• Title/Summary/Keyword: Electromagnetic pressure

Search Result 209, Processing Time 0.025 seconds

Magnetorheological Elastomer Based on Reactive Blend of Maleic Anhydride Grafted Chloroprene Rubber and Epoxidized Natural Rubber (말레무수물로 개질된 클로로프렌 고무와 에폭시화 천연고무의 반응 블렌드에 기초한 자기유변 탄성체)

  • Choi, Jinyoung;Chung, Kyungho
    • Elastomers and Composites
    • /
    • v.49 no.4
    • /
    • pp.267-274
    • /
    • 2014
  • Self vulcanizable blend system for magnetorheological elastomer (MRE) has been studied by dispersing magneto responsible particle (MRP) on elastomeric matrix. Chloroprene rubber was modified with maleic anhydride (MAH) using heat and pressure which is called dynamic maleation process. The optimum graft ratio of MAH was found at 10 phr contents and reaction temperature of $100^{\circ}C$. This could be confirmed by FT-IR analysis. Epoxided natural rubber (ENR) was blended with modified CR-g-MAH for self vulcanization. The optimum amounts of ENR was 30 wt% in terms of scorch time and curing rate. MRE was manufactured by electromagnetic equipment and orientation of MRE was confirmed by SEM. Finally, it was found that the tensile strength of anisotropic-MRE was higher than that of isotropic-MRE and the hardness was reverse.

A Inclined Slot-excited Circular Plasma Source with a Cusp Magnetic Field

  • You, H.J.;Kim, D.W.;Koo, M.;Jang, S.W.;Jung, Y.H.;Lee, B.J.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.435-435
    • /
    • 2010
  • A inclined slot-excited plasma source is newly designed and constructed for higher flux HNB(Hyperthermal Neutral Beam) generation. The present source is different from the vertical SLAN(SLot ANtenna) sources [1] in two aspects. One is that the slots are inclined, and the other is that the magnetic field is configured to a cusp type. These modifications are intended to make the source plasma operated in sub-milli-torr pressure regime and as thin as possible, both of which is to get higher HNB flux by decreasing the re-ionization rate of the reflected atoms from the neutralizer [2]. The plasma is generated in a quartz tube of internal diameter 170 mm enclosed in a aluminum application chamber of larger diameter 250 mm. The microwave power is fed to the plasma chamber by 8 inclined slots cut into the application chamber wall. The slots are coupled the chamber to a WR280 waveguide wound around it to form a ring resonator. In order to make two slots $\lambda_g/2$ apart in phase, the adjacent slots are rotated in opposite directions. The rotation angle of the slots are set to $60^{\circ}$ from the chamber axis. Between the quartz chamber and the aluminum cylindrical chamber 8 NdFeB magnets are equally spaced and fixed to form the cusp magnetic field confinement and ECR (Electron Cyclotron Resonance) field. In this presentation, the magnetic and electromagnetic simulations, and the measured plasma parameters are given for both the inclined and the vertical slot-excited plasma sources. We also discuss how the sources can be tailored to suit better-performing HNB sources.

  • PDF

Design of Polymer Composites for Effective Shockwave Attenuation (충격파 완화 복합재의 설계)

  • Gyeongmin Park;Seungrae Cho;Hyejin Kim;Jaejun Lee
    • Composites Research
    • /
    • v.37 no.1
    • /
    • pp.21-31
    • /
    • 2024
  • This review paper investigates the use of shockwave attenuating materials within composite structures to enhance personnel protection against blast-induced traumatic brain injury (bTBI). This paper also introduces experimental methodologies exploited in the generation and measurement of shockwaves to evaluate the performance of the shock dissipating composites. The generation of shockwaves is elucidated through diverse approaches such as high-energy explosives, shock tubes, lasers, and laser-flyer techniques. Evaluation of shockwave propagation and attenuation involves the utilization of cutting-edge techniques, including piezoelectric, interferometer, electromagnetic induction, and streak camera methods. This paper investigates phase-separated materials, including polyurea and ionic liquids, and provides insight into composite structures in the quest for shockwave pressure attenuation. By synthesizing and analyzing the findings from these experimental approaches, this review aims to contribute valuable insights to the advancement of protective measures against blast-induced traumatic brain injuries.

Effects of Head-down Tilt $(-6^{\circ})$ on Peripheral Blood Flow in Dogs (두부하위$(-6^{\circ})$로의 체위변동이 말초혈류에 미치는 영향)

  • Chae, E-Up;Yang, Seon-Young;Bae, Jae-Hoon;Song, Dae-Kyu
    • The Korean Journal of Physiology
    • /
    • v.24 no.1
    • /
    • pp.51-65
    • /
    • 1990
  • The purpose of the present study was to examine the hemodynamic responses, especially in arterial and skin blood flows, in conjunction with the changes of plasma catecholamine levels as an indirect marker of adrenergic tone during the early stage of head-down tilt (HDT), and to evaluate the early physiological regulatory mechanism in simulated weightlessness. Ten mongrel dogs, weighing8\;{\sim}\;14\;kg, were intravenously anesthetized with nembutal, and postural changes were performed by using the tilting table. The postural changes were performed in the following order: supine, prone, HDT $(-6^{\circ}C)$ and lastly recovery prone position. The duration of each position was 30 minutes. The measurements were made before, during and after each postural change. The arterial blood flow $({\.{Q}})$ at the left common carotid and right brachial arteries was measured by the electromagnetic flowmeter. Blood pressure (BP) was directly measured by pressure transducer in the left brachial artery. To evaluate the peripheral blood flow, skin blood flow $({\.{Q}})$ was calculated by the percent changes of photoelectric pulse amplitude on the forepaw, and skin temperature was recorded. The peripheral vascular resistance (PR) was calculated by dividing respective mean BP values by ${\.{Q}}$ of both sides of common carotid and brachial arteries. Heart rate (HR), respiratory rate (f) and PH, $Po_{2},\;Pco_{2}$ and hematocrit of arterial and venous blood were also measured. The concentration of plasma epinephrine and norepinephrine was measured by radioenzymatic method. The results are summarized as follows: Tilting to head-down position from prone position, HR was initially increased (p<0.05) and BP was not significantly changed. While ${\.{Q}}$ of the common carotid artery was decreased (p<0.05) and PR through the head was increased, ${\.{Q}}$ of the brachial artery was increased (p<0.05) and PR through forelimbs was decreased. ${\.{Q}}$ of the forepaw was initially increased (p<0.05) and then slightly decreased, on the whole revealing an increasing trend. Plasma norepinephrine was slightly decreased and the epinephrine was slightly increased. f was increased and arterial pH was increased (p<0.05). In conclusion, the central blood pooling during HDT shows an increased HR via Bainbridge reflex and an increased ${\.{Q}}$ of the forepaw and brachial ${\.{Q}}$, due to decreased PR which may be originated from the depressor reflex of cardiopulmonary baroreceptors. It is suggested that the blood flow to the brain was adequately regulated throughout HDT $(-6^{\circ}C)$ in spite of central blood pooling. And it is apparent that the changes of plasma norepinephrine level are inversely proportional to those of ${\.{Q}}$ of the forepaw, and the changes of epinephrine level are paralleled with those of the brachial ${\.{Q}}$.

  • PDF

Power Generation Performance Evaluation according to the Vehicle Running on the Hybrid Energy Harvesting Block (하이브리드 에너지하베스팅 블록의 차량주행 발전성능 평가)

  • Kim, Hyo-Jin;Park, Ji-Young;Jin, Kyu-Nam;Noh, Myung-Hyun
    • Land and Housing Review
    • /
    • v.7 no.4
    • /
    • pp.307-314
    • /
    • 2016
  • Energy harvesting technique is to utilize energy that is always present but wasted. In this study, we have developed the energy harvester of the hybrid method utilizing both vibration and pressure of the vehicle traveling a road or parking lot. In the previous study, we have developed a prototype energy harvester, improved hybrid energy harvester, and developed a final product that offers improved performance in the hybrid module. The results were published in the previous paper. In this study, we installed the finally developed hybrid module in the actual parking lot. And we measured the power generation performance due to pressure and vibration, and the running speed of the vehicle when the vehicle is traveling. And we compared the results with those obtained in laboratory conditions. In a previous study performed in laboratory conditions the maximum power of the energy block was 1.066W when one single time of vibration, and 1.830W when succession with 5 times. On the other hand, in this study, we obtained the average power output of 0.310W when the vehicle is running at an average 5 km/h, 0.670W when at an average 10 km/h, and 1.250W when at an average 20 km/h, and 2.160W when at an average 5 km/h. That is, the higher the running speed of the vehicle has increased power generation performance. However, when compared to laboratory conditions, the power generation performance of the energy block in driving speed by 20km/h was lower than those in laboratory conditions. In addition, when compared to one time of vibration of laboratory conditions, power generation performance was higher when the running speed 20km/h or more and when five consecutive times in laboratory conditions, it was higher when the running speed 30km/h or more. It could be caused by a difference of load conditions between the laboratory and the actual vehicle. Thus, applying the energy block on the road would be more effective than that on the parking lot.

Changes of Minute Blood Flow in the Large Vessels during Orthostasis and Antiorthostasis, before and after Atropine Administration (체위변화가 두부 및 하지의 분시혈류량에 미치는 영향)

  • Park, Won-Kyun;Chae, E-Up
    • The Korean Journal of Physiology
    • /
    • v.19 no.2
    • /
    • pp.139-153
    • /
    • 1985
  • The passive tilt has been performed to study the orthostasis on the cardiovascular system. The orthostasis due to upright tilt was demonstrated as follows: the venous return, cardiac output and systemic arteiral blood pressure were decreased, whereas there was concomitant increase of heart rate, through the negative feedback mediated by such as the baroreceptor . Previous investigators have suggested that the tolerance to the orthostasis could he increased by blocking the cholinergic fiber with atropine which prevented vasodilation and bradycardia through the vasovagal reflex during the orthostasis. However, this hypothesis has not been clearly understood. This study was attempted to clarify the effect of atropine on the tolerance of the cardiovascular system to the upright and head-down tilt, and to investigate the change of the blood flow through head and lower leg with Electromagnetic flowmeter in both tilts before and after atropine state. Fourteen anesthetized dogs of $10{\sim}14kg$ were examined by tilting from supine position to $+77^{\circ}$ upright position (orthostasis), and then to $-90^{\circ}$ head-down position (antiorthostasis) for 10 minutes on each test. And the same course was taken 20 minutes after intravenous administration of 0.5mg atropine. The measurements were made of the blood flow(ml/min.) on the carotid artery, external jugular vein, femoral artery and femoral vein. At the same time pH, $PCO_2$, $PO_2$ and hematocrit (Hct) of the arterial and venous blood, and heart rate(HR) and respiratory rate (RR) were measured. The measurements obtained from upright and head-down tilt were compared with those from supine position. The results obtained are as follows: In upright tilt, the blood flow both on the artery and the vein through head and lower leg were decreased, however the decrement of blood flow through the head was greater than the lower leg And the atropine attenuated the decrement of the blood flow on the carotid artery, but not on the vessels of the lower leg. HR was moderately increased in upright tilt, but slightly in head-down tilt. The percent change of HR after the atropine administration was smaller than that before the atropine state in both upright and head-down tilts. Before the atropine state, RR was decreased in upright tilt, whereas increased in head-down tilt. However after the atropine state, the percent change of RR was smaller than that of before the atropine state in both upright and head-down tilts. In upright tilt, venous $PCO_2$ was increased, but arterial $PO_2$ and venous $PO_2$ were slightly decreased. Hct was increased in both upright and head-down tilts. The findings of blood $PCO_2$, $PO_2$ and Hct were not interferred by the atropine. In conclusion, 1;he administration of atropine is somewhat effective on improving the cardiovascular tolerance to postural changes. Thus, atropine attenuates the severe diminution of the blood flow to the head during orthostasis, and also reduces the changes of HR and RR in both orthostasis and antiorthostasis.

  • PDF

Effects of Head-Down Tilt$(-6^{\circ})$ on Hemodynamics and Plasma Catecholamine Levels (도립$(-6^{\circ})$이 혈장 Catecholamine 및 심장혈관계에 미치는 영향)

  • Song, Dae-Kyu;Bae, Jae-Hoon;Park, Won-Kyun;Chae, E-Up
    • The Korean Journal of Physiology
    • /
    • v.21 no.2
    • /
    • pp.211-223
    • /
    • 1987
  • Head-down tilt (HDT) at $-6^{\circ}$ has been commonly used as the experimental model in both man and animals to induce the blood shift toward the head or central protion of the body, demonstrating similar physiological effect encountered in the weightlessness in the orbital flight. There are few reports about the physiological response upon the cardiovascular regulatory system or the tolerance to the $(-6^{\circ})$ HDT within a relatively short period less than 1 hour. Therefore, the purpose of this study way to observe the effects of $-6^{\circ}$ HDT on cardiovascular system within 30 minutes and to evaluate early regulatory mechanism for simulated hypogravity. Ten mongrel dogs weighing 8-12 kg were anesthetized with the infusion of 1% ${\alpha}-chloralose$ (100 mg/kg) intravenously, and the postural changes were performed from the supine to the $-6^{\circ}$ head-down Position, then from the head-down to the supine (SUP), and each posture was maintained for 30 minutes. Blood flow $({\dot{Q}})$ through common carotid and femoral arteries were determined by the electromagnetic flowmeter. Mean arterial pressure (MAP), heart rate (HR), respiratory rate , and pH, $P_{O_2}$, $P_{CO_2}$ and hematocrit (Hct) of arterial and venous blood were also measured. The peripheral vascular resistance was calculated by dividing respective MAP values by ${\dot{Q}}$ through both sides of common carotid or femoral arteries. The concentration of plasma epinephrine and norepinephrine was determined by Peuler & Johnson's radioenzymatic method. The results are summarized as follows: In the initial 5 minutes in $-6^{\circ}$ HDT, HR was significantly (p<0.05) increased and MAP slightly decreased. Although ${\dot{Q}}$ and carotid peripheral artery resistance were not significantly changed, ${\dot{Q}}$ through femoral artery was diminished and femoral peripheral artery resistance was elevated. In the SUP, the initial changes of MAP and HR were increased (p<0.05), but those of ${\dot{Q}}$ and peripheral vascular resistance through both common carotid and femoral arteries were not significant. After 10 minutes of each postural change in both HDT and SUP, MAP was maintained almost equal to that of the level of pretilting control. During 60 minutes of both postural changes of HDT and SUP, $P_{O_2}$ and Hct were not changed significantly. However pH tended to increase slowly and $P_{CO_2}$ was gradually decreased. The pH and $P_{CO_2}$ seemed to be related to the increased respiratory rate. Plasma epinephrine concentration was not changed significantly and plasma norepinephrine concentration was slightly decreased in the course of HDT and also at 10 minutes of SUP. However these concentration changes were statistically insignificant. From these results, it may be concluded that the effect of $-6^{\circ}$ HDT for 30 minutes on the cardiovascular system and plasma catecholamine levels of the dog is minimum and it is suggestive that the cardiovascular regulatory mechanism, possibly mediated by so called gravity receptors including baroreceptor and volume receptor, has been properly and adequately operated.

  • PDF

Blockade of Thromboxane Influences Does Not Affect Renal Blood Flow Deficit in Anesthetized Diabetic Rats (마취된 당뇨 흰쥐의 신혈류량 감소에 관여하는 기전 : 내인성 쓰롬복산계의 무관성)

  • Ha, Hun-Joo;Dunham, Earl W.
    • The Korean Journal of Pharmacology
    • /
    • v.24 no.2
    • /
    • pp.221-232
    • /
    • 1988
  • Studies were conducted to determine whether reduced renal blood flow (RBF) exhibited by rats with uncontrolled, streptozotocin (STZ)-induced diabetes is attributable to diabetes-associated, enhanced renal vasoconstrictor influence of endogenous thromboxane $(TX)A_2$. Rats which were injected with STZ after pretreatment with 3-O-methyl glucose (3OMG), an agent which prevents STZ-induced hyperglycemia, were also studied. Basal values of total RBF (RBF; ml $min^{-1}$ $gKw^{-1}$; electromagnetic flow probe), systemic arterial pressure (BP; mm Hg) and renal vascular resistance (RVR;BP $RBF^{-1})$in pentobarbital-anesthetized rats during a control period were $5.9{\pm}0.3$(P<0.1_{VS}. CR), $115{\pm}3$ and $20.3{\pm}1.0$(P<0.1_{VS}. CR) for STZR (n=15), and $8.4{\pm}0.4$, $123{\pm}3$ and $15.1{\pm}0.8$ for age-matched control rats (CR; n= 15), respectively. Basal values of RBF, BP and RVR in 3OMG pretreated STZR were identical to CR. In preparations shown capable of renal vasodilatation, OKY 1581 (1 mg/kg, i.v. followed by 0.4 mg/kg min infusion) abolished arachidonate-induced $(TX)A_2$ synthesis, but did not alter basal BP, RBF or RVR in either STZR or CR (n=4/group). Similarly, i.r.a. infusion of SQ29548 (100 ng/ml RBF) abolished renal vasoconstriction induced by a TX/prostaglandin endoperoxide mimic, U46619, but had no discern able affect on RVR in either STZR (n=8) or CR (n=8). The data indicates that $TXA_2$ does not participate in the elevated basal RVR of STZR which are associated with the diabetic state.

  • PDF

A Study on the Application Direction of Finite Element Analysis in the Field of Packaging through Research Trend Analysis in Korea (국내 연구 동향 분석을 통한 포장분야에서 유한요소해석의 적용 방향에 관한 고찰)

  • Lee, Hakrae;Jeon, Kyubae;Ko, Euisuk;Shim, Woncheol;Kang, Wookgun;Kim, Jaineung
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.23 no.3
    • /
    • pp.191-200
    • /
    • 2017
  • Proper packaging design can meet both the environmental and economic aspects of packaging materials by reducing the use of packaging materials, waste generation, material costs, and logistics costs. Finite element analysis(FEM) is used as a useful tool in various fields such as structural analysis, heat transfer, fluid motion, and electromagnetic field, but its application in the field of packaging is still insufficient. Therefore, the application of FEM to the field of packaging can save the cost and time in the future research because it is possible to design the package by computer simulation, and it is possible to reduce the packaging waste and logistics cost through proper packaging design. Therefore, this study investigated the FEM papers published in Korea for the purpose of helping research design using FEM program in the field of packaging in the future. In this paper, we analyzed the 29 papers that were directly related to the analysis of FEM papers published in domestic journals from 1991 to 2017. As a result, we analyzed the research topic, FEM program, and analysis method using each paper, and presented the direction that can be applied in future packaging field. When the FEM is applied to the packaging field, it is possible to change the structure and reduce the thickness through the stress and vibration analysis applied to the packaging material, thereby reducing the cost by improving the mechanical strength and reducing the amount of the packaging material. Therefore, in the field of packaging research in the future, if the FEM is performed together, economical and reasonable packaging design will be possible.