• Title/Summary/Keyword: Electronic Valve

Search Result 277, Processing Time 0.029 seconds

EEV Superheat Control of a Multi-type Heat Pump by Using Dither Signal (멀티형 히트펌프 전자팽창밸브의 디더 신호를 적용한 과열도 제어)

  • 한도영;표수환
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.11
    • /
    • pp.948-953
    • /
    • 2002
  • The electronic expansion valve (EEV) may be used to control the refrigerant flow rate for the multi-type heat pump. Stepping motor driven EEV may precisely control the refrigerant flow rate to meet each internal load requirement. To control the EEV, PI algorithm may be used. But the hysteresis of EEV deteriorates the performance of superheat control. To reduce the performance degradation, the PI algorithm along with the dither signal may be used. The dither signal, with about 10 times higher frequency than the system crossover frequency and about 10 times larger magnitude than the deadband of hysteresis, was selected for the superheat control of EEV. Experimental results showed the improvement of EEV control by adding the dither signal to the PI algorithm.

Design of PI and Feedforward Controller for Precise Temperature Control of Oil Cooler System (오일쿨러의 고정밀 온도 제어를 위한 PI 및 피드포워드 제어기 설계)

  • Byun, J.Y.;Jeong, S.K.
    • Journal of Power System Engineering
    • /
    • v.14 no.6
    • /
    • pp.89-95
    • /
    • 2010
  • This paper deals with design method of proportional-integral(PI) and feedforward controller for obtaining precise temperature and high energy efficiency of oil cooler system in machine tools. The compressor's speed and opening angle of an electronic expansion valve are controlled to keep reference value of temperature at oil outlet and superheat of an evaporator. Especially, the feedforward controller is added to suppress temperature fluctuation under abrupt disturbances. Through some experiments, the suggested method can control the target temperature within steady state error of ${\pm}0.l^{\circ}C$ and maximum overshoot $0.2^{\circ}C$ under abrupt disturbances.

Capacity Modulation of a Multi-Type Heat Pump System using PID Control with Fuzzy Logic (퍼지 로직 적용 PID 제어를 이용한 멀티형 열펌프의 용량조절)

  • 김세영;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.9
    • /
    • pp.810-817
    • /
    • 2001
  • Performance of a water-to-water multi-type heat pump system using R22 which has tow indoor units has been investigated experimentally. The refrigerant flow rate of each indoor unit was regulated by an electronic expansion valve and the total refrigerant flow rate of the system was controlled by a variable speed compressor. In the system, evaporator outlet pressure of refrigerant and outlet temperatures of secondary fluid from indoor units were selected as control variables. Experiments were executed for both cooling and heating modes using PID control method with fuzzy logic, and results of the test are compared with a classical PID method. In the case of PID control with fuzzy logic, the fuzzy control rules corrects PID parameters each time. Results show that PID control with fuzzy logic has the merits of quick response and reduced overshoot.

  • PDF

Evaporator Superheat Control of a Multi-type Air-conditioning/Refrigeration System (멀티형 공조/냉동시스템의 증발기 과열도 제어)

  • Kim, Tae-Sub;Hong, Keum-Shik;Sohn, Hyun-Chul
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.712-717
    • /
    • 2001
  • This paper investigates the control problem of evaporator superheat, i.e., the difference between the temperature of the refrigerant at the entrance region of an evaporator and that at the exit region, for multi-type air-conditioning/refrigeration systems. Mathematical equations describing the characteristics of compressor, condenser, evaporator, and electronic expansion valve are first derived. Then, the transfer functions from the current input of the electronic expansion valve to wall temperatures of evaporator tube at two-phase region and superheated region, respectively, are derived. The stability and performance of the closed loop system with a PI controller are analyzed by Nyquist stability criterion. Simulation results are provided.

  • PDF

Development of the Dynamic Simulation Program for the Multi-Inverter Heat Pump Air-Conditioner (멀티 인버터 히트펌프의 동특성 해석 프로그램의 개발)

  • ;;小山繁
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.11
    • /
    • pp.1079-1088
    • /
    • 2001
  • A dynamic simulation model was developed to analyse the transient characteristics of a multi-inverter heat pump. The programs included a basic air conditioning system such as a evaporator, condenser, compressor, linear electronic expansion valve (LEV) and by-pass circuit. The theoretical model was derived from mass conservation and energy conservation equations to predict the performance of the multi-inverter heat pump at various operating conditions. Calculated results were compared with the values obtained from the experiments at different operation frequencies of compressor, area of the LEV and configuration of indoor units operation. The results of the simulation model showed a good agreement with the experimental ones, so that the model could be used as an efficient tool for thermodynamic design and control factor design of air-conditioners.

  • PDF

Manufacture and Efficiency Evaluation of Oil Water Separator (유수분리기의 제작과 성능 평가)

  • 유연향;장동환;오무송;이은학;김태성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.160-164
    • /
    • 2000
  • This paper describes oil water separator using difference of electrical resistor. Oil is a non-conductive element and water is a relatively high conductive element. It is possible to detect water included in oil. Electric sensor is formed 8mm iron stick. Valve is operated With controller inputting signal of electric sensor. A experiment was done for necessary voltage in making program of controller. Oil water separator which was tested in field conditions was saved 7% of whole oil and was drained over 150% water than manual valve.

  • PDF

A Study on Analysis Technique for Solenoid Valve Applicable to Military Vehicle Transmission (군용차량 변속기에 적용할 수 있는 솔레노이드밸브 해석기술에 관한 연구)

  • Choi, Yun-Yong;Hong, Jung-Pyo
    • Journal of the Korea Society for Simulation
    • /
    • v.24 no.4
    • /
    • pp.29-34
    • /
    • 2015
  • Electronic of military vehicle that had relied on pure machinery system is ongoing. A large part of electronic of small-sized military vehicle has been already commercialized, which will expand to large-sized military vehicle field. Design of solenoid valve for automatic transmission is significantly important for stable driving performance of military vehicle. This research aims to develop simulation method which is capable of predicting performance of solenoid valve quantitatively according to its variation of ATF temperature. The research has been conducted in line with Maxwell, a magnetic field analysis program, and AMESim, a hydraulic analysis program. After simulation, it turned out to have been very similar to the test result in temperature range which excludes high temperature (over $120^{\circ}C$) and extremely low temperature (below $-20^{\circ}C$).

Myocardial Protective Effects of Shenfu Injection after Mitral Valve Replacement Surgery; A Systematic Review and Meta Analysis. (승모판의 인공판막 치환술후 삼부주사액의 심근보호효과에 관한 체계적 문헌고찰 및 메타분석)

  • Bong-Jin Shin;Ji-Ho Kim;Mu-Hyeok Ahn;Jung-Nam Kwon
    • The Journal of Korean Medicine
    • /
    • v.43 no.3
    • /
    • pp.164-180
    • /
    • 2022
  • Objectives: The purpose of this study was to evaluate the effects of shenfu injection on myocardial protective effects after mitral valve replacement surgery. Methods: We searched four international databases (PUBMED, Embase, Web of Science and CNKI) and three domestic electronic databases (OASIS, RISS and NDSL) for relevant studies. We used following keywords 'shenfu', 'valve replacement', 'mitral valve' at PUBMED, Embase and Web of Science; '二尖瓣', '参附注射液', '瓣膜' at CNKI and '이첨판', '판막', '삼부' at domestic databases. The search range included randomized controlled trials. When appropriate, meta-analyses were performed. Results: Seven randomized controlled trials were selected. All studies used Shenfu injection after mitral valve replacement surgery. We analyzed myocardial damage, cardiac function, patients' recovery rate, with various evaluation indicators. We also used meta-analysis for CK-MB, cTnI, MDA and voluntary recovery of heartbeat. CK-MB was analyzed in two subgroups: 8 hours and 24 hours after surgery. Std was -2.34(95% CI -4.10, -0.58) for 8 hours and -1.95(95% CI -4.79 to 0.88) for 24 hours. 8 hours showed statistically significant difference. cTnI appeared significant decrease with Std of -2.13(95% CI -2.60, -1.66). MDA showed significant decrease with Std of -0.95(95% CI -1.43 to -0.47). Voluntary recovery of heartbeat significantly increased with the odd ratio of 4.34(95% CI 1.76, 10.70). Conclusions: We suggest that Shenfu injection after Mitral valve replacement surgery may have significant myocardial protective effects in terms of reducing myocardial damages, reactive oxygen species, increasing cardiac function and patients' recovery after surgery. However, the evidence is limited, further research is required.

Cooling Performance Characteristics of 3RT Heat Pump System applied Electronic Expansion Valve (전자식 팽창밸브를 적용한 3RT급 히트펌프 시스템의 냉방 성능 특성)

  • Son, Chang-Hyo;Yoon, Jung-In;Choi, Kwang-Hwan;Ha, Soo-Jung;Jeon, Min-Ju;Park, Sung-Hyeon;Lee, Sang-Bong
    • Journal of Power System Engineering
    • /
    • v.21 no.6
    • /
    • pp.79-85
    • /
    • 2017
  • A heat pump system is a highly efficient, eco-friendly device which consumes a small amount of energy and supply a lot of energy for heat formation. In addition, it is a single device system that has low generation effect about carbon dioxide. There are many researches related to the electronic expansion valve and the heat pump, but the detailed data analysis of each influence is insufficient. In this study, the cooling capacity and COP of the heat pump system were investigated by varying frequency of the inverter connected to compressor, inlet temperature of chilled water into evaporator and inlet temperature of cooling water into condenser. The results are as follows : (1) The cooling capacity increased as the inverter frequency, inlet temperature of chilled water into evaporator increased, and inlet temperature of cooling water into condenser decreased. (2) The COP increased as the frequency of inverter, inlet temperature of cooling water into condenser decreased and the inlet temperature of chilled water into evaporator increased.

Effects of the electronic expansion valve and variable velocity compressor on the performance of a refrigeration system

  • Lago, Taynara G.S.;Ismail, Kamal A.R.;Nobrega, Claudia R.E.S.;Moura, Luiz F.M.
    • Advances in Energy Research
    • /
    • v.7 no.1
    • /
    • pp.1-19
    • /
    • 2020
  • Energy consumption of air-conditioning and refrigeration systems is responsible for about 25 to 30% of the energy demand especially in hot seasons. This equipment is mostly electricity dependent and their use in principle affects negatively the environment. Enhancing the energy efficiency of the existing equipment is important as one of the measures to reduce environment impacts. This paper reports the results of an experimental study to evaluate the impacts of the use electronic expansion valve and variable velocity compressor on the performance of vapor compression refrigeration system. The experimental rig is composed of two independent circuits one for the vapor compression system and the other is the secondary fluid system. The vapor compression system is composed of a forced air condenser unit, evaporator, hermetic compressor and expansion elements, while the secondary system has a pump for circulating the secondary fluid, and an air conditioning heat exchanger. The manufacturer's data was used to determine the optimal points of operation of the system and consequently tests were done to evaluate the influence of variation of the compressor velocity and the opening of the expansion device on the performance of the refrigeration system. A fuzzy logic model was developed to control the rotational velocity of the compressor and the thermal load. Fuzzy control model was made in LabVIEW software with the objective of improving the system performance, stability and energy saving. The results showed that the use of fuzzy logic as a form of control strategy resulted in a better energy efficiency.