• Title/Summary/Keyword: Electromechanical system

Search Result 269, Processing Time 0.027 seconds

Piezoelectric Properties of PZW-PMN-PZT Ceramics for Energy Harvesting Devices (에너지하베스팅 소자용 PZW-PMN-PZT 세라믹의 압전특성)

  • Jeong, Yeong-Ho;Nam, Seok-Ho;Kim, Seung-Rae;Jung, Ju-Hyun;Yoo, Ju-Hyun;Lee, Kab-Su;Lee, Yu-Hyong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.436-438
    • /
    • 2009
  • In this study, in order to develop the composition of ceramics capable of being sintered at low temperature with high piezoelectric properties, PZW-PMN-PZT system ceramics for piezoelectric energy harvesting application were manufactured according to the amount of PZW addition. And also, their microstructural, dielectric and piezoelectric properties were investigated. At the sintering temperature of $930^{\circ}C$, a 5 mol% PZW substituted specimen showed a maximum value of density = $7.905g/cm^3$, kp = 0.585, $d_{33}$ = 351pC/N and Qm =1,254, respectively.

  • PDF

Microstructure Characteristics and Electrical Properties of Sintered $(Bi,La)_4Ti_3O_{12}$ Ferroelectric Ceramics (소결한 $(Bi,La)_4Ti_3O_{12}$ 강유전체 세라믹의 미세구조 및 전기적 특성)

  • Yoo, Hyo-Sun;Son, Yong-Ho;Ur, Soon-Chul;Ryu, Sung-Lim;Kweon, Soon-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.276-277
    • /
    • 2006
  • 1mm-thick BLT ceramics were sintered in accordance with a bulk ceramic fabrication process. AII XRD peaks detected in the sintered ceramics were indexed as the Bi-layered perovskite structure without secondary phases. Density was increased with increasing the sintering temperature up to $1050^{\circ}C$ and the maximum value was about 98% of the theoretical density. The remanent polarization (2Pr) value of BLT ceramic sintered at $1050^{\circ}C$ was approximately $6.5\;{\mu}C/cm^2$ at the applied voltage of 4.5 kV. The calculated electromechanical coupling factor ($k_t$) of it was about 5% and the mechanical quality factor (Qm) was about 2200. From these results, a BLT ceramic target for pulsed laser deposition (PLD) system was successfully fabricated.

  • PDF

Structural health monitoring of CFRPs using electrical resistance by reduced peripheral electrodes

  • Park, Young-Bin;Roh, Hyung Doh;Lee, In Yong
    • Smart Structures and Systems
    • /
    • v.28 no.6
    • /
    • pp.737-744
    • /
    • 2021
  • In this study, structural health monitoring (SHM) methods of carbon fiber reinforced plastics (CFRPs) were investigated using electrical resistance. The developed sensing technique monitored electrical resistance in accordance with the impact damage of a CFRP. The changes in electrical resistances with multiple electrode sets enabled SHM without extra sensors so that this technique can be called self-sensing. Moreover, this study proposed electrodes only at peripheral side of a structure to minimize the number of electrodes compared to those in an array which has square number of sensors as the sensing area increases. For the intensive investigation, electromechanical sensitivity in terms of electrode distance was analyzed and optimized under drop weight impact testing. Then, SHM methods with electrodes in an array and electrodes in peripheral edges were comparatively investigated. The developed methods successfully localized impact damages into 2D coordinates. Furthermore, damage severity can be shown with a damage map by calculating electrical resistance change ratio. Therefore, structural health self-sensing system using electrical resistance was successfully developed with the minimum number of electrodes.

A Study on the Electrical and Optical Characteristics of CLN-PZT Ceramics (CLN-PZT 세라믹스의 전기, 광학 특성에 관한 연구)

  • Kang, Won-Koo
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.799-801
    • /
    • 1988
  • This paper was studied on the effects of Ca-La-Nb substitution and Zr/Ti ratio variation to Pb(Zr, Ti)$O_3$ system on structural, electrical, optical and sound level characteristics in order to develope the piezoelectric and electrooptic ceramic devices. Also the specimens were prepared by the two stage sintering technique. The molecular formular was X($CaO{\cdot}1/4La_{2}O_{3}{\cdot}1/4Nb_{2}O_{5}){\cdot}(1-X)Pb(Zr_{Y}Ti_{1-Y})O_{3}$(x=100X, y=100Y), and the variation of x was $6{\sim}12$, y was 60${\sim}$49 and second stage sintering time was 20${\sim}$40 hours. The experimental results obtained from this study are as follows : 1. The density was decreased, the grain size was increased according to increase of Ca-La-Nb substitution. 2. The crystal structure was rhombohedral in composition 6/60/40, and the crystal structure was tetragonal and cubic according to increase of Ca-La-Nb substitution. 3. The Ca substitution of PZT system enhanced the sintering property. The Pb site vacancy resulting from the substitution of La-Nb increased the dielectrical constant, the piezoelectric charge constant, the dielectric loss and decreased the coercive field. 4. The resistivity of PZT system which has the P type conduction mechanism increased according to substitution of La-Nb because of the substituent acting as donor. 5. The PZT ceramics varied from ferroelectric substance according to increase of Ca-La-Nb substituent. The coercive field and saturation remanent polarization decreased, and at last straight line according to increase of La-Nb substitution. 6. The amount of Ca-La-Nb substitution to improve the light transmittance of speciment was 10 mol%, the Zr/Ti ratio was 49/51, and the second stage sintering time was 40 hours. 7. According to Ca-La-Nb substitution, the specimens was to be transparent. The 7.5/51/49 specimen was suitable for transparent sound vibrator because it had 58% light transmittance (thick 0.2[mm], wave length 700[mm]) and 48% electromechanical coupling factor.

  • PDF

Microstructure and Piezoelectric Properties in the (Na,K,Li)(Nb,Sb)$O_3$ system ((Na,K,Li)(Nb,Sb)$O_3$ 세라믹스의 압전특성과 미세조직의 변화)

  • Jeon, So-Hyun;Kim, Min-Soo;Jeong, Soon-Jong;Kim, In-Sung;Min, Bok-Ki;Song, Jae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.280-280
    • /
    • 2007
  • Lead oxide-based ferroelectrics are the most widely used materials for piezoelectric actuators, sensors and transducers due to their excellent piezoelectric properties. Considering lead toxicity, there is great interest in developing lead-free piezoelectric materials, which are biocompatible and environmentally friendlier. Recently alkali oxide materials, including sodium - potassium niobate (NKN), have been given attention in view of their ultrasonic application and also as promising candidates for piezoelectric lead-free system. However, it is difficult to sinter such NKN-based materials via conventional sintering process. In this reason, many researchers have investigated hot press, hot isostatic press or spark-plasma sintering of NKN-based ceramics. In this study, as candidates for lead-free piezoelectric materials, dense (Na,K,Li)(Nb,Sb)$O_3$ systems were developed by conventional sintering process. The microstructures and piezoelectric properties of the (Na,K,Li)(Nb,Sb)$O_3$ systems were investigated as a function of variable compositions. The excellent piezoelectric and electromechanical properties indicate that this system is potentially good candidate as lead-free material for a wide range of electro-mechanical transducer applications.

  • PDF

Implementation a of data repeating system using solar charging and develop algorithm for data repeating in the pasture (산지초지에서 한우 활동량 정보 수집을 위한 데이터 중계 알고리즘 및 시스템 구현)

  • Kim, Suc-Jun;Kim, Jong-Won;Kim, Chun-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.285-293
    • /
    • 2016
  • In the paper, we propose a data transmission repeating system that allows data transmission for the effective supervision of cows grazing in the pasture. It is normal practice to divide the pasture into different areas for the purpose of distributing the grazing. However, this makes it difficult to supply electrical power and transmit data, because some of the pastures are far away from the office used for collecting data. To solve this problem, we developed a repeating system that can allow data transmission in the pasture using a solar charging system that consists of a 60W solar panel, 12V/100A battery and 6A solar controller for the power supply and a data transmission algorithm which extends the range of data transmission when using the proposed repeating system. We verified the performance of the repeating system by checking whether the data transmission is successful or not when transmitting from various test points when there is an obstacle between the receiver and repeating system. We also verified the solar charging system by measuring the battery voltage when the system is operated continuously for 31 days and whether the system can supply sufficient power when the weather is cloudy or rainy for a few days. Finally, we verified the performance of the repeating system and data transmission algorithm by conducting experiments in a pasture.

Characteristics of Piezoelectric and dielectric of PMWN-PZT Ceramics (PMWN-PZT계 압전세라믹의 압전 및 유전특성)

  • 홍종국;이종섭;채홍인;윤만순;정수현
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.6
    • /
    • pp.455-459
    • /
    • 2001
  • In this paper, the dielectric and pizoelectric properties of 0.05Pb(M $n_{04}$ $W_{0.2}$N $b_{0.4}$) $O_3$-0.95(PbZ $r_{x}$ $Ti_{1-x}$ ) $O_3$+yN $b_2$ $O_{5}$ , are investigated as a function of the mole ratio of Zr and the amount of N $b_2$ $O_{5}$ . Also, the phase is analyzed by XRD. When the mole ratio of Zr is 0.51, the electromechanical coupling coefficient( $k_{p}$ ), relative dielectric constant ($\varepsilon$$^{T}$ $_{33}$ /$\varepsilon$$_{0}$ ), piezoelectric stain constrain ( $d_{33}$ and dielectric loss tangent show maximum, while the mechanical quality factor shows minimum value ; $k_{p}$ =56.5%, $d_{33}$ =258pC/N, $\varepsilon$$^{T}$ $_{33}$ /$\varepsilon$$_{0}$ =1170, $Q_{m}$ =1150, tan$\delta$=0.51%. At that composition, MPB which rhombohedral and tetragonal phase coexist in this ternary system is shown by the results of XRD analysis. Also, when the amount of N $b_2$ $O_{5}$ is 0.3wt%, the mechanical quality factor is increased to about 2000. The phase transition temperature of the ternary piezoelectric ceramic system showed about 35$0^{\circ}C$.TEX>.>.>.

  • PDF

The Oriental Medical Study about the Arrythmia Detected on the Radial Pulses and the Result of ECG. (촌관척(寸關尺)부의 검측한 부정맥과 Electrocardiographic 결과의 한의학적 검토)

  • Lyu, Heui-Yeong;Heo, Eun-Jung;Kim, Ji-Hyon;Yoon, Jung-Mi;Jeon, Seong-Ha
    • Journal of Oriental Neuropsychiatry
    • /
    • v.19 no.2
    • /
    • pp.165-193
    • /
    • 2008
  • Objective: The ECG which used for this paper, is analysis result from alogrisms of arrythmia, and we have studied that how we could certain Cold(寒)type or Heat(熱) type and that Deficiency(虛) type or Excess(實)type of organs from various special diseases, and we obtained like these results. Method & Conclusion: 1. we depend on our examination about Pulse(脈) because we can't discriminate arrythmia using ECG analysis instruments. 2. We obtained that Cold(寒) type diseases had wave that prolonged above normal baseline and ST wave which had downward aptitude. 3. We obtained that Heat(熱) type diseases had the fibrillation which had shortend wave that compare to normal and had downward aptitude or negative aptitude. 4. We obtained that Respiratory system (肺) diseases had wave that is within normal or is short of normal range and had much fluctuation in potential difference or trans on P wave. 5. The character of EKG which presented about diseases of gastric systems is prolonged above narmal range of wave, and the ECG had represented mixed wave with Heat(熱) type when accompany inflammatory in gastric system. 6. The wave of Blood Stasis(瘀血) type had upward aptitude of QRS wave, and the wave of anemia or blood loss type(少血) had downward aptitude of QRS wave, the wave which had both Cold(寒)) and Heat (熱) represented mixed waves. 7. The Knotted Pulse(結脈) and Intermittent Pulse(代脈)is corresponded with sinus brady cardia, and the Swift Pulsle(疾脈) is corresponded with fibrillation. 8. We pay attention to the relations of formations about pressures pulse from formations of EMD( electromechanical dissociation ). Result : From these results, we will have to study about ECG which using in tests of change of Parkinsons disease.

  • PDF

The oriental medical study about the arrythmia detected on the radial pulses and the result of ECG (촌관척(寸關尺)부의 검측한 부정맥과 electrocardiographic 결과와의 한의학적 검토)

  • Lyu, Heui-Yeong;Heo, Eun-Jung;Kim, Ji-Hyon;Yun, Jung-Mi;Jeon, Seong-Ha
    • Journal of the Korean Institute of Oriental Medical Informatics
    • /
    • v.14 no.1
    • /
    • pp.81-106
    • /
    • 2008
  • The ECG which used for this paper, is analysis result from alogrisms of arrythmia, and we have studied that how we could certain Cold(寒 )type or Heat(熱) type and that Deficiency(虛) type or Excess(實)type of organs from various special diseases, and we obtained like these results. 1. we depend on our examination about Pulse(脈) because we can't discriminate arrythmia using EKG analysis instruments. 2. We obtained that Cold(寒) type diseases had wave that prolonged above normal baseline and ST wave which had downward aptitude. 3. We obtained that Heat(熱) type diseases had the fibrillation which had shortend wave that compare to normal and had downward aptitude or negative aptitude. 4. We obtained that Respiratory system (肺) diseases had wave that is within normal or is short of normal range and had much fluctuation in potential difference or trans on P wave. 5. The character of EKG which presented about diseases of gastric systems is prolonged above narmal range of wave, and the EKG had represented mixed wave with Heat(熱) type when accompany inflammatory in gastric system. 6. The wave of Blood Stasis(瘀血) type had upward aptitude of QRS wave, and the wave of anemia or blood loss type(少血 ) had downward aptitude of QRS wave, the wave which had both Cold(寒) and Heat (熱) represented mixed waves. 7. The Knotted Pulse(結脈) and Intermittent Pulse(代脈) is corresponded with sinus brady cardia, and the Swift Pulsle(疾脈) is corresponded with fibrillation. 8. We pay attention to the relations of formations about pressures pulse from formations of EMD( electromechanical dissociation ). From these results, we will have to study about EKG which using in tests of change of Parkinsons disease.

  • PDF

Bending Mode Multilayer Actuator Using Low Temperature Sintering Piezoelectric Ceramics (저온소결 세라믹을 이용한 밴더형 적층 액츄에이터의 제작)

  • Lee, Ju-Young;Kim, Sang-Jong;Kang, Chong-Yun;Kim, Hyun-Jai;Lee, Sang-Yoel;Yoon, Seok-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.68-69
    • /
    • 2005
  • Low temperature ($\leq900^{\circ}C$) sintering piezoelectric ceramics $0.01Pb(Mg_{1/2}W_{1/2})O_3$-0.41Pb$(Ni_{1/3}Nb_{2/3})O_3-0.35PbTiO_3-0.23PbZrO_3+0.1wt%Y_2O_3+xwt%ZnO$ $(0{\leq}x{\leq}2.5)$ have been developed and investigated. The electromechanical coupling coefficient ($k_p$), piezoelectric constant ($d_{33}$), and mechanical quality factor ($Q_m$) have been measured to characterize the piezoelectric materials system. When 2.0 wt% ZnO is added, the properties of the system, $d_{33}$ = 559 pC/N, $k_p$ = 55.0 % and $Q_m$ = 73.4 are obtained which are very suitable for piezoelectric actuators. A bending mode multilayer actuator has been also developed using the materials which size is $27(L)\times9(W)\times1.07(t)mm^3$. The actuators are fabricated by multilayer ceramic (MLC) process and consist of24 layers and each layer thickness is $35{\mu}m$. At this time, the displacement of actuator was $100{\mu}m$ at 28V.

  • PDF