• 제목/요약/키워드: Electrorheological fluid

검색결과 94건 처리시간 0.02초

Simulation study of magnetorheological testing cell design by incorporating all basic operating modes

  • Mughni, Mohd J.;Mazlan, Saiful A.;Zamzuri, Hairi;Yazid, Izyan I.M.;Rahman, Mohd A.A.
    • Smart Structures and Systems
    • /
    • 제14권5호
    • /
    • pp.901-916
    • /
    • 2014
  • Magnetorheological (MR) fluid is one of the field-responsive fluids that is of interest to many researchers due to its high yield stress value, which depends on the magnetic field strength. Similar to electrorheological (ER) fluid, the combination of working modes is one of the techniques to increase the performance of the fluids with limited focus on MR fluids. In this paper, a novel MR testing cell incorporated with valve, shear and squeeze operational modes is designed and constructed in order to investigate the behaviour of MR fluid in combined mode. The magnetic field distribution in the design concept was analyzed using finite element method in order to verify the effective areas of each mode have the acceptable range of flux density. The annular gap of valve and shear were fixed at 1 mm, while the squeeze gap between the parallel circular surfaces was varied up to 20 mm. Three different coil configurations, which were made up from 23 SWG copper wires were set up in the MR cell. The simulation results indicated that the magnetic field distributed in the squeeze gap was the highest among the other gaps with all coils were subjected to a constant applied current of 1 A. Moreover, the magnetic flux densities in all gaps were in a good range of magnitude based on the simulations that validated the proposed design concept. Hence, the 3D model of the MR testing cell was designed using Solidworks for manufacturing processes.

ER 유체를 이용한 회전식 약실 축계의 비틀림 진동 제어 (Torsional Vibration Control of a Rotating Chamber Shaft System Using Electrorheological Fluid)

  • 임승철;김기갑;길성진;심정수;차기업
    • 대한기계학회논문집A
    • /
    • 제35권1호
    • /
    • pp.17-24
    • /
    • 2011
  • 간헐 회전식 약실 계가 화력 대 무장 공간의 비율 관점에서 볼 때 중구경 자동포에 크게 유익하다고 보고되었다. 그러나 약실계의 핵심 부품인 평행 인덱스가 인덱스 터릿에 설치되는 캠종동절의 상대적으로 낮은 횡 강성으로 인하여 비틀림 방향으로 유연해지는 경향이 있으며, 이는 결국 터릿과 약실 사이의 연결 축이 상당한 크기의 비틀림 잔류 진동에 노출되어 탄 장전과 발사 시에 심각한 비정렬 문제를 야기시킬 수 있다. 이러한 맥락에서 본 논문에서는 상기 진동을 억제하는 ER 유체 작동기와 그에 적합한 반능동 제어 알고리듬을 제안하게 되었으며, 전체 계의 수학적 모델링과 컴퓨터 시뮬레이션을 통하여 그 성능이 만족스러움을 입증하였다.

ER밸브를 이용한 자동 하역 시스템의 제어 (I) -ER밸브의 모델링- (Control of Automatic Cargo Handling System Using ER Valves (I) -Modeling of ER Valves-)

  • 성금길;정달도;최승복
    • 한국정밀공학회지
    • /
    • 제18권9호
    • /
    • pp.45-52
    • /
    • 2001
  • This paper presents two different models of electrorheological(ER) valves which can be applicable to an automatic cargo handling system at the seaport. Four different ER fluids, which are commercially available, are adopted and their Bingham characteristics are experimentally evaluated with respect to the intensity of electric field. The field-dependent Bingham models are used in the design of two types of ER valves; single-type and divided-type. The governing equations of motion of the ER valves are derived and the principal design parameters are determined based on 200ton platform to be vertically controlled by the ER valves. Both pressure drops due to the applied field and current density required to operate the ER valves are analyzed. In addition, the pressure drops of the cylinder system are evaluated for both ER valves.

  • PDF

Vibration isolation with smart fluid dampers: a benchmarking study

  • Batterbee, D.C.;Sims, N.D.
    • Smart Structures and Systems
    • /
    • 제1권3호
    • /
    • pp.235-256
    • /
    • 2005
  • The non-linear behaviour of electrorheological (ER) and magnetorheological (MR) dampers makes it difficult to design effective control strategies, and as a consequence a wide range of control systems have been proposed in the literature. These previous studies have not always compared the performance to equivalent passive systems, alternative control designs, or idealised active systems. As a result it is often impossible to compare the performance of different smart damper control strategies. This article provides some insight into the relative performance of two MR damper control strategies: on/off control and feedback linearisation. The performance of both strategies is benchmarked against ideal passive, semi-active and fully active damping. The study relies upon a previously developed model of an MR damper, which in this work is validated experimentally under closed-loop conditions with a broadband mechanical excitation. Two vibration isolation case studies are investigated: a single-degree-of-freedom mass-isolator, and a two-degree-of-freedom system that represents a vehicle suspension system. In both cases, a variety of broadband mechanical excitations are used and the results analysed in the frequency domain. It is shown that although on/off control is more straightforward to implement, its performance is worse than the feedback linearisation strategy, and can be extremely sensitive to the excitation conditions.