Effect of Target Angle and Thickness on the Heel Effect and X-ray Intensity Characteristics for 70 kV X-ray Tube Target

  • Kim, Gyehong;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.272-276
    • /
    • 2016
  • To investigate the optimum x-ray tube design for the dental radiology, factors affecting x-ray beam characteristics such as tungsten target thickness and anode angle were evaluated. Another goal of the study was to addresses the anode heel effect and off-axis spectra for different target angles. MCNPX has been utilized to simulate the diagnostic x-ray tube with the aim of predicting optimum target angle and angular distribution of x-ray intensity around the x-ray target. For simulation of x-ray spectra, MCNPX was run in photon and electron using default values for PHYS:P and PHYS:E cards to enable full electron and photon transport. The x-ray tube consists of an evacuated 1 mm alumina envelope containing a tungsten anode embedded in a copper part. The envelope is encased in lead shield with an opening window. MCNPX simulations were run for x-ray tube potentials of 70 kV. A monoenergetic electron source at the distance of 2 cm from the anode surface was considered. The electron beam diameter was 0.3 mm striking on the focal spot. In this work, the optimum thickness of tungsten target was $3{\mu}m$ for the 70 kV electron potential. To determine the angle with the highest photon intensity per initial electron striking on the target, the x-ray intensity per initial electron was calculated for different tungsten target angles. The optimum anode angle based only on x-ray beam flatness was 35 degree. It should be mentioned that there is a considerable trade-off between anode angle which determines the focal spot size and geometric penumbra. The optimized thickness of a target material was calculated to maximize the x-ray intensity produced from a tungsten target materials for a 70 keV electron energy. Our results also showed that the anode angle has an influencing effect on heel effect and beam intensity across the beam.

Application of electron beam irradiation for studying the degradation of dye sensitized solar cells (전자선 조사를 통한 염료감응형 태양전지의 분해 연구)

  • Akhtar, M.Shaheer;Lee, Hyun-Cheol;Min, Chun-Ji;Khan, M.A.;Kim, Ki-Ju;Yang, O-Bong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.179-182
    • /
    • 2006
  • The effect of electron beam irradiation on dye sensitized solar cell (DSSC) has been studied to examine degradation of DSSC. The high-energy electron beam irradiation affects on the materials and performance of dye sensitized solar cells. We have checked the effects of electron beam irradiation of $TiO_2$ substrate with and without dye adsorption on the photovoltaic performances of resulting DSSCS and also studied the structural and electrical properties of polymers after irradiation. All solar cells materials were irradiated by electron beams with an energy source of 2MeV at different dose rates of 60 kGy, 120 kGy 240 kGy and 900 kGy and then their photoelectrical parameters were measured at 1 sun $(100 mW/cm^2)$. It was shown that the efficiency of DSSC was decreased as increasing the dose of e-beam irradiation due to lowering in $TiO_2$ crystallinity, decomposition of dye and oxidation of FTO glasses. On the other hand, the performance of solid-state DSSC with polyethylene oxide based electrolyte was improved after irradiation of e-beam due to enhancement of its conductivity and breakage of crosslinking.

  • PDF

Experimental Analysis on Temperature Compensation of Capacitive Voltage Divider for a Pulsed High Voltage Measurement (고전압 펄스신호 측정용 분압기의 온도보상에 관한 실험)

  • Jang, S.D.;Son, Y.G.;Kwon, S.J.;Oh, J.S.;Cho, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1530-1533
    • /
    • 2005
  • Total 12 units of high power klystron-modulator systems as microwave source is under operation for 2.5-GeV electron linear accelerator in Pohang Light Source(PLS) linac. RF power and beam power of klystron are precisely measured for the effective control of electron beam. A precise measurement and measurement equipment with good response characteristics are required for this. Input power of klystron is calculated from the applied voltage and the current on its cathode. Tiny measurement error severely effects RF output power value of klystron. Therefore, special care is needed to measure precise beam voltage. Capacitive voltage divider(CVD) unit is intended for the measurement of beam voltage of 400 kV generated from the pulsed klystron-modulator system. Main parameter to determine the standard capacitance in the high arm of CVD is dielectric constant of insulation oil. Therefore CVD should be designed to have a minimum capacitance variation due to voltage, frequency and temperature in the measurement range. This paper will discuss the analysis of capacitive voltage divider for a pulsed high-voltage measurement, and the empirical relations between capacitance and oil temperature variation.

  • PDF

Study on the Reduction of Electron Contamination with A Cobalt-60 Gamma Ray (코발트-60 감마선의 전자 오염에 관한 연구)

  • Kim, Tae-Kyu;Chun, Ha-Chung;Lee, Myung-Za
    • Radiation Oncology Journal
    • /
    • v.7 no.2
    • /
    • pp.293-297
    • /
    • 1989
  • Electron contamination due to the interaction between radiation beam and material was analyzed for the factors such as source-skin distance (SSD), field size, tray characteristics and position of filter, which can affect the surface dose in Cobalt teletherapy. Surface dose in open beam was more influenced by SSD with increasing field size. Relative surface charge (RSC) increased with the use of tray (solid, circular hole, slotted), compared with open beam, which is thought to be due to increased electron contamination of the tray. To reduce the surface dose, 0.4mm thick Lipowitz metal filter was used. Compared with open beam, RSC decreased by 8.8%, 11.3%, 13.3%, 16.6%, 19.3% and 21.7% for the field size of $5{\times}5$, $10{\times}10$, $15{\times}15$, $20{\times}20$, $25{\times}25$ and $30{\times}30cm^2$, respectively. On the contrary, use of Lipowitz metal filter increased RSC at 60cm or less SSD. Surface dose was effectively reduced with Lpowitz metal filter placed right below solid tray in Cobalt teletherapy.

  • PDF

Development of a Wide Dose-Rate Range Electron Beam Irradiation System for Pre-Clinical Studies and Multi-Purpose Applications Using a Research Linear Accelerator

  • Jang, Kyoung Won;Lee, Manwoo;Lim, Heuijin;Kang, Sang Koo;Lee, Sang Jin;Kim, Jung Kee;Moon, Young Min;Kim, Jin Young;Jeong, Dong Hyeok
    • Progress in Medical Physics
    • /
    • v.31 no.2
    • /
    • pp.9-19
    • /
    • 2020
  • Purpose: This study aims to develop a multi-purpose electron beam irradiation device for preclinical research and material testing using the research electron linear accelerator installed at the Dongnam Institute of Radiological and Medical Sciences. Methods: The fabricated irradiation device comprises a dual scattering foil and collimator. The correct scattering foil thickness, in terms of the energy loss and beam profile uniformity, was determined using Monte Carlo calculations. The ion-chamber and radiochromic films were used to determine the reference dose-rate (Gy/s) and beam profiles as functions of the source to surface distance (SSD) and pulse frequency. Results: The dose-rates for the electron beams were evaluated for the range from 59.16 Gy/s to 5.22 cGy/s at SSDs of 40-120 cm, by controlling the pulse frequency. Furthermore, uniform dose distributions in the electron fields were achieved up to approximately 10 cm in diameter. An empirical formula for the systematic dose-rate calculation for the irradiation system was established using the measured data. Conclusions: A wide dose-rate range electron beam irradiation device was successfully developed in this study. The pre-clinical studies relating to FLASH radiotherapy to the conventional level were made available. Additionally, material studies were made available using a quantified irradiation system. Future studies are required to improve the energy, dose-rate, and field uniformity of the irradiation system.

Computer Simulation for Development of Micro-Focus X-ray Generator (미소초점엑스선원 개발을 위한 전산모사)

  • Kim, Sung-Soo;Lee, Youn-Seoung;Kim, Do-Yun;Ko, Dong-Seob
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.6
    • /
    • pp.403-408
    • /
    • 2011
  • To develop the MFX (Micro-Focus X-ray) tube, the trajectories of electrons emitted from the field emission cathode was simulated using SIMION program. Regardless of starting position of the electron in emitter, we found out the fact that there is the optimum extractor voltage Ve, which can focus the electron beam on one place. Extractor voltage Ve varies depending on the source voltage Vs, but the ratio of two voltages (Ve/Vs) is always constant, its value was 99.4%. When the ratio of two voltages (Ve/Vs) was 99.4%, the beam diameter in the cross-over point was $1.2{\mu}m$. Because the focal spot size in MFXG (Micro-Focus X-ray Generator) can not be less than the cross-over diameter within MFX tube, it is important to find out the conditions that can make a smaller beam diameter. Therefore, the above results is considered to be a very important ones in the development of the MFXG.

Fininte element analysis of electron beam welding considering for moving heat source (이동 열원을 고려한 전자빔 용접의 유한요소해석)

  • Cho, Hae-Yong;Jung, Seok-Young;Kim, Myung-Han;Cho, Chang-Yong;Lee, Je-Hoon;Seo, Jung
    • Laser Solutions
    • /
    • v.4 no.1
    • /
    • pp.21-28
    • /
    • 2001
  • Simulation on the electron beam welding of Al 2219 alloy was carried out by using commercial FEM code MARC, which encounters moving heat sources. Due to axisymmetry of geometry, a half of the cylinder was simulated. A coupled thermo-mechanical analysis was carried out and subroutine for heat flux was substituted in the program. The material properties such as specific heat, heat transfer coefficient and thermal expansion coefficient were given as a function of temperature and the latent heat associated with a given temperature range is considered. As a result, the proper beam power is 60㎸${\times}$60㎃ and welding speed is 1∼1.5 m/min. The residual stress in the heat-affected zone as well as the fusion zone does not increase. It is necessary to use jigs for preventing distortion of cylinder and improving weld quality.

  • PDF

A design of transmission-type multi-target X-ray tube based on electric field modulation

  • Zhao, Lei;Jia, Wenbao;Jin, Limin;Shan, Qing;Cheng, Can;Zhu, Hongkui;Hei, Daqian
    • Nuclear Engineering and Technology
    • /
    • v.53 no.9
    • /
    • pp.3026-3034
    • /
    • 2021
  • Multi-target X-ray tube is a new type X-ray source, and can be applied in many fields such as sensitive X-ray fluorescence analysis and medical imaging. In this work, we report an electric field modulation multi-target X-ray tube, which contains four targets (Cr, Ni, Au, Mo) coated on a Beryllium (Be) window. A four-valve electric field deflector was developed to deflect the electron beam to bombard the corresponding targets. Particle dynamics analysis software was employed to simulate the particle tracking of electron beam. The results show that the 30 keV electron beam could get a 6.7 mm displacement on the target plane by 105 V/m electric field. The focus areas are about 2 mm × 5 mm and 4 mm × 2.5 mm after deflection in two directions. Thermal behavior calculated by ANSYS shows that the designed target assembly could withstand a 10 W continuous power. The optimum target thicknesses and emission spectra were obtained by Geant4 when the thickness of Be window was 300 mm and the electron beam incident angle was 0.141 rad. The results indicate that this multi-target X-ray tube could provide different X-ray sources effectively.

Calculation of the ppressure pprofile for the ppLS Vacuum System

  • C.D.ppark;Kim, H.J.;Park, W.C.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1993.07a
    • /
    • pp.39-39
    • /
    • 1993
  • A finite element analysis and Monte Carlo method have been applied to calculate the ppressure pprofiles around the ppohang Light Source (ppLS) electron storage ring with the aim of ppredicting the pperformance of the vacuum system designed for the ppLS vacuum system. After ppropperly choosing the design pparameters, the ppressure distribution are calculated as a function of the integrated stored beam current [AmppHrs]. The effect of changes of the vacuum pparameters, such as installed ppumpping sppeeds and synchrotron radiation induced gas desorpption rates on the ppressure pprofile, is also studied. The results indicate that the use of lumpped non-evapporable getter ppumpps together with spputter ion ppumpps for ppumpping the ppLS down to the required ppressure is ppossible in the ppresence of synchrotron induced gas loads, after resonable beam cleaning time.

  • PDF

Optimization for Electro Deposition Process of PC/ABS Resin Surface Treatment (수지의 하전 입자빔 전처리 공정의 최적화)

  • Park, Young Sik;Shim, Ha-Mong;Na, Myung Hwan;Song, Ho-Chun;Yoon, Sanghoo;Jang, Keun Sam
    • The Korean Journal of Applied Statistics
    • /
    • v.27 no.4
    • /
    • pp.543-552
    • /
    • 2014
  • High bandwidth RF such as Bluetooth, GPRS, EDGE, 3GSM, HSDPA is papular in the mobile phone market. A non-conducting metal coating process requires an e-beam deposition of metal, two steps of UV hard coating primer and top coating; however, it is inefficient. We navigate to the electron beam irradiation conditions(resin surface treatment conditions) in the PC/ABS resin injection process. By analyzing the experimental results, we find the optimum development conditions for the electro deposition pre-treatment process and mass production lines using the plasma generated electron beam source.