• 제목/요약/키워드: Electron accelerator

검색결과 253건 처리시간 0.025초

Micro and Nano Engineered High Volume Ultrafine Fly Ash Cement Composite with and without Additives

  • Roychand, R.;De Silva, S.;Law, D.;Setunge, S.
    • International Journal of Concrete Structures and Materials
    • /
    • 제10권1호
    • /
    • pp.113-124
    • /
    • 2016
  • This paper presents the effect of silica fume and nano silica, used individually and in combination with the set accelerator and/or hydrated lime, on the properties of class F high volume ultra fine fly ash (HV-UFFA) cement composites, replacing 80 % of cement (OPC). Compressive strength test along with thermogravimetric analysis, X-ray diffraction and scanning electron microscopy were undertaken to study the effect of various elements on the physico-chemical behaviour of the blended composites. The results show that silica fume when used in combination with the set accelerator and hydrated lime in HV-UFFA cement mortar, improves its 7 and 28 day strength by 273 and 413 %, respectively, compared to the binary blended cement fly ash mortar. On the contrary, when nano silica is used in combination with set accelerator and hydrated lime in HV-UFFA cement mortar, the disjoining pressure in conjunction with the self-desiccation effect induces high early age micro cracking, resulting in hindering the development of compressive strength. However, when nano silica is used without the additives, it improves the 7 and 28 day strengths of HV-UFFA cement mortar by 918 and 567 %, respectively and the compressive strengths are comparable to that of OPC.

Evaluation by thickness of a linear accelerator target at 6-20 MeV electron beam in MCNP6

  • Dong-Hee Han ;Kyung-Hwan Jung;Jang-Oh Kim ;Da-Eun Kwon ;Ki-Yoon Lee;Chang-Ho Lee
    • Nuclear Engineering and Technology
    • /
    • 제55권6호
    • /
    • pp.1994-1998
    • /
    • 2023
  • This study quantitatively evaluated the source term of a linear accelerator according to target thickness for a 6-20 MeV electron beam using MCNP6. The elements of the target were tungsten and copper, and a composite target and single target were simulated by setting different thickness parameters depending on energy. The accumulation of energy generated through interaction with the collided target was evaluated at 0.1-mm intervals, and F6 tally was used. The results indicated that less than 3% reference error was maintained according to the MCNP recommendations. At 6, 8, 10, 15, 18, and 20 MeV, the energy accumulation peaks identified for each target were 0.3 mm in tungsten, 1.3 mm in copper, 1.5 mm in copper, 0.5 mm in tungsten, 0.5 mm in tungsten, and 0.5 mm in tungsten. For 8 and 10 MeV in a single target consisting only of copper, the movement of electrons was confirmed at the end of the target, and the proportion of escaped electrons was 0.00011% and 0.00181%, respectively.

Energy Calibration for Neutron Capture Resonance of Natural Sm by Using 46-MeV Electron Linear Accelerator

  • Lee, Jae-Hong;Lee, Sam-Yol
    • 한국방사선학회논문지
    • /
    • 제1권2호
    • /
    • pp.31-35
    • /
    • 2007
  • Energy calibration is important to identify accurate neutron capture resonance energy in the neutron TOF (Time-of-Flight) experiment. In present study, the accurate neutron capture resonance energies of natural Sm were measured by using a 46-MeV electron linear accelerator (linac) at the Research Reactor Institute, Kyoto University(KURRI). The BGO spectrometer were adopted for measurement the prompt capture gamma-ray of the sample. To obtain energy calibration curve, resonance energy of a gold sample used as standard resonance energy Mughabghab's data (From neutron resonance parameters data). Previous data (by Mughabghab) of natural Sm sample have been compared with the present result.

  • PDF

PAL-XFEL 빔라인 허치 구조물 개발 (The Development of Beamline Hutch Structures at PAL-XFEL)

  • 김승남;김명진;김성한;김영찬;신호철;김지화;김경숙;김광우;엄인태
    • 한국소음진동공학회논문집
    • /
    • 제26권5호
    • /
    • pp.567-577
    • /
    • 2016
  • The hutches which are installed in the beamline are largely classified into two, i.e XPP (X-ray pump probe) and CXI (Coherent X-ray image). Laser room is installed on the hutch and provides laser to XPP and CXI simultaneously. And two hutches have heavy crane to install some optics equipments. Safety and reliability of hutch structures should be taken into account for the precise operating of the laser facilities, so vibration analysis is essential to do this. The main purpose of vibration analysis is to install hutch structures with large stiffness. We have changed materials specification several times to install hutch structures having strong stiffness. Now hutch structures were installed and checked vibration status at laser room and XPP hutch. The results of laser table and robot arm satisfy vibration criteria. This paper explains about the design and vibration analysis of hutch structures.

4세대방사광가속기 진공시스템 (Vacuum system for PAL-XFEL)

  • 나동현
    • 진공이야기
    • /
    • 제4권1호
    • /
    • pp.12-15
    • /
    • 2017
  • The Pohang Accelerator Laboratory X-ray Free Electron Laser (PAL-XFEL) is a 0.1 nm hard X-ray FEL which aims at providing photon flux higher than $1{\times}10^{12}$ photons/pulse using a 10-GeV electron linac. The vacuum system of the machine consists of an injector section including an S-band photocathode RF gun, 10-GeV electron linac section based on S-band normal conducting accelerating structures and a 150-m long out-vacuum undulator system. We introduce the present status of PAL-XFEL vacuum systems.

Electron Paramagnetic Resonance Study of Al-incorporated ZnO:Mn Diluted Magnetic Semiconductors

  • Park, Jun Kue;Lee, K.W.;Choi, D.M.;Lee, Cheol Eui
    • Journal of the Korean Physical Society
    • /
    • 제73권12호
    • /
    • pp.1884-1888
    • /
    • 2018
  • We have employed electron paramagnetic resonance spectroscopy and magnetization measurements in order to study the effect of Al-incorporation on the magnetic interactions in ZnO:Mn diluted magnetic semiconductors. Al-doping is shown to decrease the antiferromagnetic correlation and to increase the ferromagnetic interaction, which is attributed to the hydrogen-mediated ferromagnetic Mn complexes in our Mn-doped ZnO samples.

차세대 가속기용 공동형 빔위치 측정기 개발 (Cavity-type Beam Position Monitors for Future Accelerators)

  • 김승환;박용정;황운하;황정연
    • 한국진공학회지
    • /
    • 제15권4호
    • /
    • pp.331-337
    • /
    • 2006
  • 국제 직선형 충돌 가속기 (ILC; International Linear Collider). 자유전자 레이저 (FEL: Free Electron Laser)와 같은 차세대 가속기에 사용 할 공동형 빔위치 측정기 ( 공동형 BPM: cavity-type beam position monitor)를 일본 고에너지 연구소 (KEK; High Energy Accelerator Research Organization)와 공동으로 개발하였다. ILC 및 FEL의 운전을 위해서는 빔 기반 정렬 (beam-based alignment)과 되먹임 장치 (feedback system)가 필수적으로 요구되는데, 이를 위해서는 적절한 위치에 서브마이크론의 분해능을 지닌 빔위치 측정기를 설치하여야 한다 [1]. 공동형 BPM은 기계적인 정밀도에 매우 민감하므로 정밀한 제작과 미세한 기계적 조정을 통하여 성능을 달성하게 된다. 우리는 제작 오차를 줄이기 위하여 공진 공동, 빔 튜브, 도파관, 전기도입기 등 모든 부품을 조립 후 한꺼번에 진공 브레이징 하였다. 공동의 외주면에는 네 개의 튜닝 핀을 두어 공진주파수 및 x-y 격리도 (x-y isolation between coupled waveguide)를 미세 조정할 수 있도록 하였다. 현재 개발된 공동형 BPM 은 공진주파수는 6.422 GHz 이며, 공동 내경은 53.822 mm, 빔의 위치 측정 범위는 ${\pm}250 {\mu}m$이다. network analyzer를 관측하면서 튜닝핀을 이용하여 x-y 격리도를 -40 dB 이하로 조정할 수 있었다. 실제 KEK ATF2에서의 전자빔을 이용한 시험에서 신호의 모양, x-y 격리도, 민감도 등에서 만족한 결과를 얻었다.

Energy Spectrum Measurement of High Power and High Energy (6 and 9 MeV) Pulsed X-ray Source for Industrial Use

  • Takagi, Hiroyuki;Murata, Isao
    • Journal of Radiation Protection and Research
    • /
    • 제41권2호
    • /
    • pp.93-99
    • /
    • 2016
  • Background: Industrial X-ray CT system is normally applied to non-destructive testing (NDT) for industrial product made from metal. Furthermore there are some special CT systems, which have an ability to inspect nuclear fuel assemblies or rocket motors, using high power and high energy (more than 6 MeV) pulsed X-ray source. In these case, pulsed X-ray are produced by the electron linear accelerator, and a huge number of photons with a wide energy spectrum are produced within a very short period. Consequently, it is difficult to measure the X-ray energy spectrum for such accelerator-based X-ray sources using simple spectrometry. Due to this difficulty, unexpected images and artifacts which lead to incorrect density information and dimensions of specimens cannot be avoided in CT images. For getting highly precise CT images, it is important to know the precise energy spectrum of emitted X-rays. Materials and Methods: In order to realize it we investigated a new approach utilizing the Bayesian estimation method combined with an attenuation curve measurement using step shaped attenuation material. This method was validated by precise measurement of energy spectrum from a 1 MeV electron accelerator. In this study, to extend the applicable X-ray energy range we tried to measure energy spectra of X-ray sources from 6 and 9 MeV linear accelerators by using the recently developed method. Results and Discussion: In this study, an attenuation curves are measured by using a step-shaped attenuation materials of aluminum and steel individually, and the each X-ray spectrum is reconstructed from the measured attenuation curve by the spectrum type Bayesian estimation method. Conclusion: The obtained result shows good agreement with simulated spectra, and the presently developed technique is adaptable for high energy X-ray source more than 6 MeV.

Design of cryostat for superconducting quadrupole magnets in In-Flight fragmentation separator

  • Choi, Y.S.;Chang, H.M.;Baudouy, B.;Kim, D.G.;Kim, J.W.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제17권3호
    • /
    • pp.62-66
    • /
    • 2015
  • The cryostat is designed for the superconducting quadrupole magnets to be used in a heavy-ion accelerator facility. The main accelerator is superconducting linac, which can accelerate a $^{238}U$ beam to 200 MeV/u (Mega electron voltage per nucleon). The cryostat for the magnet employs an innovative design primarily driven by the requirement of the compactness, user-friendliness and reliability. Also, several ancillary requirements such as background field, space restriction due to the beam line and cryostat structure need technical attentions. The development of the cryostat for three quadrupole magnets in the in-flight fragmentation separator is presented in the paper. The concept of cryogenic design is reported and the amount of cryogenic load is estimated by a relevant analysis. The structure of the cryostat to endure the heavy iron yoke including three quadrupole magnets is presented. In addition, the design as well as the performance test of the support link for the cold mass is described.