• Title/Summary/Keyword: Emergency Water

Search Result 440, Processing Time 0.023 seconds

A Study on Education of Life Guard in Jeju-Do (제주도내에서의 수상 인명구조원 교육에 대한 연구)

  • Kang, Soon-Min;Kim, Jae Pil
    • The Korean Journal of Emergency Medical Services
    • /
    • v.5 no.1
    • /
    • pp.73-88
    • /
    • 2001
  • Post these safety tips in any swimming area for all swimmers to read. 1. Always swim with companions. Swim only in area well supervised by lifeguards. 2. Never drink alcohol or use drugs when you're swimming or boating. 3. Always check the water depth. Walk in from shore or ease in from the dock or the edge of the pool. 4. Know the limits of your own swimming abilities. If you're a good swimmer, don't tempt nonswimmers or beginner swimmers to try to keep up with you. 5. Keep any eye on younger swimmers at all times. 6. Learn the proper way to dive in the water safely. Follow guidelines for safe diving. 7. Follow the lifeguards instructions and respect their judgment. Never fake an Emergency. Obey all swimming rules.

  • PDF

A flow-directed minimal path sets method for success path planning and performance analysis

  • Zhanyu He;Jun Yang;Yueming Hong
    • Nuclear Engineering and Technology
    • /
    • v.56 no.5
    • /
    • pp.1603-1618
    • /
    • 2024
  • Emergency operation plans are indispensable elements for effective process safety management especially when unanticipated events occur under extreme situations. In the paper, a synthesis framework is proposed for the integration success path planning and performance analysis. Within the synthesis framework, success path planning is implemented through flow-directed signal tracing, renaming and reconstruction from a complete collection of Minimal Path Sets (MPSs) that are obtained using graph traversal search on GO-FLOW model diagram. The performance of success paths is then evaluated and prioritized according to the task complexity and probability calculation of MPSs for optimum action plans identification. Finally, an Auxiliary Feed Water System of Pressurized Water Reactor (PWR-AFWS) is taken as an example system to demonstrate the flow-directed MPSs search method for success path planning and performance analysis. It is concluded that the synthesis framework is capable of providing procedural guidance for emergency response and safety management with optimal success path planning under extreme situations.

Research on rapid source term estimation in nuclear accident emergency decision for pressurized water reactor based on Bayesian network

  • Wu, Guohua;Tong, Jiejuan;Zhang, Liguo;Yuan, Diping;Xiao, Yiqing
    • Nuclear Engineering and Technology
    • /
    • v.53 no.8
    • /
    • pp.2534-2546
    • /
    • 2021
  • Nuclear emergency preparedness and response is an essential part to ensure the safety of nuclear power plant (NPP). Key support technologies of nuclear emergency decision-making usually consist of accident diagnosis, source term estimation, accident consequence assessment, and protective action recommendation. Source term estimation is almost the most difficult part among them. For example, bad communication, incomplete information, as well as complicated accident scenario make it hard to determine the reactor status and estimate the source term timely in the Fukushima accident. Subsequently, it leads to the hard decision on how to take appropriate emergency response actions. Hence, this paper aims to develop a method for rapid source term estimation to support nuclear emergency decision making in pressurized water reactor NPP. The method aims to make our knowledge on NPP provide better support nuclear emergency. Firstly, this paper studies how to build a Bayesian network model for the NPP based on professional knowledge and engineering knowledge. This paper presents a method transforming the PRA model (event trees and fault trees) into a corresponding Bayesian network model. To solve the problem that some physical phenomena which are modeled as pivotal events in level 2 PRA, cannot find sensors associated directly with their occurrence, a weighted assignment approach based on expert assessment is proposed in this paper. Secondly, the monitoring data of NPP are provided to the Bayesian network model, the real-time status of pivotal events and initiating events can be determined based on the junction tree algorithm. Thirdly, since PRA knowledge can link the accident sequences to the possible release categories, the proposed method is capable to find the most likely release category for the candidate accidents scenarios, namely the source term. The probabilities of possible accident sequences and the source term are calculated. Finally, the prototype software is checked against several sets of accident scenario data which are generated by the simulator of AP1000-NPP, including large loss of coolant accident, loss of main feedwater, main steam line break, and steam generator tube rupture. The results show that the proposed method for rapid source term estimation under nuclear emergency decision making is promising.

Analysis of Flow and Thermal Mixing Responses on Hot Water Discharge by Quencher Devices into an Annular Water pool (원환풀내에서 Quencher Device에 의한 고온수 분출로 일어나는 혼합유동에 관한 연구)

  • Choi, Seong-Seok;Kim, Jong-Bo
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.14 no.1
    • /
    • pp.21-30
    • /
    • 1985
  • One of the problems with the Boiling Water Reactor involves the flow and thermal mixings in the suppression water pool high pressure steam discharge into the pool in case of emergency core relief. Varioos heat sensitive devices and pumps for the reactor core cooling are installed in the middle of the suppression pool. Especially the pumps utilize pool water in order to cool the reactor core in emergency cases. In this case, the water temperature for the reactor cool ins should be below a certain temperature specified by the reactor design. In the present investigation, in other to determine the optimum locations of these pumping devices, numerical solutions have been obtained for the model to determine the f low mixing characteristics. Experimental investigations have also been carried out for the flow mixing and for the thermal mixing in the pool during the discharge. Considering that the discharge steam through the Quenching Device becomes hot water immediately in the water pool, the steam- equivalent hot water has been utilized. Examining these characteristices, it becomes possible to deform me the best locations for RCIC, LPCI , HPCI pumps in the suppression water pool for the emermency reactor core cooling.

  • PDF

Evaluation of Flood Control Capacity for Seongju Dam against Extreme Floods (이상강우에 대비한 성주댐의 홍수조절 능력 분석)

  • 권순국;한건연;서승덕;최혁준
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.6
    • /
    • pp.109-118
    • /
    • 2003
  • As a fundamental research to establish a safety operation plan for irrigation dams, this study presents hydrologic analysis conducted in Sungju Dam watershed based on various rainfall data. Especially those reservoirs without flood control feature are widely exposed to the risk of flooding, a safe and optimized operation program need to be improved against arbitrary flooding. In this study, reservoir routing program was developed and simulated for reservoir runoff estimation using WMS hydrology model. The model simulated the variations of reservoir elevation under the condition of open or closed emergency gate. In case of closed emergency gate, water surface elevation was given as 193.15 m, and this value exceeds the dam crest height by 1.65 m. When the emergency gate is open, the increment of water surface elevation is given as 192.01 m, and this value exceeds dam crest height by 0.57 m. As an alternative plan, dam height increase can be considered for flood control under the PMP (Probable Maximum Precipitation) condition. Since the dam size is relatively small compare to the watershed area, sound protection can be expected from the latter option rather than emergency gate installation.

A Buoyant Combined Solar-Wave Power Generation and Its Application for Emergency Power Supply of Nuclear Power Plant (부유식 태양광-파력 복합발전 개념 및 원자력발전소 비상전원을 위한 응용)

  • Cha, Kyung-Ho;Kim, Jung-Taek
    • New & Renewable Energy
    • /
    • v.7 no.4
    • /
    • pp.37-41
    • /
    • 2011
  • This paper presents a Combined solar-wave Power Generation (CPG) concept that the CPG unit is maintained as buoyant at the level of sea water and it is also supported by a submerged tunnel, with the aim of supplying emergency electric power during the station blackout events of nuclear power plants. The CPG concept has been motivated from the 2011 Fukushima-Daiichi Accidents due to the loss of both offsite AC power and emergency diesel power caused by natural hazards such as earthquake and tsunami. The CPG is conceptualized by applying different types and different sites for emergency power generation, in order to reduce common cause failures of emergency power suppliers due to natural hazards. Thus, the CPG can provide a new mean for supplying emergency electric power during station blackout events of nuclear power plants. For this application, the CPG requirements are described with a typical configuration at the ocean side of a submerged tunnel.

A Lethal Case of Sodium Azide Ingestion (아지드화 나트륨(sodium azide) 음독 후 사망한 1례)

  • Nam, Yeoun-Woo;Kim, Jung-Eon;Cho, Jun-Ho;Chung, Sung-Pil;Lee, Hahn-Shick;Kim, Eui-Chung
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.6 no.1
    • /
    • pp.49-51
    • /
    • 2008
  • Sodium azide (NaN3) is a white to colorless, crystalline powder that is highly water soluble, tasteless, and odorless. It is used mainly as a preservative in aqueous laboratory reagents and biologic fluids and also as an automobile airbag gas generant. Although it has caused deaths for decades, the toxic properties and effects of sodium azide in humans remains unknown. A 31-year-old comatose female was transported to the emergency department with an empty bottle labeled sodium azide. She developed cardiac arrest 15 minutes after arrival and expired in spite of 30 minutes of resuscitative effort. Subsequently, resuscitation team members incidentally suffered from sodium azide's exposure and developed eye discomfort, skin rashes parasthesias, pruritus, sore throat, and headache.

  • PDF

Experimental Research for Identification of Thermal Stratification Phenomena in The Nuclear Powerplant Emergency Core Coolant System(ECCS). (원전 비상 노심냉각계통 배관 열성층화 현상 규명을 위한 실험적 연구)

  • Song, Dho-In;Choi, Young-Don;Park, Min-Su
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.735-740
    • /
    • 2001
  • In the nuclear power plant, emergency core coolant system(ECCS) is furnished at reactor coolant system(RCS) in order to cool down high temperature water in case of emergency. However, in this coolant system, it occurs thermal stratification phenomena in case that there is the mixing of cooling water and high temperature water due to valve leakage in ECCS. This thermal stratification phenomena raises excessive thermal stresses at pipe wall. Therefore, this phenomena causes the accident that reactor coolant flows in reactor containment in the nuclear power plant due to the deformation of pipe and thermal fatigue crack(TFC) at the pipe wall around the place that it exists. Hence, in order to fundamental identification of this phenomena, it requires the experimental research of modeling test in the pipe flow that occurs thermal stratification phenomena. So, this paper models RCS and ECCS pipe arrangement and analyzes the mechanism of thermal stratification phenomena by measuring of temperature in variance with leakage flow rate in ECCS modeled pipe and Reynold number in RCS modeled pipe. Besides, results of this experiment is compared with computational analysis which is done in advance.

  • PDF

A Study on Epidemiological Factors of Burn Patients in Emergency Rooms (응급실 화상환자의 역학적 요인에 대한 고찰: 추이변화와 예후에 미치는 영향을 중심으로)

  • Jung, Sung Tae;Ha, Chul Min;Lee, Hyung Ju;Jung, Young Yun
    • Journal of the Korean Burn Society
    • /
    • v.23 no.2
    • /
    • pp.42-53
    • /
    • 2020
  • Purpose: It is important to consider both clinical factors and epidemiological factors in treating burn patients in emergency rooms. However, many emergency medical staffs happen to miss their chances of treating burns based on these considerations. This study is designed to find a better treatment for burn patients in emergency rooms along this approach. Methods: This study was conducted based on the data of the burn patients visiting the emergency room of a single general hospital from January 2015 to December 2019. The epidemiological and clinical factors were extracted out of the data, then the relationship between the prognosis and these factors were analyzed. Results: Most of burn accidents occurred at home, and were caused by hot water, soup, drinks, oil, etc. Especially, flame burns showed high hospitalization rate, surgical rate and mortality. In addition, their prognosis was poor when the affected area included facial, limb and perineal areas etc., or any inhalation burn co-existed. Also, the hospitalization rate and period increased when the treatment time was delayed or the pre-treatment was taken. There was a strong relationship between prognosis and the period of follow-up when patients were admitted during the period. Conclusion: It is difficult for medical staffs to evaluate prognosis of burns in emergency rooms due to progressive damages. Precise treatment and disposition are essential for patients' good prognosis. Therefore, medical staffs should establish treatment plans by identifying the patient's epidemiological and clinical factors, rather than giving prescriptions based on fragmentary and superficial symptoms.