• 제목/요약/키워드: Electromagnetic torque

검색결과 195건 처리시간 0.02초

새로운 2상 8/6 SRM의 구조적 특성에 관한 비교 연구 (A Comparative Study on the Structural Characteristics of the Novel Two-Phase 8/6 Switched Reluctance Machine)

  • 이치우;황홍식;오석규
    • 전기학회논문지
    • /
    • 제66권2호
    • /
    • pp.315-322
    • /
    • 2017
  • This study presents a novel two­phase eight stator poles and six rotor poles (8/6) switched reluctance machine (SRM) that can compensate for the vibration and noise problems of two­phase 6/3 SRM and compare the characteristics of two SRMs. In the case of two­phase 6/3 SRM, the short flux path and the flux direction inside the stator are not reversed, so they have high efficiency characteristics. However, the use of three rotor poles causes problems of vibration and noise because the radial force applied to the rotor poles is not balance. The proposed two­phase 8/6 SRM has advantages of 6/3 SRM such as the flux­reversal­free stator and it can improve vibration and noise by using six rotor poles due to balanced radial force acting on the rotor poles. In order to make a reasonable comparison between two SRMs, the electromagnetic field structure of 8/6 SRM is designed to have equivalent torque characteristic to 6/3 SRM and then the copper loss and core loss are compared and analyzed. Finally, we compare the effieicney of two SRMs using finite element analysis and compare the distribution of radial force acting on the rotor poles based on Maxwell's stress method.

웨어러블 IT 기기에 적용 가능한 초소형 진자 발전기에 관한 연구 (A Study on the Ultra-Small Pendulum Generator Applicable to Wearable IT Device)

  • 지인호;신승중
    • 한국인터넷방송통신학회논문지
    • /
    • 제22권3호
    • /
    • pp.139-143
    • /
    • 2022
  • 본 연구에서는 전자기 유도 발전(EMG) 기법 중 RFPM의 설계사양을 설정하고 특성 계산에 필요한 유한요소해석(FEM, 2D)을 통하여 이에 적합한 시험 시제품을 제작하였다. 또한 시험용 프로토타입의 측정, 분석을 하기위하여 전용 검사장치를 설계, 제작하였다. 검사장치로 시험품을 측정하였으며, 그 결과를 분석하여 실제 인체 운동 에너지를 이용하여 웨어러블 IT 기기의 배터리에 충전이 가능한 만큼 출력전력이 생성되어 적용할 수 있는 방법을 제시하고자 한다. 시험결과, 회전수 780.9rpm, 토크 0.264kgf/cm, 부하전류 73.6~73.9mA의 조건에서 출력 1.679W, 효율 79.31%로 측정되었다. 따라서 초소형 RFPM 진자 발전기의 출력으로 웨어러블 기기에 충전이 가능한 것으로 분석되었다.

LCL 필터와 PWM 정류기를 이용한 3상 유도전동기의 시뮬레이터 (Simulator for 3 Phase Induction Motor with LCL Filter and PWM Rectifier)

  • 조관열;김학원
    • 한국산학기술학회논문지
    • /
    • 제21권11호
    • /
    • pp.861-869
    • /
    • 2020
  • 대용량 유도전동기용 인버터 개발을 위한 부하 장치는 고가의 제작 비용 및 제작에 많은 시간이 필요하므로 유도전동기 및 부하 장치를 대체할 수 있는 시뮬레이터 개발에 대한 필요가 증대되고 있다. 기존의 대용량 3상 유도전동기의 인버터용 부하 시뮬레이터는 리액터와 3상 PWM 정류기를 사용하여 시험용 인버터의 전류를 제어함으로써 단지 인버터의 부하로만 작용할 뿐 유도전동기의 특성을 모사하기 어렵다. 본 논문에서는 LCL 필터와 3상 PWM 정류기를 이용하여 3상 유도전동기의 모델과 부하 특성을 모사할 수 있는 실시간 시뮬레이터를 제안한다. PWM 인버터에 흐르는 전류는 3상 유도전동기의 고정자 전류를 모사하며 LCL 필터의 인덕터에 흐르는 전류와 커패시터 전압에 의해 제어된다. LCL 필터의 커패시터 전압은 3상 유도전동기의 회전자 자속에 의해 고정자 권선에 유기되는 유도기전력을 모사하며 인덕터 전류와 PWM 정류기에 의해 제어된다. 3상 유도전동기의 회전자 전류, 고정자 및 회전자 자속, 전동기 토크, 슬립 주파수 및 회전자 속도는 인버터에 흐르는 전류와 유도전동기의 상수로부터 유도된다. MATLAB/Simulink 시뮬레이션을 통하여 제안된 3상 유도전동기용 실시간 시뮬레이터의 전기적, 기계적 모델 특성 및 벡터제어 동작을 검증하였다.

자화침 시스템을 이용한 경락전위 유발효과 및 근피로 회복 평가 (Evaluation of Muscle Fatigue Recovery Effect and Meridian Potential Change using Magnetic Acupuncture System)

  • 김수병;박선우;안순재;이나라;이승욱;민세은;김영호;이용흠
    • Korean Journal of Acupuncture
    • /
    • 제29권1호
    • /
    • pp.83-92
    • /
    • 2012
  • Objectives : The purpose of this research was to develop the magnetic acupuncture system which used solenoid coil for magnetizing acupuncture needle. The system could generate the meridian electric potential (MEP) similar to the potential by manual acupuncture. Thus, we tried to confirm the therapeutic effect that is caused by the MEP generation. Methods : To confirm the MEP, we stimulated the magnetic acupuncture with at 2Hz, $92.7{\pm}2mT$, PEMFs (Pulsed Electro-Magnetic Fields) at ST37 and measured the evoked potential between ST36 and ST41. Also, we conducted a fatigue recovery test using isokinetic exercise in order to identify the therapeutic effect on musculoskeletal disorders. We chose LR9 as a stimulation point. To observe the state of fatigue, we measured the EMG and analyzed median frequency and peak torque for 20minutes. Results : We observed that MEP which incurred from magnetic acupuncture was higher than he reported MEP induced by manual acupuncture. Moreover, its modes were divided into two types by the direction of magnetic flux. When generating magnetic flux in the direction of acupoint, the positive peak voltage of the MEP was generated. In contrast, negative peak voltage of the MEP was generated whenever meganetic flux generated in the outward direction. As a result of fatigue recovery, the median frequency (MF) of the magnetic acupuncture group were recovered faster than that of the non-stimulation group. However, the peak torques of both groups were not restored until after 20 minutes. Conclusions : We confirmed that the magnetic acupuncture system can lead to the MEP similar to manual acupuncture. Moreover, the MEP had a therapeutic effect on the musculoskeletal disorders.

광중합 복합레진의 중합초기 동적 점탄성의 변화 (THE CHANGE OF THE INITIAL DYNAMIC VISCO-ELASTIC MODULUS OF COMPOSITE RESINS DURING LIGHT POLYMERIZATION)

  • 김민호;이인복
    • Restorative Dentistry and Endodontics
    • /
    • 제34권5호
    • /
    • pp.450-459
    • /
    • 2009
  • 본 연구의 목적은 새로 개발한 점탄성 측정기를 사용하여 수종의 광중합 복합레진의 초기 동적 점탄성 변화를측정하는 것이다. 본 연구에 사용된 점탄성 측정기는 세 부분으로 구성되었다. 첫째, 시편이 놓여지는 parallel plates; 둘째, DC 모터와 크랭크로 이루어진 회전진동전단변형 (Oscillatory shear strain)을 발생시키는 부분; 셋째, 전자기적 토크센서를 이용한 응력 측정 부분으로 구성되었다. 본 점탄성 측정기는 최대 2 Ncm의 토크를 측정할 수 있으며, 광중합기의 스위치는 컴퓨터와 연동하여 데이터 획득을 시작할 때 동시에 켜지도록 하였다. 본 연구에서는 시판 중인 6종의 광중합 복합레진 [Z-100 (Z1), Z-250 (Z2), Z-350 (Z3), DenFil (DF), Tetric Ceram (TC), Clearfil AP-X (CF)]을 사용하였다. 점탄성 측정기를 사용하여 동적 회전전단실험을 시행하였다. 직경 3 mm인 유리막대로 구성된 parallel plates 사이에 $14.2\;mm^3$의 복합레진을 적용시켰으며, 6 Hz의 진동수와 0.00579 rad의 진폭으로 변형을 가하고 발생된 응력을 측정하였다. 광중합이 시작됨과 동시에 측정이 시작되었으며, 광중합 후 10초 동안 점탄성의 변화를 관찰하였다. 각 복합레진에 대해 5 회 반복하여 측정하였고, 실험은 $25{\pm}0.5^{\circ}C$에서 진행되었다. 측정된 변형-응력 곡선으로부터 복소전단탄성계수 G*, 저장전단탄성 계수 G', 손실전단탄성 계수 G"를 구하였고 G*가 10 MPa에 이르는 시간을 구하였다. 각 재료의 복소전단탄성계수 G*와 10 MPa에 이르는 시간에 대해 일원분산분석 (One-way ANOVA)과 사후검정 (Tukey 검정)을 시행하였다 (${\alpha}$= 0.05). 결과는 다음과 같다. 1.본 연구를 위해 제작한 점탄성 측정기는 광중합 복합레진의 중합 초기 10초 동안의 동적 점탄성 변화를 신뢰성 있게 측정 할 수 있었다. 2. 모든 복합레진은 광조사 개시 후 $1{\sim}2$초의 불응기를 지난 다음 급격한 전단탄성계수의 증가를 보였다. 3. 모든 복합레진은 광중합 10 초간 손실전단탄성계수보다 저장전단탄성계수의 높은 증가를 보였다. 4. 광중합 초기 10초 후 복소전단탄성계수 값은 $150.3{\sim}563.7\;MPa$로, Z-100이 가장 높았고, 그 다음 Clearfil, Z-250, Z-350, Tetric Ceram, DenFil의 순이었다. 5. 복소전단탄성계수가 10 MPa에 이르는 시간은 Z-100이 2.55초로 가장 빨랐고, DenFil이 4.06초로 가장 느렸다.