• Title/Summary/Keyword: Electronic Float

Search Result 19, Processing Time 0.028 seconds

A Design and Implementation of CDMA based Electronic Float Flow Pattern System (CDMA기반 전자부자 흐름 패턴 시스템 설계 및 구현)

  • Kim, Dong-Hyun;Lee, Chae-Seok;Kim, Jong-Deok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.12
    • /
    • pp.2619-2627
    • /
    • 2012
  • The electronic float flow pattern system can predict a rate of flow of river by monitoring a location of float in remote with location measurement technology and a variety of communication technology. Now, to analyze the flow pattern of the natural streams, we use the manual floats in many forms. The measurement of a rate of flow using a manual float measures the distance and time of the manual float directly and uses it. It is inefficient for measurement method and exact a rate of flow of river. To overcome this problems, we designed and implemented the electronic float using CDMA, GPS, and RF module. Then, to get the location information and a rate of flow information, we designed and implemented the monitoring system for the electronic float flow pattern. The short life cycle of electronic float using the battery decreases the utility of the electronic float flow pattern system. Then, we design the power saving method to reduce the power of the electronic float in electronic float flow pattern system.

Optimal design of dual magnetic float type level gauge to detect a specific level (특정 레벨을 검출하기 위한 2단 Magnetic Float 타입 레벨 게이지의 최적 설계에 관한 연구)

  • Kim, Dong-Sok;Han, Jae-Man;Park, Gwan-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.308-316
    • /
    • 2008
  • For the measurement of liquid level in ship's cargo tank, ballast tank, fuel oil tank and fresh water tank, several types of gauge meter are used such as tubular type, magnetic float type, reflex type transparent type and welding pad type. Among them, magnetic float type gauge meter is environmental friendly device because it is free of power source and maintenance. The main obstacle of the device is relatively large error bound. In this paper, finite element method is used to design and analysis of the magnetic float type gauge meter. The operation of reed switch according to the magnetic field has been successfully described and agreed well with experimental measurement. The optimum geometry with combination of permanent magnet and reed switches are designed to achieve 98 % accuracy of fluid level.

Measurement of Velocity and Discharge In Natural Streams with the Electronic Float System (전자부자 시스템을 활용한 자연하천의 유속과 유량 측정)

  • Lee, Chan Joo;Kim, Won;Kim, Chi Young;Kim, Dong Gu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.4B
    • /
    • pp.329-337
    • /
    • 2009
  • In this study we briefly introduce the electronic float system based on the GPS and RF communication technology and present some field application results. The system is capable of operating 15 floats simultaneously for making discharge measurement. Since the electronic floats (EFs) acquire flow paths, they can improve velocity measurement accuracy up to 10%. Additionally, measured velocities by the EFs show good agreement with those by an ADCP. Relative difference in sub-section area calculated by the electronic and conventional float methods is -79~71% and, due to convergent tendency of floats flowing along near banks, it increases much larger. It is possible to improve accuracy up to 5~6% in making discharge measurement by the electronic floats at site with irregular flow paths and section arrangement. The electronic float system is capable of calculating more accurate velocity and section area using position information based on GPS. By real-time measurement of velocity, cross-section area and discharge, the electronic float system is expected to reduce manpower and improve accuracy, rapidity and efficiency of flood discharge measurements.

A Wide-field-of-view Table-ornament Display Using Electronic Holography

  • Daerak Heo;Hosung Jeon;Sungjin Lim;Joonku Hahn
    • Current Optics and Photonics
    • /
    • v.7 no.2
    • /
    • pp.183-190
    • /
    • 2023
  • Three-dimensional (3D) displays provide a significant advantage over traditional 2D displays by offering realistic images, and table-style displays in particular are ideal for generating 3D images that appear to float above a table. These systems are based on multiview displays, and are typically operated using temporal or spatial multiplexing methods to expand the viewing zone (VZ). The VZ is an expanded space that results from merging the sub-viewing zones (SVZs) from which an individual view is made. To increase the viewing angle, many SVZs are usually required. In this paper, we propose a table-ornament electronic holographic display that utilizes 3f parabolic mirrors. In holography, the VZ is not simply expanded but synthesized from SVZs to implement continuous motion parallax. Our proposed system is small enough to be applied as a table ornament, in contrast to traditional tabletop displays that are large and not easily portable. By combining multiview and holographic technologies, our system achieves continuous motion parallax. Specifically, our system projects 340 views using a time-multiplexing method over a range of 240 degrees.

Study on Reillumination of Hi-soo type Electronic Manometer (희수식 전자 맥진기의 재조명)

  • Kim, Eun-Hye;Kim, Byung-Soo;Kang, Jung-Soo
    • Journal of Haehwa Medicine
    • /
    • v.18 no.2
    • /
    • pp.37-45
    • /
    • 2009
  • In early 1970s, Electronic Manometers were researched and developed for modernization and objectification of pulse diagnosis. Method of finger pressing, also known as cuffs pressing, is essential for sensing a pulse wave. I think comprehension and deduction of problem from the existing Hi-soo type electronic manometer, will be important for making a better one. The Hi-soo type electronic manometer is constructed of cuff pressing type sensor, differential amplifier, transmitter and recorder. Pulse movement and pulse wave, gauging blood flow, is analyzed by pulse image of "Yixuerumen(醫學入門)". At standard of pulse wave, huanmai(緩脈) is distinguish from chishu(slow and fast, 遲數), fushen(float and sink, 浮沈), interference wave, modificated wave, and phase angel. The Hi-soo type electronic manometer had no explanation of formational mechanism, significantly different with pulse wave which is early known and reported. The strength of Hi-soo type electric manometer is use of cuff pressing type sensor. Above all, the importance of electric manometer is reading the pulse movement accurately then expressing it as pulse wave. From now on the improvement of precise sensor should make a progress.

  • PDF

Preparation and Its Properties of YBCO Superconductor Induced by Seeds

  • Shan, Y.Q.;Soh, D.W.;Fan, Z.G.;Men, M.F.;Wang, W.H.;Zhao, Z.X.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.371-373
    • /
    • 1998
  • The SmBa$_2$Cu$_3$O$\sub$x/ single crystals were used as seeds to induced YBCO growth in MTG process. As the result, the large bulk oriented YBCO superconductors were prepared with dimension of plane 21mm and 32mm in diameter and 10mm in height. The typical Jc value of the sample is 6.5${\times}$10$^4$A/$\textrm{cm}^2$ and its flux float force is 4.6N/$\textrm{cm}^2$. The oxygen absorption in large bulk textured YBCO samples in pure oxygen was studied at several constant temperatures. It can be divided into two steps: a chemical reaction step and a diffusion step.

  • PDF

Preparation and Its Properties of YBCO Superconductor Induced by Seeds

  • Shan, Y.Q.;Soh, D.W.;Fan, Z.G.;Men, M.F.;Wang, W.H.;Zhao, Z.X.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.491-493
    • /
    • 1998
  • The SmBa$_2$Cu$_3$O$\sub$x/ single crystals were used as seeds to induced YBCO growth in MTG process. As the result, the large bulk oriented YBCO superconductors were prepared with dimension of plane 21mm and 32mm in diameter and 10mm in height. The typical Jc value of the sample is 6.5${\times}$10$^4$A/$\textrm{cm}^2$ and its flux float force is 4.6N/$\textrm{cm}^2$. The oxygen absorption in large bulk textured YBCO samples in pure oxygen was studied at several constant temperatures. It can be divided into two steps: a chemical reaction step and a diffusion step.

  • PDF

Visibility Enhancement of Underwater Image Using a Color Transform Model (색상 변환 모델을 이용한 수중 영상의 가시성 개선)

  • Jang, Ik-Hee;Park, Jeong-Seon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.5
    • /
    • pp.645-652
    • /
    • 2015
  • In underwater, such as fish farm and sea, turbidity is increased by water droplets and various suspended, therefore light attenuation occurs depending on the depth also caused by the scattering effect of light float. In this paper, in order to improve the visibility of underwater images obtained from these aquatic environment, we propose a visibility enhancement method using a haze removal method based on dark channel prior and a trained color transform model. In order to train a color transform model, we used underwater pattern images captured from Pohang and Yeosu, and to measure the performance of the proposed method, we carried out experiment of visibility enhancement using underwater images collected from Yeosu, Geomundo and Philippines. The results show that the proposed method can improve the visibility of underwater images of various locations.

WAETER LEVEL CONTROL USING Z-80 MICROOMPUTER

  • Sugisaka, Masanori
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10b
    • /
    • pp.1899-1903
    • /
    • 1991
  • This paper presents a water level control method using Z-80 microcomputer. The process considered in this paper is one tank system which is described by an unknown nonlinear differential equation. The water level is measured by the end of bar installed at a float passing through 8 pair of photointerrupters located at equal distance. Therefore, the input data to 8255 which is interface between Z-80 and photointerrupters is discrete value, namely, value under 1. values from 1 to 8, and value upper 8. The water is pumped into the tank from a reservoir by switching on a relay connected to a moter and pump driving system. The pumping is stopped by switching off the relay. Experimental studies for two types of controllers are performed in order to investigate the control performance of water level of the water pumping system.

  • PDF

Velocity and discharge measurement by the electronic float system (전자부자 시스템을 이용한 유속과 유량의 측정)

  • Lee, Chan-Joo;Kim, Dong-Gu;Kim, Yong-Jeon;Kim, Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.410-414
    • /
    • 2009
  • 홍수 유량 측정에 주로 활용되는 봉부자법은 신속하고 간편하게 유량을 측정할 수 있지만, 부자의 유하 경로를 정확하게 알 수 없으므로 가정된 직선을 따라 유하하지 않을 경우 유속과 단면적 계산에 불확실성이 다소 크게 발생하는 단점이 있다. 또한 측정에 소요되는 시간이 짧지만, 대개 현장에서 유량 계산이 바로 이루어지지 못하므로 측정 유량의 적절성을 충분히 평가하지 못한다. 본 연구에서는 봉부자법의 장점은 살리고 단점을 개선할 수 있는 전자부자 시스템을 개발하고 이를 이용하여 유량을 산정하였다. 개발된 전자부자 시스템은 GPS에 의해 유하경로를 획득하여 RF 통신을 통해 실시간으로 기지국에 정보를 전송한다. 기지국은 3개 RF 채널을 통해 최대 15개의 전자부자의 위치 정보를 동시에 수집하며, 각 전자부자의 유하경로와 미리 측량한 단면 자료를 결합하여 측정과 동시에 자동으로 유속을 계산한다. 이렇게 계산된 유속은 지리정보와 결합되어 있으므로 하천의 평면 2차원적 흐름 특성을 나타내는데 활용될 수 있으며, 나아가 미리 측량된 단면 자료와 결합하여 측정과 동시에 즉각 유량이 얻어질 수 있다. 이러한 점에서 본 연구는 전자부자를 이용하여 현장에서 유속과 유량을 실측한 사례를 제시하고자 한다.

  • PDF