• Title/Summary/Keyword: Electronic Certification

Search Result 194, Processing Time 0.02 seconds

Design of Brushless Permanent Machine with Skewed Stator for Electrical Power Steering System (전동 조향 장치용 브러쉬리스 영구자석 전동기의 스테이터 스큐 설계)

  • Lee, Choong-Sung;Jung, Kyung-Tae;Hong, Jung-Pyo;Kim, Hae-Joong;Kim, Young-Kyun
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.6
    • /
    • pp.189-197
    • /
    • 2015
  • As enforced the regulation of fuel efficiency, the electrification of automotive components in internal combustion vehicle has been applied instead of hydraulic pressure. A typical example of such parts is the EPS (electric power steering), and it is applied to most automotive at present. In electric power steering system, the core component is motor. The reduction of cogging torque and torque ripple is required to improve steering feeling and reduce NVH (Noise Vibration Harshness) in EPS. Generally the skewed design of stator or rotor is applied in order to reduce cogging torque and torque ripple. This paper propose the design and analysis methodology of Brusheless PMSM (Permanent Magnet Synchronous Motor) which is applied to skewed stator. The proposed methodology is as follows: First Intial Design PMSM with skewed stator for EPS, Second Optimal design using RSM (Response surface method), Third Performance Analysis such as Phase Back EMF, Inductance, Load torque using FEA (Finite Element Method). Finally, the reliability of proposed design methodology will be verified through the experiments of prototype sample.

Endovascular Treatments Performed Collaboratively by the Society of Korean Endovascular Neurosurgeons Members : A Nationwide Multicenter Survey

  • Kim, Tae Gon;Kwon, Oki;Shin, Yong Sam;Sung, Jae Hoon;Koh, Jun Seok;Kim, Bum-Tae
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.5
    • /
    • pp.502-518
    • /
    • 2019
  • Objective : Since less invasive endovascular treatment was introduced to South Korea in 1994, a considerable proportion of endovascular treatments have been performed by neuroradiology doctors, and endovascular treatments by vascular neurosurgeons have recently increased. However, few specific statistics are known regarding how many endovascular treatments are performed by neurosurgeons. Thus, authors compared endovascular treatments collaboratively performed by vascular neurosurgeons with all cases throughout South Korea from 2013 to 2017 to elucidate the role of neurosurgeons in the field of endovascular treatment in South Korea. Methods : The Society of Korean Endovascular Neurosurgeons (SKEN) has issued annual reports every year since 2014. These reports cover statistics on endovascular treatments collaboratively or individually performed by SKEN members from 2013 to 2017. The data was requested and collected from vascular neurosurgeons in various hospitals. The study involved 77 hospitals in its first year, and 100 in its last. National statistics on endovascular treatment from all over South Korea were obtained from the Healthcare Bigdata Hub website of the Health Insurance Review & Assessment Service based on the Electronic Data Interchange (EDI) codes (in the case of intra-arterial (IA) thrombolysis, however, statistics were based on a combination of the EDI and I63 codes, a cerebral infarction disease code) from 2013 to 2017. These two data sets were directly compared and the ratios were obtained. Results : Regionally, during the entire study period, endovascular treatments by SKEN members were most common in Gyeonggido, followed by Seoul and Busan. Among the endovascular treatments, conventional cerebral angiography was the most common, followed by cerebral aneurysmal coiling, endovascular treatments for ischemic stroke, and finally endovascular treatments for vascular malformation and tumor embolization. The number of endovascular treatments performed by SKEN members increased every year. Conclusion : The SKEN members have been responsible for the major role of endovascular treatments in South Korea for the recent 5 years. This was achieved through the perseverance of senior members who started out in the midst of hardship, the establishment of standards for the training/certification of endovascular neurosurgery, and the enthusiasm of current SKEN members who followed. To provide better treatment to patients, we will have to make further progress in SKEN.

Analysis of Customer Evaluations on the Ethical Response to Service Failures of Foodtech Serving Robots (푸드테크 서빙로봇의 서비스 실패에 대한 직업윤리적 대응에 대한 고객 평가 분석)

  • Han, Jeonghye;Choi, Younglim;Jeong, Sanghyun;Kim, Jong-Wook
    • Journal of Service Research and Studies
    • /
    • v.14 no.1
    • /
    • pp.1-12
    • /
    • 2024
  • As the service robot market grows among the food technology industry, the quality of robot service that affects consumer behavioral intentions in the restaurant industry has become important. Serving robots, which are common in restaurants, reduce employee work through order and delivery, but because they do not respond to service failures, they increase customer dissatisfaction as well as increase employee work. In order to improve the quality of service beyond the simple function of receiving and serving orders, functions of recovery effort, fairness, empathy, responsiveness, and certainty of the process after service failure, such as serving employees, are also required. Accordingly, we assumed the type of failure of restaurant serving service as two internal and external factors, and developed a serving robot with a vocational ethics module to respond with a professional ethical attitude when the restaurant serving service fails. At this time, the expression and action of the serving robot were developed by adding a failure mode reflecting failure recovery efforts and empathy to the normal service mode. And by recruiting college students, we tested whether the service robot's response to two types of service failures had a significant effect on evaluating the robot. Participants responded that they were more uncomfortable with service failures caused by other customers' mistakes than robot mistakes, and that the serving robot's professional ethical empathy and response were appropriate. In addition, unlike the robot's favorability, the evaluation of the safety of the robot had a significant difference depending on whether or not a professional ethical empathy module was installed. A professional ethical empathy response module for natural service failure recovery using generative artificial intelligence should be developed and mounted, and the domestic serving robot industry and market are expected to grow more rapidly if the Korean serving robot certification system is introduced.

Development of control system for complex microbial incubator (복합 미생물 배양기의 제어시스템 개발)

  • Hong-Jik Kim;Won-Bog Lee;Seung-Ho Lee
    • Journal of IKEEE
    • /
    • v.27 no.1
    • /
    • pp.122-126
    • /
    • 2023
  • In this paper, a control system for a complex microbial incubator was proposed. The proposed control system consists of a control unit, a communication unit, a power supply unit, and a control system of the complex microbial incubator. The controller of the complex microbial incubator is designed and manufactured to convert analog signals and digital signals, and control signals of sensors such as displays using LCD panels, water level sensors, temperature sensors, and pH concentration sensors. The water level sensor used is designed and manufactured to enable accurate water level measurement by using the IR laser method with excellent linearity in order to solve the problem that existing water level sensors are difficult to measure due to foreign substances such as bubbles. The temperature sensor is designed and used so that it has high accuracy and no cumulative resistance error by measuring using the thermal resistance principle. The communication unit consists of two LAN ports and one RS-232 port, and is designed and manufactured to transmit signals such as LCD panel, PCT panel, and load cell controller used in the complex microbial incubator to the control unit. The power supply unit is designed and manufactured to supply power by configuring it with three voltage supply terminals such as 24V, 12V and 5V so that the control unit and communication unit can operate smoothly. The control system of the complex microbial incubator uses PLC to control sensor values such as pH concentration sensor, temperature sensor, and water level sensor, and the operation of circulation pump, circulation valve, rotary pump, and inverter load cell used for cultivation. In order to evaluate the performance of the control system of the proposed complex microbial incubator, the result of the experiment conducted by the accredited certification body showed that the range of water level measurement sensitivity was -0.41mm~1.59mm, and the range of change in water temperature was ±0.41℃, which is currently commercially available. It was confirmed that the product operates with better performance than the performance of the products. Therefore, the effectiveness of the control system of the complex microbial incubator proposed in this paper was demonstrated.