical-bonded type, was lower than that of Transcend bracket, mechanical-bonded type, and Fascination bracket, combined type. 3. Fracture site of each bracket and tooth surface was examined under a light optical stereoscopic microscope, Transcend groups were mainly at the E/R intderface. Fascination groups were mainly at the COMB interface and Starfire groups were mainly at the R/B interface.

  • PDF

The effect of IDS (immediate dentin sealing) on dentin bond strength under various thermocycling periods

  • Lee, sungbok Richard;Lee, Sang-Min;Park, Su-Jung;Lee, Suk-Won;Lee, Do Yun;Im, Byung-Jin;Ahn, Su-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.3
    • /
    • pp.224-232
    • /
    • 2015
  • PURPOSE. The purpose of this study was to find out the effect of immediate dentin sealing (IDS) on bond strength of ceramic restoration under various thermocycling periods with DBA (dentin bonding agent system). MATERIALS AND METHODS. Fifty freshly extracted human mandibular third molars were divided into 5 groups (1 control and 4 experimental groups) of 10 teeth. We removed enamel layer of sound teeth and embedded them which will proceed to be IDS, using All Bond II. A thermocycling was applied to experimental groups for 1, 2, 7, 14 days respectively and was not applied to control group. IPS Empress II for ceramic was acid-etched with ceramic etchant (9.5% HF) and silane was applied. Each ceramic disc was bonded to specimens with Duo-link, dual curable resin cement by means of light curing for 100 seconds. After the cementation procedures, shear bond strength measurement and SEM analysis of the fractured surface were done. The data were analyzed with a one-way ANOVA and Tukey multiple comparison test (${\alpha}$=.05). RESULTS. There were no statistically significant differences between 4 experimental groups and control group, however the mean value started to decrease in group 7d, and group 14d showed the lowest mean bond strength in all groups. Also, group 7d and 14d showed distinct exposed dentin and collapsed hybrid layer was observed in SEM analysis. CONCLUSION. In the present study, it can be concluded that ceramic restorations like a laminate veneer restoration should be bonded using resin cement within one week after IDS procedure.

Low-shrinking composites. Are they reliable for bonding orthodontic retainers?

  • Uysal, Tancan;Sakin, Caglar;AI-Qunaian, Talal
    • The korean journal of orthodontics
    • /
    • v.41 no.1
    • /
    • pp.51-58
    • /
    • 2011
  • Objective: To evaluate the shear bond strength (SBS), fracture mode, wire pull out (WPO) resistance and microleakage between low-shrinking and conventional composites used as a lingual retainer adhesive. Methods: A total of 120 human mandibular incisor teeth, extracted for periodontal reasons, were collected. Sixty of them were separated into two groups. To determine the SBS, either Transbond-LR (3M-Unitek) or Silorane (3M-Espe) was applied to the lingual surface of the teeth by packing the material into standard cylindrical plastic matrices (Ultradent) to simulate the lingual retainer bonding area. To test WPO resistance, 20 samples were prepared for each composite where the wire was embedded in the composite materialand cured. Then tensile stress was applied until failure of the composite occurred. The remaining 60 teeth were divided into two groups and multi-stranded 0.0215-inch diameter wire was bonded with the same composites. Microleakage was evaluated by the dye penetration method. Statistical analyses were performed by Wilcoxon, Pearson chi-square, and Mann-Whitney-U tests at p < 0.05 level. Results: The SBS and WPO results were not statistically significant between the two groups. Significant differences were found between the groups in terms of fracture mode (p < 0.001). Greater percentages of the fractures showed mix type failure (85%) for Silorane and adhesive (60%) for Transbond-LR. Microleakage values were lower in low-shrinking composite than the control and this difference was found to be statistically significant (p < 0.001). Conclusions: Low-shrinking composite produced sufficient SBS, WPO and microleakage values on the etched enamel surfaces, when used as a lingual retainer composite.

TENSILE STRENGTH OF ORTHODONTIC DIRECT BONING ADHESIVES (교정용 접착제의 인장강도)

  • Kwon, Oh-Won
    • The korean journal of orthodontics
    • /
    • v.12 no.1
    • /
    • pp.15-20
    • /
    • 1982
  • The requirement of ideal orthodontic direct bonding adhesive should include longevity of bond, ability to withstand a variety of forces, resistance to the degrading effects of the oral environment, and ability to be easily removed without affecting the integrity of the enamel. The purpose of this study was to evaluate the adhesive properties of recently developed 3 orthodontic directbonding adhesives by testing the tensile strength. 75 premolars extracted for orthodontic treatment were used. The tensile strength was tested by Tensilon/UTM-1-10000C after 24 hours from bonding. Following results were obtained; The mean tensile strength of each product was higher than the maximum force $(29kg/cm^2)$ exerted on a bracket during orthodontic treatment. The tensile strength of Mono-Lok was statistically higher than Concise and Dyna-Bond, although there was no difference between the tensile strength of Concise and Dyna-Bond statistically. Of the filure, the combination type of failure $(68\%)$, where part of the adhesive remained on the tooth and part on the bracket was the most common type. The second type of failure $(22.7\%)$ occurred at the toothadhesive interface and the last type of failure $(9.3\%)$ occurred at the adhesive-bracket interface.

  • PDF

THE EFFECT OF ETCHING TIME ON THE PATTERN OF ACID ETCHING ON THE ENAMEL OF PRIMARY TEETH (산부식 시간에 따른 유전치 법랑질의 부식 유형에 관한 연구)

  • Choi, Su-Mi;Choi, Young-Chul;Park, Jae-Hong;Choi, Sung-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.3
    • /
    • pp.437-445
    • /
    • 2008
  • The presence of a "prismless" layer on the enamel surface particularly on deciduous teeth has been reported by a number of workers. This structure, which appears to lack the normal prism delineations, could interfere with tag formation and hence, reduce bonding to such surfaces. The purpose of this study was to investigate the relationship of etching times on the effect of acid etching on primary enamel with respect to the quality of etching patterns. Labial surfaces of 32 extracted or exfoliated caries-free primary anterior teeth were used. 35% phosphoric acid gel was used only cervical regions of labial surfaces for each etching time group, 15, 30, 45 and 60 seconds. The surfaces were then washed with water for 20 seconds and dried with air spray for 20 seconds. 1. The Type 3 is 75% when the 15 seconds acid etching time was used. 2. The Type 1 is 38% and Type 2 is 75% when the 30 and 45 seconds acid etching time was used. 3. The Type 1 is 25% and Type 2 is 75% when the 60 seconds acid etching time was used. 4. An etching time of 60 seconds produced a constant and regular etching pattern. 5. There is a significant difference between the groups with respect to the patterns of etch achieved(p<0.05). 6. We confirmed that the acid induced patterns(type 1, 2) became more pronounced when the application time increased(p<0.05). $45{\sim}60$ seconds was the optimal time for etching on the primary enamel.

  • PDF

EFFECT OF LIGHT IRRADIATION MODES ON THE MARGINAL LEAKAGE OF COMPOSITE RESIN RESTORATION (광조사 방식이 복합레진 수복물의 변연누출에 미치는 영향)

  • 박은숙;김기옥;김성교
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.4
    • /
    • pp.263-272
    • /
    • 2001
  • The aim of this study was to investigate the influence of four different light curing modes on the marginal leakage of Class V composite resin restoration. Eighty extracted human premolars were used. Wedge-shaped class Y cavities were prepared on the buccal surface of the tooth with high-speed diamond bur without bevel. The cavities were positioned half of the cavity above and half beyond the cemento-enamel junction. The depth, height, and width of the cavity were 2 mm, 3 mm and 2 mm respectively. The specimens were divided into 4 groups of 20 teeth each. All the specimen cavities were treated with Prime & Bond$^{R}$ NT dental adhesive system (Dentsply DeTrey GmbH, Germany) according to the manufacturer's instructions and cured for 10 seconds except group VI which were cured for 3 seconds. All the cavities were restored with resin composite Spectrum$^{TM}$ TPH A2 (Dentsply DeTrey GmbH, Germany) in a bulk. Resin composites were light-cured under 4 different modes. A regular intensity group (600 mW/${cm}^2$, group I) was irradiated for 30 s, a low intensity group (300 mW/${cm}^2$, group II) for 60 s and a ultra-high intensity group (1930 mW/${cm}^2$, group IV) for 3 s. A pulse-delay group (group III) was irradiated with 400 mW/${cm}^2$ for 2 s followed by 800 mW/${cm}^2$ for 10 s after 5 minutes delay. The Spectrum$^{TM}$ 800 (Dentsply DeTrey GmbH, Germany) light-curing units were used for groups I, II and III and Apollo 95E (DMD, U.S.A.) was used for group IV. The composite resin specimens were finished and polished immediately after light curing except group III which were finished and polished during delaying time. Specimens were stored in a physiologic saline solution at 37$^{\circ}C$ for 24 hours. After thermocycling (500$\times$, 5-55$^{\circ}C$), all teeth were covered with nail varnish up to 0.5 mm from the margins of the restorations, immersed in 37$^{\circ}C$, 2% methylene blue solution for 24 hours, and rinsed with tap water for 24 hours. After embedding in clear resin, the specimens were sectioned with a water-cooled diamond saw (Isomet$^{TM}$, Buehler Co., Lake Bluff, IL, U.S.A.) along the longitudinal axis of the tooth so as to pass the center of the restorations. The cut surfaces were examined under a stereomicroscope (SZ-PT Olympus, Japan) at ${\times}$25 magnification, and the images were captured with a CCD camera (GP-KR222, Panasonic, Japan) and stored in a computer with Studio Grabber program. Dye penetration depth at the restoration/dentin and the restoration/enamel interfaces was measured as a rate of the entire depth of the restoration using a software (Scion image, Scion Corp., U.S.A.) The data were analysed statistically using One-way ANOVA and Tukey's method. The results were as follows : 1. Pulse-Delay group did not show any significant difference in dye penetration rate from other groups at enamel and dentin margins (p>0.05) 2. At dentin margin, ultra-high intensity group showed significantly higher dye penetration rate than both regular intensity group and low intensity group (p<0.05). 3. At enamel margin, there were no statistically significant difference among four groups (p>0.05). 4. Dentin margin showed significantly higher dye penetration rate than enamel margin in all groups (p<0.05).

  • PDF

The effects of salivary contamination on tensile bond strength of resin modified glass ionomer cements in bonding brackets (브라켓 접착시 타액 오염이 레진 강화형 글래스 아이오노머 시멘트의 인장 접착 강도에 미치는 영향)

  • Lee, Kyoung-A;Kwon, Oh-Won
    • The korean journal of orthodontics
    • /
    • v.30 no.1 s.78
    • /
    • pp.83-89
    • /
    • 2000
  • The purposes of this study were to evaluate clinical applicability of resin modified glass ionomer cements and to determine the effect of salivary contamination on the tensile bond strength. Fourty extracted human permanent premolars were prepared lot bonding and standard edgewise brackets were bonded with Ortho-One, Fuji Ortho LC, Vitremer and Advance. Fourty extracted human permanent premolars were contaminated with saliva, dried and bonded with same materials above. The tensile bond strength was tested by Instron testing device aster storage in normal saline at ,$37^{\circ}C$ for 24 hours from bonding. The results were as follows : 1. The tensile bond strength of Ortho-One group was $7.68\pm1.76$, Advance group was $7.87\pm2.80$, Fuji Ortho LC group was $4.99\pm2.53$, Vitremer group was $2.80\pm0.88$ MPa. The tensile bond strength in contaminated condition of Ortho-One group was $4.12\pm1.67$, Advance group was $5.37\pm0.68$, Fuji Ortho LC group was $4.41\pm1.61$, Vitremer group was $2.60\pm1.10$ Mpa. 2. Salivary contamination did not affect the tensile bond strength when compared with the uncontaminated enamel group in Fuji Ortho LC and Vitremer (p>0.05) and there was great significant difference in the tensile bond strength of Ortho-One and Advance. 3. Advance, Ortho-One and Fuji Ortho LC seemed to have clinically a proper bond strength.

  • PDF

Modified laser etching technique of enamel for bracket bonding (브라켓 부착을 위한 변형된 레이저 부식법)

  • Yun, Min-Sung;Lee, Sang-Min;Yang, Byung-Ho
    • The korean journal of orthodontics
    • /
    • v.40 no.2
    • /
    • pp.87-94
    • /
    • 2010
  • Objective: Many studies have carried out research on comparisons between laser etching and conventional etching systems to investigate methods of reinforcing shear bond strength. The purposes of this study were to assess the efficiency of bonding with erbium, chromium doped: yttrium-scandium-gallium-garnet (Er,Cr:YSGG) laser etching combined with the conventional etching technique. Methods: Sixty-four sound premolars, extracted for orthodontic purposes, were randomly divided into 4 groups and treated in the following manner. First group, conventional etching of 37% phosphoric acid for 15 seconds (control); second group, 1.5 W laser etching for 10 seconds followed by conventional etching; third group, conventional etching followed by 1.5 W laser etching; fourth group, 1.5 W laser etching for 15 seconds only. We assessed the shear bond strength, the surface characteristics, and the adhesive remnant index scores between all groups. Results: Experimental groups showed higher shear bond strength than the control group. But no statistically significant differences were found between the second and third groups. Adhesive remnant scores were compared with the Kruskal-Wallis test, and no statistically significant differences were found between all groups. Conclusions: To obtain maximum shear bonding strength, a combined technique of Er,Cr:YSGG and 37% phosphoric acid is useful even though it may be inconvenient.