• Title/Summary/Keyword: Electrode treatment

Search Result 691, Processing Time 0.025 seconds

Preventing Method against the Occurrence of a Corona between a Dead End clamp and a Porcelain Insulator Used in 154kV Substation

  • Han, Woon-Ki;Choi, Jong-Soo;Lee, Jun;Kim, Jae-Chul
    • International Journal of Safety
    • /
    • v.6 no.2
    • /
    • pp.22-26
    • /
    • 2007
  • An episode of corona is a heterogeneity-caused electric discharge that occurs when electric fields are formed layer on layer and concentrated on an electrode. Electric wires built at the tip of 154kV private facilities use dead end clamp spawns corona from homogeneity caused by field concentration. Corona induces power loss, noise, insulator failure and more. In this research, we've studied the characteristics of coronas that take place in porcelain insulators and terminal electric wires of supporting hard wares (dead end clamp) that are set up as spares in the 154kV private facilities use hydroelectricity installations to support electric wires. Corona, which cannot be identified by regular methods, was measured utilizing UV image camera. As the result of measuring corona via UV image camera, we've confirmed that the depletion of insulators was accelerated following the wire end treatment method and validated the stress intensity of insulators at various lengths of bare wires caused by electric fields via FEMLAB. We have also proposed a new model for relieving homogeneity-caused field concentration, and after analyzing the proposed model via FEMLAB, we've confirmed that the concentration of field distribution was indeed reduced. Such results are exploited in installation of private facilities use equipments, maintenance of insulators and hard wares as well as safety enhancement, and are anticipated to be effectively utilized in corona prevention measures.

Disinfection of harmful organism for ballast water using electrolytic treatment system (전해처리를 통한 밸러스트수의 유해생물 살균처리)

  • 박상호;김인수
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.04a
    • /
    • pp.227-232
    • /
    • 2004
  • Ballast water from ship harmful microorganism sterilized use of electrolytic sterilization system. The experimental methods were use of peristaltic flow pump upward on electrode pole. Due to reaction time, HRT were unlike microorganism on flow rate. In electrolysis, dioxide iridium coated titanium(Ti/IrO$_2$) and stainless steel plate were used for anode and cathode respectively. Current density controls make use of D.C Power supply on 250V 100Amper. Experimental use of current density between 0.1 and 0.5A was able to disinfect microorganism at 5 seconds by the reaction time. This study shows that the electrolyzed water has a potential for the sterilization of ballast water.

  • PDF

Electrical characteristic of PZT thin film deposit by Rf-magnetron sputtering as Pb excess ratio of target (Sputtering법으로 성장한 PZT 박막의 Target의 Pb Excess에 따른 전기적 특성에 관한 연구)

  • Lee, Kyu-Il;Kang, Hyun-Il;Park, Young;Park, Ki-Yeub;Song, Joon-Tae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.570-573
    • /
    • 2002
  • Pb(Zr0.52Ti0.48)O3 (PZT) thin films were deposited on the Pt/Ti bottom electrode by rf magnetron sputtering method from target containing 5%, 25% and 50% Pb excess for applying ferroelectric random access memory (FRAM). PZT films were deposited at $300^{\circ}C$ and then they were crystallized by rapid thermal annealing (RTA) at $700^{\circ}C$. After RTA treatment, our results showed that all PZT films indicated perovskite polycrystalline structure with preferred orientation (110) and no pyrochlore phase was observed by X-ray diffraction (XRD) and by Scanning electron microscopy (SEM). A well-fabricated PZT film of excess Pb 25% capacitor showed a leakage current density in the order of $2.63{\times}10^{-7}A/cm^2$ at 100kV/cm, a remanent polarization of $3.385{\mu}C/cm^2$ and a coercive field of 41.32 kV/cm. The results showed that Pb excess of target affects to electrical properties of PZT thin film.

  • PDF

Operation Characteristics of the SBR Process with Electro-Flotation (EF) as Solids-liquid Separation Method (전해부상을 고액분리 방법으로 적용한 SBR 공정의 운전 특성)

  • Park, Minjeong;Choi, Younggyun
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.3
    • /
    • pp.340-344
    • /
    • 2008
  • Electro-flotation (EF) was applied to a sequencing batch reactor process (SBR) in order to enhance solids-liquid separation. Solids-liquid separation was good enough in the SBR coupled with EF (EF-SBR) and it was possible to maintain the concentration of mixed liquor suspended solids (MLSS) high in the EF-SBR. Under moderate organic loading condition (COD loading rate: 6 g/day), control SBR (C-SBR) showed similar treatment efficiencies with the EF-SBR. Under high organic loading condition (COD loading rate: 9.6 g/day), the solids-liquid separation in the C-SBR was deteriorated due to proliferation of filamentous bulking organisms at high F/M ratio. However, the EF-SBR was operated stably and with the high MLSS concentration (above 4,000 mg/L) regardless of the organic loading conditions during overall operating period leading to the satisfactory effluent quality. Gas production rate of the electrodes was gradually decreased because of anodic corrosion and scale build-up at the surface of cathode. However it could be partially overcome by use of corrosion-proof electrode material (SUS-316 L) and by periodic current switching between the electrodes.

Leakage Current Mechanism of Thin-Film Diode for Active-Matrix Liquid Crystal Displays

  • Lee, Myung-Jae;Chung, Kwan-Soo;Kim, Dong-Sik
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.6 no.3
    • /
    • pp.126-132
    • /
    • 2002
  • The origin of image-sticking in metal-insulator-metal type thin-film diode liquid crystal displays(TFD-LCDs) is the asymmetric current-voltage(I-V) characteristic of TFD element. We developed that TFD-LCDs have reduced-image-sticking. Tantalum pentoxide(Ta$_2$O$\sub$5/) is a candidate for use in metal-insulator-metal(MIM) capacitors in switching devices for active-matrix liquid crystal displays(AM-LCDs). High quality Ta$_2$O$\sub$5/ thin films have been obtained from anodizing method. We fabricated a TFD element using Ta$_2$O$\sub$5/ films which had perfect current-voltage symmetry characteristics. We applied novel process technologies which were postannealed whole TFD element instead of conventional annealing to the fabrication. One-Time Post-Annealing(OPTA) heat treatment process was introduced to reduce the asymmetry and shift of the I-V characteristics, respectively. OPTA means that the whole layers of lower metal, insulator, and upper metal are annealed at one time. Futhermore, in this paper, we discussed the effects of top-electrode metals and annealing conditions.

  • PDF

The Influence of the Application of NEES to GV20 and L14, on HSP27 and HSP70, after the Ischemic Brain Injury

  • Choi, Jung-Hyun
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.2 no.2
    • /
    • pp.281-287
    • /
    • 2011
  • This research was attempted to seek for a positive approach within the framework of physical therapy instead of the drug treatment in the past, with regard to the ischemic brain injury in the early stage. Accordingly, the aim of this research is to observe the change of HSP27 and HSP70, the genes that are expressed in the early stage of brain injury and to investigate the effects of needle electrode electrical stimulation(NEES), upon applying NEES after ischemia. The experimental method is to give rise to global ischemia and apply NEES to 27 SD-Pat rats with the particulars of being eight-week-old, male, around 300g, and adapted to laboratory environment for more than a week, and divide them into three groups, that is, GV20 NEES group(n=9), L14 NEES group(n=9), no applied NEES global ischemia(GI) group(n=9), and then observe their changes of HSP27 and HSP70 at the time lapse of 6, 9 hr and 12 hr after ischemia, using immunohistochemistry methods. Upon observing through the immunohistochemistry method, it was noticed that there was a significant difference between the GV20 NEES group and the L14 NEES group as for HSP27 and there were significant differences among all groups as for HSP70(p<.05). Accordingly, it is supposed that the application of NEES after the outbreak of cerebral ischemia delay the apoptosis in the early ischemic part of forebrain or protect neurons against apoptosis.

Re-synthesis and Electrochemical Characteristics of LiFePO4 Cathode Materials Recycled from Scrap Electrodes

  • Kim, Hyung Sun;Shin, Eun Jung
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.3
    • /
    • pp.851-855
    • /
    • 2013
  • This paper describes an environmentally friendly process for the recovery of $LiFePO_4$ cathode materials from scrap electrodes by a simple thermal treatment method. The active materials were easily separated from the aluminum substrate foil and polymeric binders were also decomposed at different temperatures ($400^{\circ}C$, $500^{\circ}C$, $600^{\circ}C$) for 30 min under nitrogen gas flow. The samples were characterized by X-ray diffraction (XRD), scanning electronic microscopy (SEM), Raman spectroscopy, Thermogravimetric analysis (TGA), and differential scanning calorimetry (DSC). The electrochemical properties of the recycled $LiFePO_4$ cathode were evaluated by galvanostatic charge and discharge modes. The specific charge/discharge capacities of the recycled $LiFePO_4$ cathode were similar to those of the original $LiFePO_4$ cathode. The $LiFePO_4$ cathode material recovered at $500^{\circ}C$ exhibits a somewhat higher capacity than those of other recovered materials at high current rates. The recycled $LiFePO_4$ cathode also showed a good cycling performance.

Electrochemical Precipitation Treatment of Copper from an Heavymetal Wastewater (중금속폐수에서 구리의 전기화학적 침전처리)

  • 김재우;이재동;이우식;지은상
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.3
    • /
    • pp.1-6
    • /
    • 1997
  • This research was conducted in the laboratory to investigate an alternative of Copper(Cu) removal from an heavymetal wastewater using the electrochemical precipitation(ECP) process. The ECP unit consisted of an electrolytic cell made of Titanium plate and Steel plate representing anode and cathode. The DC power source applied to the ECP unit had electrical potential(E) of 50$\pm$ 1V, respectively. The synthetic wastewater used in the experiments contained Cu in the 10 mg/l concentration and the electrode separation were 2, 3, 4 cm and the initial pH were 3, 6, 9, 12, and electrolytic concentration were 0.005, 0.0125, 0.025, 0.0375 mole, and the real heavymetal wastewater used in the experiments. From the experiment for removal efficiency according to pH variation, the low pH area doesn't give the coagulation effect by Ti(OH)$_4$ because process interfere with the coagulation and oxidation reaction, therefore the optimum pH was 4-7. The removal rate was 97.75% after the lapse of 30 minutes when copper concentration and electrolytic concentration were respectively 10 mg/l and 0.025 mole. The removal rate was 96.41% after the lapse of 30minutes when the real heavymetal wastewater used. The optimum consumption of power showed 27KWh/m$^3$ when copper concentration, electrolyte concentration and cell potential were respectively 10 mg/l, 0.025 mole and 50$\pm$ 1 Volt.

  • PDF

Carbon nanotube / silane hybride film for highly efficient field emitter

  • Jeong, Hae-Deuk;Kim, Ho-Young;Jeong, Hee-Jin;Han, Joong-Tark;Lee, Geon-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.181-181
    • /
    • 2010
  • Few-walled carbon nanotubes (FWNTs)-based field emitters with long term stability are fabricated by using a spray method. Tetraethylorthosilicate (TEOS) sol as a binder was mixed with dispersed solution of FWNTs to enhance the adhesion of FWNTs on the cathode substrate. Due to the strong intermolecular interaction of TEOS to the functional groups attached on CNTs and substrate, CNTs are tightly adhered to the cathode electrode when heat treatment is performed at $150^{\circ}C$ for 1 hour, resulting in a stable electron emission of CNT emitters for long time. Excellent field emission characteristics were exhibited, with a large field enhancement factor and low turn-on voltage, comparable to those of CNT emitters fabricated by a screen printing of CNT paste. Therefore, FWNTs / TEOS hybrid films could be utilized as an alternative for the efficient and reliable field emitters.

  • PDF

Electrochemical Degradation of Phenol Using Dimensionally Stable Anode (촉매성 산화물 전극을 이용한 페놀의 전기화학적 분해)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.22 no.8
    • /
    • pp.999-1007
    • /
    • 2013
  • Electrochemical degradation of phenol was evaluated at DSA (dimensionally stable anode), JP202 (Ru, 25%; Ir, 25%; other, 50%) electrode for being a treatment method in non-biodegradable organic compounds such as phenol. Experiments were conducted to examine the effects of applied current (1.0~4.0 A), electrolyte type (NaCl, KCl, $Na_2SO_4$, $H_2SO_4$) and concentration (0.5~3.0 g/L), initial phenol concentration (12.5~100.0 mg/L) on phenol degradation and $UV_{254}$ absorbance as indirect indicator of by-product degraded phenol. It was found that phenol concentration decreased from around 50 mg/L to zero after 10 min of electrolysis with 2.5 g/L NaCl as supporting electrolyte at the current of 3.5 A. Although phenol could be completely electrochemical degraded by JP202 anode, the degradation of phenol COD was required oxidation time over 60 min due to the generation of by-products. $UV_{254}$ absorbance can see the impact of as an indirect indicator of the creation and destruction of by-product. The initial removal rate of phenol is 5.63 times faster than the initial COD removal rate.