• Title/Summary/Keyword: Elf-1 domain

Search Result 2, Processing Time 0.017 seconds

Structural assessment of the tetramerization domain and DNA-binding domain of CP2c

  • Jo, Ku-Sung;Ryu, Ki-Sung;Yu, Hee-Wan;Lee, Seu-Na;Kim, Ji-Hun;Kim, Eun-Hee;Wang, Chae-Yeon;Kim, Chan-Gil;Kim, Chul Geun;Won, Hyung-Sik
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.22 no.4
    • /
    • pp.119-124
    • /
    • 2018
  • Although the transcription factor CP2c has been recently validated as a promising target for development of novel anticancer therapy, its structure has not been solved yet. In the present study, the purified recombinant protein corresponding to the tetramerization domain of CP2c appeared to be well folded, whereas the Elf-1 domain showed a largely unfolded conformation. Particularly, the Elf-1 domain, which contains the putative DNA-binding region, showed a conformational equilibrium between relatively less-ordered and well-ordered conformers. Interestingly, addition of zinc shifted the equilibrium to the relatively more structured conformer, whereas zinc binding decreased the overall stability of the protein, leading to a promoted precipitation. Likewise, a dodecapeptide that has been suggested to bind to the Elf-1 domain also appeared to shift the conformational equilibrium and to destabilize the protein. These results constitute the first structural characterization of the CP2c domains and newly suggest that zinc ion might be involved in the conformational regulation of the protein.

Telemetering System of Extremely Low Frequency Magnetic Field Intensity (극저주파 자계 세기를 원격 측정하는 장치)

  • Yoo, Ho-Sang;Wang, Jong-Uk;Seo, Geun-Mee;Gimm, Yoon-Myoung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.5 s.120
    • /
    • pp.553-562
    • /
    • 2007
  • In this paper, we designed and implemented the system for telemetering ELF(Extremely Low Frequency) magnetic field intensity. The magnetic field measurement system used a 3-axis magnetic field sensor to measure the magnetic field with isotropy and the equalizer to compensate the frequency characteristic in band. By multiplexing three output signals of the magnetic field sensor in time domain, we got the uniform gain and frequency characteristic among three axes. This system was designed that the magnetic field measurement level range was $0.01{\sim}10.0\;uT$ and the measurement frequency band was $40{\sim}180\;Hz$. The control system would access to the magnetic field measurement system with RF and the maximum access distance was 1.0 km. We confirmed that the measurement level error of the fabricated system was within 5 %. The fabricated system was installed to a golf practice range where a high voltage power transmission line was crossed.