• 제목/요약/키워드: Electrolyte pH

검색결과 338건 처리시간 0.024초

Surface Chemical Aspects of Coagulation, Deposition, and Filtration Processes: Variation of Electrokinetic Potential at Metal Oxide-Water and Organic-Water Interfaces in the $Na^+$ and $Ca^{2+}$ Ion Solutions

  • Kim, Sung-Jae
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • 제4권3호
    • /
    • pp.173-183
    • /
    • 2000
  • This study measured the zeta potential of both latex colloidal particles with carboxylate surface groups and glass beads (collectors) with silanol surface group employing various solution with different chemical characteristics. The results have been compared with the surface chemistry theory. The zeta potential of the particle and collector increased with increasing pH up to 5.0 regardless of the solution chemistry. For a monovalent electrolyte solution(sodium chloride solution) the zeta potential steadily increased until the pH reached 9.5. In contrast, little change in zeta potential was made between 5.0 and 9.5 for a divalent electrolyte solution (sodium chloride solution) the zeta potential steadily increased until the pH reached 9.5. In contrast, little change in zeta potential was made between 5.0 and 9.5 for a divalent electrolyte solution (calcium chloride solution). In other words, the more the pH decreases, the larger the effect of neutral salts, such as NaCl and CaCl$_2$, have on the ζ-potential values. In this study, the PZPC(point of zero proton condition) of the particle and collector occurred below a pH of 3.1, H(sup)+ and OH(sup)- acted as a PDI (potential determining ion), and Na(sup)+ acted as an IDI(indifferent ion). The magnitude of the negative ζ-potential values of the particle and collector monotonically increased as the concentrations of Na(sup)+ or Ca(sup)2+([Na(sup)+] or [Ca(sup)2+]) decreased (the values of pNa or pCa increased). In the case of latex particles, the ζ-potential should aproach zero (isoelectric point; IEP) asymptotically as the pNa approaches zero, while in the case of calcium chloride electrolyte, ζ-potential reversal may be expected to occur around 3.16$\times$10(sup)-2MCaCl$_2$(pCa=1.5). pH, valance and ionic strength can be used in various ways to improve the water treatment efficiency by modifying the charge characteristics of the particle and collector. Predictive capability is far less certain when EDL(electrical double layer) repulsive forces exist between the particle and collector.

  • PDF

Parametric study for enhanced performance of Cu and Ni electrowinning

  • Kim, Joohyun;Kim, Han S.;Bae, Sungjun
    • Membrane and Water Treatment
    • /
    • 제10권3호
    • /
    • pp.201-206
    • /
    • 2019
  • In this study, we performed an electrowinning process for effective removal of metals (Cu and Ni) in solution and their recovery as solid forms. A complete removal of Cu and Ni (1,000 mg/L) was observed during four times recycling test, indicating that our electrowinning system can ensure the efficient metal removal with high stability and durability. In addition, we investigated effect of operation parameters (i.e., concentration of boric acid only for Ni, variation of pH, concentration of electrolyte ($H_2SO_4$), and cell voltage) on the efficiency of metal removal (Cu and Ni) during the electrowinning. The addition of boric acid significantly enhanced removal efficiency of Ni as the concentration of boric acid increased up to 10 g/L. Compared to negligible pH effect (pH 1, 2, and 4) on the Cu removal, we observed the increase in removal efficiency of Ni as the pH increased from 1 to 4. The electrolyte concentration did not significantly influence the removal of Cu and Ni in this study. We also obtained great removal rates of Cu and Ni at 2.5 V and 4.0 V, which were much faster than those at lower voltages. Finally, almost 99% of each Cu and Ni (1,000 mg/L) was selectively removed from the mixture of metals by adjusting pH and addition of boric acid after the completion of Cu removal. The findings in this study can provide a fundamental knowledge about effect of important parameters on the efficiency of metal recovery during the electrowinning.

음용수 중 수은 연속자동측정시스템의 개발에 관한 연구 (Fundamental Studies on the Development of On-line Monitoring of Trace Mercury in Drinking Water)

  • 장수현;김효진;김선태;김영만
    • 분석과학
    • /
    • 제12권4호
    • /
    • pp.299-305
    • /
    • 1999
  • Electrolyte as cathode glow discharge(ELCAD)는 용액 중에 포함된 미량 중금속을 연속 자동 측정하기 위한 새로운 플라스마 source로서 주로 원자방출법에 의하여 원소들을 측정한다. 그러나 수은의 경우 원자 방출법보다는 원자 흡수법을 주로 적용한다. 본 연구에서는 기존의 원자흡수분광기의 원자화부분을 ELCAD cell로 대치하여 원자흡수법에 의하여 수은을 측정하였다. 일반적으로 원자방출법에 의하여 원소들의 방출선측정시 용액의 pH가 1.0에서 가장 안정한 플라스마와 가장 큰 방출세기를 나타내었으나 수은인 경우 pH 3.0에서 가장 흡광도가 높았다. 그러나 플라스마의 안정도는 pH가 1.0 일 때가 가장 좋은 관계로 흡광도의 % RSD 값은 pH 1.5 용액에서는 0.35% 이었으며 pH 3.0인 검액에서는 3.6%를 나타내었다. 두 검액에 대해 각각 검량곡선을 작성하였을 때 모두 양호한 직선성을 보였으며, 각각의 검출 한계를 구한 결과, pH 1.5 용액은 약 40 ppb, pH 3.0 용액은 10 ppb level 이었다.

  • PDF

용액 공정으로 증착된 HfOx 감지막을 갖는 Electrolyte-Insulator-Semiconductor 소자의 두께 의존성 (Thickness Dependence of Solution Deposited HfOx Sensing Membrane for Electrolyte-Insulator-Semiconductor (EIS) Structures)

  • 이인규;조원주
    • 센서학회지
    • /
    • 제22권3호
    • /
    • pp.233-237
    • /
    • 2013
  • We fabricated electrolyte-insulator-semiconductor (EIS) devices using a solution process and measured the sensing properties of EIS devices according to the thicknesses of sensing membrane. For high pH sensitivity and better stability properties, we used $SiO_2/HfO_x$ (OH) layer as a sensing membrane. In this work, $HfO_x$ sensing membranes were deposited on 5 nm thick $SiO_2$ buffer layer by spin coater with thicknesses of 15, 31, 42, 55 nm, respectively. As a result, we founded that the thickness of $HfO_x$ sensing membrane affects to sensitivity and chemical stability of EIS device. Especially, the EIS device with 42 nm thick $HfO_x$ membrane showed superior sensing ability in terms of pH-sensitivity, linearity, hysteresis voltage and drift rate characteristics than the other devices. In conclusion, we confirmed that it is possible to improve the sensing ability and the chemical stability properties using optimized thickness of sensing membrane and proper annealing process.

백금전극(白金電極)에 의한 파라크레졸의 양극전해(陽極電解) 산화특성(酸化特性) (A Study on the Oxidation Characteristics of p-Cresol on Pt Anode)

  • 김홍수;남종우
    • 한국응용과학기술학회지
    • /
    • 제7권2호
    • /
    • pp.47-53
    • /
    • 1990
  • The electrochemical oxidation behavior of p-cresol on platinum anode had been investigated by cyclic voltammetric method for the variation of concentration, scan rate of potential, temperature and pH of electrolyte. The oxidation potential of p-cresol was dependent on the electrolyte until the pH=11.5, but in basic solution over its, it was held at o.40V(vs. SCE). A diffusion was rate determining step of oxidation as irreversible reaction by the transfer atone electron. The current of peak was proportional to concentration of p-cresol until the 0.1N and optimum concentration was found to be about 0.1N. The activation energy was calculated for 5.8kcal/mol from the plot of log $I_l$ vs. 1/T.

전기화학적 공정의 운전인자에 따른 산화제 생성과 염료 분해 특성 (Characteristic of Oxidants Production and Dye Degradation with Operation Parameters of Electrochemical Process)

  • 김동석;박영식
    • 한국환경과학회지
    • /
    • 제18권11호
    • /
    • pp.1235-1245
    • /
    • 2009
  • The purpose of this study is to investigate electro-generation of free Cl, $ClO_2$, $H_2O_2$ and $O_3$ and degradation of Rhodamine B in solution using Ru-Sn-Sb electrode. Electrolysis was performed in one-compartment reactor using a dimensionally stable anode(DSA) of Ru-Sn-Sb/Ti as the working electrode. The effect of applied current (0.5-3 A), electrolyte type (NaCl, KCl, HCl, $Na_2SO_4$ and $H_2SO_4$) and concentration (0.5-2.5 g/L), air flow rate (0-3 L/min) and solution pH (3-11) was evaluated. Experimental results showed that concentration of 4 oxidants was increased with increase of applied current, however optimum current for RhB degradation was 2 A. The generated oxidant concentration and RhB degradation of the of Cl type-electrolyte was higher than that of the sulfate type. The oxidant concentration was increased with increase of NaCl concentration and optimum NaCl dosage for RhB degradation was 1.75 g/L. Optimum air flow rate for the oxidants generation and RhB degradation was 2 L/min. $ClO_2$ and $H_2O_2$ generation was decreased with the increase of pH, whereas free Cl and $O_3$ was not affected by pH. RhB degradation was increase with the pH decrease.

Investigation of Nickel Removal from Heavy Metal Containing Industrial Wastewater by Electrocoagulation Method

  • Baybars Ali, Fil;Cansu, Elgun;Sevim Alya, Cihan;Sermin, Gunaslan;Alper Erdem, Yilmaz
    • Journal of Electrochemical Science and Technology
    • /
    • 제13권4호
    • /
    • pp.424-430
    • /
    • 2022
  • In the study, Ni2+ (nickel) removal from synthetically prepared wastewater by electrocoagulation method, which is one of the electrochemical treatment processes, was investigated and parameters such as current density, pH, mixing speed, initial Ni2+ concentration, supporting electrolyte type and concentration were determined to determine Ni2+ removal efficiencies effects were studied. Experiment conditions during 30 minutes of electrolysis; the current density was determined as 0.95 mA/cm2, the initial pH of the wastewater was 6, the mixing speed was 150 rpm, and the initial nickel concentration was 250 mg/L. The Ni2+ removal efficiency was obtained as 75.99% under the determined experimental conditions, while the energy consumption was calculated as 3.15 kW-h/m3. In the experiments, it was observed that the type and concentration of the supporting electrolyte did not have a significant effect on the Ni2+ removal efficiency. In the trials where the effect of the support electrolyte concentration was examined, the Ni2+ removal efficiency was 75.99% in the wastewater environment without the supporting electrolyte, while the Ni2+ removal efficiency was 81.55% when 7.5 mmol/L NaCl was used after the 30-minute reaction, and the energy consumption was 2.15 kW-h/m3 obtained as. As a result of the studies, it was concluded that the electrocoagulation process can be applied in the treatment of wastewater containing Ni2+.

Comparison of blood electrolyte and biochemical parameters between single infections of rotavirus and Cryptosporidium parvum in diarrheic Hanwoo calves

  • Seungmin, Ha;Seogjin, Kang;Kwang-Man, Park;Ji-Yeong, Ku;Kyoung-Seong, Choi;Jinho, Park
    • Journal of Veterinary Science
    • /
    • 제23권6호
    • /
    • pp.85.1-85.11
    • /
    • 2022
  • Background: Neonatal calf diarrhea is a major problem in the cattle industry worldwide. Rotavirus and Cryptosporidium parvum are the primary causative agents, especially during the first three weeks of the calf's life. Objectives: This study investigated the differences in acid-base, electrolytes, and biochemical parameters of diarrheic calves with infection of either rotavirus or C. parvum. Methods: A total of 61 Korean native calves (≤ 20 days old) were divided into two groups based on rotavirus or C. parvum infections: rotavirus infection (n = 44) and C. parvum infection (n = 17). The calves with at a specific blood pH range (pH 6.92-7.25) were chosen for comparison. The acid-base, electrolyte, chemistry, and serum proteins were analyzed, Further, fecal examinations were performed. Results: Compared to C. parvum-infected calves, the rotavirus-infected calves showed lower levels of total carbon dioxide, bicarbonate (HCO3-), anion gap, total protein, and albumin/globulin ratio, and significantly lower levels of potassium, globulin, and α2-globulin (p < 0.05). The C. parvum-infected calves (r = 0.749) had stronger correlations between pH and HCO3- than the rotavirus-infected calves (r = 0.598). Compared to rotavirus-infected calves, strong correlations between globulin and α2-globulin, α2-globulin and haptoglobin were identified in C. parvum-infected calves. Conclusions: This study is the first to investigate acid-base, electrolyte, and biochemical parameters in calves in response to infections of rotavirus and C. parvum. Although rotavirus and C. parvum cause malabsorptive and secretory diarrhea in similar-aged calves, blood parameters were different. This would help establish the diagnostic and treatment strategies.

케토프로펜의 경피전달 및 전기삼투압의 영향 (Transdermal Delivery of Ketoprofen and the Effect of Electroosmosis)

  • 오승열
    • Journal of Pharmaceutical Investigation
    • /
    • 제34권6호
    • /
    • pp.491-497
    • /
    • 2004
  • We investigated some important factors which affect the transdermal flux of ketoprofen, a nonsteroidal anti-inflammatory agent, as a first step to provide some basic knowledge for the development of a iontophoretic transdermal patch system. Factors such as current density, polarity, buffer (HEPES) and electrolyte concentration and pH were studied using hairless mouse skin. The effect of poly(L-lysin), which is known to affect the electro-osmotic flow through skin, on flux was also studied. Passive flux was about $20\;{\mu}g/cm^2hr$ at pH 4.0, but was negligible at pH 7.4 where all ketoprofen molecules dissolved are ionized (ketoprofen pKa=5.94). At pH 4.0, application of anodal current increased the flux further above the passive level, however anodal flux at pH 7.4 was much smaller than passive flux at pH 4.0. The application of cathodal current at pH 4.0 increased the average flux to $30-40\;{\mu}g/cm^2hr$, depending on the current density applied. At pH 7.4, cathodal flux was only about $5\;{\mu}g/cm^2hr$. Decrease in buffer and electrolyte concentration increased this cathodal flux about 10 fold. However decrease in HEPES buffer concentration 100 fold did not affect the flux. Anodal flux of acetaminophen was much larger than cathodal flux, indicating that electroosmotic flow can be playing an important role in the flux. Poly(L-lysin) increased the cathodal flux at pH 7.4. These results provide some important insights into the mechanism of transdermal flux of ketoprofen and the role of electroosmotic flow.

전철 누설전류가 지하매설 배관엘 미치는 영향 해석 (Analysis of DC Traction Stray Current Influences on Buried Pipelines)

  • 이현구;하태현;배정효;하윤철;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1273-1275
    • /
    • 2003
  • Corrosion of metallic structures arises when an electric current flows from the metal into the electrolyte such as soil and water. The potential difference across the metal-electrolyte interface, the driving force for the corrosion current, can emerge due to a variety of temperature, pH, humidity etc.. In this paper we analyze P/S potential and axial current of the pipeline with CP systems using BEM and DC traction stray current influences on buried pipelines.

  • PDF