• Title/Summary/Keyword: Elevator movement

Search Result 23, Processing Time 0.025 seconds

A Model for Material Handling is an Elevator System

  • Kim, Seung-Nam
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.18 no.2
    • /
    • pp.105-130
    • /
    • 1993
  • This study deals with finding a schedule for the movement of a material handling device (elevator) in a manufacturing plant. Two different algorithm (Traveling Salesman Technique and Greedy Algorithm) are used in the scheduling of the elevators using a simulation technique to determine the proper method of scheduling the elevator movement. Based on the simulation analysis, we have found that the Greedy algorithm serves better than the algorithm based on Traveling Salesman technique for scheduling the movement of a material handling device in the manufacturing plant.

  • PDF

The Study on the Effect of Elevator Movement on the Pressure Difference between Vestibule and Living room in High-rise Buildings (초고층 건축물에서 엘리베이터 구동이 부속실과 화재실 간 차압형성에 미치는 영향연구)

  • Park, Younggi;Hong, Kibea;Ryou, Hong Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.85-91
    • /
    • 2018
  • Recently, there have been a lot of casualties due to fires in high-rise buildings. The toxic gases and smokes generated by fires in high-rise buildings spread rapidly through the elevator shaft and stairwell, due to the stack effect, and can cause critical casualties. To reduce the number of casualties, smoke control systems have been introduced. Smoke control systems play an essential role in preventing the spread of smoke in high-rise buildings and securing the evacuation route. Also, in high-rise buildings, evacuation by an elevator is considered to be indispensable. However, the pressure field in the shaft is strongly disturbed when the elevator is moving and this can affect the performance of the smoke control system. Therefore, in this study, we experimentally and numerically analyzed the effect of elevator movement on the pressure difference between the vestibule and living room by building a model using the sandwich pressurization method based on the performance based design. To consider the leakage areas in high-rise buildings, e.g. the windows, fire door and elevator, the National Fire Safety Codes and area ratio were used. The elevator speed in the model building was varied between 20 m/s and 100 m/s corresponding to a real elevator speed of 7 m/s~17 m/s. As a result, the relationship between the pressure difference and elevator speed was found to be ${\Delta}P=40{\cdot}{\exp}$(-Ves /-104.7)-23.735. This result can be used to take into consideration the effect of elevator movement when designing smoke control systems.

Evacuation System for Boarding an Elevator in Disaster (재난 발생 시 승강기 탑승인원을 위한 피난 유도 시스템)

  • Kim, Hyung-O;Kim, Junwoo;Park, Gooman;Cha, Jaesang
    • Journal of Satellite, Information and Communications
    • /
    • v.10 no.4
    • /
    • pp.28-31
    • /
    • 2015
  • The elevator is extreme important due to the large size of the building and public facilities. In particular, it occurs bottleneck phenomenon in a elevator in case of using a theater. So, in this paper, we suggests technology of removing the traffics of visitors' movement and increase the efficiency of the use of elevator. Configuration of the proposed technique is divided parts of the processing unit, the movement route of the mobile cover to help viewers to create a route to collect sensor and the sensed data to detect state and a waiting elevator. This was the design and verification of technical performance and implementation.

A study on the Development of the Device for Portable Safety Diagnosis and Dynamic Characteristics Analysis of Elevator using Fuzzy Algorithm (Fuzzy 알고리즘을 이용한 엘리베이터 포터블 안전진단 및 동특성 분석장치 개발)

  • 김태형;김훈모
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.123-126
    • /
    • 2000
  • An elevator system which is a essential equipment for a vertical movement of object, as a property of building, have been drove by various expenditure and purpose. Since developing electrical control technology, control systems are highly developed. An elevator equipment is expended to wide, but a data accuracy acquisition technique and safety predict technique for securing system safety is still basic level. So, objective verification for elevator confidence condition is required absolutely accuracy measurement technique. Therefore, this study is accomplished in order to conquer a method of depending on sense of a manager with a simple numeric measurement data, and construct a logical, analytical foresight system for more efficient elevator management system.

  • PDF

The Research for Malfunction and Installation Status of Power Quality Counterplan Equipment of Elevator (엘리베이터의 전원품질용 기기 설치 현황 및 오동작에 관한 조사)

  • Kim, Gi-Hyun;Yi, Geon-Ho;Bae, Suk-Myong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.10
    • /
    • pp.107-113
    • /
    • 2006
  • The number of confine-disease for elevator increases every year and then sudden stop, error of level indication stand; those can bring to uneasiness of elevator passenger and malfunction accidents related life accident are increasing. So we researched power quality counterplan equipment(SPD, Filter, Reactor) at site elevator controller room and malfunctions of elevator movement. We could confirm installation of power quality counterplan equipment recently and unchanging the number of malfunction. This data will be used the analysis for mutual relation between Power Quality(Sag, Interruption, ESD, ect.) and malfunction of elevator movement by testing the elevator equipment with EN12016(2004) and IEC standard level.

A study on the Development of the Portable Device for Safety Diagnosis and Dynamic Characteristics Analysis of Elevator using Fuzzy Algorithm (Fuzzy 알고리즘을 이용한 엘리베이터 안전진단 및 동특성 분석 포터블 장비 개발)

  • 김태형;김훈모
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.199-202
    • /
    • 2001
  • An elevator system, which is essential equipment for vertical movement of an object, as a property of building, has been driven by various expenditures and purposes. Since developing electrical control technology, control system are highly developed. The elevator system has expanded widely, but a data accuracy acquisition technique and safety predict technique for securing system safety is still at a basic level. So, objective verification for elevator confidence condition requires an absolute accuracy measurement technique. Therefore, this study is executed in order to acquire a method of depending on sense of a manager with simple numeric measurement data, and to construct a logical, analytical foresight system for more efficient elevator management system. As an artificial intelligence for diagnosis, the fuzzy inference algorithm is used for foreseeing the system in this thesis, because the fuzzy algorithm is the most useful method for resolving subjective ideas and a vague judgment of humans. The fuzzy inference algorithm is developed for each sensor signal(i.e. vibration, velocity, current).

  • PDF

Measures and Cause Analysis of Electrical Disturbance for Elevator Equipment of the Apartment House (공동주택 승강기 설비의 전기적 장해 원인 분석 및 대책에 관한 연구)

  • Kim, Gi-Hyun;Bae, Suk-Myong;Park, Chee-Hyun;Choi, Myeong-Il
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.88-95
    • /
    • 2007
  • Domestic elevator accidents which are related to human life such as death are occurring steadily. This research measured and analyzed for the quality of power source which has possibility to be associated with fault and malfunction of elevator equipment although it is not direct cause examination. In conclusion, we acquired the result that there is possibility that the quality of power source(Sag, Interruption, Harmonic, Electromagnetism emission waveform, Static electricity etc) has an effect on movement of elevator through examination of three elevator facility models and suggested measures for it. Accordingly, this research result will be used as data to suggest establishment of elevator examination regulations and KS regulations for domestic elevator industry and the least safety of household using elevator.

Accident Prevention for the Elevator and Escalator by the Accident Type Analysis (사고유형 분석에 의한 승강기 및 에스컬레이터 재해예방)

  • Jeong, Ok Nam;Yun, Yu Seong;Kwon, Oh Heon
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.4
    • /
    • pp.15-21
    • /
    • 2016
  • The elevator is an essential part of the transportation means in modern society. It has become the convenient movement means of vertical and horizontal mobilities for vulnerable citizens including the disabled or elderly in skyscrapers and the multi-purposes facilities. After the 1990s, the number of newly installed elevators have increased because of the establishment of large scale public houses which need an increase of means of transportation. Thus, the safety accident in the elevator has been currently in an increasing trend as years passed by because that the elevator is always exposed to the risk of accident. Most of the elevator accidents occur in the escalator and moving walkway. This study investigated the current usage situations of users at multi-purpose shopping spaces, the sub way, and the airport about the escalator including moving walkway. Moreover the accident types were analyzed for the escalator based on 10 years of statistics. And the methods for the accident prevention were proposed on the equipment, management and user side.

Pressure Differentials in the Elevator Lobby Depending on the Reference Pressures of the Pressurizing Dampers (급기가압 댐퍼의 설정 기준압에 따른 부속실 차압 특성 연구)

  • Park, Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.21 no.4
    • /
    • pp.12-17
    • /
    • 2007
  • This paper investigated pressure differentials in the elevator lobby depending on reference pressures of the pressurizing damper using FDS fire modeling. The results showed the temperatures and pressures in the contained fire room with small leak gaps can increase significantly. Setting reference pressure of the pressurizing dampers to 0 Pa can cause reduction of real pressure differentials and air velocity to resist smoke flow. This would cause smoke movement from fire room to elevator lobby which should be safe area for evacuation.

A Study on the Research Trends of Smoke Movement in Fire (화재 시 연기거동 관련 연구 동향에 관한 조사)

  • Kim, Hyung-Jin;Shin, Yi-Chul;Hwang, Eun-Kyung;Hwang, Keum-Suk;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.317-320
    • /
    • 2008
  • Smoke is recognized as the major killer in fire situation. smoke often migrate to building locations remote the fire space, threatening life and elevator shafts frequently become smoke-logged, there by blocking evacuation and inhibiting rescue and fire fighting. It is the aim of this study to investigate and analyze the research trends of smoke movement in Fire.

  • PDF