상용 SCR 촉매상에서 화력발전소 배기가스 중 원소수은의 산화반응연구 (Investigation of Elemental Mercury Oxidation on Commercial SCR Catalysts in Flue Gas of Fossil Fired Power Plant)

  • 이승민;이정빈
    • 한국대기환경학회지
    • /
    • 제26권3호
    • /
    • pp.245-252
    • /
    • 2010
  • For the purpose of evaluating to remove elemental mercury using SCR (Selective Catalytic Reduction) catalysts, the result of the concentration variation of elemental mercury in lab experiment and field measurement was compared. The effect of the elemental mercury oxidation on commercial catalysts was studied in simulated gas. Three species of SCR catalyst, $V_2O_5-TiO_2$ type, were selected. The elemental mercury reduced 30% without HCl gas in SCR operating condition. But the width of reduction increased 60% at 20 ppm HCl gas. According to the result of field measurement, reduction rate of elemental mercury at SCR outlet showed 60%. The total mercury concentration decreased about 20%. The results were similar to the lab test. The results of chemical analysis of test sample showed increase of mercury concentration but surface change was not observed.

원소 유황의 Polarograph 거동에 관한 연구 (Studies on the Polarographic Behavior of Elemental Sulfur)

  • 김준용;장순자
    • 약학회지
    • /
    • 제22권4호
    • /
    • pp.201-206
    • /
    • 1978
  • The analysis of elemental sulfur by polarography has already been reported in the literature. Only a discussion of the more important factors influencing the analysis is here presented. (1) The effects of pH on the reduction of elemental sulfur are pronounced and the use of buffered solutions for the analysis of elemental sulfur is necessary. The authors found that a pH of 4-6 was found to be reproducible polarograms by use of D.C. polarograph. However, in alkali solvents the plateau of elemental sulfur has a pronounced dip if the concentration of sulfur is as much as 30ppm. (2) A.C. polarographic method shows a very high sensitivity in the case of sulfur reduction, so that the very low concentration of sulfur can easily be determined (about 1ppm). (3) The characteristics of sulfur wave can be formulated according to Stackelberg-Hauck-Hans equation. It was found that the curve of the peak potential of elemental sulfur in A.C. polarography versus logarithm of sulfur concentration was obtained to be straight line with the slope of 29.6 millivolts. This result was well agreed with theoretical consideration. (4) It was assumed that this polarographical methods were applicable to micro-analysis of elemental sulfur in crude oil and its petrochemical products, precipitated sulfur, and sulfur ointments with accuracy and rapidity.

  • PDF

Evaluation of elemental concentrations of uranium, thorium and potassium in top soils from Kuwait

  • Bajoga, A.D.;Al-Dabbous, A.N.;Abdullahi, A.S.;Alazemi, N.A.;Bachama, Y.D.;Alaswad, S.O.
    • Nuclear Engineering and Technology
    • /
    • 제51권6호
    • /
    • pp.1638-1649
    • /
    • 2019
  • Top soil samples across the state of Kuwait numering ninety were collected and analysed using gamma-ray spectrometry, to evaluate the elemental concentration of $^{238}U$, $^{232}Th$ and $^{40}K$ and their depletion/enrichment. Results of elemental concentration ranges from 0.48 to 2.61 mg/kg, 0.87-5.23 mg/kg, and 0.24-2.23%, with a mean values of 1.39 mg/kg, 3.47 mg/kg, and 1.18%, for the $^{238}U$, $^{232}Th$ and $^{40}K$, respectively. Further analysis was conducted amongst the five identified soil types, i.e. Aquisalids (S1), Calcigypsids (S2), Petrocalcids (S3), Petrogypsids (S4), and torripsamment (S5). The highest radioactivity concentrations from both uranium and thorium were recorded in the S2 (Calcigypsids) soil, with a value of 1.71 (mg/kg) and 4.45 (mg/kg), respectively. Minimum and maximum values of $^{40}K$ are 1.1(%) and 1.27(%) and is prevalent in Aquisalids (S1) and Petrocalcids (S3) soil types, respectively. Ratios of elemental concentration for $^{232}Th/^{238}U$, $^{40}K/^{238}U$, $^{40}K/^{232}Th$ across the soil types are 2.53, 0.09 and 0.03, with a correlation coefficient of 0.92, 0.34, and 0.38, respectively. A progressively higher $^{232}Th/^{238}U$ ratio is observed moving south-wards, indicating lower $^{238}U$ content in soils from the south relative to the northern part. Overall results indicate Kuwait to be relatively an area with low level of natural radioactivity.

초호열성 고세균 Thermococcus sp. DT1331의 유황 화합물 이화 특성

  • 곽이성;김영배
    • 한국미생물·생명공학회지
    • /
    • 제25권4호
    • /
    • pp.354-358
    • /
    • 1997
  • Some sulfur coompounds dissimilation characteristcs of Thermococcus sp. DT1331 were studied. DT1331 had ether-like lipid compounds in addition to esters in the cell membrane. The specific growth rates of DT1331 decreased with increasing head spaces of the cultures. However, when the ratio of head space volume to medium volume was 5.60, the strain showed no growth. DT1331 showed vigo- rous growth with 1% or more elemental sulfur addition. Cystine could substitute elemental sulfur and DT1331 showed moderate growth with 0.1% or more cystine concentration. The specific growth rate and maximum cell concentration of Thermococcus sp. DT1331 in the presence of elemental sulfur were 0.80 hr$^{-1}$ and 2.0 x 10$^{8}$ cells/ml, respectively, while they were 0.67 hr$^{-1}$ and 1.1 x 10$^{8}$ cells/ml, respectively in the presence of cystine.

  • PDF

도저용 착시 도재-금속 개면에서의 원소이동에 관한 실험적 연구 (AN EXPERIMENTAL STUDY OF INTERFACIAL ELEMENTAL TRANSITION IN CERAMO-METAL RESTORATION)

  • 이근우;이호용
    • 대한치과보철학회지
    • /
    • 제25권1호
    • /
    • pp.95-118
    • /
    • 1987
  • This study was undertaken to observe the elemental transition of Interface depending on different pretreatment methods, the number of filings, the kinds of porcelain powders and the various alloys in ceramo-metal restoration. The materials used in this study were Pors-on $4^{(R)}$ and Ceramco porcelain powder to compare the differences depending on the pretreatement methods and the number of firings. Ceramco porcelain powder and Vita porcelain powder were used to compare the differences of elemental transition depending on the porcelain powders. The $Parasil^{(R)},\;PGV^{(R)}$ and Pors-on $4^{(R)}$ as Pd-Ag alloy were used to compare the difference of elemental transition depending on the various alloys. The pretreatment methods were : no treatment, treatment under vacuum and air, treatment with 50 % hydrofluoric acid and double heat tretament. The number of firings were 3, 5 and 7 repeated firings All specimens were observed by SEM and concentration of elements were analyzed quantitatively with EPMA The results of this study were obtained as follows : 1. In the groups of air-treatment, concentration of Sn were the highest and widest. A high concentration of In were in the groups of vacuum and air treatment. 2. There were no significant differences in concentration of Sn between the group of vacuum, 5 minutes hydrofluoric acid and double heat treatment. (p>0.05) 3. As the period of time of hydrofluoric acid treatment increased, not only were the trace elements reduced but the main components such as Pd and Ag were also reduced. 4. Concentration of Sn and In increased and diffused with repeated firings but 5 repeated and 7 repeated firings groups had no significant differences. (p>0.05) 5. Sn were more concentrated in the group of Ceramco porcelaion powder than Vita porcelain powder. 6. The higher concentration of trace elements in the alloy, the more increasing concentration of Sn and In in the interface.

  • PDF

유전체 장벽 방전을 이용한 원소수은의 산화특성 (Oxidation of Elemental Mercury using Dielectric Barrier Discharge Process)

  • 변영철;고경보;조무현;남궁원;신동남;고동준;김경태
    • Korean Chemical Engineering Research
    • /
    • 제45권2호
    • /
    • pp.183-189
    • /
    • 2007
  • 대표적인 수은 발생원인 도시폐기물 소각로와 화력 발전소 등지에서 배출되는 원소수은($Hg^0$)은 산화수은($Hg^{2+}$) 및 입자상 수은($Hg^p$)과 달리 기존의 대기오염 방지시설로 제거하기 난해한 편이다. 그로 인해 원소수은의 효율적 제거에 대한 많은 연구가 진행중이며, 이 연구에서는 저온 플라즈마(non-thermal plasma)의 하나인 유전체 장벽 방전(dielectric barrier discharge: DBD) 공정을 이용하여 원소수은 산화에 관한 실험을 수행하였다. 실험 결과, 공기 상의 DBD 공정에서는 생성되는 산소 원자와 오존에 의해서 원소수은이 산화수은으로 전환됨을 알 수 있었으며, 원소수은의 산화율을 결정하는 주된 변수는 반응기에 주입되는 에너지 밀도임을 확인할 수 있었다.

황을 이용한 강변여과수의 독립영양탈질 (Autrophic Denitrification of Bank Filtrate Using Elemental Sulfur)

  • 문희선;남경필;김재영
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2000년도 추계학술대회
    • /
    • pp.209-212
    • /
    • 2000
  • As a bench-scale study, transformation of nitrate to nitrogen gas under anoxic condition was determined by using autotrophic denitrifiers containing Thiobacillus denitrificans and elemental sulfur as an electron donor. The research objective is to measure the basic kinetic parameters of autotrophic denitrification reaction on the removal efficiency of nitrate. The results showed that nitrate was almost completely transformed to nitrite in the first 4 days of column operation. After 2 days of accumulation of nitrite, its concentration slowly decreased and the compound was detected less than 0.5 mg/L in 14 days. In the experiment, sulfate concentration in the effluent was the 70~90 mg-S/L and the pH was maintained around pH 7.5. When nitrate concentration of bank filtrate in the real field is considered, this sulfate concentration seems to be acceptable. At 17 cm from the bottom of the column, the effluent showed the highest nitrite concentration, and nitrate concentration decreased rapidly to the Point of 33 cm from the bottom. The results suggest that an appropriate thickness of permeable reactive barriers is about 30 cm.

  • PDF

서울지역 일부 대기중 부유먼지에 함유된 탄소 성분과 Benzo(a)pyrene 성분의 농도변동 양상에 관한 연구 (A Study on the Variation of the Concentrations of Carbon Species and B(a)P Associated in Atmospheric Suspended Particles in an Urban Area of Seoul)

  • 황경철;김희강
    • 한국환경보건학회지
    • /
    • 제23권4호
    • /
    • pp.91-96
    • /
    • 1997
  • In order to investigate the behavior of particulate carbon and benzo(a)pyrene(B(a)P) in the ambient air, suspended particle matters were collected from April, 1990 to February, 1992, and total carbon(TC), organic carbon(OC), elemental carbon(EC) and B(a)P were measured by an elemental analyzer and a HPLC. The results were as follows the average concentration of TC was 38.6 $\mug/m^3$ and its concentration was higher in winter(45.4 $\mug/m^3$) and fa11(44.3 $\mug/m^3$) than in summer(36.8 $\mug/m^3$) and spring(28.9 $\mug/m^3$). The monthly concentration trends both of EC and OC was similar, but seasonal variation of EC concentrations was larger than that of OC. The average concentration of B (a)P was 2.2 ng/m$^3$, and was higher in winter(4.1 ng/m$^3$) and fall(3.2 ng/m$^3$) than in spring(1.2 ng/m$^3$) and summer(0.6 ng/m$^3$). The seasonal behavior of carbon and B(a)P was to similar except for summer. The correlation coefficient(r) between EC and B(a)P was 0.71, and the correlation coefficient(r) between OC and B(a)P was 0.66.

  • PDF

Characterization of Sulfur Oxidation by an Autotrophic Sulfur Oxidizer, Thiobacillus sp. ASWW-2

  • Lee Eun Yaung;Cho Kyung-Suk;Ryu Hee Wook
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제5권1호
    • /
    • pp.48-52
    • /
    • 2000
  • An autotrophic sulfur oxidizer, Thiobacillus sp. ASWW-2, was isolated from activated sludge, and its sulfur oxidation activity was characterized. Thiobacillus sp. ASWW-2 could oxidize elemental sulfur on the broad range from pH 2 to 8. When 5-50 g/L of elemental sulfur was supplemented as a substrate, the growth and sulfur oxidation activity of Thiobacillus sp. ASWW-2 was not inhibited. The specific sulfur oxidation rate of strain ASWW-2 decreased gradually until sulfate was accumulated in medium up to 10 g/L. In the range of sulfate concentration from 10 g/L to 50 g/L, the sulfur oxidation rate could keep over $2.0g-S/g-DCW{\cdot}d$. It indicated that Thiobacillus sp. ASWW-2 has tolerance to high concentration of sulfate.

  • PDF

ICP/AES에 의한 먹는물의 무기원소 분석 (Elemental Analysis of Drinking Water with ICP/AES)

  • 박계헌;신형선;한정희
    • 자원환경지질
    • /
    • 제29권1호
    • /
    • pp.21-24
    • /
    • 1996
  • Inductively coupled plasma atomic emission spectrophotometer (ICP/AES) is a versatile modern instruments for the multi-element analysis, but quantitative analysis using ICP/AES with normal pneumatic nebulizer is not applicable for the measurement of elemental concentrations in water down to the drinkining water standard level except a few elements because of poor detection limits. However, the detection limit can be lowered enough to measure drinking water standard, if ultrasonic nebulizer and/or hydride vapor generator is attached. This method is tested with groundwater samples from Tajeon area. It is confirmed that the elemental concentrations in these samples are within the limit of drinking water standard for the most elements. However, uranium concentration is very high in some samples compared with the concentrations suggested by Environmental Protection Agency of U.S.A. There is no standard concentration level to this element in Korea and it should be prepared immediately.