• Title/Summary/Keyword: Electromagnetic Field (EMF)

Search Result 102, Processing Time 0.025 seconds

Three Axis Isotropic Field Strength Measuring Antenna (3축 등방성 전계강도 측정 안테나)

  • Choi, Suk-Hwan;Kim, Dong-Seok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.9
    • /
    • pp.879-885
    • /
    • 2014
  • In this paper, we designed and fabricated wideband 3-axis isotropic antenna for the Electro-Magnetic Fields(EMFs) measurement. Each part of proposed 3-axis antenna has isotropic characteristics and arbitrary axis of proposed 3-axis antenna could be selectable using RF switch. Also, a resistor was inserted in each axis of proposed 3-axis antenna for improving antenna gain and noise suppression characteristics, and port impedance of each dipole antenna were matched by balun. For the performance verification of antenna, GTEM Cell which generates standard electromagnetic field was used for the derivation of antenna factor and receiver sensitivity. As a result, fabricated 3-axis isotropic antenna has receiver sensitivity of 0.12~4.2 mV/m and typical VSWR of 3.3:1 within a wide operation frequency range from 0.03 MHz to 3 GHz.

Analysis and Design of high-efficiency Permanent Magnet Synchronous Motor/Generator for Renewable Energy Application (신재생 에너지 적용을 위한 고효율 영구자석 동기 전동/발전기의 해석 및 설계)

  • You, Dae-Joon;Kim, Il-Jung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.5
    • /
    • pp.955-964
    • /
    • 2011
  • In renewable energy system such as flywheel energy storage system, wind power and solar power, the motor/generator is the important key for offering the electric energy to the electric loads. For example, the heavy and large flywheel is rotated by electromagnetic torque of pemanent magnet synchronous motor (PMSM) and, in case of a breakdown of electric current, the PMSM used as generator supplies electric energy for the various electric utilities using mechanical rotation energy of the flywheel. Thus, design of a motor/generator should be performed in effort to reduce cogging torque and electromagnetic loss for high efficiency. In our paper, a slotless permanent magnet synchronous motor/generator (SPMSM/G) with output power 15kW at the rotor speed 18000rpm is designed from electromagnetic analysis and dynamic performance analysis. In analytical approach, design parameters such as back electro-motive force (back EMF), inductance and electromagnetic torque are derived from analytical method which is one of the electromagnetic analysis method. And using the design parameters, this paper deal with system design considering the driving characteristics and electric load in required power. Finally, the analytical results are verified by the experiment and finite element method (FEM).

Analysis of Worker Exposure Space according to Distribution of Electromagnetic Field of Generator (발전기의 전자기장 분포 특성에 따른 작업자 노출공간 분석)

  • Seong, Minyoung;Kim, Doo-Hyun;Kim, Seungtae
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.4
    • /
    • pp.20-28
    • /
    • 2021
  • With an increase in the commercialization of electricity, and the development of advanced and large electric devices and various wireless radio wave services, concerns over the effects of electromagnetic fields on human health have increased. Accordingly, the World Health Organization encouraged the development of international standards by establishing the 'International Electromagnetic Fields Project' in 1996 based on studies on the harmful effects of electromagnetic fields on the human body. Moreover, the National Institute of Environmental Health Sciences (NIEHS) classified electromagnetic fields as possible carcinogens under Group 2B category, even though they have been found to have a weak correlation with those effects on human health. Mid-to-large-sized electric facilities used at industrial sites mostly adopt a commercial frequency of 60 Hz, and workers handling these facilities are exposed to such extremely low frequency (ELF) fields for a long time. A previous study suggested that exposure to ELF electromagnetic fields with frequency ranges from 0 to 300 Hz, even for a short time, at densities higher than 100 μT may have harmful effects on human body as it affects the activation of nerve cells in the central nervous system by inducing an electric field and current and stimulating muscles and the nervous system in the body. Such studies, however, focused on home appliances used by ordinary people, and research on facilities utilizing high-capacity current and operated by workers at industrial sites is lacking. Therefore, in this study, a 3000 kilowatt generator, which is a high-capacity electric facility employed at industrial sites, was investigated, and the size of the magnetic fields generated during its no-load and high-load operations per distance to produce a map was measured to reveal spots deemed hazardous according to domestic and international exposure standards. The findings of this study is expected to alleviate workers' anxiety about the harmful effects of magnetic fields on their body and to minimize the level of exposure during operations.

Human Exposures to Various Electromagnetic Forces : Measurement of Electromagnetic Force for Future Epidemiological Study (각종 전자파에 의한 인체의 노출 : 역학조사를 위한 전자파 측정)

  • Kim, Deok-Won;Ryu, Chang-Yong;Yoon, Hyung-Ro
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.191-200
    • /
    • 1995
  • Although air, water, and noise pollutions have been widely recognized, electromagnetic forces (EMF) hazard has been rarely recognized as a pollution and very little studies has been done in this country. Thus, in this study electromagnetic forces radiated by various home appliances, office machines, and communication equipments were measured and so were several places radiating strong EMF such as subway stations and electric substations. Among the home appliances microwave oven radiates lots of magnetic field and microwaves, and electric mattress does strong magnetic field. In video game room strong magnetic and considerable electric fields were measured. It was observed strong magnetic field inside of electric powered train and very strong magnetic and electric fields on some platforms. Hand-phone and car-phone radiate very hazardous level of microwaves to brain and that they rapidly come into wide use. In this study data base for various electric machines and places radiating strong EMFs were constructed and could be used for future epidemiological studies.

  • PDF

Implementation of SAR Measurement System with Stationary Probes (Probe 고정형 SAR 측정 시스템)

  • Kim, Jeong-Ho;Gimm, Youn-Myoung
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2005.11a
    • /
    • pp.443-447
    • /
    • 2005
  • The SAR measurement system with stationary probes, presented in this paper, can calculate area SAR value based ell the measured 9 electric field data. By converting obtained area SAR to the volume SAR, the results can be acquired in a few seconds. The system can be very useful tool in the stages of handset development for mobile communication as well as in the handset production line because of its rapid SAR measurement. The system showed good linearity characteristics at 835 MHz of 10 $\sim$ 27 dBm input power range.

  • PDF

Experimental Verification of Induction Phenomenon on Telecommunication Lines by Applying Its Occurrence Mechanisms Using an Artificial ELF Source Generator

  • Lee, Sang-Mu;Gimm, Yoon-Myoung;Eun, Chang-Soo
    • Journal of electromagnetic engineering and science
    • /
    • v.10 no.4
    • /
    • pp.276-281
    • /
    • 2010
  • In this paper, an electromagnetic induction on a telecommunication line by the distribution line of a power provision system or a feeder line of an electrified railway system has been verified through experiments. The basic cause of induction occurrence by these practical power provision systems is the returning current through the earth. This principle has been confirmed by the experiments documented in this paper which implemented these mechanisms to incur an induction. Experimental methods were used to produce the returning current through the earth. The experiment to find a relationship between inducing strength and the distance between the two phase lines in a power provision line has also been included to confirm that, when the distance is enlarged, the induction effect increases as the cross-nullification effect of magnetic fluxes decreases. An experiment for the existence of a shielding effect by another conduction length material has been addedas a protection measure against the induction.

Effect of Ginseng on Calretinin Expression in Mouse Hippocampus Following Exposure to 835 MHz Radiofrequency

  • Aryal, Bijay;Maskey, Dhiraj;Kim, Myeung-Ju;Yang, Jae-Won;Kim, Hyung-Gun
    • Journal of Ginseng Research
    • /
    • v.35 no.2
    • /
    • pp.138-148
    • /
    • 2011
  • Exponential rise in the use of mobile communication devices has generated health concerns due to radiofrequency (RF) exposure due to its close proximity to the head. Calcium binding proteins like calretinin regulate the levels of calcium ($Ca^{2+}$) which plays an important role in biological systems. Ginseng is known for maintaining equilibrium in the human body and may play a beneficial radioprotectant role against electromagnetic field (EMF) exposure. In the present study, we evaluated the radioprotective effects of red ginseng (RG) extract in a mouse model. Calretinin (CR) expression was measured using a free-floating immunohistochemical method in the hippocampus of mice after 835 MHz EMF exposure for 5 h/d for 5 d at specific absorption rate=1.6 W/kg for the different experimental groups. The control animals were treated with NaCl while the experimental animals received 10 mg/kg ginseng, or 30 mg/kg; EMF exposed mice were also treated with NaCl, 10 mg/kg ginseng (E10), or 30 mg/kg (E30). Decreases in CR immunoreactivity (IR) along with loss of CA1 and CA3 interneurons and infragranular cells were observed in the ENaCl group while such losses were not observed in the E10 and E30 groups. CR IR significantly increased in the RG-treated group compared to control and EMF-exposed groups treated with NaCl. The study demonstrates that RG extract can serve as a radioprotective agent that maintains $Ca^{2+}$ homeostasis and prevents neuronal loss in the brain hippocampal region caused by RF exposure.

Electromagnetic field analysis and performance characteristics of PMSM/G with Halbach magnetized array rotor (Halbach 자화 배열 회전자를 갖는 영구자석 동기 전동발전기의 전자기적 해석 및 성능 특성)

  • Jang, Seok-Myeong;You, Dae-Joon;Ko, Kyoung-Jin;Choi, Sang-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2008.04c
    • /
    • pp.86-88
    • /
    • 2008
  • The rotational loss is one of the most important problems for the practical use of the high power Flywheel Energy Storage System (FESS). This rotational loss is divided as the mechanical loss by windage and bearing and iron loss by hysteresis loop and eddy current in the part of the magnetic field. So, In this paper, a double-sided PMSM/G without the iron loss is designed by analytical method of the magnetic field and estimation of the back-EMF constant represented as the design parameter. This design model consists of the double-sided PM rotor with Halbach magnetized any and coreless 3-phase winding stator. The results show that the double-sided PMSM/G without iron loss can be applicable to the high power FESS.

  • PDF

Quasi-3D analysis of Axial Flux Permanent Magnet Rotating Machines using Space Harmonic Methods (공간고조파법을 이용한 축 자속 영구자석 회전기기의 준(準)-3D 특성 해석)

  • Choi, Jang-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.5
    • /
    • pp.942-948
    • /
    • 2011
  • This paper deals with characteristic analysis of axial flux permanent magnet (AFPM) machines with axially magnetized PM rotor using quasi-3-D analysis modeling. On the basis of magnetic vector potential and a two-dimensional (2-D) polar-coordinate system, the magnetic field solutions due to various PM rotors are obtained. In particular, 3-D problem, that is, the reduction of magnetic fields near outer and inner radius of the PM is solved by introducing a special function for radial position. And then, the analytical solutions for back-emf and torque are also derived from magnetic field solutions. The predictions are shown in good agreement with those obtained from 3-D finite element analyses (FEA). Finally, it can be judged that analytical solutions for electromagnetic quantities presented in this paper are very useful for the AFPM machines in terms of following items : initial design, sensitivity analysis with design parameters, and estimation of control parameters.

Estimation of Output Voltage and Magnetic Flux Density for a Wireless Charging System with Different Magnetic Core Properties

  • Park, Ji Hea;Kim, Sang Woo
    • Journal of Magnetics
    • /
    • v.18 no.2
    • /
    • pp.105-110
    • /
    • 2013
  • The design model and key parameters of the material design for the control of induced magnetic flux at the near-field and efficient power transfer in a modified wireless power transfer (WPT) system with a large air gap of wireless electric vehicles were investigated through analytical simulations for magnetic vector and time-domain transient analysis. Higher saturation magnetic core with low core loss induced a stronger vertical magnetic field by the W-type primary coil in the WPT system with a gap of 20 cm at 20 kHz, which is shown from the vector potentials of the magnetic induction. The transient analysis shows that the higher magnetic fluxes through the pick-up cores lead to a linear increment of the alternating voltage with a sinusoidal waveform in the non-contact energy transfer system.