• Title/Summary/Keyword: Electromagnetic Field (EMF)

Search Result 102, Processing Time 0.025 seconds

Analysis and Comparison of a Permanent-Magnet DC Motor with a Field-Winding DC Motor

  • Kiyoumarsi, Arash
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.3
    • /
    • pp.370-376
    • /
    • 2009
  • The influence of magnetic saturation on electromagnetic field distribution in both a permanent-magnet direct-current (PMDC) motor and a field-winding (wound-field) direct-current (FWDC) motor, with the same output mechanical power, has been studied. In this paper, an approximate analytical method and time-stepping Finite Element Method (FEM) are used for prediction of Back-EMF and electromagnetic torque. No-load and rotor-lucked conditions, according to experimental measurements, and the FEM and analytical method studies of the motors have been considered. A sensitivity analysis has also been successfully accomplished on the major design parameters that affect motor performance. At last, these two DC motors are compared, in spite of their differences, on the basis of measured output characteristics.

An Analysis of FCCL Shielding Effect for EMF Attenuation to On-Line Electric Vehicle (On-Line Electric Vehicle의 EMF 저감을 위한 FCCL 차폐효과 분석)

  • Shim, Hyung-Wook;Kim, Jong-Woo;Cho, Dong-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.6
    • /
    • pp.770-775
    • /
    • 2014
  • According to ICNIRP guidelines for limiting exposure to time-varying electric, magnetic and electromagnetic fields up to 300GHz, magnetic flux density which range from 3Hz to 150kHz are regulated to lower than $6.25{\mu}T$. In order to comply with its standard, OLEV(On-Line Electric Vehicle) have been designed considering EMF(Electro-Magnetic Field) reduction. However, if a current flowing in power line would be bigger for increasing power transfer efficiency, the established shield system no longer acts their role properly. In this paper, therefore, FCCL(Flexible Copper Clad Laminate) is applied to power line and pick-up devices to solve the problems. Though, the FCCL is normally utilized to insulator on circuit board, because of its high heat resistance characteristic, flexibility and thin properties, it makes effectiveness in the shielding device as well. 4 types of FCCL shielding structure are introduced to power line and pick-up devices. From the results, the FCCL which are placed in proposed positions shows maximum EMF reduction compared to the established shielding structure. Henceforth, if OLEV is applied FCCL shielding structure in practice, it will not only be more safe but also step forward to commercialization near future.

Assessment of subjective symptoms by 60Hz magnetic field in electromagnetic hypersensitivity (60Hz 자기장에 대한 과민 증후군의 자각증상 원인 평가)

  • Yang, Dong-In;Nam, Ki-Chang;Kwon, Min-Kyung;Kim, Deok-Won
    • Science of Emotion and Sensibility
    • /
    • v.13 no.4
    • /
    • pp.721-732
    • /
    • 2010
  • As increasing of electrical device usage, social concerns about the possible effects of 60Hz electromagnetic fields (EMF) on human health have increased. The number of people with self-attributed electromagnetic hypersensitivity (EHS) who complain of subjective symptoms such as headache, insomnia etc. also increased. However, we don't know whether the EHS results from psychological factor or real perception to the electromagnetic field. In this study, we simultaneously investigated physiological changes(heart rate, respiration rate, heart rate variability, alpha and beta waves in EEG), subjective symptoms and perception accuracy to assess origins of subjective symptoms according to the EMF exposure. Experiment consists of real and sham sessions and 60Hz 12.5uT magnetic field was on(real) or off(sham) to 15 EHS and 16 nonEHS. As the results, EMF exposure did not have any effects on physiological parameters or subjective symptoms for both groups. There was also no evidence that EHS group perceived the EMFs correctly than the control group. Therefore, the origins of subjective symptoms is not the 60Hz magnetic field but psychological factors.

  • PDF

Biological Effects of Static Magnetic Fields and ELF-Electromagnetic Field on Microcirculation in Animals

  • Ohkubo, Chiyoji;Okano, Hidyuki;Xu, Shenzhi;Gmitrov, Jraj
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 1999.07a
    • /
    • pp.117-129
    • /
    • 1999
  • Acute effects of locally applied of static magnetic field (SMF) and extremely low frequency electromagnetic field(ELF-EMF) to the cutaneous tissue within a rabbit ear chamber (REC)were evaluated under conscious conditions. Rabbits with the REC were subjected to intravital microscopical investigation by use of microphotoelectric plethysmography(MPPG). There was no dose-response relationship between the extent of vasomotion changes and frequencies(0,20,50, 100Hz)or power levels (1, 5, 10, 25, 50, 100, 200 mT). Under low vascular tone the both fields induce vasodilatation. The effects of SMF (1 mT) on the cutaneous microcirculatory system induced the vasodilatation with enhanced vasomotion under nor-adrenaline-induced high vascular tone as well as the vasoconstriction with reduced vasomotion under acetylcholine-induced low vascular tone. This suggests that the SMF can modulate vascular tone due to the modification of vasomotion biphasically in the cutaneous tissue.

  • PDF

Efficiency and EMF Safety Analysis of Wireless Power Transfer System Using Standard Human Model (표준화된 인체모델을 이용한 공진형 무선전력전송 시스템의 효율 변화 및 인체 안전성 분석)

  • Shin, Hansu;Byun, Jin-Kyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.11
    • /
    • pp.96-103
    • /
    • 2013
  • In this paper, resonant wireless power transfer systems are designed with double loop resonant coils for the resonant frequency of 150kHz. The transfer efficiency characteristics is analyzed according to the coil size, and the distance and misalignment between the coils. Then the change in efficiency is investigated when a human model is located between the resonant coils using the homogeneous human phantom of IEC-62311 standard. Also, in order to assess the safety of the wireless power transfer system, the induced current density inside the human model is calculated when it is exposed to the magnetic field of a plane wave and resonant coil. Then, the results are compared with the exposure limits in the EMF (electromagnetic field) safety guidelines.

Preliminary Results of Thermal Effects due to Mobile Phones

  • Sik, Yoo-Done
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.471-473
    • /
    • 2002
  • Public concerns associated with the electromagnetic field (EMF) exposures from mobile phones on human body are increased. Although studies on the effects of the EMF exposures on human have been carried out for a long time, it is not proved yet whether the EMF effect is harmful or not. Based on the scientific results by experts, EMF exposure limits have been regulated as a precautionary approach on the assumption that the EMF effect may be harmful. It is well known that absorbed EMF can be transformed into heat within biological tissues and that thermal effects are related with the specific absorption rate (SAR) distribution. However, the relative magnitude and distribution of the energies are not well defined. Although there is comprehensive information of the thermal effects, most of them come from animal and in vitro studies. Considerable efforts have been made to analyze the EMF absorption model while the actual temperature in the human body has been rarely measured. Temperature changes on the face of a healthy male volunteer were studied. A digital mobile phone of 1.8GHz was used. A digital infrared imaging system (IRIS-5000, Medicore, Seoul, Korea) was applied to take infrared pictures of the face every minute while the volunteer talked over the mobile phone for 20 minutes. The specification of the imaging system was as follows: Temperature resolution = 0.1$^{\circ}C$; Range of temperature measurement = 17~40$^{\circ}C$; Pixel size = 0.9mm ${\times}$ 0.9mm; Frame time = 2.6s; Active temperature of detector = 77$^{\circ}$K. The result showed that temperature of the ear region was increased during the phone call and the region of the temperature increase on the face was expanded as the phone call time increased. Further study is necessary to investigate the temperature rise analytically and quantitatively.

  • PDF

A study on the Electromagnetic Environment for the Navigation Device and Propulsion Device in Ship (선내 항해통신장비 및 추진장비에 대한 전자파환경 연구)

  • Cho, Hyung-Rae;Choi, Gi-Do;Kim, Jong-Woo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.15 no.1
    • /
    • pp.87-94
    • /
    • 2016
  • Although studies and investments on electro-magnetic fields in terrestrial areas are being conducted, they are not applied to a ship. Especially ship is consist of Top Side, Bridge, and Engine Room. Top Side is mounted Antenna and radar. Bridge is mounted navigation and navigation equipment that have a safe voyage. Finally, Engine Room is mounted switchboard and this is used to ship propulsion system. Therefore the purpose of this paper is for suggesting optimized standard to apply to marine environment through analyzing electromagnetic wave environment in ship. For this, we were measured EMF in Hanbada ship in Korea Maritime and Ocean University and we compared and analyzed to measured values in Korea standards and international standards. Consequently, Engine Room of ship for the identified that there are limits to apply. The proposed results of this research will be expected to utilize for establishing standard a plan for EMF in ship.

Electromagnetic Field Exposure and Male Breast Cancer Risk: A Meta-analysis of 18 Studies

  • Sun, Jing-Wen;Li, Xiao-Rong;Gao, Hong-Yu;Yin, Jie-Yun;Qin, Qin;Nie, Shao-Fa;Wei, Sheng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.1
    • /
    • pp.523-528
    • /
    • 2013
  • Background: The possibility that electromagnetic fields (EMF) exposure may increase male breast cancer risk has been discussed for a long time. However, arguments have been presented that studies limited by poor quality could have led to statistically significant results by chance or bias. Moreover, data fo the last 10 years have not been systematically summarized. Methods and Results: To confirm any possible association, a meta-analysis was performed by a systematic search strategy. Totals of 7 case-control and 11 cohort studies was identified and pooled ORs with 95% CIs were used as the principal outcome measures. Data from these studies were extracted with a standard meta-analysis procedure and grouped in relation to study design, cut-off point, exposure assessment method, adjustment and exposure model. A statistical significant increased risk of male breast cancer with EMF exposure was defined (pooled ORs = 1.32, 95% CI = 1.14-1.52, P < 0.001), and subgroup analyses also showed similar results. Conclusions: This meta-analysis suggests that EMF exposure may be associated with the increase risk of male breast cancer despite the arguments raised.

A Computational Model for a Neuronal Membrane Considering the Extremely Low Frequency and Mobile Phone Frequency Electromagnetic Field Effect (극 저주파 및 휴대전화 전자파 환경 변수를 고려한 새포막 활동 전위 모형)

  • 서영준;이은주;안재목;이용업;황태금;이재선;서정선
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.347-354
    • /
    • 2003
  • In this paper, a computational method of an action potential including the effect of extremely low frequency and mobile phone (external) electromagnetic fields is Proposed. The method is based on the Hodgkin and Huxley model, applies the effect of the electromagnetic fields on the action Potential in terms of a binding factor into the injection current of the model, and calculates the Strength-Duration curve from numerical experiments for a frequency range of electromagnetic fields. In the numerical experiments, the coupled ordinary differential equations of the action potential and the state variables are solved solf-consistently by using Runge-Kutta Fehlberg method. The range of the frequency considered is from 1Hz through 100Hz and of 900MHz, which is specific for a mobile Phone. The Strength-Duration curves resulted showed good agreements with the equation suggested by Hodgkin and Huxley.

The Effect of Extremely Low Frequency Electromagnetic Fields on the Chromosomal Instability in Bleomycin Treated Fibroblast Cells (Bleomycin이 처리된 사람 섬유아세포에서 극저주파 전자기장의 효과)

  • Cho, Yoon-Hee;Kim, Yang-Jee;Lee, Joong-Won;Kim, Gye-Eun;Chung, Hai-Won
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.4
    • /
    • pp.161-166
    • /
    • 2008
  • In order to determine the effect of extremely low frequency electromagnetic fields (ELF-EMF) on the frequency of micronuclei (MN), aneuploidy and chromosomal rearrangement induced by bleomycin (BLM) in human fibroblast cells, a 60 Hz ELF-EMF of 0.8 mT field strength was applied either alone or with ELM throughout the culture period and a micronucleus-centromere assay was performed. Our results indicate that the frequencies of MN, aneuploidy and chromosomal rearrangement induced by ELM increased in a dose-dependent manner. The exposure of cells to 0.8 mT ELF-EMF followed by ELM exposure for 3 hours led to significant increases in the frequencies of MN and aneuploidy compared to BLM treatment for 3 hours alone (p<0.05), but no significant difference was observed between field exposed and sham exposed control cells. The obtained results suggest that low density ELF-EMF could act as an enhancer of the initiation process of BLM rather than as an initiator of mutagenic effects in human fibroblast.