• Title/Summary/Keyword: Elevator safety

Search Result 141, Processing Time 0.024 seconds

Design and Implementation of Location Based u-Apartment Service System (고급아파트를 위한 위치인식 기반 u-서비스 시스템의 설계 및 구현)

  • Park, Byoung-Tae;Choi, Yeon-Suk
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.2
    • /
    • pp.99-105
    • /
    • 2010
  • In this paper, the uAPSS(u-APartment Service System) that is based on location-aware technology is designed and implemented for a luxury apartment. On the real luxury apartment the developed system has been employed and tested to provide convenient and secure living for residents. It provides services such as emergency call, intelligent elevator operation, and hands-free door access based on the location of the residents with personal device as called smart tag. It can also be applied to other service areas such as the location-aware u-Service for hospitals, high-rising complex buildings, silver towns, etc.

Risk Assessment of Mechanical Parking Facility during Construction based on AHP Analysis (AHP 분석을 이용한 기계식 주차설비 건설 중 위험성 평가방안 연구)

  • Lee, Jeong Han;Kim, Yong Gon;Lee, Jae Won;Kim, Jong Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.5
    • /
    • pp.33-41
    • /
    • 2022
  • As the number of automobile registrations increases yearly, parking spaces that are located in downtown areas are increasing, and mechanical parking facilities are also increasing. Therefore, there is a high risk of accidents when installing and repairing a mechanical parking facility. In the preceding six years (from 2012 to 2018), the statistics that pertain to accidental disasters indicated that a total of 137 disaster victims were generated by the construction sector, 33 accidents occurred, and 10 people died. However, only the safety management items pertaining to accidents that occur during maintenance work and the use of the installed mechanical parking facilities are being studied; furthermore, there is no ongoing research with respect to the risk management that is conducted at the construction site. In 2017, the Korea Occupational Safety and Health Agency (KOSHA) announced the "Guidelines for Safe Installation and Maintenance of Mechanical Parking Equipment"; however, it is a safety guideline that is limited to the installation of basic protective equipment and to facility installation. There is no model for mechanical parking facilities that is indicated in the "Risk Assessment Model by Construction Industry Type", which is issued by the Safety and Health Corporation and is widely utilized for risk assessment in the construction industry; moreover, elevator installation work CODE N0: 22 is the only major example of a disaster. In this study, "risk assessment through a focus group interview" was performed, and data was derived from the "risk assessment of Article 41 (2) of the Industrial Safety and Health Act", which reflects the characteristics of the construction industry based on AHP analysis. The results of this study can be utilized for the risk assessment that is conducted during the construction stage of mechanical parking facilities.

A study on the Comparison of High-rise building Egress Safety Rule in Countries for improvement of High-rise evacuation safety design criteria (초고층 피난안전설계 기준 개선을 위한 국내외 피난관계법령 비교에 관한 연구)

  • Hwang, EunKyung;Park, SuRoh
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.4
    • /
    • pp.429-438
    • /
    • 2013
  • In this study, compare and analyze for high-rise evacuation safety design criteria improvement about internal high-rise building egress safety rule. To the result, high-rise evacuation safety design criteria improvement data can be summarized as follows. First, should compute the evacuation capacity about the number of persons and when more than 2 exits are requested, over 50% of evacuation capacity must be satisfied even approaching to 1 exit is unable. Second, 2 ways of evacuation can be made smoothly by the stair or exit separation-distance standard regulation. Third, regulate the length limitation of dead-end corridor or passageway and it should give grades in limitation of whether the spring-cooler has been installed. Fourth, must secure the evacuation way and do the evacuee guidance when it's safety area and elevator or stair. Also needs to provide extra safety area to secure horizontal direction Escape Safety except fire escaping floor.

A Study on the Evaluation for Elderly Housing Environment (노인주거환경 평가 틀에 관한 연구)

  • Shin, Hwa-Kyoung;Lee, Joon-Min
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.04a
    • /
    • pp.273-277
    • /
    • 2009
  • This study was conducted to develop standards for evaluating what extant the physical environments of housing which can cope with the needs of the aging society. This study was consisted through literature investigation research mainly, and research target literature limits keyword to elderly housing environment and chose connected domestic various literatures. The scope of evaluation was limited to the indoor spaces and outdoor spaces of housing as it was thought that the elderly spend much more time at indoor, outdoors, considering their physical characteristics. The study are as follows ; First, in outdoor only area from design environment element accessibility, and safety emphasized from equipment element, health of community territory was expose from design environment element that supportiveness is emphasized from equipment element. Second, in living room safety emphasized from design environment element in bedroom and bathroom of indoor individuation space, vestibule, balcony supportiveness, health was expose that is emphasized kitchen and mess. Also, was expose that supportiveness is emphasized from equipment element of all individuation spaces. Third, was expose that design environment element in corridor that is indoor official business space, stair, lobby, elevator and safety from equipment element and supportiveness are emphasized.

  • PDF

A Study on the Evaluation for Elderly Housing Environment - Countent Analysis of Elderly Housing Environment Literature Issued after 2000 - (노인주거환경 평가 틀에 관한 연구 - 2000년 이후의 노인주거환경관련 논문에 대한 내용분석을 중심으로 -)

  • Shin, Hwa-Kyoung;Lee, Joon-Min
    • Journal of the Korean housing association
    • /
    • v.21 no.1
    • /
    • pp.151-159
    • /
    • 2010
  • This study was conducted to develop standards for evaluating what extant the physical environments of housing which can cope with the needs of the aging society. This study was consisted through literature investigation research mainly, and research target literature limits keyword to elderly housing environment and chose connected domestic various literatures. The study are as follows; First, in outdoor only area from design environment element accessibility, and safety emphasized from equipment element, health of community territory was expose from design'environment element that supportiveness is emphasized from equipment element. Second, in living room safety emphasized from design' environment element in bedroom and bathroom of indoor individuation space, vestibule, balcony supportiveness, health was expose that is emphasized kitchen and mess. Also, was expose that supportiveness is emphasized from equipment element of all individuation spaces. Third, was expose that design environment element in corridor that is indoor official business space, stair, lobby, elevator and safety from equipment element and supportiveness are emphasized.

A Needs Assessment for Teachers' School Safety Management Competency Development Program (교원 대상 학교안전관리 역량 강화 프로그램 개발을 위한 교육 요구분석)

  • Hwang, Young Ah;Kang, Hyung Gu
    • Journal of the Korean Society of School Health
    • /
    • v.30 no.1
    • /
    • pp.70-80
    • /
    • 2017
  • Purpose: Recently, various accidents and incidents occurred in our school environment, making it necessary to enhance teachers' competency in school safety management. To this end, this study was conducted to analyze the needs of teachers related to school safety management competency development. Methods: For this purpose, the existing teacher's task analysis related to school safety management was revised and surveys were conducted to measure teachers' present level, expectative level and importance of the items based on the task analysis. To analyze the data, Borich Needs Assessment and The Locus for Focus Model were used. Results: In the t-test between the teachers' present level and expectative level about school safety management, all 39 tasks were related (p<.001). The priorities in developing teachers' competency in school safety management were found to be the 6 tasks listed below: 'To deal with each type of accident,' 'To implement CPR and defibrillator,' 'To use fire extinguishers and fire hydrants,' 'To use descending life lines,' 'To give first aid,' and 'To cope with elevator accidents.' Conclusion: By utilizing the results of the teacher's competency and need assesment as components, teachers' training programs can be made more applicable to the school setting. In addition, more experience-based programs should be considered when designing teachers' training programs in order to apply the priority found from the teacher's need assessment.

A Study on Crane Wire Rope Flaws Signal Processing Using Discrete Wavelet Transform (Wavelet 변환을 이용한 크레인 와이어 로프 결함 신호처리에 관한 연구)

  • Min, Jeong-Tak;Sohn, Dong-Seop;Lee, Jin-Woo;Lee, Kwon-Soon
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2002.11a
    • /
    • pp.155-159
    • /
    • 2002
  • Wire ropes are used in a myriad of various industrial applications such as elevator, mine hoist, construction machinery, lift, and suspension bridge. Especially, wire rope of crane is important component to container transfer. If it happens wire rope failures in operating, it may lead to safety accident, economic power loss by productivity decline, competitive power decline of container terminal and so on. To solve this problem, we developed wire rope fault detecting system as a portable instrument, and this system is consisted of 3 parts that fault detecting part using hall sensor, permanent magnets and analog unit, and digital signal processing part using data acquisition card, monitoring part using wavelet transform, denoising method. In this paper, a wire rope is scanned by this system after makes several broken parts on the surface of wire rope artificially. All detected signal has external noise or disturbance according to circumstances. So, we applied to discrete wavelet transform to extract a signal from noisy data that was used filter. In practical applications of denoising, it is shown that wavelet pursue it with little information loss and smooth signal display. It is verified that the detecting system by denoising has good efficiency for inspecting faults of wire ropes in service. As a result, by developing this system, container terminal could reduce expense because of extension of wire ropes exchange period and could competitive power. Also, this system is possible to apply in several fields like that elevator, lift and so on.

  • PDF

Development of the RAS-RMS Protocol optimized to PSTN environment and Implementation of its differentiated process (PSTN 환경에 최적화된 RAS-RMS 연동 프로토콜 개발 및 차별화된 처리과정 구축)

  • Chang, Sung-Keun;Lee, Jung-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8357-8362
    • /
    • 2015
  • The emergency call device has been installed and operated for the elevator passenger safety, but the call can not be connected or delay to the operator in an emergency. The application of the Internet of Things(IoT) technology is required for the systematic management and reliability of the emergency call device installed in the elevator. To meet these requirements it is necessary to apply the RMS(Remote Management System). Emergency call device periodically reports the operating status information and the emergency call history information of the emergency call device to the RMS in the PSTN(Public Switched Telephone Network) environment, and transmits the call request information in an emergency. RAS(Remote Access Server) plays a role of converting the PSTN signals to TCP / IP. RMS reports a significant outbreak call and abnormal operating conditions to administrators. In this study, we developed optimized protocol to PSTN environment that is required by RMS and implemented its differentiated process. And a RAS-RMS Protocol was added to the Application Layer. Development protocol consisting of simple structure as compared to CoAP, MQTT or HTTP can work properly in low-spec CPU and transmit elevator emergency key information easily.

(Restrictions and translation rules of ANSI-C language for analyzing integrity of C program using SPARK Examiner) (SPARK Examiner를 이용해 ANSI-C프로그램의 안전성을 분석하기 위한 C언어의 제약 조건과 변환 방법)

  • 김진섭;차성덕
    • Journal of KIISE:Software and Applications
    • /
    • v.30 no.5_6
    • /
    • pp.587-597
    • /
    • 2003
  • The C language is widely adopted for safety-critical systems. However, it is known that the C language is an unsuitable choice for safety-critical system since the C language includes several bad language features such as heavy use of pointers. The aim of this work is to define safe subset of the C language and translate the subset into the SPARK Ada so that we can verify the program's safety using SPARK analysis tools. SPARK is a safe subset of Ada and has been successfully applied to high integrity system development. The C program translated into SPARK has the same integrity level as SPARK, and the program correctness can be verified by using Examiner which is a SPARK analysis tool. An elevator controller case study is presented and is used to demonstrate the potential use of our approach to implement a realistic system. We also developed a translator that automatically translates C code into SPARK in accordance with the translation rules.

Development of Rule-based Checking Modules for the Evacuation Regulations of Super-tall Buildings in Open BIM Environments (개방형BIM환경에서의 룰기반 초고층건축물 피난법규 검토모듈 개발)

  • Kim, Inhan;Choi, Jungsik;Cho, Geunha
    • Korean Journal of Computational Design and Engineering
    • /
    • v.18 no.2
    • /
    • pp.83-92
    • /
    • 2013
  • IFC based open BIM has internationally developed as a solution for interoperability problem among different software applications. Despite much interest and effort, the open BIM technologies are rarely introduced to the construction industry and need more technical development for a practical application as well. This research aims to develop automated code checking modules for quality assurance process of BIM data. The research have analyzed domestic regulations focusing on super-tall buildings and developed open BIM-based code checking modules for the evacuation regulations. The modules are able to validate evacuation regulations such as installation of emergency elevator and fire safety zone. The authors expect to improve the process of BIM quality assurance and enhance the quality of BIM data by this research on automated checking system.