Variation of Liquid to Gas Ratio and Sulfur Oxide Emission Concentrations in Desulfurization Absorber with Coal-fired Thermal Power Plant Outputs (석탄화력 발전설비의 출력에 따른 탈황 흡수탑 액기비와 황산화물 배출농도 변화에 대한 연구)

  • Kim, Kee-Yeong;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.14 no.4
    • /
    • pp.39-47
    • /
    • 2018
  • In this research, when the output of the standard coal-fired thermal power plant operating continuously at the rated output of 500 MW is changed to operate at 300 to 500 MW, the amount of sulfur oxide produced and the amount of sulfur oxide in the absorption tower of desulfurization equipment and proposed an extra liquid to gas ratio improvement inversely proportional to the output. In order to calibrate the combustion efficiency at low power, the ratio of sulfur oxides relative to the amount of combustion gas is increased as the excess air ratio is increased. When the concentration of sulfur oxide at the inlet of the desulfurization absorber was changed from 300 to 500 ppm along with the output fluctuation. The liquid to gas ratio of limestone slurry and combustion gas was changed from 10.99 to 16.27. Therefore, if the concentration of sulfur oxides with output of 300 MW is x, The following correlation equation is recommended for the minimum required flow rate of slurry for the reduction of surplus energy due to the increase of the liquid weight at low load. $y1[m^3/sec]=0.11x+3.74$

  • PDF

A Study on the Environmental Effects of Improvement of Activated Carbon Adsorption Tower for the Application of Activated Carbon Co-Regenerated System in Sihwa/Banwal Industrial Complex (시화반월산업단지 활성탄 공동재생시스템 적용을 위한 활성탄 흡착탑 개선에 따른 환경적 효과분석)

  • Choi, Ye Jin;Rhee, Young Woo;Chung, Gu Hoi;Kim, Duk Hyun;Park, Seung Joon
    • Clean Technology
    • /
    • v.27 no.2
    • /
    • pp.160-167
    • /
    • 2021
  • This study investigated the environmental effects of improving the general-type activated carbon adsorption tower used at the Sihwa/Banwol Industrial Complex with use of a cartridge-type activated carbon adsorption tower for the application of an activated carbon co-regenerated system. Four general-type activated carbon adsorption towers and two cartridge-type activated carbon adsorption towers were selected to analyze the properties of activated carbon and to compare the efficiency of reducing environmental pollutants. The results showed that the activated carbon used in the cartridge-type activated carbon adsorption towers was high quality activated carbon with an iodine adsorption force of more than 800 mg/g and that a good adsorption performance was maintained within the replacement cycle. From an analysis of the environmental pollutant reduction efficiency, it was confirmed that the cartridge-type activated carbon adsorption tower functioned properly as a prevention facility for handling emissions pollutants with a treatment efficiency of total hydrocarbons (THC), toluene, and methylethylketone (MEK) components of 71%, 77%, and 80%, respectively. The general activated carbon adsorption tower, which was confirmed to use low-performance activated carbon, had a very low treatment efficiency and did not function properly as a prevention facility for dealing with emission pollutants. It is believed that it is possible to reduce pollutants during operations by changing from the general-type activated carbon adsorption tower to a cartridge-type activated carbon adsorption tower.

Research Trends in Flotation of Waste-plastics and Its Use as Functional Materials (폐플라스틱의 부유선별 및 기능성 소재로의 활용 연구동향)

  • Han, Yosep;Kim, Rina;Hong, Hye-Jin;Park, In-Su;Kim, Dong-Gyun;Kim, Yun Ho;Jeon, Ho-Seok;Chang, Hankwon
    • Resources Recycling
    • /
    • v.29 no.6
    • /
    • pp.15-26
    • /
    • 2020
  • In recent years, there is an increasing interest in environmental friendly treatment of waste-plastics in terms of the generation of microplastics. Accordingly, the recycling of waste-plastics is very important because it provides advantages of volume reduction, mitigation of carbon dioxide emission, and reproduction of value-added products. In particular, in order to recycle the eco-friendly waste-plastics, it is necessary to use a physical separation methods, and among them, flotation separation, which can separate material (i.e., polymer component) in waste-plastics is well known as a very effective separation method in terms of material recycle. Therefore, in this review, the research trend of flotation separation for effective separation of mixture waste-plastics was investigated. In addition, through the reported research results, approaches to use as new functional materials from polymers, which are raw materials for waste-plastics, are summarized.

Evaluation of the Odor around an Industrial Complex Area and the Operational Effects of the Odor Monitoring System in Seo-gu, Daegu City (대구시 서구 산업단지 주변 지역의 악취오염도와 악취감시시스템 운영 평가)

  • Lee, Myeong-Sug;Keum, Jong-Lok;Kang, Dong-Hoon;Jo, Hang-Wook;Kwon, Byoung-Youne;Kim, Eun-Deok;Lee, Chan-Hyung;Song, Hee-Bong;Shin, Sang-Hee
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.1
    • /
    • pp.45-54
    • /
    • 2021
  • Objectives: This study evaluated the odor around an industrial complex area (#1-#5) and the operational effects of the Odor Monitoring System in Seo-gu in Daegu City. Methods: Samples were collected from November 2012 to December 2018 and were analyzed for complex odor. The odor occurrence rate and the odor reduction rate were calculated. Results: In 2018, the mean concentration of complex odor decreased 20.9% and the odor occurrence rate decreased from 65.0 to 27.5% around the industrial complex area (#1-#5) in Seo-gu compared to 2013. After the operation of the Odor Monitoring System, the standard excess rate (3.0%→40.8%) and the excess concentration of complex odor (1,442→4,304) increased at odor-emitting workplaces. In addition, the mean concentration of complex odor (15.9%) and the odor occurrence rate (60.6%→32.9%) around the industrial complex area (#1-#5) and the number of odor complaints (23.4%) in Seo-gu decreased. Conclusion: In order to reduce the odor around the industrial complex area, it is important to improve the odor emitting facilities. The Odor Monitoring System uses scientific and systematic monitoring methods that can help control and manage the odor emission facilities.

A Study on the Characteristics of Ion, Carbon, and Elemental Components in PM2.5 at Industrial Complexes in Ansan and Siheung (안산·시흥 산업단지 지역 PM2.5 중 이온, 탄소, 원소성분의 특성 연구)

  • Lee, Hye-Won;Lee, Seung-Hyeon;Jeon, Jeong-In;Lee, Jeong-Il;Lee, Cheol-Min
    • Journal of Environmental Health Sciences
    • /
    • v.48 no.2
    • /
    • pp.66-74
    • /
    • 2022
  • Background: The health effects of particulate matter (PM2.5) bonded with various harmful chemicals differ based on their composition, so investigating and managing their concentrations and composition is vital for long-term management. As industrial complexes emit considerable quantities of pollutants, higher PM2.5 concentrations and chemical component effects are expected than in other places. Objectives: We investigated the concentration distribution ratios of PM2.5 chemical components to provide basic data to inform future major emissions control and PM2.5 reduction measures in industrial complexes. Methods: We monitored five sites near the Ansan and Siheung industrial complexes from August 2020 to July 2021. Samples were collected and analyzed twice per week in spring/winter and once per week in summer/autumn according to the National Institute of Environmental Research in the Ministry of Environments' Air Pollution Monitoring Network Installation and Operation Guidelines. We investigated and compared composition ratios of 29 ions, carbon, and elemental components in PM2.5. Results: The analysis of PM2.5 components at the five sites revealed that ion components accounted for the greatest total mass at approximately 50% while carbon components and elemental components contributed 23~28% and 8~10%, respectively. Among the ionic components, NO3- occupies the greatest proportion. OC occupies the greatest proportion of the carbon components and sulphur occupies the greatest proportion of elemental components. Conclusions: This study investigated the concentration distribution ratios of PM2.5 chemical components in industrial complexes. We believe these results provide basic chemical component concentration ratio data for establishing future air management policies and plans for the Ansan and Siheung industrial complexes.

Challenges of Medical Waste Treatment in Fiji (피지국에서의 의료폐기물 처리현황과 문제점)

  • Kim, Daeseon;Bolaqace, Josefa;Rafai, Eric;Lee, Chulwoo
    • Journal of Appropriate Technology
    • /
    • v.6 no.1
    • /
    • pp.37-44
    • /
    • 2020
  • Medical waste is any kind of waste that contains infectious material and recommended not to be transferred for infection control. As a means of disposal, incineration has better points than dumping or landfill in the quantity reduction, odorless and nonhazardous. However, open burning and incineration of health care wastes under bad circumstances, can result in the emission of environmental pollutants to air. A burial of biological waste brings pollution of soil and water. Most of sub divisional hospitals in Fiji transfer their medical wastes to divisional hospitals for incineration. In 2011, 62,518 kg of medical waste was incinerated in the three divisional hospitals. However, some medical wastes are considered as general waste and burnt or sent to landfill site, some are buried on site in some sub-divisional hospitals. In this regards, urgent education is necessary for awareness promotion to relevant personnel in medical waste treatment. On site incineration using small scale incinerator is more recommended than transportation of medical wastes treatment in Fiji. Moreover, remotely controllable and fixable small scale of incinerator is more desirable in sub-divisional hospitals. It is recommended that Fiji government to set up a legal framework for medical waste management (MWM), to develop specific guidelines for MWM, to set up a training system for MWM to ensure that all relevant personnel are trained, to develop a monitoring and supervision system for MWM, to clarify the future financing of MWM activities, and to improve the MWM infrastructure.

Numerical Study on Ignition Delay Time of CH4 as CO/H2 Addition in MILD Combustion (MILD 연소 환경에서 CO/H2 첨가에 따른 CH4의 점화 지연 시간의 해석적 연구)

  • Kim, Donghee;Huh, Kang Y.;Lee, Youngjae
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.2
    • /
    • pp.1-12
    • /
    • 2021
  • MILD(Moderate or Intense Low-oxygen Dilution) combustion has attracted attention as the clean thermal energy technology due to the lower emissions of unburnt carbon and NOx. MILD combustion aims to enlarge the combustion reaction zone using the spontaneous ignition phenomenon of the reactants. In this study, the ignition delay time of CH4 according to the initial temperature of reactants and the addition of CO, H2 was investigated using a numerical approach. Ignition delay time became shorter as the increases of initial temperature and H2 addition. But, CO addition to the fuel increase the ignition delay time. In case of H2 addition to the fuel, the ignition delay time decreased because the higher fraction of HO2 promotes the decomposition of methyl radical(CH3) and produce OH radical. However, in case of CO addition to the fuel, ignition delay time inceased because a high proportion of HCO consumes H radical. There was no significant effect of HCO on the reduction of ignition delay time. Also, the increase rates of NO emissions by the addition of CO and H2 were approximately 7% and 1%, respectively. A high proportion of NCO affects the increase in NO production rate.

Reduction of ammonia conversion from urea by adding acetohydroxamic acid (Acetohydroxamic acid 이용한 Urea로부터 암모니아 발생 저감 연구)

  • Yun, Gwang Su;Oh, Ha Eun;Jung, Min Woong;Hwang, Okhwa;Yun, Yeo-Myeong
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.29 no.4
    • /
    • pp.5-13
    • /
    • 2021
  • Ammonia, primarily originating from urinary urea of the livestock manure, is known to play as a major precursor of fine particulate matter (PM2.5) generation which leads to a decrease in air quality and to harmful effects on public health. The objective of this study was to evaluate the effect of acetohydroxamic acid (AHA) addition on inhibition of ammonia conversion from urea. The experiment was performed at different urea concentration (500-4,000 mg Urea-N/L), AHA concentration (0-4,000 mg AHA/L), pHs (pH 6-10), and temperature (10-35℃). The result showed that the urease inhibition efficiency increased at higher concentration of AHA. However, the specific urease inhibition activity decreased at higher pH, showing 867.1±6.7 Unit/g AHA at pH 6 and 1,167.9±17.4 Unit/g AHA at pH 10, respectively. Decreased urease inhibition efficiency at both AHA and control was observed at higher temperature. This finding indicates that AHA can be used as the urease inhibitor for reducing ammonia emission in the management of livestock manure.

Active VM Consolidation for Cloud Data Centers under Energy Saving Approach

  • Saxena, Shailesh;Khan, Mohammad Zubair;Singh, Ravendra;Noorwali, Abdulfattah
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.11
    • /
    • pp.345-353
    • /
    • 2021
  • Cloud computing represent a new era of computing that's forms through the combination of service-oriented architecture (SOA), Internet and grid computing with virtualization technology. Virtualization is a concept through which every cloud is enable to provide on-demand services to the users. Most IT service provider adopt cloud based services for their users to meet the high demand of computation, as it is most flexible, reliable and scalable technology. Energy based performance tradeoff become the main challenge in cloud computing, as its acceptance and popularity increases day by day. Cloud data centers required a huge amount of power supply to the virtualization of servers for maintain on- demand high computing. High power demand increase the energy cost of service providers as well as it also harm the environment through the emission of CO2. An optimization of cloud computing based on energy-performance tradeoff is required to obtain the balance between energy saving and QoS (quality of services) policies of cloud. A study about power usage of resources in cloud data centers based on workload assign to them, says that an idle server consume near about 50% of its peak utilization power [1]. Therefore, more number of underutilized servers in any cloud data center is responsible to reduce the energy performance tradeoff. To handle this issue, a lots of research proposed as energy efficient algorithms for minimize the consumption of energy and also maintain the SLA (service level agreement) at a satisfactory level. VM (virtual machine) consolidation is one such technique that ensured about the balance of energy based SLA. In the scope of this paper, we explore reinforcement with fuzzy logic (RFL) for VM consolidation to achieve energy based SLA. In this proposed RFL based active VM consolidation, the primary objective is to manage physical server (PS) nodes in order to avoid over-utilized and under-utilized, and to optimize the placement of VMs. A dynamic threshold (based on RFL) is proposed for over-utilized PS detection. For over-utilized PS, a VM selection policy based on fuzzy logic is proposed, which selects VM for migration to maintain the balance of SLA. Additionally, it incorporate VM placement policy through categorization of non-overutilized servers as- balanced, under-utilized and critical. CloudSim toolkit is used to simulate the proposed work on real-world work load traces of CoMon Project define by PlanetLab. Simulation results shows that the proposed policies is most energy efficient compared to others in terms of reduction in both electricity usage and SLA violation.

Health Risk Assessment by Exposure to Heavy Metals in PM2.5 in Ulsan Industrial Complex Area (울산 산단지역 PM2.5 중 중금속 노출에 의한 건강위해성평가)

  • Ji-Yun Jung;Hye-Won Lee;Si-Hyun Park;Jeong-Il Lee;Dan-Ki Yoon;Cheol-Min Lee
    • Journal of Environmental Health Sciences
    • /
    • v.49 no.2
    • /
    • pp.108-117
    • /
    • 2023
  • Background: When particles are absorbed into the human body, they penetrate deep into the lungs and interact with the tissues of the body. Heavy metals in PM2.5 can cause various diseases. The main source of PM2.5 emissions in South Korea's atmosphere has been surveyed to be places of business. Objectives: The concentration of heavy metals in PM2.5 near the Ulsan Industrial Complex was measured and a health risk assessment was performed for residents near the industrial complex for exposure to heavy metals in PM2.5. Methods: Concentrations of heavy metals in PM2.5 were measured at four measurement sites (Ulsan, Mipo, Onsan, Maegok) near the industrial complexes. Heavy metals were analyzed according to the Air Pollution Monitoring Network Installation and Operation Guidelines presented by the National Institute of Environmental Research. Among them, only five substances (Mn, Ni, As, Cd, Cr6+) were targeted. The risk assessment was conducted on inhalation exposure for five age groups, and the excess cancer risk and hazard quotient were calculated. Results: In the risk assessment of exposure to heavy metals in PM2.5, As, Cd, and Cr6+ exceeded the risk tolerance standard of 10-6 for carcinogenic hazards. The highest hazard levels were observed in Onsan and Mipo industrial complexes. In the case of non-carcinogenic hazards, Mn was identified as exceeding the hazard tolerance of 1, and it showed the highest hazard in the Ulsan Industrial Complex. Conclusions: This study presented a detailed health risk from exposure to heavy metals in PM2.5 by industrial complexes located in Ulsan among five age groups. It is expected to be utilized as the basis for preparing damage control and industrial emission reduction measures against PM2.5 exposure at the Ulsan Industrial Complex.