• 제목/요약/키워드: Electronic energy meter

검색결과 28건 처리시간 0.019초

Development of DC Controller for Battery Control for Elevator Car

  • Lee, Sang-Hyun;Kim, Sangbum
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제13권2호
    • /
    • pp.103-111
    • /
    • 2021
  • Among transport vehicles, Special Vehicles (SVs) are seriously exposed to energy and environmental problems. In particular, elevator cars used when moving objects in high-rise buildings increase the engine's rotational speed (radian per second: RPM). At this time, when the vehicle accelerates rapidly while idling, energy consumption increases explosively along with the engine speed, and a lot of soot is generated. The purpose of this paper is to develop a bi-directional DC-DC converter for control of vehicle power and secondary battery used in an elevated ladder vehicle (EC) used in the moving industry. As a result of this paper, the performance test of the converter was conducted. The charging/discharging state of the converter was simulated using DC power supply and DC electronic load, and a performance experiment was conducted to measure the input/output power of the converter through a power meter. Through this experimental result, it was confirmed that the efficiency was more than 92% in Buck mode and Boost mode at maximum 1.2kW output.

ICP-AES에 의한 반도전재료의 불순물 측정 및 열적특성에 관한 연구 (A Study on Thermal Properties and Impurities Measurement of Semiconductive Shield by ICP-AES)

  • 이경용;최용성;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.489-494
    • /
    • 2004
  • In this paper, we investigated impurities content and thermal properties showing by changing the content of carbon black which is semiconductive materials for underground power transmission. Specimens were made of sheet form with the three of existing resins and the nine of specimens for measurement. Impurities content of specimens was measured by ICP-AES(Inductively Coupled Plasma Atomic Emission Spectrometer), and density of specimens were measured by density meter. And then heat capacity(${\Delta}H$) and melting temperature(Tm), specific heat(Cp) were measured by DSC(Differential Scanning Calorimetry). The dimension of measurement temperature was $0[^{\circ}C]\;to\;200[^{\circ}C]$, and rising temperature was $4[^{\circ}C/min]$. Impurities content was highly measured according to increasing the content of carbon black from this experimental result also density was increased according to these properties. Specially, impurities content values of the A1 and A2 of existing resins were measured more than 4000[ppm]. Heat capacity, melting temperature, and specific heat from the DSC results were simultaneously decreased according to increasing the content of carbon black. Because metallic impurities of carbon black having Fe, Co, Mn, A1 and Zn are rapidly passed kinetic energy increasing the number of times breaking during the unit time with the near particles according to increasing vibration of particles by the applied heat energy.

  • PDF

공간분활 및 영역열량측정에 의한 공평 자동난방운영시스템 구현 (System Implementation for Fair Automatic Heating Operation Based on Spatial Distributing and Zonal Calorie Measuring)

  • 한상철;류광렬
    • 한국정보통신학회논문지
    • /
    • 제23권8호
    • /
    • pp.910-916
    • /
    • 2019
  • 본 논문은 주거공간영역 별로 사용 난방열량을 측정하고 사용량을 자동으로 측정 분석하여 계량 운영 할 수 있는 공평관리 자동난방운영시스템의 구현이다. 난방공간은 4영역으로 분할하여 하나의 계량기로 유량과 열량이 계측된다. 이 시스템은 열량검출, 온도조절기, 밸브제어기, PC컨버터와 모니터링으로 구성된다. 난방 공간영역은 실내온도에 따라 열량 계산에 필요한 환수 온도가 측정되고 영역별 열량이 산출된다. 실험결과, 측정기기로 계측한 값과 비교하여 측정열량 값의 오차 범위는 1% 내이다. 기존의 유량계를 이용한 난방 분할 방식과 비교하면 난방 에너지 사용 비용이 약 7% 저감된다. 이 공평시스템은 향후에는 BEMS와 공동으로 연계하는 연구가 필요하다.

PRAM용 Cu-도핑된 Ge8Sb2Te11 박막의 특성 (Characteristics of Cu-Doped Ge8Sb2Te11 Thin Films for PRAM)

  • 김영미;공헌;김병철;이현용
    • 한국전기전자재료학회논문지
    • /
    • 제32권5호
    • /
    • pp.376-381
    • /
    • 2019
  • In this work, we evaluated the structural, electrical and optical properties of $Ge_8Sb_2Te_{11}$ and Cu-doped $Ge_8Sb_2Te_{11}$ thin films prepared by rf-magnetron reactive sputtering. The 200-nm-thick deposited films were annealed in a range of $100{\sim}400^{\circ}C$ using a furnace in an $N_2$ atmosphere. The amorphous-to-crystalline phase changes of the thin films were investigated by X-ray diffraction (XRD), UV-Vis-IR spectrophotometry, a 4-point probe, and a source meter. A one-step phase transformation from amorphous to face-centered-cubic (fcc) and an increase of the crystallization temperature ($T_c$) was observed in the Cu-doped film, which indicates an enhanced thermal stability in the amorphous state. The difference in the optical energy band gap ($E_{op}$) between the amorphous and crystalline phases was relatively large, approximately 0.38~0.41 eV, which is beneficial for reducing the noise in the memory devices. The sheet resistance($R_s$) of the amorphous phase in the Cu-doped film was about 1.5 orders larger than that in undoped film. A large $R_s$ in the amorphous phase will reduce the programming current in the memory device. An increase of threshold voltage ($V_{th}$) was seen in the Cu-doped film, which implied a high thermal efficiency. This suggests that the Cu-doped $Ge_8Sb_2Te_{11}$ thin film is a good candidate for PRAM.

소규모 마이크로그리드에서 프로슈머관리시스템의 구현 (Implementation of Prosumer Management System for Small MicroGrid)

  • 임수연;이태원
    • 한국정보전자통신기술학회논문지
    • /
    • 제13권6호
    • /
    • pp.590-596
    • /
    • 2020
  • 상용전력망과 계통연계가 어려운 도서지역에서는 독립적인 마이크로그리드로 생산된 에너지를 효율적으로 관리할 수 있는 방법을 찾는 것은 매우 중요한 일이다. 본 논문에서는 태양광과 풍력의 하이브리드 모델을 적용한 소규모 마이크로그리드에서 생산된 전력을 전력계측기와 수집된 데이터의 응답속도 테스트를 거쳐 P2P전력거래를 위한 프로슈머관리시스템을 구현하였다. 마이크로그리드 프로슈머 관리시스템의 전력망은 Mesh구조로 이루어져 있으며 P2P전력거래는 3곳의 독립적으로 구축된 off-grid 사이트에서 전력계측기와 DC전력전송기를 이용하여 테스트하였고, 이때 전력계측기의 측정값은 전압(평균값) : 380V + 0.9V, 전류(평균값) : + 0.01A, 전력 : 1000W ( - 1W)로 오차 허용범위인 ±1%이내로 나타나 그 유의성을 확인하였다. 실시간으로 50개의 데이터를 동시 전송하여 메인화면 0.32초, 일 발전량 2.61초, 누적발전량 2.77초, 전력거래 0.11초 등의 응답속도가 나타나 서버의 안정화를 확인하였다. 따라서 본 시스템은 한국전력의 중계 없이 독립적인 망으로 활용될 수 있는 P2P 전력거래시스템으로서 그 타당성이 입증되었다.

수리동력학적 분리장치에 의한 교량에서의 비점원 오염물질 처리시 운전변수와 분리효율에 관한 연구 (Operational Variables and Performance of Hydrodynamic Separator Treating Rainfall Runoff from Bridge)

  • 김연석;우강화;김영철
    • 한국물환경학회지
    • /
    • 제27권3호
    • /
    • pp.342-348
    • /
    • 2011
  • A hydrodynamic separator using natural free energy provided by bridge was operated for the treatment of stormwater runoff. The separator was automatically controlled by using electronic valve which is connected with pressure meter. Normally the separator was opened during dry days, but it was closed after the capture of first flush. The results indicated that the average pressure and the flow rate were directly affected by the rainfall intensity. The pressure was more than 3 meters as the rainfall intensity was above 5 mm/hr. The percent volume of underflow decreased as the pressure and flow rate increased, but the percent volume of overflow showed an opposite behavior. The concentration of total suspended solids (TSS) in underflow increased as a function of increasing pressure while it decreased in overflow. The TSS separation efficiency was evaluated based on mass balance. It ranged from 30% to 90% with the pressure ranging from 2 to 10 meters, and it was proportional to pressure and flow rate. The analysis of water balance indicated that around 13% of total runoff was captured by the separator as a first flush, and this runoff was separated as underflow and overflow with the respective percent volume of 29% and 71%. The pollutants budget was also examined based on mass balance. The results showed that the percent of TSS, $COD_{cr}$, TN and TP in underflow were 73%, 59%, 7.6% and 49%, respectively.

성능이 향상된 면적선량계(DAP) 개발 (Development of Enhanced DAP(Dose Area Product))

  • 이영지;이상헌;이승호
    • 전기전자학회논문지
    • /
    • 제23권2호
    • /
    • pp.739-742
    • /
    • 2019
  • 본 논문에서는 성능이 향상된 면적선량계(DAP)를 제안한다. 본 논문에서 제안한 성능이 향상된 면적선량계는 기존에 개발되었던 면적선량계를 최적화하였다. 성능이 향상된 면적선량계는 전하 적분기 및 ADC 회로의 최적화 설계, RS-485 통신용 Line transceiver의 최적화 설계, Display 회로의 최적화 설계, 연동 및 에이징을 위한 PC 기반 제어 프로그램 최적화 등을 수행하였다. 제안된 시스템의 성능을 평가하기 위하여 공인시험기관에서 실험한 결과는 Radiation dose dependence와 Radiation quality dependence는 4.2%의 측정 불확도가 측정되어 국제 표준인 ${\pm}15%$ 이하에서 정상동작 됨이 확인되었다. Energy range/Tube voltage는 30~150kV 구간에서 반응이 확인되었다. 센서필드간 감도차이와 센서필드간 면적선량 감도차이는 4.3%의 측정 불확도가 측정되어 국제 표준인 ${\pm}15%$ 이하에서 정상동작 됨이 확인되었다. 면적선량계의 재현성을 측정하기 위하여 10회 반복하여 측정한 결과 0%로 확인되어서 IEC60580 권고 사항인 2% 이하에서 정상동작 됨이 확인되었다. Digital resolution은 시간당 기준선량에 대해 오차 범위 내에서 $0.01{\mu}Gy{\cdot}m^2$의 최소단위로 측정되는 것을 확인되었다.

의료 및 산업용 X-선 발생장치의 선량평가를 위한 면적선량계(DAP) 개발 (Development of DAP(Dose Area Product) for Radiation Evaluation of Medical and Industrial X-ray generator)

  • 곽동훈;이상헌;이승호
    • 전기전자학회논문지
    • /
    • 제22권2호
    • /
    • pp.495-498
    • /
    • 2018
  • 본 논문에서는 의료 및 산업용 X-선 발생장치의 선량평가를 위한 면적선량계(DAP)의 시스템을 제안한다. 제안하는 시스템은 Ion-Chamber를 이용한 면적선량 측정기술을 기반으로 진단용 X-선 장치에 의해 발생된 피폭선량을 명확히 측정할 수 있다. 면적선량계의 하드웨어부는 공기 중에서 X-선에 의해 전리되는 전하의 양을 측정한다. 미소 전류를 통한 누적선량 측정을 위한 고속 처리 알고리즘부는 입력 손실 없이 낮은 구현비용(전력)으로 X-선에 의해 전리되는 전하의 양을 측정한다. X-선 발생장치의 동작에 동기화된 유무선 송수신 프로토콜부는 통신 속도를 향상시킨다. 연동 및 에이징을 위한 PC 기반 제어 프로그램부는 실시간으로 발생된 X-선량을 측정하여 PC용 GUI를 통해 측정 그래프 및 수치 모니터링이 가능하도록 한다. 제안된 시스템의 성능을 공인시험기관에서 평가한 결과, 각각의 에너지 대역(30, 60, 100, 150kV)에서 면적선량계에 측정되는 값이 선형적으로 증가됨을 확인할 수가 있었다. 또한 4등분한 지점에서 측정기의 지시치에 대한 표준편차가 ${\pm}1.25%$를 나타내어서 면적선량계가 위치에 관계없이 균일한 측정값을 나타냄을 확인하였다. 한편, ${\pm}4.2%$의 불확도가 측정되어서 국제 표준인 ${\pm}15%$ 이하에서 정상동작 됨이 확인되었다.