• Title/Summary/Keyword: Electron range

Search Result 1,836, Processing Time 0.029 seconds

Micro-drilling for fabricating MCP (MCP 제조를 위한 미소구멍가공에 관한 연구)

  • 이학구;방경구;김포진;이대길
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.923-928
    • /
    • 1997
  • An MCP (Microchannel Plate) is a secondary electron multiplier to detect and amplify electrons. An MCP has many rnicrochannels whose diameters range from 10 to 100pm and whose lengths range from 40 to 100times of the diameter. Each microchannel of the MCP amplifies electrons over IOOOtimes by the secondary electron emission. Even though MCPs have high performance for electron amplification, the application of MCPs is limited to high performance electronic equipments because of their high fabricating cost and the limit of increasing their size due to the conventional fabrication process. Therefore, in this work, microchannels of the MCP are manufactured by micro-drilling to reduce the cost of the MCP and to increase their size. Alumina green body with epoxy binder was machined for fabricating microchannels using a high speed air turbine spindle and micro-drills with diamond grinding abrasives. Then alumina MCP was fabricated through the sintering of the machined alumina green body.

  • PDF

Performance of Gas Electron Multiplier (GEM) detector

  • Han, S.H.;Moon, B.S.;Kim, Y.K.;Chung, C.E.;Kang, H.D.;Cho, H.S.
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.4
    • /
    • pp.343-348
    • /
    • 2003
  • We have investigated in detail the operating properties of Gas Electron Multiplier (GEM) detectors with a double conical and a cylindrical structure in a wide range of external fields and GEM voltages. With the double conical GEM, the gain gradually increased with time by 10%; whereas this surface charging was eliminated with the cylindrical GEM. Effective gains above 1000 were easily observed over a wide range of collection field strengths in a gas mixture of $Ar/CO_2(70/30)$. The transparency and electron collection efficiency were found to depend on the ratio of external field and the applied GEM voltage; the mutual influence of both drift and collection fields was found to be trivial.

Thermal Electret of the ZnO varistor (ZnO 바리스터의 열 일렉트렛트)

  • Ahn, Y.M.;Lee, S.S.;Park, S.H.;Hong, J.W.;Lee, S.P.;Lee, J.U.
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.817-820
    • /
    • 1988
  • Thermal Electet of the Zinc Oxide varistor has been studied in the temperature range of -130${\sim}200[^{\circ}C]$ and the electric field of 6[kV/m]. It appears that there are four peaks of thermally stimulated current; ${\alpha},\;{\beta},\;{\gamma}$ and ${\delta}$ spectra appearing at the temperature range of 160, 130, 20 and $-30[^{\circ}C]$, respectively. It seems that the origins of ${\alpha},\;{\beta},\;{\gamma}$ and ${\delta}$ peaks are associated with the depolarization of donor ions in the depletion layer, the detrapping of trapped electron in the surface, the detrapping of trapped electron in the donor level and the detrapping of trapped electron between grain and intergranular, respectively.

  • PDF

The Study of the insulation Charateristic in $SF_6$+$N_2$ mixture gas ($SF_6$+$N_2$ 혼합기체의 절연특성에 관한 연구)

  • 박명진;전병훈;하성철
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.592-595
    • /
    • 2000
  • The electron transport coefficients in $SF_6$+$N_2$ gas is analyzed in range of E/P values from 70~240(V/cm $Torr^{-1}$) at 2$0^{\circ}C$ by Boltzmann method that using set of electron collision cross sections determined by authors. The result of this Boltzmann simulation such as ionisation coefficient, attachment coefficient, effective ionisation coefficient and breakdown voltage are in nearly agreement with the respective experimental and theoretical for a range of E/P.

  • PDF

Study on Characteristics of Dose Distribution in Tissue of High Energy Electron Beam for Radiation Therapy (방사선 치료용 고에너지 전자선의 조직 내 선량분포 특성에 관한 연구)

  • Na, Soo-Kyung
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.14 no.1
    • /
    • pp.175-186
    • /
    • 2002
  • The purpose of this study is directly measure and evaluate about absorbed dose change according to nominal energy and electron cone or medical accelerator on isodose curve, percentage depth dose, contaminated X-ray, inhomogeneous tissue, oblique surface and irradiation on intracavitary that electron beam with high energy distributed in tissue, and it settled standard data of hish energy electron beam treatment, and offer to exactly data for new dote distribution modeling study based on experimental resuls and theory. Electron beam with hish energy of $6{\sim}20$ MeV is used that generated from medical linear accelerator (Clinac 2100C/D, Varian) for the experiment, andwater phantom and Farmer chamber md Markus chamber und for absorbe d dose measurement of electron beam, and standard absorbed dose is calculated by standard measurements of International Atomic Energy Agency(IAEA) TRS 277. Dose analyzer (700i dose distribution analyzer, Wellhofer), film (X-OmatV, Kodak), external cone, intracavitary cone, cork, animal compact bone and air were used for don distribution measurement. As the results of absorbed dose ratio increased while irradiation field was increased, it appeared maximum at some irradiation field size and decreased though irradiation field size was more increased, and it decreased greatly while energy of electron beam was increased, and scattered dose on wall of electron cone was the cause. In percentage depth dose curve of electron beam, Effective depth dose(R80) for nominal energy of 6, 9, 12, 16 and 20 MeV are 1.85, 2.93, 4.07, 5.37 and 6.53 cm respectively, which seems to be one third of electron beam energy (MeV). Contaminated X-ray was generated from interaction between electron beam with high energy and material, and it was about $0.3{\sim}2.3\%$ of maximum dose and increased with increasing energy. Change of depth dose ratio of electron beam was compared with theory by Monte Carlo simulation, and calculation and measured value by Pencil beam model reciprocally, and percentage depth dose and measured value by Pencil beam were agreed almost, however, there were a little lack on build up area and error increased in pendulum and multi treatment since there was no contaminated X-ray part. Percentage depth dose calculated by Monte Carlo simulation appeared to be less from all part except maximum dose area from the curve. The change of percentage depth dose by inhomogeneous tissue, maximum range after penetration the 1 cm bone was moved 1 cm toward to surface then polystyrene phantom. In case of 1 cm and 2 cm cork, it was moved 0.5 cm and 1 cm toward to depth, respectively. In case of air, practical range was extended toward depth without energy loss. Irradiation on intracavitary is using straight and beveled type cones of 2.5, 3.0, 3.5 $cm{\phi}$, and maximum and effective $80\%$ dose depth increases while electron beam energy and size of electron cone increase. In case of contaminated X-ray, as the energy increase, straight type cones were more highly appeared then beveled type. The output factor of intracavitary small field electron cone was $15{\sim}86\%$ of standard external electron cone($15{\times}15cm^2$) and straight type was slightly higher then beveled type.

  • PDF

Applications of the Scanning Electron Microscope (주사형(走査型) 전자현미경(電子顯微鏡)의 응용분야(應用分野))

  • Kim, Yong-Nak
    • Applied Microscopy
    • /
    • v.2 no.1
    • /
    • pp.39-46
    • /
    • 1972
  • There are many kinds of microscopes suitable for general studies; optical microscopes(OM), conventional transmission electron microscopes (TEM), and scanning electron microscopes(SEM). The optical microscopes and the conventional transmission electron microscopes are very familiar. The images of these microscopes are directly formed on an image plane with one or more image forming lenses. On the other hand, the image of the scanning electron microscope is formed on a fluorescent screen of a cathode ray tube using a scanning system similar to television technique. In this paper, the features and some applications of the scanning electron microscope will be discussed briefly. The recently available scanning electron microscope, combining a resolution of about $200{\AA}$ with great depth of field, is favorable when compared to the replica technique. It avoids the problem of specimen damage and the introduction of artifacts. In addition, it permits the examination of many samples that can not be replicated, and provides a broader range of information. The scanning electron microscope has found application in diverse fields of study including biology, chemistry, materials science, semiconductor technology, and many others. In scanning electron microscopy, the secondary electron method. the backscattererd electron method, and the electromotive force method are most widely used, and the transmitted electron method will become more useful. Change-over of magnification can be easily done by controlling the scanning width of the electron probe. It is possible. to continuously vary the magnification over the range from 100 times to 1.00,000 times without readjustment of focusing. Conclusion: With the development of a scanning. electron microscope, it is now possible to observe almost all-information produced through interactions between substances and electrons in the form of image. When the probe is properly focused on the specimen, changing magnification of specimen orientation does not require any change in focus. This is quite different from the conventional transmission electron microscope. It is worthwhile to note that the typical probe currents of $10^{-10}$ to $10^{-12}\;{\AA}$ are for below the $10^{-5}$ to $10^{-7}\;{\AA}$ of a conventional. transmission microscope. This reduces specimen contamination and specimen damage due to heatings. Outstanding features of the scanning electron microscope include the 'stereoscopic observation of a bulky or fiber specimen in high resolution' and 'observation of potential distribution and electromotive force in semiconductor devices'.

  • PDF

Cytochrome c Peroxidase: A Model Heme Protein

  • Erman, James E.;Vitello, Lidia B.
    • BMB Reports
    • /
    • v.31 no.4
    • /
    • pp.307-327
    • /
    • 1998
  • Cytochrome c peroxidase (CcP) is a yeast mitochondrial enzyme which catalyzes the reduction of hydrogen peroxide to water using two equivalents of ferrocytochrome c. The CcP/cytochrome c system has many features which make it a very useful model for detailed investigation of heme protein structure/function relationships including activation of hydrogen peroxide, protein-protein interactions, and long-range electron transfer. Both CcP and cytochrome c are single heme, single subunit proteins of modest size. High-resolution crystallographic structures of both proteins, of one-to-one complexes of the two proteins, and a number of active-site mutants are available. Site-directed mutagenesis studies indicate that the distal histidine in CcP is primarily responsible for rapid utilization of hydrogen peroxide implying significantly different properties of the distal histidine in the peroxidases compared to the globins. CcP and cytochrome c bind to form a dynamic one-to-one complex. The binding is largely electrostatic in nature with a small, unfavorable enthalpy of binding and a large positive entropy change upon complex formation. The cytochrome c-binding site on CcP has been mapped in solution by measuring the binding affinities between cytochrome c and a number of CcP surface mutations. The binding site for cytochrome c in solution is consistent with the crystallographic structure of the one-to-one complex. Evidence for the involvement of a second, low-affinity cytochrome c-binding site on CcP in long-range electron transfer between the two proteins is reviewed.

  • PDF

Determination of electron energy distribution functions in radio-frequency (RF) and microwave discharges (RF/마이크로웨이브 방전에서의 전자에너지 분포함수의 결정)

  • 고욱희;박인호;김남춘
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.4
    • /
    • pp.424-430
    • /
    • 2001
  • An electron Boltzmann equation is solved numerically to calculate the electron energy distribution functions in plasma discharge which is generated by radio-frequency (RF) and microwave frequency electric field. The maintenance field strengths are determined self-consistently by solving the homogeneous electron Boltzmann equation in the Lorentz approximation expressed by 2nd order differential equation and an additional particle balance equation expressed by integro-differential equation. By using this numerical code, the electron energy distribution functions in argon discharge are calculated in the range from RF to microwave frequency. The influence of frequency of the HF electric field on the electron energy distribution functions and ionization rate are investigated.

  • PDF

A Study on the Electron Energy Distribution Function in $SF_6+Ar$ Mixtures Gas used by MCS-BE Algorithm ($SF_6+Ar$ 혼합기체의 MCS-BE 알고리즘에 의한 전자에너지 분포함수)

  • Kim, Sang-Nam;Ha, Sung-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2000.07e
    • /
    • pp.17-21
    • /
    • 2000
  • A Study on the electron energy distribution function in $SF_6+Ar$ mixtures gas used by MCS-BE algorithm, the electron swam parameters in the 0.5% and 0.2% $SF_6+Ar$ mixtures are measured by time of flight method over the E/N(Td) range from 30 to 300(Td). A two-term approximation of the Boltzmann equation analysis and Monte Carlo simulation have been also used to study electron transport coefficients. The electron energy distribution function has been analysed in $SF_6$ gas and $SF_6+Ar$ mixtures at E/N : 200(Td) for a case of the equilibrium region in the mean electron energy. The measured results and the calculated results have been compared each other.

  • PDF

Synthesis of Silicon Carbide Nanowhiskers from Coconut Fibres and Sol-Gel Derived Silica

  • Raman, V.;Bhatia, G.;Mishra, A.;Saha, M.;Sengupta, P.R.;Srivastava, A.K.
    • Carbon letters
    • /
    • v.7 no.3
    • /
    • pp.166-170
    • /
    • 2006
  • Silicon carbide whiskers ($SiC_w$) having the diameter in the range of 20-80 nm were synthesised from coconut fibres through sol-gel process. The coconut fibres were impregnated with tetraethoxysilane and methyltriethoxysilane derived sol and pyrolyzed at $1400^{\circ}C$ in argon. X-ray of the pyrolyzed samples showed the formation of ${\beta}$-SiC.

  • PDF