• 제목/요약/키워드: Electron capture detector

검색결과 91건 처리시간 0.029초

5% $Cr_2O_3/{\gamma}-Al_2O_3$ Catalysts Synthesized as Research for Oxidation Activation of Trichloroethylene

  • Myung, So-Young;Suh, Myung-Gyo;Lee, Yong-Hee
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2005년도 Proceedings of KSEH.Minamata Forum
    • /
    • pp.78-82
    • /
    • 2005
  • The research addressed the ability of 5% $Cr_2O_3/{\gamma}-Al_2O_3$ to catalytically oxidize trichloroethylene(TCE). In order to determine which procedure gives the most active catalyst among the attempted several procedures, catalytic oxidation reaction of TCE was conducted to every catalysts synthesized according to different process in tubular reactor system, which had functional relationships with temperature and space velocity. The ratio of TCE conversion was analyzed by gas chromatography with electron capture detector.

  • PDF

수입 과일중 2,4-D의 잔류분석법 및 잔류량 연구 (Studies on the Analytical Methods and Quantity of Residual 2,4-D in Imported Fruits)

  • 홍무기
    • 한국식품위생안전성학회지
    • /
    • 제9권2호
    • /
    • pp.89-94
    • /
    • 1994
  • A simple, safe, and sensitive gas chromatographic method using packed column and electron capture detector to analyze 2, 4-D herbicide in imported lemon, grapefruit, and orange was described and its usefulness evaluated. In this scheme of analysis the acid herbicide was converted into its alkyl esters by an one-step reaction prior to analysis. The herbicide in the fruits was extracted with ethyl acetate and partitioned against dichloromethane for purification, and the extracts finished partitioning were derivatized with alcohol, using sulfuric acid as a catalyst to form the corresponding alkyl derivatives. The analytical scheme studiedwas found to be applicable for the herbicide in the fruits without a column clean-up procedure. The mean recoveries of the herbicide for lemon samples fortified at 0.1 mg/kg and 1.0 mg/kg were 93% and 95%, respectively. The detection limit was 0.5 $\mu\textrm{g}$/kg for 2.4-D methyl ester.

  • PDF

Biological Monitoring of Human Exposure to Volatile Halogenated Hydrocarbons Using Urinalysis with Capillary GC-ECD

  • Jung, Won-Tae;Sohn, Dong-Hun
    • Archives of Pharmacal Research
    • /
    • 제15권2호
    • /
    • pp.109-114
    • /
    • 1992
  • For the risk assessment of human exposure to volatile halogenated hydrocarbons, a dynamic purge trap/on-column cryofocusing method using capillary gas chromatograph-$^{63}Ni$ electron capture detector and thermal desorption unit was applied to analyze the free forms, metabolites of 1, 1, 2-trichloroethylene and 1, 1, 2, 2-tetrachloroethylene. The urine sample was diluted with distilled water, hydrolyzed and sealed. Then the inert gas was infused to purge out free 1, 1, 2-trichloroethylene, free 1, 1, 2, 2-tetrachloroethylene and urichloroethanol. These compounds were trapped to $Tenax^R$ / GC-gas trap device throughout clean up tube. Being undertectable to gas chromatograph directly, trichloroacetic acid was methyl esterificated and trapped in the manner above mentioned. The optimal incubation time to get best recovery of methyl ester was 4 hours at $60^circ$C. The concentrations of free volatile halogenated hydrocarbons and their metabolites in urine were obtained of free volatile halogenated hydrocarbons and their metabolites in urine were obtained from 5 healthy volunteers. This analytical method is expected to make the biological monitoring more precise and convenient.

  • PDF

유통 한약재의 잔류농약 및 잔류이산화황의 함량 분석 (The analysis of Residual Pesticides and Sulfur Dioxide in Commercial Medicinal Plants)

  • 김태희;장설;이아름;이아영;최고야;김호경
    • 대한본초학회지
    • /
    • 제27권6호
    • /
    • pp.43-48
    • /
    • 2012
  • Objectives : This study was investigated to determine the contents of pesticide residues and sulfur dioxide residues in commercial herbal medicines in Korea. Methods : Chromatographic test was performed on 100 samples consisted with 10 kinds of medicinal plants including improted and domestic products. To establish 19 pesticide residues (DDE, DDD, DDT, Dieldrin, Methoxychlor, BHC isomers, Aldrin, Endosulfan isomers, Endrin, Captan, Procymidone, Chlorpyrifos and Imidacloprid) in commercial herbal medicines, chromatographic equipments were used with the gas chromatography-mass detector and gas chromatography-electron capture detector for qualitative analysis. The imidacloprid analysis was performed by high performance liquid chromatograpgy-ultraviolet detector at 270 nm UV wavelength. The contents of sulfur dioxides were analyzed by modified Monnier-Williams method. All methods were based on notification procedure of Korea Food & Drug Administration (KFDA). Results : The residual pesticides were not founded in improted and domestic samples. Among 100 samples, the residues of sulfur dioxide in 73 samples were not detected and 25 samples showed contents in the range of 0~21.90 mg/kg. The excess samples of MRLs were 2 samples (30 mg/kg to medicinal herbs), Asiasari Radix et Rhizoma (Imported product) and the average amount of sulfur dioxide in 2 unsuitable samples were 14.83 mg/kg. These samples were found to transgress KFDA regulatory guidance of residual sulfur dioxide. Conclusion : These results are able to use as basic data to improve the reliability and value of commercial medicinal herbs.

주곡중의 잔류농약분석에 관한 연구 (Comparative Studies on the Analysis of Pesticide Residues. in Rice, Barley and Wheat)

  • 박승희
    • 한국응용곤충학회지
    • /
    • 제13권4호
    • /
    • pp.235-243
    • /
    • 1974
  • 산지별로 채취된 쌀, 보리, 밀에 함유된 잔류농약(유기수은제 및 유기감소제)을 Dithizone법과 GLC법으로 비교분석한 바 이에서 얻은 결과를 요약하면 다음과 같다. 1. Recovery는 유기수은에 있어서 TLC법$93\%$.에 비하여 GLC법$98\%$이 양호했고, 유기감소제는 GLC법으로 평균 약 $93\%$였다. 2. 시료중 유기수은의 잔류수준은 Dithizone법으로 쌀에 있어서 ND-0.053, .보리는 ND-0.051, 밀은 ND-0.033pm이었고, GLC법으로는 쌀은 trace(less than 0.002ppm)-0.036, 보리는 trace-0.030, 밀은 trace-0.025ppm으로 GLC법이 다소 낮은 수치였다. 3. 유기감소제의 잔류수준은 GLC법으로, 쌀에 있어서 BHC(trace-0.0090ppm), DDT(ND-0.0001ppm), Aldrin(trace-0.0032ppm), Heptachlor(race-0.0031ppm), Dieldrin(ND-0.0092ppm), Endrin(ND-0.0057ppm)이었는데, 수은화합물과 모두 공인최대허용량에 월등히 미달되는 안전수준이었다. 4. Column packing은 유기수은분리에는 $10\%$-DEGS/chromosorb-W,A,W., 유기감소제에는 $3\%$-DC-200/chromosorb-W,A.W.,가 적당하였는데, 유기수은제의 injection sample의 조제에 있어서 ?를 겸한 정제와 reduced glutatione에 의한 유출처리는 ghost peak의 소거와 성분 peak의 완전분리에 효과가 컸으며 검출감도도 높았다.

  • PDF

시설재배 참외 중 살균제의 생물학적 반감기 (Biological Half-lives of Fungicides in Korean Melon under Greenhouse Condition)

  • 이주희;전영환;신갑식;김효영;박은정;김태화;김장억
    • 한국환경농학회지
    • /
    • 제28권4호
    • /
    • pp.419-426
    • /
    • 2009
  • This study was conducted to know the biological half-lives and dissipation patterns of fungicides, pyrimethanil, chlorothalonil and tetraconazole in Korean melon under green house condition. The instrument for analyzing pyrimethanil and chlorothalonil was HPLC equipped with UV detector. Initial residue amounts of pyrimethanil were 0.16 mg/kg at recommended rate and 0.28 mg/kg at double recommended rate in Korean melon. The biological half-lives of pyrimethanil were 11.2 days at recommended rate and 10.1 days at double recommended rate in Korean melon. In case of chlorothalonil, initial residue amounts of chlorothalonil were 0.06 mg/kg at recommended and 0.11 mg/kg at double recommended rate in Korean melon. The biological half-lives of chlorothalonil in Korean melon were 3.4 days at recommended rate and 6.6 days at double recommended rate. The instrument for analyzing tetraconazole was GLC equipped with electron capture detector. Initial residue amounts of tetraconazole were 0.14 mg/kg at recommended and 0.22 mg/kg at double recommended rate in Korean melon, respectively. The biological half-lives of tetraconazole were 9.6 days at recommended rate and 18.5 days at double recommended rate in Korean melon.

Canola oil is an excellent vehicle for eliminating pesticide residues in aqueous ginseng extract

  • Cha, Kyu-Min;Lee, Eun-Sil;Kim, Il-Woung;Cho, Hyun-Ki;Ryu, Ji-Hoon;Kim, Si-Kwan
    • Journal of Ginseng Research
    • /
    • 제40권3호
    • /
    • pp.292-299
    • /
    • 2016
  • Background: We previously reported that two-phase partition chromatography between ginseng water extract and soybean oil efficiently eliminated pesticide residues. However, an undesirable odor and an unpalatable taste unique to soybean oil were two major disadvantages of the method. This study was carried out to find an alternative vegetable oil that is cost effective, labor effective, and efficient without leaving an undesirable taste and smell. Methods: We employed six vegetable oils that were available at a grocery store. A 1-mL sample of the corresponding oil containing a total of 32 pesticides, representing four categories, was mixed with 10% aqueous ginseng extract (20 mL) and equivalent vegetable oil (7 mL) in Falcon tubes. The final concentration of the pesticides in the mixture (28 mL) was adjusted to approximately 2 ppm. In addition, pesticides for spiking were clustered depending on the analytical equipment (GC/HPLC), detection mode (electron capture detector/nitrogen-phosphorus detector), or retention time used. Samples were harvested and subjected to quantitative analysis of the pesticides. Results: Soybean oil demonstrated the highest efficiency in partitioning pesticide residues in the ginseng extract to the oil phase. However, canola oil gave the best result in an organoleptic test due to the lack of undesirable odor and unpalatable taste. Furthermore, the qualitative and quantitative changes of ginsenosides evaluated by TLC and HPLC, respectively, revealed no notable change before or after canola oil treatment. Conclusion: We suggest that canola oil is an excellent vehicle with respect to its organoleptic property, cost-effectiveness and efficiency of eliminating pesticide residues in ginseng extract.

일부 한국 성인 여성들의 혈중 PCBs 농도 및 그 노출요인의 연구 (The Concentrations of PCBs in the Serum and Theri Predictors of Exposure n Korean Women)

  • 민선영;정문호;이강숙;노영만;구정환
    • 한국환경보건학회지
    • /
    • 제26권2호
    • /
    • pp.97-107
    • /
    • 2000
  • PCBs [Polychlorinated biphenyls] are halogenated aromatic compounds with the empirical formula C12H10-nCln(n=1~10), and are a mixture of possible 209 different chlorinated congeners. PCBs were widely used as dielectric fluids for capacitors, transformers, plasticizers, lubricant inks, and paint additives. once released into the environment, PCBs persist for years because they are so resistant to degradation. In addition to their high degree of lipophilicity. In 1970s, the worldwide production of PCBs seem to be still in use. The environmental load of PCBs was prohibited since 1983 in Korea. In spite of these actions, many PCBs seem to be still in use. The environmental load of PCBs will continue to be recycled through air, land, water, and the biosphere for decades to come. This study was conducted to measure the concentrations of PCBs I the serum samples of 112 women by GC/MSD(Hewlett Packard 5897 Gas Chromatography-Mass Chromatography Detector) and CG/ECD(Hewlett Packard 5890 series-II gas chromatography-Electron capture detector, U.S.A). The main results of this study were as follows; The mean and standard deviation of serum PCBs were 3.613, 0.759 ppb, respectively and median of it was 3.828 ppb. The correlation coefficients of the concentrations of 13 PCB congeners ranged from 0.7913 to 0..9985 and were significantly correlated between each items(p=0.0001). The PCB concentrations were positively associated with age(simple linear regression; R2=0.86, =0.08023, p<0.001) and with total lipids in serums(simple linear regression; R=0.7058, =0.00486, p<0.001). The age adjusted model (Y=$\beta$0+$\beta$1age+$\beta$2X) was applied for possible predictors of PCBs levels in serum. For BMI(Body Mass Index), major residential area, and fish, meat, and dairy consumption, there was no association with PCBs levels, Also there was negative association for the number of pregnancy and lactation period with PCBs levels.

  • PDF

Discrimination of Ginseng Habitat by Using Instrumental Analysis Techniques

  • Sohn H. J.;Lee S. K.;Cho B. G.;Kim S. J.;Lee N. Y.;Choi D. S.;Jeong M. S.;Bae H. R.;Yang J. W.
    • 고려인삼학회:학술대회논문집
    • /
    • 고려인삼학회 2002년도 학술대회지
    • /
    • pp.238-252
    • /
    • 2002
  • In order to screen out indicators for the discrimination of ginseng habitat, some physical and chemical characteristics of Korean red ginsengs (94 kinds) and Chinese red ginsengs (50 kinds) were analyzed by using a rheometer, an electronic nose system, a combined technique of solid phase micro-extraction (SPME) and gas chromatograph equipped with an electron capture detector (GC/ECD), an X-ray fluorescence spectrometer (XRF), an inductively coupled plasma mass spectrometer (ICP/MS), a near infrared spectrometer (NIRs) and high performance liquid chromatography equipped with evaporative light scattering detector (HPLC/ELSD). The results are summarized as follows: (i) The rhizome strengths of Korean red ginsengs were significantly higher than those of Chinese red ginsengs. (ii) The electronic nose patterns of Korean red ginsengs were significantly different from those of Chinese red ginsengs. (iii) Some unidentified peaks were detected not in the headspace of Korean red ginsengs but in the headspace of Chinese red ginsengs when the headspace volatiles prepared by the SPME technique were analyzed by GC/ECD. (iv) Either the content ratios of K to Ca or Mn to Fe were significantly different between Korean red ginsengs and Chinese red ginsengs. (v) The reflectance ratios of NIRs wavenumbers such as $904\;cm^{-1}\;to\;1088\;cm^{-1}$ for Korean red ginsengs were significantly different from those for Chinese red ginsengs. (vi) The content ratios of ginsenoside-Rg to ginsenoside-Re of Korean red ginsengs were significantly higher than those of Chinese red ginsengs. These results indicate that the rhizome strength, the electronic nose pattern, the occurrence of ECD-sensitive headspace volatile components, the content ratios of K to Ca and Mn to Fe, the NIRs pattern and the content ratio of ginsenoside-Rg to -Re may be indicators for the discrimination of ginseng habitat.

  • PDF

Comparative Analysis of the Phyto-compounds Present in the Control and Experimental Peels of Musa paradisiaca used for the Remediation of Chromium Contaminated Water

  • Kaniyappan, Vidhya;Rathinasamy, Regina Mary;Manivanan, Job Gopinath
    • Mass Spectrometry Letters
    • /
    • 제13권4호
    • /
    • pp.166-176
    • /
    • 2022
  • Banana peels are also widely used as bio-adsorbent in the removal of chemicals contaminants and heavy metals from water and soil. GC-MS plays an essential role in the phytochemical analysis and chemo taxonomic studies of medicinal plants containing biologically active components. Intrinsically, with the use of the flame ionization detector and the electron capture detector which have very high sensitivities, Gas chromatography can quantitatively determine materials present at very low concentrations and most important application is in pollution studies. In the present study banana peels were used as bio-adsorbent to remediate the heavy metal contaminated water taken from three different stations located around the industrial belts of Ranipet, Tamilnadu, India. The AAS analysis of the samples shows a decrement of chromium concentration of 98.93%, 96.16% and 96.5% in Station 1, 2 and 3 respectively which proves the efficiency of the powdered peels of Musa paradisiaca. The GC-MS analysis of the control and treated peels of Musa paradisiaca reveals the presence of phytochemicals like Acetic Acid, 1-Methylethyl Ester, DL-Glyceraldehyde Dimer, N-Hexadecanoic Acid, 3-Decyn-2-Ol, 26-Hydroxy, Cholesterol, Ergost-25-Ene-3,5,6,12-Tetrol, (3.Beta.,5.Alpha.,6.Beta.,12.Beta.)-, 1-Methylene-2b-Hydroxymethyl-3, and 3-Dimethyl-4b-(3-Methylbut-2-Enyl)-Cyclohexane in the control banana peels. The banana peels which were used for the treatment reveals the changes and alteration of the phytochemicals. It is concluded that the alteration in phytochemicals of the experimental banana peels were due to adsorption of chromium heavy metal from the sample.