• Title/Summary/Keyword: Electron Dose Rate

Search Result 130, Processing Time 0.028 seconds

Effects of Electron Beam Irradiation on Tribological and Physico-chemical Properties of Polyoxymethylene (POM-C) copolymer

  • Rahman, Md. Shahinur;Yang, Jong-Keun;Shaislamov, Ulugbek;Lyakhov, Konstantin;Kim, Min-Seok;Lee, Heon-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.153-153
    • /
    • 2016
  • Polyoxymethylene copolymer (POM-C) is an attractive and widely used engineering thermoplastic across many industrial sectors owing to outstanding physical, mechanical, self-lubricating and chemical properties. In this research work, the POM-C blocks were irradiated with 1 MeV electron beam energy in five doses (100, 200, 300, 500 and 700 KGy) in vacuum condition at room temperature. The tribological and physico-chemical properties of electron beam irradiated POM-C blocks have been analyzed using Pin on disk tribometer, Raman spectroscopy, SEM-EDS, Optical microscopy, 3D Nano surface profiler system and Contact angle analyzer. Electron beam irradiation at a dose of 100 kGy resulted in a decrease of the friction coefficient and wear loss of POM-C block due to well suited cross-linking, carbonization, free radicals formation and energetic electrons-atoms collisions (physical interaction). It also shows lowest surface roughness and highest water contact angle among all unirradiated and irradiated POM-C blocks. The irradiation doses at 200, 300, 500 and 700 kGy resulted in increase of the friction coefficient as compared to unirradiated POM-C block due to severe chain scission, chemical and physical structural degradation. The electron beam irradiation transferred the wear of unirradiated POM-C block from the abrasive wear, adhesive wear and scraping to mild scraping for the 1 MeV, 100 kGy irradiated POM-C block which is concluded from SEM-EDS and Optical microscopic observations. The degree of improvement for tribological attribute relies on the electron beam irradiation condition (energy and dose rate).

  • PDF

AN ELECTRON MICROSCOPIC STUDY ON THE EFFECTS OF IRRADIATION ON THE BUCCAL MUCOSA OF RAT (방사선조사가 백서 협점막에 미치는 영향에 관한 전자현미경적 연구)

  • Choi Syng Kyu;Lee Sang Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.17 no.1
    • /
    • pp.7-20
    • /
    • 1987
  • The author studied the acute reaction of cobalt-60 irradiation to buccal mucosa in rats and difference of the effects of single versus fractionated exposure. 195 Sprague Dowley strain rats, weighing about 120gm, were used in this experiment. 3 rats served as controls and the remaining 192 rats were divided into six groups of 32 rats each. Experimental group Ⅰ, Ⅱ, Ⅲ were received a single dose of 15Gy, 16.5Gy, 18Gy and group Ⅳ, Ⅴ, Ⅵ were received two equal sized fractionated dose of 9Gy, 9.75Gy, 10.5Gy at 4 hour intervals, respectively. The experimental groups were irradiated with cobalt-60 teletherapy unit, Picker model 4M 60 (Field size, 12x5 cm, SSD, 50㎝, Dose rate, 222cGy/min, Depth, 1㎝). The animals were sacrificed at 1, 2, 3, 6, 12 hours, 1, 3, 7 days after irradiation and the changes of the irradiated buccal mucosa were observed by electron and light microscopy. The results were as follows: 1. A single exposure was more damaging than fractionated exposure, and as the radiation dose increased, the changes of cell organelles became faster, but the healing of radiation-induced damage in fractionated exposure was faster than in single exposure. 2. The radiation-induced changes of the basal cells were the most prominent in 18Gy-single exposure group, and the least in 18Gy-fractionated exposure group. 3. Electron-microscopically, there appeared nuclear changes, swelling of mitochondria and rough endoplasmic reticulum, decrease of free ribosome, presence of vesicles, widening of intercellular space, and loss of basal lamina. The early remarkable changes were partly loss of nuclear membrane and swelling of mitochondria. 4. Light-microscopically, derangement and pyknosis of basal cells, hydropic changes of spinous cells, enlargement of granular cells, indistinctness of basement membrane, and proliferation of epithelium were observed.

  • PDF

Performing angiographic intervention with a femoral entry shield: Element analysis microscopy and hand dose reduction for interventional radiologist

  • Law, Martin;Ng, Dickon H.L.;Yoon, Do-Kun;Djeng, Shih-Kien
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1318-1322
    • /
    • 2021
  • To unveil and delineate the elements applicable to the radiation protection of a femoral entry shield, calculate its mass attenuation coefficient, and demonstrate its dose reduction efficacy for interventional radiologist performing transarterial embolization (TAE) of ruptured hepatocellular carcinoma (rHCC). The lead equivalency of the shield was firstly validated. Electron microscopy was used to confirm the femoral entry shield being lead-free and to analyze the elemental content, with which the mass attenuation coefficient of the shield was calculated. An adult phantom, irradiated at the upper abdomen to simulate the TAE of rHCC, was used together with a dosimeter attached to the palm of a hand phantom. The dose rates at the hand phantom were measured, with the rHCC clinical protocol, without and with the femoral entry shield placed over the right femoral access site of the adult phantom. Without using the shield, the average hand dose rate was measured to be 0.325 µSv/sec. While using the shield, it was determined to be 0.110 µSv/sec. There was significant 66% dose reduction to the hand dose of IRs performing angiographic intervention with the femoral entry shield.

Pathogenic and Morphologic Variation of Toxoplasma gondii by X-Ray and Neutron Flax Irradiation (X-Ray 및 Neutron 조사에 의한 Toxoplasma gondii의 병원성 및 형태학적 변화에 대하여)

  • Han, T.W.
    • Korean Journal of Veterinary Research
    • /
    • v.10 no.2
    • /
    • pp.21-51
    • /
    • 1970
  • Series of experiments were conducted to determine lethal does of X-ray and Neutron on Toxoplasma gondii. strain RH and IRI. As well morphological changes of Toxoplasma gondii irradiated or not were compared by use of electron microscope. The pathogenicity test of the irradiated and nonirradiated Toxoplasma gondii was made in mice guinea-pigs, rabbits and pigs: The letahl dose of X-ray and Neutron on RH and IRI strain and the growth rate between two strains after irradiation were shown little differences. Morphological changes were not observed until 18th passage was made. After then, the growth rate was decreased apparently, and atrophied forms were frequently observed in electron microscope. Survival time of animals inoculated with irradiated strain was longer than that of animals giving non-irradiated strain, and Toxoplasma gondii were isolated from all the dead animals. But it is of interest that pigs survived after injection of Toxoplasma gondii remained health and much attempts were failed toisolate Toxplasma gondii remained health and much attempts were slaughtered them. Animals were succumbed after injection of Toxoplasma gondii without any relationship with serum titers. (HA antibody).

  • PDF

중금속 카드뮴의 세포독성에 관한 연구

  • 정연태;박승택;문연자;한두석;소진탁
    • Toxicological Research
    • /
    • v.9 no.1
    • /
    • pp.45-60
    • /
    • 1993
  • The present study was carried out to evaluate the cytotoxicity of cadmium on cultured rat fibroblasts. The colorimetric assays of neutral red and tetrazolium MTT, the lactatedehydrogenase activity, the amounts of total protein, the rate of DNA synthesis, the amounts of unscheduled DNA synthesis, the frequency of sister chromatid exchange, the releasing rate of intracellular calcium, and light and electron microscopic studies were performed on cultured rat fibroblasts maintained in the media containing various concentrations of cadmium. The results were as follows: The neutral red(NR) and MTT values were decreased dose-dependently by cadmium, and the NR90, NR50, MTT90 and MTT50 values of cadmium were 0.2mM, 21.5mM, 1.0Mm and 60.0Mm, respectively.

  • PDF

A Study on the Preparation and Resist Characterization of the Plasma Polymerized Thin Films (플라즈마중합막의제작과레지스트 특성에 관한 연구)

  • 이덕출;박종관;한상옥;김종석;조성욱
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.5
    • /
    • pp.802-808
    • /
    • 1994
  • The purpose of this paper is to describe an application of plasma polymerized thin film as an electron beam resist. Plasma polymerized thin film was prepared using an interelectrode capacitively coupled gas-flow-type reactor, and chosen methylmethacrylate(MMA)and methylmethacrylate-tetrameth-yltin(MMA-TMT) as a monomer. This thin films were also delineated by the electron-beam apparatus with an acceleration voltage of 30kV and an expose dose ranging from 20 to 900$\mu$C/cmS02T. The delineated pattern in the resist was developed with the same reactor which is used for polymerization using an argon as etching gas. The growth rate and etching rate of the thin film is increased with increasing of discharge power. Thin films by plasma polymerization show polymerization rate of 30~45($\pm$3) A/min, and etching rate of 440($\pm$30) A/min during Ar plasma etching at discharge power of 100W. In apparently lower than that of conventional PMMA, but the plasma-etching rate of PP(MMA-TMT) was higher than that of PPMMA.

  • PDF

Evaluation of Attenuation Rate Error on Skin Dosimeter using Monte Carlo Simulation in Photon and Electron Beam Therapy (광자선 및 전자선 치료에서 피부선량계의 측정과 시뮬레이션을 이용한 감약률 오차 평가)

  • Han, Moo-Jae;Yang, Seung-Woo;Heo, Seung-Uk;Bae, Sang-Il;Moon, Young-Min;Park, Sung-Kwang;Kim, Jin-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.6
    • /
    • pp.841-848
    • /
    • 2020
  • In the field of radiation therapy using photon beams and electron beams, since each patient has a different sensitivity to radiation, skin side effects may occur even at the same dose. Therefore, if there is a risk of excessive dose to the skin, a dosimeter is attached to verify whether the correct dose is being investigated. However, since the skin dosimeter checks the attachment site visually by measuring a point dose, it is difficult to confirm an accurate dose distribution. As a result, the measurement and simulation errors of the material HgI2 in the 6 MV photon beam were 3.73% and 5.24%, respectively, at the minimum thickness of 25 ㎛, and the material PbI2 was 4.73% and 5.65%, respectively. On the other hand, as a result of the 6 MeV electron beam, the measurement and simulation errors of the material HgI2 were 1.35% and 1.12%, respectively, at a minimum thickness of 25 ㎛, and the material PbI2 showed relatively low attenuation error, 1.67% and 1.20%, respectively. Therefore, it was evaluated that the thickness of the photon beam within 25 ㎛ and the electron beam within 100 ㎛ is suitable to have a reduction rate error within 5%. This study presents a new research direction for a flexible dosimeter attached to the human body that is required in clinical practice and the construction conditions of a future skin dosimeter.

APPLICATION OF ALANINE/ESR SPECTRUM SHAPE CHANGE IN GAMMA DOSIMETRY

  • Choi, Hoon;Kim, Jeong-In;Lee, Byung-Ill;Lim, Young-Ki
    • Nuclear Engineering and Technology
    • /
    • v.42 no.3
    • /
    • pp.313-318
    • /
    • 2010
  • Alnine pellets were installed in a nuclear power plant for one or two operation cycles and measured by electron spin resonance (ESR) spectrometers for dosimetry. Dose and "x/y ratio", i.e., satellite peak over main center peak ratio, were measured for the returned alanine dosimeters from the nuclear power plant and compared to the values of reference alanine dosimeters exposed only to gamma rays. The variation of the x/y ratio change depended on the population of radicals from each radiation component with different LET. The gamma dose in a mixed radiation field was estimated by an additive gamma ray irradiation experiment and the measured dose rate at specified locations in the containment building.

Radiation-Induced Graft Copolymerization of Acrylic Acid onto Polyester

  • Chang, Hoon-Sean;Kong, Young-Kun;Lee, Chong-Kwang;Park, Jae-Ho
    • Nuclear Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.65-74
    • /
    • 1977
  • The radiation-induced graft polymerization of acrylic acid onto polyester fabric was investigated with accelerated electron beams as ratiation source at high dose rates. Homopolymerization was suppressed by addition of cations which is known as homopolymerization inhibitor, but this practical advantage was obtained at the expense of grafting efficiency. The rate of grafting (%/sec) was proportional to the 0.82th power of dose rates over the range from 1.6$\times$10$^{6}$ to 10$\times$10$^{6}$ rad/sec. The grafted polyester fabric showed considerable improvement in moisture regain and antistatic properties.

  • PDF

Decomposition of Trchloroethylene/Air Mixture by Electron Beam Irradiation in a Flow Reactor (전자빔을 이용한 흐름반응기에서의 Trichloroethylene/Air 분해)

  • ;;;Tatiana Stuchinskaya
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.1
    • /
    • pp.97-104
    • /
    • 2001
  • Decomposition of trichloroethlyene(TCE) in electron beam irradiation was examined on order to obtain information on the treatment of VOC in air. Air containing vaporized TCE has been studied in a flow reactor with different reaction environments, at various initial TCE concentration and in the presence and absence of water vapor. Maximum decomposition was observed in oxygen reaction environment and the degree of decomposition was about 99% at 20kGy for 2,000ppm initial TCE. The concentration of TCE exponentially decreased with dose in air and pure oxygen. The effect of water vapor on TCE decomposition efficiency was examined. The decomposition rate of TCE in the presence of water vapor (5,600 ppm) was approximately 10% higher than that in the absence of water vapor. Dichloroacetic acid, dichloroacethyl chloride and dichloroethyl ester acid were identified as primary products of this reaction adn were decomposed and oxidized to yield CO and $CO_2$. Perchloroethylene, hexachloroethane, chloroform and carbon tetrachloride were also observed as highly chlorinat-ed by products.

  • PDF