• Title/Summary/Keyword: Elimination of EMI

Search Result 7, Processing Time 0.024 seconds

Study on EMI Elimination and PLN Application in ELF Band for Romote Sensing with Electric Potentiometer (전위계차 센서를 이용한 원격센싱을 위한 ELF 대역 EMI 제거 및 PLN 응용 연구)

  • Jang, Jin Soo;Kim, Young Chul
    • Smart Media Journal
    • /
    • v.4 no.1
    • /
    • pp.33-38
    • /
    • 2015
  • In this paper, we propose the methods not only to eliminate ELF(Extremely Low Frequency) EMI(Electro-Magnetic Interference) noice for extending recognition distance, but also to utilize the the PLN for detecting starting instance of a hand gesture using electric potential sensor. First, we measure strength of electric field generated in the smart devices such as TV and phone, and minimize EMI through efficient arrangement of the sensors. Meanwhile, we utilize the 60 Hz PLN to extract the starting point of hand gesture. Thereafter, we eliminate the PLN generated in the smart device and circuit of sensors. And then, we shield the sensors from an electric noise generated from devices. Finally, through analyzing the frequency components according to the gesture of target, we use the low pass filter and the Kalman filter for elimination of remaining electric noise. We analyze and evaluate the proposed ELF-band EMI eliminating method for non-contact remote sensing of the EPS(Electric Potential Sensor). Combined with a detecting technique of gesture starting point, the recognition distance for gestures has been proven to be extended to more than 3m, which is critical for real application.

Study on EMI filter for Eliminating Noise from Pole Transformer for PLC (전력선 통신을 위한 저압변압기에서 발생되는 EMI 노이즈 제거 필터 관한 연구)

  • Kim, Young-Sung;Jeong, Jung-Il;Kim, Jae-Chul;Cho, Sung-Min
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.533-534
    • /
    • 2007
  • This paper investigates impulsive noise from a pole transformer in low voltage distribution system for power line communication. EMI noise from the pole transformer is indicated from the experiment. The noise has certain characteristics because it is caused by partial discharge. The noise level is above -35dBm without a filter. Therefore, the filter which is made of ferrite is used in order to eliminate the noise. the noise filters should be applied to both the phase line and the neutral line. Otherwise, It is likely to have little overall impact on elimination of noises. the performance of filter is verified with various experiments. In conclusion, the equivalent circuit of power line communication including noise source is described as a lumped circuit.

  • PDF

Study on Elimination of EMI in ELF-Band for EPS-Based Smart TV Control (전위계차센서 기반 스마트TV 제어를 위한 극저주파 전자기간섭 제거 연구)

  • Jang, Jin-Soo;Kim, Young-Chul
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.3
    • /
    • pp.401-407
    • /
    • 2015
  • In this paper, we propose the method to eliminate EMI (Electro-Magnetic Interference) in ELF (Extremely Low Frequency) band below 2 KHz for extending the gesture-recognition distance of smart TVs to more than 3m using electric potential sensor. First, we measure the electric field generated from the back panel of a TV and propose the effective arrangement of two sets of differential sensors as well as the shielding method using metal fiber. Also, we eliminate the PLN (Power Line Noise) and other noise generated from the TV and sensors as well as surrounding environments using filters. Using the proposed EMI eliminating methods, we evaluate displacement ratio on measured signals according to distance between sensors and a moving hand. Experiment results show that our proposed method can extend the hand-gesture sensing distance using EPS (Electric Potential Sensor) up to more than 3m, which is enough to satisfy applicability of EPS based remote control to Smart TVs.

Pulse-Width Modulation Strategy for Common Mode Voltage Elimination with Reduced Common Mode Voltage Spikes in Multilevel Inverters with Extension to Over-Modulation Mode

  • Pham, Khoa-Dang;Nguyen, Nho-Van
    • Journal of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.727-743
    • /
    • 2019
  • This paper presents a pulse-width modulation strategy to eliminate the common mode voltage (CMV) with reduced CMV spikes in multilevel inverters since a high CMV magnitude and its fast variations dv/dt result in bearing failure of motors, overvoltage at motor terminals, and electromagnetic interference (EMI). The proposed method only utilizes the zero CMV states in a space vector diagram and it is implemented by a carrier-based pulse-width modulation (CBPWM) method. This method is generalized for odd number levels of inverters including neutral-point-clamped (NPC) and cascaded H-bridge inverters. Then it is extended to the over-modulation mode. The over-modulation mode is implemented by using the two-limit trajectory principle to maintain linear control and to avoid look-up tables. Even though the CMV is eliminated, CMV spikes that can cause EMI and bearing current problems still exist due to the deadtime effect. As a result, the deadtime effect is analyzed. By taking the deadtime effect into consideration, the proposed method is capable of reducing CMV spikes. Simulation and experimental results verify the effectiveness of the proposed strategy.

The Control of Switched Reluctance Motor Using MRAS without Speed and Position Sensors (MRAS 관측기를 이용한 SRM의 속도 및 위치센서없는 제어)

  • Yang, Lee-U;Kim, Jin-Su;Kim, Yeong-Seok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.11
    • /
    • pp.632-639
    • /
    • 1999
  • SRM(Switched Reluctance Motor) drives require the accurate position and speed information of the rotor. These informations are generally provided by a shaft encoder or resolver. High temperature, EMI, and dust may make detection performance deteriorate. Therefore, the elimination of the position and speed sensor is desirable. In this paper, a nonlinear adaptive observer using the MRAS(Model Reference Adaptive System) is proposed. The rotor speed and position are estimated by the adaptation law using the real and estimated currents. The stability of the adaptive observer is proved by Lyapunov stability theory. The proposed methods are implemented with TMS320C31 DSP. Experimental results prove that the observer has a good estimation performance of the rotor speed and position despite of the parameter variations and loads, and the speed control can be accomplished in the wide speed range.

  • PDF

The Position Sensorless Control of SRG using the Instantaneous Flux (순시자속을 이용한 위치센서 없는 SRG의 운전)

  • 김영조;오승보;김영석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.5
    • /
    • pp.472-481
    • /
    • 2002
  • In this paper, the instantaneous flux Is applied to control the position of the SRG (Switched Reluctance Generator) without position sensor. The position information of the rotor is required in the drive of SRG. These data are generally obtained by a shaft encoder or resolver. In some cases, the EMI(Electro Magnetic Interference), vibration, thermal, and humidity environments may cause the difficulties in maintaining the satisfactory performance for the position detection. Therefore, the elimination of the position and speed sensor is needed. In this paper, a new method for the position estimation of the SRG is proposed. The estimation of the flux is calculated by using the measured voltage and current. The rotor position gets from the flux profile. The output voltage is also controlled constantly by PR control algorithm. These methods are verified by computer simulations md experiments using DSP. Experimental results certificate that the proposed method is able to control the SRG stable, and keep the output voltage constant in spite of changing of the load.