• Title/Summary/Keyword: Emission concentration

Search Result 1,874, Processing Time 0.028 seconds

An Analysis of the Range of Brightness Temperature Differences Associated with Ground Based Mass Concentrations for Detecting the Large-scale Transport of Haze (광역적 이동 연무 탐지를 위한 지상 질량 농도를 고려한 적외채널 밝기온도차 경계값 범위 분석)

  • Kim, Hak-Sung;Chung, Yong-Seung;Cho, Jae-Hee
    • Journal of the Korean earth science society
    • /
    • v.37 no.7
    • /
    • pp.434-447
    • /
    • 2016
  • This study analyzed mass concentrations of PM10 and PM2.5, as measured at Tae-ahn and Gang-nae, Cheongju in central Korea over the period from 2011 to 2015. Higher mass concentrations of PM10, with the exception of dustfall cases during the period of winter and spring, reflected the influence of a prevailing westerly airflow, while the level of PM10 stayed at a low level in summer, reflecting the influence of North Pacific air mass and frequent rainfall. Accordingly, cases where a daily PM10 average of $81{\mu}gm^{-3}$ or over (exceeding the status of fine dust particles being 'a little bit bad') were often observed during the period of winter and spring, with more cases occurring in parts of Tae-ahn that are located close to the sources of pollutant emission in eastern China. Dustfall usually originated from dust storms made up of particles $2.5{\mu}m$ or over in diameter. However, anthropogenic haze displayed a high composition ratio of particulate less than $2.5{\mu}m$ in diameter. Accordingly, brightness temperature difference (BTD) values from the Communication, Ocean and Meteorological Satellite (COMS) were $-0.5^{\circ}K$ or over in haze with fine particulate. PM10 mass concentrations and NOAA 19 satellite BTD for haze cases were analyzed. Though PM10 mass concentrations were found to be lower than $200{\mu}g\;m^{-3}$, the mass concentration ratio of PM2.5/PM10 was measured as higher than 0.4 and BTD was found to be distributed in the range from -0.3 to $0.5^{\circ}K$. However, the BTD of dustfall cases exceeding $190{\mu}g\;m^{-3}$, were found to be less than 0.4 and BTD was found to be distributed in the range less than $-0.7^{\circ}K$. The result of applying BTD threshold values of the large-scale transport of haze proved to fall into line with the range over which aerosols of MODIS AOD and OMI AI were distributed.

Development of Three-Dimensional Trajectory Model for Detecting Source Region of the Radioactive Materials Released into the Atmosphere (대기 누출 방사성물질 선원 위치 추적을 위한 3차원 궤적모델 개발)

  • Suh, Kyung-Suk;Park, Kihyun;Min, Byung-Il;Kim, Sora;Yang, Byung-Mo
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.1
    • /
    • pp.31-39
    • /
    • 2016
  • Background: It is necessary to consider the overall countermeasure for analysis of nuclear activities according to the increase of the nuclear facilities like nuclear power and reprocessing plants in the neighboring countries including China, Taiwan, North Korea, Japan and South Korea. South Korea and comprehensive nuclear-test-ban treaty organization (CTBTO) are now operating the monitoring instruments to detect radionuclides released into the air. It is important to estimate the origin of radionuclides measured using the detection technology as well as the monitoring analysis in aspects of investigation and security of the nuclear activities in neighboring countries. Materials and methods: A three-dimensional forward/backward trajectory model has been developed to estimate the origin of radionuclides for a covert nuclear activity. The developed trajectory model was composed of forward and backward modules to track the particle positions using finite difference method. Results and discussion: A three-dimensional trajectory model was validated using the measured data at Chernobyl accident. The calculated results showed a good agreement by using the high concentration measurements and the locations where was near a release point. The three-dimensional trajectory model had some uncertainty according to the release time, release height and time interval of the trajectory at each release points. An atmospheric dispersion model called long-range accident dose assessment system (LADAS), based on the fields of regards (FOR) technique, was applied to reduce the uncertainties of the trajectory model and to improve the detective technology for estimating the radioisotopes emission area. Conclusion: The detective technology developed in this study can evaluate in release area and origin for covert nuclear activities based on measured radioisotopes at monitoring stations, and it might play critical tool to improve the ability of the nuclear safety field.

Effect of Dietary Supplementation of Yellow Loess on Performance, Blood Component Profile and Concentration in Feces in Broiler Chickens (사료 내 황토 첨가 급여가 육계의 생산성, 혈액성상 및 계분 내 암모니아 발생량에 미치는 영향)

  • Park, Sung-Bok;Kang, Hwan-Ku;Bang, Han-Tae;Kim, Min-Ji;Choi, Hee-Chul;Chae, Hyun-Seok;Yu, Dong-Jo;Suh, Ok-Suk;Na, Jae-Cheon
    • Korean Journal of Poultry Science
    • /
    • v.37 no.1
    • /
    • pp.9-13
    • /
    • 2010
  • This experiment was conducted to investigate the effect of dietary supplementation of yellow loess on performance and blood component profile in broiler chickens. A total of three hundred sixty, 1 day old broiler chicks (Ross) were randomly divided into 3 groups with 4 replicates of 30 birds each. The experiment feeds were; control (basal diet), 0~10 days (basal diet with yellow loess T1 4%, T2 2%), 11~21 days (basal diet with yellow loess T1 2%, T2 1%), 22~35 days (basal diet with yellow loess T1 1%, T2 1%). The body weight and weight gain of the broilers fed T2 diet was significant higher than the T1 and control treatment (P<0.05). Feed intake was significantly higher than the control during overall period (P<0.05). Total cholesterol in all yellow loess supplemented treatments were significantly higher than the control treatment (P<0.05), and the triglyceride of broiler fed the diet containing T1 was significantly higher than the control and T2 treatment (P<0.05). No significant differences were observed on the total white blood cell (WBC), neutrophil (NE), monocyte (MO) and eosinophil (EO) in all yellow loess supplemented treatments compared to the control. Lymphocyte of T2 treatment was significantly higher than T1 and control treatment (P<0.05). No significant difference was observed on fecal ammonia gas emission, but broiler fed yellow loess was lower than the control treatment. Aa a result, dietary supplementation of yellow loess was improve to weight gain and feed intake of broiler.

Evaluation of Airborne Pb Sources in an Industrialized City by Applying Pb Isotope Ratios and Concentrations in PM10 (PM10 내 납의 동위원소와 농도를 활용한 산업도시지역 대기 중 납 오염원 평가)

  • Jo, Wan-Kuen;Lee, Heon-Chul;Kim, Mo-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.3
    • /
    • pp.174-182
    • /
    • 2011
  • The present study evaluated the major lead sources in a steel metallurgy industrialized city by measuring lead isotopes/lead concentrations of ambient air and potential sources in an industrial area and residential areas according to relative distance. The quality control program obtained during the measurement procedure for lead isotopes and concentrations exhibited $0.5ng/m^3$ for method detection limit, more than 90% for recoveries of standard particulate matters, and lower than 0.2% for reproducibility errors of four lead isotopes ($^{204}Pb$, $^{206}Pb$, $^{207}Pb$, $^{208}Pb$). For all three lead isotope ratios ($^{206}Pb/^{204}Pb$, $^{207}Pb/^{206}Pb$, $^{208}Pb/^{206}Pb$), the ratios were obtained in the industrial area were closer to nearby residential area than those of a residential area far away from the industrial area, thereby suggesting that lead sources were more similar each other in the industrial and nearby residential area. Furthermore, for both summer and winter seasons ambient lead concentrations were more than four times higher in the industrial area than in the residential areas and in turn, they were higher in the nearby residential area compared with the far-away residential area. As a result, it was suggested that lead emitted from the industrial area would influence more the ambient lead in the nearby residential area than the far-away residential area. Both slag and traffic emissions are likely to be major lead sources in the industrial and nearby residential areas, since their three lead isotope ratios ($^{206}Pb/^{204}Pb$, $^{207}Pb/^{206}Pb$, $^{208}Pb/^{206}Pb$) were similar to the ratios obtained from ambient air of these two areas. In addition, the lead isotope ratios revealed different pattern between seasons, and the ambient lead concentrations were higher for winter than for summer.

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

Effects of Dietary Germanium Biotite on Growth Performance and Blood Characteristics in Broiler Chicks (육계에 있어 게르마늄 흑운모의 첨가가 성장 및 혈액성상에 미치는 영향)

  • 이원백;김인호;홍종욱;권오석;민병준;손경승;정연권
    • Korean Journal of Poultry Science
    • /
    • v.30 no.1
    • /
    • pp.67-72
    • /
    • 2003
  • This study was conducted to investigate the effect of germanium biotite on the growth performance, blood composition , fecal NH$_3$-N and volatile fatty acid(VFA) in broiler chicks. Two hundred forty broiler chicks were randomly allocated into five treatments with four replicates for five weeks. Dietary treatments included 1) Control, 2) GB1(basal diet + 200 mesh 0.5%), 3) GB2(basal diet + 325 mesh 0.5%), 4) GB3(basal diet + 200 mesh 1.0%) and 5) GB4(basal diet +325 nesh 1.0%) For overall period, weight gain, feed intake and feed conversion were not significantly different among treatments (P>0.05). Digestibilities of nutrients were not affected by adding GB(P>0.05). No differences occurred in red blood cell(RBC), white blood cell(WBC), hematocrit(HCT), hemoglobin(Hb), lymphocyte, monocyte and platelet of blood among the treatments (P>0.05). Fecal NH$_3$-N concentration of chicks fed GB1.0 diets(GB3 and GB4) was lower(P<0.03) than chicks fed GB0.5 diets(GB1 and GB2). Propionic acid and butyric acid in feces of chicks fed GB diets were lower(P<0.04) than in chicks fed control diet. GB diets reduced fecal acetic acid significantly compared to control (P<0.01). Also, acetic acid of feces in chicks fed GB1.0 diets(GB3 and GB4) was lower(P<0.02) than GB 0.5 diets(GB1 and GB2) treatments. In conclusion, dietary germanium biotite was an effective means of decreasing fecal NH$_3$-N and volatile fatty acid(VFA) emission.

Effect of Grain Sources on the Ruminal Methane Production in Hanwoo Steers (한우 거세우의 반추위메탄가스 생성량에 대한 곡류사료원의 영향)

  • Seol, Yong-Joo;Kim, Kyoung-Hoon;Baek, Youl-Chang;Lee, Sang-Cheol;Ok, Ji-Woun;Lee, Kang-Yeon;Choi, Chang-Weon;Lee, Sung-Sil;Oh, Young-Kyoon
    • Journal of Animal Science and Technology
    • /
    • v.54 no.1
    • /
    • pp.15-22
    • /
    • 2012
  • This study was conducted to investigate the effects of grain sources on the ruminal methane production in Hanwoo steers. Six Hanwoo steers (BW = 614.4 ${\pm}$ 8.3 kg) were fed, on a DM basis (TDN 6.91 kg), 10% rice straw and 90% barley or corn based concentrate, respectively, according to Korean Feeding Standards (Hanwoo). Each period lasted 18 days including a 14-day adaptation and a 4-day measuring period. The steers were in the ventilated hood-type respiration chamber system (one cattle per chamber) during each measuring period to measure heat and methane production for 1 day. Nutrient intake and digestibility were not affected by steer fed grain sources. Methane concentration was not affected by steer fed either barley or corn-based concentrate, respectively (0.022% vs. 0.025%). Methane production was greater by steers fed corn than those fed barley (119.3 g/day vs. 139.4 g/day). This result indicated that methane emission factor by maintenance energy requirement for the late fattening Hanwoo fed corn was higher than the steers fed barley (43.6 kg/head/year) vs. corn (50.9 kg/head/year). Methane conversion rate (Ym) was 0.04 Ym and 0.05 Ym for barley and corn, respectively.

A Study on the Effective Controlling System of Radio-activity Ventilation (RI사용 의료기관의 효율적인 배기관리 방안)

  • Lee, Kyung-Jae;Lee, Jin-Hyung;Kim, Kyung-Hoon;Kwack, Dong-Woo;Jo, Hyun-Duck;Ko, Kil-Man;Park, Young-Jae;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.91-98
    • /
    • 2008
  • Purpose: Radio-isotopes (RI) use has been steadily developing due to industrial and technical development in the modern medical society. Particularly, popularization of domestic cyclotrons dramatically enable hospitals to produce and use diagnostic radio-isotopes. Generally, only specific facilities such as hospitals, research institutes, nuclear power plants and universities can use radio-isotopes, they are also responsible for ventilation system. The strength of radioactivity in the air is strongly regulated and controlled by korea atomic energy law in Korea Institue of Nuclear Safety (KINS), so that air radioactivity exposure can lead to environmental pollution surrounding places. In this study, we'd like to find out the investigation and the present condition of the controlled ventilation system in domestic hospitals by an emission standard from KINS, and try to reach an agreement about how to use the ventilation system. Result: Definition of filters, features and structures of pre-filters, hepa-filters, charcol filters, filter exchange procedures and precautions are explained. RI deflation concentration and filter exchange cycle have been presented as a standard prescribed in the rules of KINS. The Radiation Control Management System (RCMS) introduced by Seoul National University Bundang Hospital linking to digital pressure gauge with computer controller in another medical facilities were described in details. Conclusions: The system of medical facilities using RI has been remarkably developing in 21 century. Especially, radiation safety control system has also been grown rapidly into the subdivision, specialization, advanced technology along with international technical improvement. However, As far as current RI ventilation system is concerned, it has nothing better than doing in the past. Preferentially, to reinforce this, more sophisticated system with strict periodic filter exchange and exhaust air control guidance should be introduced by applying brilliant domestic information technology for RCMS and digital gauge method. From personal point of view as a radiation safety manager, I have provide with present problems and improvements. Futhermore, more improved guidance should be conducted.

  • PDF

Blood Lead, Manganese, Aluminium and Silicon Concentrations in Korean Adults (한국인의 연, 망간, 알루미늄 및 실리콘의 혈중 농도)

  • Kim, Jung-Man;Ahn, Jung-Mo;Kim, Won-Sul;Kim, Jung-Il;Shin, Hai-Rim;Jung, Kap-Yeol;Kim, Joon-Youn
    • Journal of Preventive Medicine and Public Health
    • /
    • v.33 no.2
    • /
    • pp.157-164
    • /
    • 2000
  • Objectives : This study was peformed to determine the reference values of blood lead, manganese, aluminium, and silicon in healthy adults. Methods : The subjects were 132 (67 male and 65 female), and classified to three age groups $(\leq39,\;40\sim49,\;and\;50\leq)$. Blood lead, manganese and aluminium were analyzed by atomic absorption spectrophotometer, and blood silicon was analyzed by direct current plasma optical emission spectrometer. Results : Blood lead levels(geometric mean, S.D) were (3.49, 1.70) ${\mu}g/dL$ in male and (3.04, 1.65) ${\mu}g/dL$ in female, but the difference is not significant, and there was no significant difference between age groups. Mean blood manganese level was $0.99{\pm}0.41{\mu}g/dL$, and there was no significant difference between sex or age groups. Mean blood aluminium level was $0.59{\pm}0.35{\mu}g/dL$, and there was no significant difference between sex or age groups. Mean blood silicon level was $54.41{\pm}27.64{\mu}g/dL$ in male and $43.34{\pm}23.51{\mu}g/dL$ in female, and the level in male was significantly higher than that in female (p<0.05). There was significant difference between age groups, and the oldest showed the highest level in male (p<0.05), but no significant difference between age groups in female. Conclusions : Authors hope that this study would provide basic data for determining reference values and evaluating health effects.

  • PDF

The Usefulness of F-18 FDG Whole Body PET in the Evaluation of Postoperative Recurrence of Cancer (수술 후 암 재발 판정에 있어서 전신 F-18 FDG-PET의 유용성)

  • Kang, Won-Jun;So, Young;Jeong, Jae-Min;Kwark, Cheol-Eun;Lee, Dong-Soo;Kang, Soon-Bem;Jung, Hee-Won;Kim, Kwang-Hyun;Park, Jae-Gahb;Lee, Myung-Chul;Koh, Chang-Soon;Chung, June-Key
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.3
    • /
    • pp.372-380
    • /
    • 1997
  • The purpose of this study was to evaluate the usefulness of whole body F-18 FDG PET scan for detecting postoperative recurrence of cancer. One hundred four cancer patients after operation were enrolled(14 brain tumor, 15 head and neck cancer, 23 gynecologic cancer, 16 gastrointestinal cancer, 16 thyroid cancer, and 20 other cancers). Besides conventional images(CI) including CT and MRI, F-18 FDG PET scan was obtained on ECAT EXACT 47 scanner(Siemens-CTI), beginning 60 minutes after injection of 370MBq(10mCi) of F-18 FDG. Regional scan was also obtained with emission image. Transmission images using Ge-68 were carried out for attenuation correction in both whole body and regional images. Findings of PET, and CI were confirmed by pathology or clinical follow up. The sensitivity and specificity of PET for detecting recurrence were 94% and 92%, respectively. Contrarily, the sensitivity and specificity of CI were 78% and 68%. CI results were negative and PET results were positive in 11 cases. The biopsy or clinical follow-up of those cases confirmed recurrence of tumor. False negative cases of CI were frequent in patients with gynecologic cancers. Also we measured the serum concentration of tumor markers in patients with gynecologic cancer(CA125), thyroid cancer(thyroglobulin), and colorectal cancer(CEA). The sensitivity and specificity of tumor markers were 71% and 84%, respectively, We conclude that F-18 FDG PET can be used valuably in detecting recurrent foci of a wide variety of malignancy compared to conventional diagnostic methods.

  • PDF