• Title/Summary/Keyword: Electronics Control

Search Result 11,425, Processing Time 0.038 seconds

A General Purpose Inverter Set-Up for Power Electronics Laboratory Experiments

  • Kayakesen, Mustafa Erman;Cadirci, Isik
    • Journal of Power Electronics
    • /
    • v.10 no.4
    • /
    • pp.434-443
    • /
    • 2010
  • A general purpose experimental set-up has been designed and implemented for students to carry out various experiments on inverters in the power electronics laboratories of universities, during a few hours of laboratory work. This is the first inverter setup that incorporates hardware and software control, as well as an optional user interface in a laboratory experimental set-up of a single multi-purpose inverter, thus making the system versatile and very practical for both undergraduate and graduate students. The system can be controlled either by a computer or through a liquid crystal display (LCD) and a keypad control unit, and it constitutes a low-cost alternative to relatively expensive commercial teaching sets. The computer provides a user friendly interface and easier control for laboratory environments equipped with computers. The LCD and keypad units eliminate the need for a computer, which makes this system usable in the laboratory as a standalone unit as well.

LLC Resonant Converter Operating over a Wide Output Voltage Range by Varying the Input Voltage and Changing Operating Modes (입력전압 가변 및 동작 모드 변화를 통해 넓은 출력전압 범위에서 동작하는 LLC 공진컨버터)

  • Lee, Ji-Cheol;Joo, Jong-Seong;Heo, Ye-Chang;Marius, Takongmo;Kim, Eun-Soo;Jeon, Yong-Seog;Kook, Yoon-Sang
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.6
    • /
    • pp.517-526
    • /
    • 2017
  • In this paper, we propose an LLC resonant converter that operates over a wide controllable output voltage ($50V_{DC}$ to $800V_{DC}$) and shows high efficiency characteristics under all load conditions and output voltages. Two 3.3kW prototypes are designed for an experimental comparison between the variable frequency control (control scheme 1) and the variable input voltage($V_{IN}$) control (control scheme 2) mechanisms. The experimental results show that the variable input control mechanism demonstrates high efficiency under all loads and output voltages.

A Study on the Remote Control & Monitoring System for Wind Turbine System via Internet (인터넷기반의 풍력발전기 원격제어와 모니터링에 관한 연구)

  • Park, Jang-Hun;Chae, Jeong-Su;Mun, Seong-Ryong;Jeong, Jun-Ik;Lee, Ho-Soon;Rho, Do-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1395-1397
    • /
    • 2003
  • This paper is concerned with a client-server architecture for the remote control of wind turbine system over the internet network. Recently the development of internet are study in remote area machine control, observation, remote control (teleoperation) automation industrial system in several fields. One of the important problems which should be solved in the remote control is an irregular time delay problem. This research practiced emergency system on-off experiment to Internet. Finally, we apply it to a wind turbine system that consists of a remote control and network via internet. It is experimented that real time of internet remote control and stability of wind turbine system.

  • PDF

Mobile Target Speed Estimation in Urban Environments with Adaptive Power Control (도시환경에서 적응전력제어를 이용한 이동국 속도추정)

  • Lee, Hyeon-Cheol;Lee, Jong Tae;Ryu, Sang Burm;Kang, Eun Su
    • Journal of Satellite, Information and Communications
    • /
    • v.11 no.1
    • /
    • pp.46-50
    • /
    • 2016
  • The adaptive power control of Code Division Multiple Access (CDMA) systems for communications between User Equipments (UEs) with a link-budget based Signal-to-Interference Ratio (SIR) estimate which has distance information is applied to three inner loop power control algorithms. The speed estimation performances of these algorithms with their consecutive Transmit-Power-Control (TPC) ratios are compared to each other, and it is concluded that the speed can be estimated using the TPC ratio information of Consecutive TPC Ratio Step-size Closed Loop Power Control (CS-CLPC) and Fixed Step-size Power Control (FSPC).

External Force Control for Two Dimensional Contour Following ; Part 1. A Linear Control Approach

  • Park, Young-Chil;Kim, Sungkwun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10b
    • /
    • pp.130-134
    • /
    • 1992
  • The ability of a robot system to comply to an environment via the control of tool-environment interaction force is of vital for the successful task accomplishment in many robot application. This paper presents the implementation of external force control for two dimensional contour following task using a commercial robot system. Force accommodation is used since a constraint imposed in our work is not to modify the commercial robot system. A linear, decoupled model of two dimensional contour following system in the discrete time domain is derived first. Then the experimental verification of linear control is obtained using a PUMA 560 manipulator with standard Unimation controller, Astek FS6-120A six axis wrist force sensor attached externally to the arm and LSI-11173 microcomputer. Experimentally obtained data shows that the RMS contact force error is 0.8246 N when following the straight edge and 2.3768 N when following 40 mm radius curved contour.

  • PDF

Fuzzy PD Speed Controller for Permanent Magnet Synchronous Motors

  • Jung, Jin-Woo;Choi, Han-Ho;Kim, Tae-Heoung
    • Journal of Power Electronics
    • /
    • v.11 no.6
    • /
    • pp.819-823
    • /
    • 2011
  • This paper presents a fuzzy PD speed control scheme for the robust speed tracking of a permanent magnet synchronous motor (PMSM). Motivated by the common control engineering knowledge that transient performance can be improved if the P gain is big and the D gain is small in the beginning, a linearizing control scheme with a fuzzy PD controller is proposed. The global system stability is analyzed and the proposed control algorithm is implemented using a TMS320F28335 DSP. Simulation and experimental results are given to verify the effectiveness of the proposed method.

A Novel Control Technique for a Multi-Output Switched-Resonant Converter

  • Sundararaman, K.;Gopalakrishnan, M.
    • Journal of Power Electronics
    • /
    • v.13 no.6
    • /
    • pp.928-938
    • /
    • 2013
  • This paper proposes a novel control method for a multi-output switched-resonant converter. Output voltage can be regulated against variations in the supply voltage and load by controlling the voltage of the resonant capacitor (pulse amplitude control). Precise control is possible when pulse amplitude control is combined with pulse number control. The converter is analyzed, and design considerations are explained by using examples. Control implementation is described and load regulation and ripples are analyzed by simulation and hardware results. The topology is modified to obtain an additional negative output without any additional hardware other than a diode. The analysis of such a triple output converter with two positive outputs and one negative output is conducted and confirmed. The topology and control scheme are scalable to any number of outputs.

A Comparison of the performance of mean, median, and precedence control charts for nonnormal data

  • Kim, Jung-Hee;Lee, Sung-Im;Park, Heon-Jin;Lee, Jae-Cheol;Jang, Young-Chul
    • Proceedings of the Korean Statistical Society Conference
    • /
    • 2005.05a
    • /
    • pp.197-201
    • /
    • 2005
  • In this article, we will compare the performance of the mean control chart, the median control chart, the transformed mean control chart, the transformed median control chart, and the precedence control chart by simulation study. For control charts with transformed data, Yeo-Johnson transformation is used. Under the in-control condition, ARL's in all control charts coincide with the designed ARL in the normal distribution, but in the other distributions, only the precedence control chart provides the in-control ARL as designed. Under the out-of-control condition, the mean control chart is preferred in the normal distribution and the median control chart is preferred in the heavy-tailed distribution and the precedence control chart outperforms in the short-tailed distribution.

  • PDF

Proposed Distribution Voltage Control Method for Connected Cluster PV Systems

  • Lee, Kyung-Soo;Yamaguchi, Kenichiro;Kurokawa, Kosuke
    • Journal of Power Electronics
    • /
    • v.7 no.4
    • /
    • pp.286-293
    • /
    • 2007
  • This paper proposes a distribution voltage control method when a voltage increase condition occurs due to reverse power flow from the clustered photovoltaic (PV) system. This proposed distribution voltage control is performed a by distribution-unified power flow controller (D-UPFC). D-UPFC consists of a hi-directional ac-ac converter and transformer. It does not use any energy storage component or rectifier circuit, but it directly converts ac to ac. The distribution model and D-UPFC voltage control using the ATP-EMTP program were simulated and the results show the voltage increase control in the distribution system.

Real Time Control of an Induction Motor Using IMC Approach

  • Nghia, Duong Hoai;Nho, Nguyen Van;Bac, Nguyen Xuan;Lee, Hong-Hee
    • Journal of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.456-463
    • /
    • 2009
  • The paper presents a method for controlling induction motors using a nonlinear internal model control (IMC) approach. The process model and the inverse model are developed in the rotor flux coordinate. The main advantage of the proposed method is that it easily specifies the performance (steady state error, transient response, etc.) and the robustness of the controller by means of the IMC filters. Simulation results illustrate the effectiveness of the proposed method. Results on a real time system show that the control system has good performance and robustness against changes in motor parameters (rotor and stator resistances, rotor and stator inductances, rotor inertia).