Vibration Analysis of Transformer DC bias Caused by HVDC based on EMD Reconstruction

  • Liu, Xingmou;Yang, Yongming;Huang, Yichen
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.781-789
    • /
    • 2018
  • This paper proposes a new approach utilizing empirical mode decomposition (EMD) reconstruction to process vibration signals of a transformer under DC bias caused by high voltage direction transmission (HVDC), which is the potential cause of additional vibration and noise from transformer. Firstly, the Calculation Method is presented and a 3D model of transformer is simulated to analyze transformer deformation characteristic and the result indicate the main vibration is produced along axial direction of three core limbs. Vibration test system has been built and test points on the core and shell of transformer have been measured. Then, the signal reconstruction method for transformer vibration based on EMD is proposed. Through the EMD decomposition, the corrupted noise can be selectively reconstructed by the certain frequency IMFs and better vibration signals of transformer have been obtained. After EMD reconstruction, the vibrations are compared between transformer in normal work and with DC bias. When DC bias occurs, odd harmonics, vibration of core and shell, behave as a nonlinear increase and the even harmonics keep unchanged with DC current. Experiment results are provided to collaborate our theoretical analysis and to illustrate the effectiveness of the proposed EMD method.

Study on the pre-processors to improve the generalized-cross-correlation based time delay estimation under the narrow band single tone signal environments (협대역 단일 주파수 신호 환경에서 일반 상호 상관 시간 지연 추정 향상을 위한 전처리기 연구)

  • Lim, Jun Seok;Kim, Seongil
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.3
    • /
    • pp.207-215
    • /
    • 2020
  • There are several methods for the time delay estimation between signals to two receivers. Among these methods, Generalized Cross Correlation (GCC), which estimates the relative delay from the cross-correlation between the different signals at the two receivers, is a traditionally well-known method. However, when using a narrow band Continuous Wave (CW) signal, the GCC method degrades the estimation performance from relatively higher signal-to-noise ratio than when using a wideband signal. To improve this phenomenon, this paper examines four different pre-processors for GCC using narrow band single frequency signals. Simulation shows that the performance gain of the preprocessed GCC is up to 9 dB for a 100 msec CW signal as well as up to 4 dB for a 1 s CW signal.

Damage Detection for Bridge Pier System Using filbert-Huang Transom Technique (Hilbert-Huang변환을 이용한 교각시스템의 손상위치 추정기법)

  • 윤정방;심성한;장신애
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.03a
    • /
    • pp.159-168
    • /
    • 2002
  • A recently developed filbert-Huang transform (HHT) technique is applied to detect damage locations of bridge structures. The HHT may be used to identify the locations of damages which exhibit nonlinear and nonstationary behavior, since the HHT can show the instantaneous frequency characteristics of the signal. A series of numerical simulations were conducted for bridge pier systems with damages under a controlled load with sweeping frequency. The results of the numerical simulation study indicate that the HHT method can reasonably identify damage locations using a limited number of acceleration sensors under severe measurement noise condition.

  • PDF

Event Trigger Generator for Gravitational-Wave Data based on Hilbert-Huang Transform

  • Son, Edwin J.;Chu, Hyoungseok;Kim, Young-Min;Kim, Hwansun;Oh, John J.;Oh, Sang Hoon;Blackburn, Lindy;Hayama, Kazuhiro;Robinet, Florent
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.2
    • /
    • pp.55.4-56
    • /
    • 2015
  • The Hilbert-Huang Transform (HHT) is composed of the Empirical Mode Decomposition (EMD) and the Hilbert Spectral Analysis (HSA). The EMD decomposes any time series data into a small number of components called the Intrinsic Mode Functions (IMFs), compared to the Discrete Fourier Transform which decomposes a data into a large number of harmonic functions. Each IMF has varying amplitude and frequency with respect to time, which can be obtained by HSA. The time resolution of the modes in HHT is the same as that of the given time series, while in the Wavelet Transform, Constant Q Transform and Short-Time Fourier Transform, there is a tradeoff between the resolutions in frequency and time. Based on the time-dependent amplitudes of IMFs, we develop an Event Trigger Generator and demonstrate its efficiency by applying it to gravitational-wave data.

  • PDF

Fault Diagnosis of Transformer Based on Self-powered RFID Sensor Tag and Improved HHT

  • Wang, Tao;He, Yigang;Li, Bing;Shi, Tiancheng
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.2134-2143
    • /
    • 2018
  • This work introduces a fault diagnosis method for transformer based on self-powered radio frequency identification (RFID) sensor tag and improved Hilbert-Huang transform (HHT). Consisted by RFID tag chip, power management circuit, MCU and accelerometer, the developed RFID sensor tag is used to acquire and wirelessly transmit the vibration signal. A customized power management including solar panel, low dropout (LDO) voltage regulator, supercapacitor and corresponding charging circuit is presented to guarantee constant DC power for the sensor tag. An improved band restricted empirical mode decomposition (BREMD) which is optimized by quantum-behaved particle swarm optimization (QPSO) algorithm is proposed to deal with the raw vibration signal. Compared with traditional methods, this improved BREMD method shows great superiority in reducing mode aliasing. Then, a promising fault diagnosis approach on the basis of Hilbert marginal spectrum variations is brought up. The measured results show that the presented power management circuit can generate 2.5V DC voltage for the rest of the sensor tag. The developed sensor tag can achieve a reliable communication distance of 17.8m in the test environment. Furthermore, the measurement results indicate the promising performance of fault diagnosis for transformer.

Design of 3-Dimension Remote Controller Applying the EMD Algorithm which Attenuates the Effect of Noise

  • Yeo, Sang-Rae;Choi, Heon Ho;Ko, Jae Young;Park, Chansik;Lee, Sang Jeong
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.2 no.1
    • /
    • pp.67-74
    • /
    • 2013
  • In this study, a remote controller was designed using localization technique. The designed remote controller system consists of infrared transmit/receive module for time synchronization, ultrasonic transmit/receive module for measuring the TOA value, and micro-controller for processing the measured data value. For the position estimation method of remote controller, the Savarese method was used which does not have a problem of diverging solution depending on initial value. The noise included in the measured value was removed by separating the signal and noise with the use of EMD method which is the non-stationary signal analysis technique. The designed system was tested by constructing a simulation environment, and the improvement of accuracy and precision for the application of EMD method was examined.

Characterization of open and suburban boundary layer wind turbulence in 2008 Hurricane Ike

  • Jung, S.;Masters, F.J.
    • Wind and Structures
    • /
    • v.17 no.2
    • /
    • pp.135-162
    • /
    • 2013
  • The majority of experiments to characterize the turbulence in the surface layer have been performed in flat, open expanses. In order to characterize the turbulence in built-up terrain, two mobile towers were deployed during Hurricane Ike (2008) in close proximity, but downwind of different terrain conditions: suburban and open. Due to the significant non-stationarity of the data primarily caused by changes in wind direction, empirical mode decomposition was employed to de-trend the signal. Analysis of the data showed that the along-wind mean turbulence intensity of the suburban terrain was 37% higher than that of the open terrain. For the mean vertical turbulence intensity, the increase for the suburban terrain was as high as 74%, which may have important implications in structural engineering. The gust factor of the suburban terrain was also 16% higher than that of the open terrain. Compared to non-hurricane spectral models, the obtained spectra showed significantly higher energy in low frequencies especially for the open terrain.

Estimation of slamming coefficients on local members of offshore wind turbine foundation (jacket type) under plunging breaker

  • Jose, Jithin;Choi, Sung-Jin
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.9 no.6
    • /
    • pp.624-640
    • /
    • 2017
  • In this paper, the slamming coefficients on local members of a jacket structure under plunging breaker are studied based on numerical simulations. A 3D numerical model is used to investigate breaking wave forces on the local members of the jacket structure. A wide range of breaking wave conditions is considered in order to get generalized slamming coefficients on the jacket structure. In order to make quantitative comparison between CFD model and experimental data, Empirical Mode Decomposition (EMD) is employed for obtaining net breaking wave forces from the measured response, and the filtered results are compared with the computed results in order to confirm the accuracy of the numerical model. Based on the validated results, the slamming coefficients on the local members (front and back vertical members, front and back inclined members, and side inclined members) are estimated. The distribution of the slamming coefficients on local members is also discussed.

Synchrosqueezed wavelet transform for frequency and damping identification from noisy signals

  • Montejo, Luis A.;Vidot-Vega, Aidcer L.
    • Smart Structures and Systems
    • /
    • v.9 no.5
    • /
    • pp.441-459
    • /
    • 2012
  • Identification of vibration parameters from the analysis of the dynamic response of a structure plays a key role in current health monitoring systems. This study evaluates the capabilities of the recently developed Synchrosqueezed Wavelet Transform (SWT) to extract instant frequencies and damping values from the simulated noise-contaminated response of a structure. Two approaches to estimate the modal damping ratio from the results of the SWT are presented. The results obtained are compared to other signal processing methods based on Continuous Wavelet (CWT) and Hilbert-Huang (HHT) transforms. It was found that the time-frequency representation obtained via SWT is sharped than the obtained using just the CWT and it allows a more robust extraction of the individual modal responses than using the HHT. However, the identification of damping ratios is more stable when the CWT coefficients are employed.

Control Limits of Time Series Data using Hilbert-Huang Transform : Dealing with Nested Periods (힐버트-황 변환을 이용한 시계열 데이터 관리한계 : 중첩주기의 사례)

  • Suh, Jung-Yul;Lee, Sae Jae
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.37 no.4
    • /
    • pp.35-41
    • /
    • 2014
  • Real-life time series characteristic data has significant amount of non-stationary components, especially periodic components in nature. Extracting such components has required many ad-hoc techniques with external parameters set by users in a case-by-case manner. In this study, we used Empirical Mode Decomposition Method from Hilbert-Huang Transform to extract them in a systematic manner with least number of ad-hoc parameters set by users. After the periodic components are removed, the remaining time-series data can be analyzed with traditional methods such as ARIMA model. Then we suggest a different way of setting control chart limits for characteristic data with periodic components in addition to ARIMA components.