• Title/Summary/Keyword: Electrohydrodynamic(EHD) flow

Search Result 14, Processing Time 0.024 seconds

NUMERICAL MODELING OF WIRE ELECTROHYDRODYNAMIC FLOW IN A WIRE-PLATE ESP

  • Chun, Young-Nam
    • Environmental Engineering Research
    • /
    • v.11 no.3
    • /
    • pp.164-171
    • /
    • 2006
  • Numerical modeling of the flow velocity fields for the near corona wire electrohydrodynamic (EHD) flow was conducted. The steady, two-dimensional momentum equations have been computed for a wire-plate type electrostatic precipitator (ESP). The equations were solved in the conservative finite-difference form on a fine uniform rectilinear grid of sufficient resolution to accurately capture the momentum boundary layers. The numerical procedure for the differential equations was used by SIMPLEST algorithm. The Phoenics (Version 3.5.1) CFD code, coupled with Poisson's electric field, ion transport equations and the momentum equation with electric body force were used for the numerical simulation and the Chen-Kim ${\kappa}-{\varepsilon}$ turbulent model numerical results that an EHD secondary flow was clearly visible in the downstream regions of the corona wire despite the low Reynolds number for the electrode ($Re_{cw}=12.4$). Secondary flow vortices caused by the EHD increases with increasing discharge current or EHD number, hence pressure drop of ESP increases.

Effects of Electrohydrodynamic Flow and Turbulent Diffusion on Collection Efficiency of an Electrostatic Precipitator with Cavity Walls

  • Park, Seok-Joo;Park, Young-Ok;Kim, Sang-Soo;McMurry, Peter H.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.97-103
    • /
    • 2001
  • The effects of the electrohydrodynamic (EHD) flow and turbulent diffusion on the collection efficiency of a model ESP composed of the plates with a cavity were studied through numerical computation. The electric field and ion space charge density were calculated by the Poisson equation of the electrical potential and the current continuity equation. The EHD flow field was solved by the continuity and momentum equations of the gas phase including the electrical body force induced by the movement of ions under the electric field. The RNG $k-{\varepsilon}$ model was used to analyze the turbulent flow. The particle concentration distribution was calculated from the convective diffusion equation of the particle phase. As the ion space charge increased, the particulate collection efficiency increased because the electrical potential increased over the entire domain in the ESP. The collection efficiency decreased and then increased, i.e. had a minimum value, as the EHD circulating flow became stronger when the electrical migration velocity of the charged particle was low. However, the collection efficiency decreased with the stronger EHD flow when the electrical migration of the particle was higher relatively. The collection efficiency of the model ESP increased as the turbulent diffusivity of the particle increased when the electrical migration velocity of the particle was low. However, the collection efficiency decreased for increasing the turbulent diffusivity when the electrical migration of the particle was higher relatively.

  • PDF

Asymmetric Electrohydrodynamic Flow of Dielectric Liquid around Symmetric Coplanar Electrodes (대칭형상의 평판 전극 주위의 비대칭 절연유체 유동)

  • Baek, Kwang Hyun;Cho, Dong Sik;Suh, Yong Kweon
    • Journal of the Korean Society of Visualization
    • /
    • v.11 no.1
    • /
    • pp.48-52
    • /
    • 2013
  • This paper presents experimental observation of asymmetric electrohydrodynamic flow generated around a pair of symmetric coplanar electrodes. Electrodes are attached on the bottom of the cavity containing a dielectric liquid, i.e., a mixture of dodecane and 0.5% wt Span80. In the first experiment, an AC voltage of 1500 V is applied with the frequency varying in the range 10~500 hz and the left electrode being grounded. The flow patterns show that the center line of vortices is unexpectedly tilted to the left side. If the right side electrode is grounded, the center line is tilted to the right side. The magnitude of the fluid velocity shows an irregular variation with the frequency in the range 10 Hz~100 Hz, beyond which it simply decays. In the second experiment, we applied fixed AC with 1000 V and 60 Hz superposed by DC voltage varying in the range -1000 V ~ +1000 V. The center line of the flow pattern is tilted to the right side with positive DC voltage and to the left side with negative DC. We have managed to show that the flow pattern can be symmetric with a suitable combination of DC and AC, e.g., DC 850 V plus AC 1000 V with the frequency 10 Hz.

Study on Electrohydrodynamic Analysis of Cylinder Type ESP (원통형 전기집진기의 전기유체역학적 해석에 관한 연구)

  • 조용수;여석준
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.3
    • /
    • pp.243-254
    • /
    • 1996
  • The main purpose of this study is to investigate the collection efficiency characteristics of a cylindrical ESP. To do that, it is necessary to analyze the electric field, gas flow field, and mechanism of particle movement by numerical simulation based on EHD model. For a gas flow field, Navier-Stokes equation involving the electric source term was solved by SIMPLE algorithm. In case of the electric field, the current continuity and electric field equations were solved by S.O.R. method. The analysis of particle movement was performed on the basis of PSI-CELL model from the Lagrangian viewpoint. The results showed that the influence on the gas flow field by the electric field is almost negligible in a cylindrical ESP. The particle drift velocity $V_P$ toward the collection surface is increased continuously by the electrostatic force due to the rise of particle charge as the particle is moving to the flow direction and the particle size becomes larger. The collection efficiency is to quitely higher with the increase of applied voltage for the same particle size, while becomes smaller as the inlet velocity is increased.

  • PDF

Electrohydrodynamic Drop Formation Processes of a Needle-Centered Nozzle Electrode (침심 노즐전극의 전기 유체역학적 액적 형성과정)

  • Moon, Jae-Duk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1807-1811
    • /
    • 2008
  • In this paper, the meniscus formation/deformation processes and conduction characteristics of the needle-centered ceramic nozzle electrode as an effective electrohydrodynamic (EHD) flow driving mechanisms for de-ionized water and silicone oil have been investigated. Results showed that the applied high voltage affected significantly on the processes, such as the drop formation mode, the deformation mode, the dripping mode, the jet mode, and the atomization mode. There was the EHD atomization mode for the de-ionized water while it was not occurred for the silicone oil, which, however, might be due to the lower electric conductivity and dielectric property of the oil than that of the water.

Electrohydrodynamic Pumping Characteristics of the Needle-Centered Nozzle Electrode (침심 노즐전극의 전기유체역학적 펌핑 특성)

  • Jung, Hoi-Won;Moon, Jae-Duk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1812-1817
    • /
    • 2008
  • A cooling system for microelectronics is becoming more important as its surface heat density is projected to reach that of the sun surface. The existing technologies using natural and forced convection are limited to solve the problems. Recently, an electrohydrodynamic driven flow is studied as one of the means to cope with this problems. A new method, utilizing a needle-centered nozzle electrode, has been proposed and investigated. The I-V characteristics of the nozzle electrode for deionized water and silicone oil were significantly different from that of without liquid, which might be due to the liquid drop covered on the nozzle tip by the EHD force acting near the needle tip. Results showed that the liquid pumping rate and flow efficiency of the nozzle electrode were very high, especially for the silicone oil. Theoretical analysis also showed the effectiveness of the needle electrode centered in the ceramic nozzle, which, however, can be a means as a liquid pump.

Electrohydrodynamic Micropump Driven by Traveling Electric Fields

  • Park, Jin-Woo;Kim, Yong-Kweon
    • Journal of Electrical Engineering and information Science
    • /
    • v.2 no.3
    • /
    • pp.99-104
    • /
    • 1997
  • A novel driving theory on the electrohydrodynamic (EHD) pump driven by traveling electric fields without the temperature gradient is proposed. The equations of the generating pressure and the flow rate are derived. The EHD micropump is fabricated by micromachining technology and tested. The channel heights are 50$\mu\textrm{m}$, 100$\mu\textrm{m}$ and 200$\mu\textrm{m}$ are respectively an the channel width is 3 mm. The spacing and width of the electrodes are both 40$\mu\textrm{m}$. The maximum pressure is 70.3 Pa, 35.4 Pa and 17.2 pa at he frequency of 0.2Hz for each channel height (50$\mu\textrm{m}$, 100$\mu\textrm{m}$ and 200$\mu\textrm{m}$) and the maximum flow rate is 0.90x10\ulcorner ${\mu}$$\ell$/min, 1.88x10\ulcorner ${\mu}$$\ell$/min and 4.85x10\ulcorner ${\mu}$$\ell$/min at the frequency of 0.4H for each channel height.

  • PDF

Electrohydrodynamic Analysis of Dielectric Guide Flow Due to Surface Charge Density Effects in Breakdown Region

  • Lee, Ho-Young;Kang, In Man;Lee, Se-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.647-652
    • /
    • 2015
  • A fully coupled finite element analysis (FEA) technique was developed for analyzing the discharge phenomena and dielectric liquid flow while considering surface charge density effects in dielectric flow guidance. In addition, the simulated speed of surface charge propagation was compared and verified with the experimental results shown in the literature. Recently, electrohydrodynamics (EHD) techniques have been widely applied to enhance the cooling performance of electromagnetic systems by utilizing gaseous or liquid media. The main advantage of EHD techniques is the non-contact and low-noise nature of smart control using an electric field. In some cases, flow can be achieved using only a main electric field source. The driving sources in EHD flow are ionization in the breakdown region and ionic dissociation in the sub-breakdown region. Dielectric guidance can be used to enhance the speed of discharge propagation and fluidic flow along the direction of the electric field. To analyze this EHD phenomenon, in this study, the fully coupled FEA was composed of Poisson's equation for an electric field, charge continuity equations in the form of the Nernst-Planck equation for ions, and the Navier-Stokes equation for an incompressible fluidic flow. To develop a generalized numerical technique for various EHD phenomena that considers fluidic flow effects including dielectric flow guidance, we examined the surface charge accumulation on a dielectric surface and ionization, dissociation, and recombination effects.

Visualization of the two-layered electroosmotic flow and its EHD instability in T-channels by micro PIV

  • Kang Kwan Hyoung;Shin Sang Min;Lee Sang Joon;Kang In Seok
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.75-78
    • /
    • 2003
  • An interfacial instability has recently been observed for the DC- and AC-powered electroosmotic flows of the two miscible electrolyte layers having different concentrations in microchannels. It is rather contrary to our common belief that the flow inside a microchannel is generally stable due to the dominant role of the viscous damping. In this work, we visualized the electroosmotic flow inside a T-channel to validate the numerical predictions. It is clearly shown that the strong vortices (which characterize the interface shapes) are generated at the interface of the two fluids, as was predicted in the numerical analysis.

  • PDF

Numerical Analysis of Electro-Hydrodynamic (EHD) Flows in Electrostatic Precipitators using Open Source Computational Fluid Dynamics (CFD) Solver (오픈 소스 전산 유체 역학 해석 프로그램을 이용한 전기집진기 내부 정전 유동 해석)

  • Song, Dong Keun;Hong, Won Seok;Shin, Wanho;Kim, Han Seok
    • Particle and aerosol research
    • /
    • v.9 no.2
    • /
    • pp.103-110
    • /
    • 2013
  • The electrostatic precipitator (ESP) has been used for degrading atmospheric pollutants. These devices induce the electrical forces to facilitate the removal of particulate pollutants. The ions travel from the high voltage electrode to the grounded electrode by Coulomb force induced by the electric field when a high voltage is applied between two electrodes. The ions collide with gas molecules and exchange momentum with each other thus inducing fluid motion, electrohydrodynamic (EHD) flow. In this study, for the simulation of electric field and EHD flow in ESPs, an open source EHD solver, "espFoam", has been developed using open source CFD toolbox, OpenFOAM(R) (Open Field Operation and Manipulation). The electric potential distribution and ionic space charge density distribution were obtained with the developed solver, and validated with experimental results in the literature. The comparison results showed good agreement. Turbulence model is also incorporated to simulate turbulent flow; hence the developed solver can analyze laminar and turbulent flow. In distributions of electric potential and space charge, the distributions become distorted and asymmetric as the flow velocity increases. The effect of electrical drift flow was investigated for different flow velocities and the secondary flow in a flow of low velocity is successfully predicted.