• Title/Summary/Keyword: Elliptical mirrors

Search Result 7, Processing Time 0.02 seconds

NDIR CO2 Gas Sensor for Improving Indoor Air Quality (실내 공기질 향상을 위한 비분산 적외선 이산화탄소 가스센서)

  • Yi, Seung-Hwan;Park, Jeong-Min;Park, Young-Hwan;Han, Seung-Oh
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.7
    • /
    • pp.628-634
    • /
    • 2005
  • We have simulated and proposed novel optical cavity, which has two elliptical mirrors, for NDIR gas sensor module and have tested it from 0 ppm to 2,000 ppm $CO_2$ concentration. The proposed sensor module shows the maximum peak voltage at 500 ms pulse modulation time, however, it shows a maximum voltage changes at 200 ms pulse duration with 18,000 times amplification gain. From 0 ppm to 2,000 ppm, the voltage difference of sensor module $({\Delta}V)$ shows 360 mV at 200 ms pulse duration and 3 sec turn-off time. The response time of designed sensor module is about 30 seconds.

Accuracy Assessment for Measuring Surface Figures of Large Aspheric Mirrors

  • Kim, Young-Soo;Ahn, Ki-Beom;Park, Kwi-Jong;Moon, Il-Kweon;Yang, Ho-Soon
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.2
    • /
    • pp.178-183
    • /
    • 2009
  • At the time that the Keck-I 10m telescope was constructed in 1993, the era of Very Large Telescopes (VLTs) was opened. Now thirteen VLTs are in operation, and the largest of the monolithic mirrors is 8.4 m in diameter. Such monolithic mirrors are mostly aspheric and require high accuracies on the surface figures, reaching up to the diffraction limit. At present, next generation telescopes, Giant telescopes, are being developed. One is the GMT (Giant Magellan Telescope) whose size is 25.4 m in diameter. The primary mirror consists of seven segments figuring elliptical shapes on the surface. The surrounding six segments are off-axis and the edges are steep, as the fast focal ratio is adopted. It means that testing of the mirrors is a challenging task. In this paper, testing methods for the GMT primary mirror are reviewed, and accuracy of measuring devices is assessed. Results and discussions follow.

Miniature Biochip Fluorescence Detection System with Spatial Separation of Fluorescence from Excitation Light (형광과 여기광을 공간적으로 분리하는 바이오칩용 소형 형광측정시스템)

  • Kim Ho-seong;Choi Jea-ho;Park Ju-han;Lee Kook-nyung;Kim Yong-Kweon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.8
    • /
    • pp.378-383
    • /
    • 2005
  • We report the development of miniature fluorescence detection systems that employ miniature prism, mirrors and low coat CCD camera to detect the fluorescence emitted from 40 fluorescently-labeled protein patterns without scanner. This kind of miniature fluorescence detection system can be used in point of care. We introduce two systems, one uses prism+mirror block and the other uses prism and two mirrors. A large NA microscope eyepiece and low cost CCD camera are used. We fabricated protein chip containing multi-pattern BSA labeled with Cy5, using MEMS technology and modified the surface chemically to clean and to immobilize proteins. The measurements show that the combination of prism and mirrors can homogenize elliptical excitation light over the sample with higher optical efficiency, and increase the separation between excitation and fluorescence light at the CCD to give higher signal intensity and higher signal to noise ratio. The measurements also show that protein concentrations ranging from 10 ng/ml to 1000 ng/ml can be assayed with very small error. We believe that the proposed fluorescence detection system can be refined to build a commercially valuable hand-held or miniature detection device.

Optical Design of Multimedia-Embedded LED Dental Astral Lighting using the Reverse Dual Reflector Method

  • Kwon, Young Hoon;Hwang, Hyo Chang;Jun, Hwa Joon;Kwon, Jin Hyuk
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.4
    • /
    • pp.409-414
    • /
    • 2015
  • Light-emitting diodes (LED) have many advantages for dental astral lighting because of their high color rendering index (CRI), low power consumption, light weight and longer life. A dental astral lamp is specially designed and simulated for securing the extra space for installing a multimedia display that will be helpful for treating young patients. The optical system using the reverse dual reflection method consisted of four illumination modules disposed at the four corners of the dental astral lamp, and each module comprises a high power LED, an elliptical mirror, and a multifacet reflector assembly using eight cylindrical mirrors. It is shown that the required illuminance, illumination pattern, and the illumination uniformity are well satisfied.

Temperature Compensation of NDIR $CO_2$ Gas Sensor implemented with ASIC Chip (ASIC칩내장형비분산 적외선 이산화탄소 가스센서의 온도보상)

  • Park, Jong-Seon;Cho, Hee-Chan;Yi, Seung-Hwan
    • 한국가스학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.123-128
    • /
    • 2006
  • This paper describes NDIR $CO_2$ gas sensor that shows the characteristics of temperature compensation. It consists of novel optical cavity that has two elliptical mirrors and a thermopile detector that includes ASIC chip in the same metal package for the amplification of detector output voltage and temperature sensor. The newly developed sensor modules shows high accuracy (less than +/-40 ppm) throughout the measuring concentration of $CO_2$ gas from 0 ppm to 2,000 ppm. After implementing the calculation methods of gas concentration, which is based upon the experimental results, the sensor module shows high accuracy less than +/- 5 ppm error throughout the measuring temperature range $(15^{\circ}C\;to\; 35^{\circ}C)$ and gas concentrations.

  • PDF

Temperature Compensation of NDIR CO2 Gas Sensor (비분산 적외선 이산화탄소 센서의 온도 보상)

  • Park, Jung-Min;Park, Young-Hwan;Yi, Seung-Hwan;Park, Jeong-Ik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.81-82
    • /
    • 2005
  • 본 논문에서는 두 개의 오목 반사경으로 형성된 광 공동 구조의 비문산 적외선 (NDIR) 가스센서를 제작하였다. 증폭비는 18,000 배, 램프 off 시간은 3초로 일정하게 하고 펄스 modulation 시간을 200ms에서 600ms까지 변화시켰을 때. 300ms에서 가장 효율적인 출력신호를 확보할 수 있었다. 그리고 $5^{\circ}C$에서 $45^{\circ}C$까지 $10^{\circ}C$ 간격으로 온도를 변화시키면서 이산화탄소의 농도를 0ppm에서 2000ppm까지 증가시켰다. 이때, 약 400mV의 전압변화가 있었다. 온도가 상승함에 따라 0ppm에서의 출력전압은 감소하는 양상을 나타내었다. 또한 온도변화 대비 출력특성과의 상관성 해석을 통하여 온도 보상 방법을 고안하였으며, 본 연구에서 제작한 센서모듈의 응답시간은 약 30초였다.

  • PDF

Temperature Compensation of NDIR $CO_{2}$ Gas Sensor Implemented with ASIC Chip (ASIC 칩 내장형 비분산 적외선 이산화탄소 가스센서의 온도보상)

  • Yi, Seung-Hwan;Park, Jong-Seon
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.1 s.34
    • /
    • pp.40-45
    • /
    • 2007
  • This paper describes NDIR $CO_{2}$ gas sensor that shows the characteristics of temperature compensation. It consists of novel optical cavity that has two elliptical mirrors and a thermopile that includes ASIC chip in the same metal package for the amplification of detector output voltage and temperature sensor. The newly developed sensor module shows high accuracy ($less\;than {\pm}40\;ppm$) throughout the measuring concentration of $CO_{2}$ gas from 0 ppm to 2,000 ppm. After implementing the calculation methods of gas concentration, which is based upon the experimental results, the sensor module shows high accuracy less than ${\pm}5\;ppm$ error throughout the measuring temperature range ($15^{\circ}C\;to\;35$^{\circ}C$) and gas concentrations with self-temperature compensation.

  • PDF