• Title/Summary/Keyword: Emission wavelength

Search Result 625, Processing Time 0.024 seconds

AKARI Observation of the North Ecliptic Pole (NEP) Supercluster at z=0.087

  • Ko, Jong-Wan;Im, Myung-Shin;AKARINEP-Wideteam, AKARINEP-Wideteam
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.74.2-74.2
    • /
    • 2010
  • We present a multi-wavelength study of a supercluster in the NEP region at z=0.087, using AKARI (Infrared space telescope) NEP-Wide (5.8 deg2) survey which has obtained an unique IR imaging dataset with contiguous wavelength coverage from 2 to $24{\mu}m$, overcoming the Spitzer limitation of imaging capability at $10-20{\mu}m$. The NEP-Wide survey is also covered in other wavelength such as X-ray, Radio, GALEX UV in the archive, optical (BRI from Maidanak 1.5m and CFHT's MegaPrime), and NIR imaging data (JH from KPNO 2.1m), with nearly 1900 optical spectra, mostly obtained by our group using MMT/Hectospec and WIYN/Hydra. Armed with the multiwavelength datasets, we investigate the connection between IR properties of galaxies and their environments as a tool to understand the evolution of galaxies in a supercluster environment. Specific attention will be given to MIR emission which can trace star formation activities and passive phases right after post-starbursts, and its relation to other wavelength data.

  • PDF

Design and Simulation of Depth-Encoding PET Detector using Wavelength-Shifting (WLS) Fiber Readout

  • An, Su Jung;Kim, Hyun-il;Lee, Chae Young;Song, Han Kyeol;Park, Chan Woo;Chung, Young Hyun
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.4 no.5
    • /
    • pp.305-310
    • /
    • 2015
  • We propose a new concept for a depth of interaction (DOI) positron emission tomography (PET) detector based on dual-ended-scintillator (DES) readout for small animal imaging. The detector consists of lutetium yttrium orthosilicate (LYSO) arrays coupled with orthogonal wavelength-shifting (WLS) fibre placed on the top and bottom of the arrays. On every other line, crystals that are 2 mm shorter are arranged to create grooves. WLS fibre is inserted into these grooves. This paper describes the design and performance evaluation of this PET detector using Monte Carlo simulations. To investigate sensitivity by crystal size, five types of PET detectors were simulated. Because the proposed detector is composed of crystals with three different lengths, degradation in sensitivity across the field of view was also explored by simulation. In addition, the effect of DOI resolution on image quality was demonstrated. The simulation results proved that the devised PET detector with excellent DOI resolution is helpful for reducing the channels of sensors/electronics and minimizing gamma ray attenuation and scattering while maintaining good detector performance.

Optical Properties of InP/InGaP Quantum Structures Grown by a Migration Enhanced Epitaxy with Different Growth Cycles

  • Oh, Jae Won;Cho, Il-Wook;Ryu, Mee-Yi;Song, Jin Dong
    • Applied Science and Convergence Technology
    • /
    • v.24 no.3
    • /
    • pp.67-71
    • /
    • 2015
  • InP/InGaP quantum structures (QSs) were grown on GaAs (001) substrates by a migration-enhanced molecular beam epitaxy method. Temperature-dependent photoluminescence (PL) and emission wavelength-dependent time-resolved PL (TRPL) were performed to investigate the optical properties of InP/InGaP QSs as a function of migration enhanced epitaxy (MEE) growth cycles from 2 to 8. One cycle for the growth of InP QS consists of 2-s In and 2-s P supply with an interruption time of 10 s after each source supply. As the MEE growth cycle increases from 2 to 8, the PL peak is redshifted and exhibited different (larger, comparable, or smaller) bandgap shrinkages with increasing temperature compared to that of bulk InP. The PL decay becomes faster with increasing MEE cycles while the PL decay time increases with increasing emission wavelength. These PL and TRPL results are attributed to the different QS density and size/shape caused by the MEE repetition cycles. Therefore, the size and density of InP QSs can be controlled by changing the MEE growth cycles.

Solution-Processible Blue-Light-Emitting Polymers Based on Alkoxy-Substituted Poly(spirobifluorene)

  • Lee, Jeong-Ik;Chu, Hye-Yong;Oh, Ji-Young;Do, Lee-Mi;Lee, Hyo-Young;Zyung, Tae-Hyoung;Lee, Jae-Min;Shim, Hong-Ku
    • ETRI Journal
    • /
    • v.27 no.2
    • /
    • pp.181-187
    • /
    • 2005
  • Alkoxy-substituted poly(spirobifluorene)s and their copolymers with a triphenylamine derivative have been synthesized by Ni(0)-mediated polymerization. The polymers were well soluble in common organic solvents. Pure blue-light emissions without the long wavelength emission of poly(fluorene)s have been observed in the fluorescence spectra of polymer thin films. The light emitting diodes with a device configuration of ITO/PEDT:PSS(30 nm)/polymer(60 nm)/LiF(1 nm)/Al(100 nm) have been fabricated. The electroluminescence spectra showed the blue emissions without the long wavelength emission as observed in the fluorescence spectra. The relatively poor electroluminescence quantum yield of the homopolymer (0.017% @ 20 $mA/cm^{2}$) with color coordinates of (0.16, 0.07) has been improved by the introduction of triphenylamine moiety, and the copolymer with derivative exhibited an electroluminescence quantum yield of 0.15 % at 20 $mA/cm^{2}$ with color coordinates of (0.16, 0.08). Moreover, the introduction of polar side chains to the spirobifluorene moiety enhanced the device performance and led to the quantum yields of 0.6 to 0.7 % at 20 $mA/cm^{2}$, although there was some expense of color purities.

  • PDF

Application of a LIBS technique using femtosecond and nanosecond pulses for the CIGS films analysis (펨토초 및 나노초 레이저를 이용한 박막태양전지의 레이저 플라즈마 분광 분석)

  • Lee, S.H.;Choi, J.H.;Gonzalez, J.J.;Hou, H.;Zorba, V.;Russo, R.E.;Jeong, S.H.
    • Laser Solutions
    • /
    • v.17 no.4
    • /
    • pp.7-13
    • /
    • 2014
  • In this work, the application of laser induced breakdown spectroscopy (LIBS) for the composition analysis of thin $Cu(In,Ga)Se_2$ (CIGS) solar cell films ($1-2{\mu}m$ thickness) is reported. For the ablation of CIGS films, femtosecond (fs) laser (wavelength = 343nm, pulse width = 500fs) and nanosecond (ns) laser (wavelength = 266nm, pulse width = 5ns) were used under atmospheric environment. The emission spectra were detected with an intensified charge coupled device (ICCD) spectrometer and multichannel CCD spectrometer for fs-LIBS and ns-LIBS, respectively. The calibration curves for fs-LIBS and ns-LIBS intensity ratios of Ga/Cu, In/Cu, and Ga/In were generated with respect to the concentration ratios measured by inductively coupled plasma optical emission spectrometry (ICP-OES).

  • PDF

The study of shape of electrodes and I-V characteristics for Ultraviolet LED

  • Trung, Nguyen Huu;Dang, Vu The;Hieu, Nguyen Van
    • Journal of IKEEE
    • /
    • v.17 no.3
    • /
    • pp.221-228
    • /
    • 2013
  • About functional parameters of a LED/UVLED (Light Emitting Diode/Ultra Violet LED), one of the most important parameters is the I-V characteristic. By researching factors affect to the I-V characteristic of uvled, we found that beside of the structure of the device itself, there is the influence of the electrode materials, electrode shapes, the process of wiring and packaging. In this work, we want to improve the performance of UVLED to find out the optimal mask design principles. The study is based on theoretical mathematical models, as well as the use of simulation software tool Comsol. From all results obtained, the team has improved mask design to manufacture electrodes for GaN-based UVLED. Electrode masks are designed by three softwares, which are Intellisuite, Klayout and AutoCad. Intellisuite masks would be used in fabrication simulation while Klayout and AutoCad are used to fabricate electrodes in experiments. As well as, we silmulated the structure of an uvled 355nm emission wavelength by TCAD software, in order to compare with uvled sample that has the same emission wavelength.

Multiwavelength Millimeter Observations of Dense Cores in the L1641 Cloud

  • Choi, Minho;Kang, Miju;Lee, Jeong-Eun;Kang, Sung-Ju;Kwon, Jungmi;Cho, Jungyeon;Yoo, Hyunju;Park, Geumsook;Lee, Youngung
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.1
    • /
    • pp.55.3-55.3
    • /
    • 2017
  • The L1641 cloud in Orion is an active site of star formation. We mapped a square region of 60 arcmin by 60 arcmin in the continuum emission from 0.89 mm to 2.0 mm wavelength using MUSIC mounted on the Caltech Submillimeter Observatory 10.4 m telescope. Eight sources were detected in at least two wavelength bands, and all the detected emission comes from thermal dust continuum radiation of dense cloud cores. Their spectral energy distributions were characterized. The dust emissivity spectral index is beta = 1.3 on average, within the range of typical cores in nearby star-forming regions. Two cores, V380 Ori NE and HH 34 MMS, have unusually low emissivity index of beta = 0.3. These cores may contain millimeter-sized dust grains, which suggests that the lifetime of some dense cores can be much longer than the free-fall timescale.

  • PDF

Fundamental Study on the Quantitative Analysis of Fluorescent Whitening Agent used for Papermaking (제지용 형광증백제의 정량분석에 대한 기초연구)

  • Lee, Ji-Young;Kim, Chul-Hwan;Lee, Hui-Jin;Gwak, Hye-Joeng
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.43 no.2
    • /
    • pp.9-15
    • /
    • 2011
  • Fluorescent whitening agent (FWA) is a widely used chemical in paper industry, but a systematic and scientific method on FWA analysis has not been established. We performed the basic researches on the fluorescence analysis of FWA. The fluorescence of FWA was investigated using a spectrofluorometer and a spectrophotometer. When FWA solution was analyzed using the spectrofluorometer, we found that the peak wavelength of the fluorescence emission was about 440 nm and that of the fluorescence excitation was about 370 nm irrespective of FWA types. Papers dyed with an internal FWA were prepared in a laboratory and the reflectance and the fluorescence index were measured using the spectrophotometer. It was confirmed that the optimum peak wavelength of the reflectance was 440 nm and the fluorescence index calculated from the CIE whiteness with and without UV light under a light source D65 was the best indicator to measure the fluorescence of FWAs exiting in papers.

Measurement of Fluorescence Signal Strength of NO Particle Using ICCD (ICCD를 이용한 NO입자의 형광신호강도 측정)

  • 전용우;박원주;이광식;이홍식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.4
    • /
    • pp.23-30
    • /
    • 2001
  • In this paper, the discharge image of NO particles wire-cylinder type electrode in the discharge reactor where AC dielectric barrier type corona discharge occurred and horizontal and vertical signal intensity at each flourescence emission during discharge and the horizontal and vertical signal strength of NO particles at flourescence emission wavelength band[236[nm], 247[nm]], were measured were measured by ICCD Camera. In addition discharge images and signal intensities in accordance with discharge time were measured to figure out the discharge mechanism. It was found that the strongest horizontal and vertical signal intensity of NO particles were observed at 247[nm] band, but no big difference in the horizontal and vertical signal intensity in accordance with discharge time was seen. In particular, the phenomenon image occuring inside the discharge reactor and wavelength ware able to be carried based on the measured data.

  • PDF

Optimization of the Coupling and the Reflector Material in the DOI PET Detector Module using the WLS Fiber (파장변이섬유를 사용하는 반응 위치 측정 양전자방출 단층촬영기기 검출기 모듈의 연결물질과 반사체 물질의 최적화)

  • Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.15-20
    • /
    • 2019
  • We developed a novel depth-of-interaction positron emission tomography (PET) detector using wavelength shifting (WLS) fibers and optimized it. The optimization module was designed by using two scintillators and three WLS fibers and attaching a sensor to the end of the WLS fiber. Optimum combinations were obtained through the light collection efficiency and the light collection ratio between sensors depending on coupling materials and reflectors of scintillators, WLS fibers and sensors. The highest light collection efficiency and the light collection ratio between sensors were obtained in the combination of the epoxy (coupling materials)-diffuse reflector (scintillators)-specular reflector (WLS fibers).