• 제목/요약/키워드: Electrode treatment

검색결과 693건 처리시간 0.028초

중첩된 구리 판재의 전기저항가열 표면마찰 점용접(RSFSW)에 관한 연구 (A Study on Electric Resistance Heated Surface Friction Spot Welding Process of Overlapped Copper Sheets)

  • 순샤오광;진인태
    • 한국기계가공학회지
    • /
    • 제20권2호
    • /
    • pp.93-100
    • /
    • 2021
  • Copper sheets has been used widely in electric and electron industry fields because they have good electric and heat conduction property of the material. And, in order to bond copper material, a kind of soldering process is generally used. But, because it is difficult to bond by soldering between overlapped thin copper sheets, so, another kind of brazing bonding process can be used in that case. But, because the brazing process needs wide bonding area, it needs heat treatment process in electric furnace. Generally, for spot welding of sheets, a conventional electric Resistance Spot Welding process(RSW) has been used, it has welding characteristics using contact resistance heating induced by electric current flow between sheets. But, because copper sheets has the low electric resistance, it is difficult to weld by electric resistance spot welding. So, in this study, an electric Resistance heated Surface Friction Spot Welding process(RSFSW) is suggested and is testified for the spot welding ability of thin copper sheets. It is known from the experimental results and simulation that the suggested spot welding process will be able to improve the spot welding ability of copper sheets by the combined three kinds of heating generated by surface friction by rotating pin, and conducted from heated steel electrode, and generated by contact resistance of electricity.

The Effect of using Gamma Titanium RF Electrodes on the Ablation Volume during the Radiofrequency Ablation Process

  • Mohammed S. Ahmed;Mohamed Tarek El-Wakad;Mohammed A. Hassan
    • International Journal of Computer Science & Network Security
    • /
    • 제23권2호
    • /
    • pp.183-192
    • /
    • 2023
  • Radiofrequency ablation (RFA) is an alternative treatment for liver cancer to the surgical intervention preferred by surgeons. However, the main challenge remains the use of RF for the ablation of large tumours (i.e., tumours with a diameter of >3 cm). For large tumours, RFA takes a large duration in the ablation process compared with surgery, which increases patient pain. Therefore, RFA for large tumours is not preferred by surgeons. The currently materials used in RF electrodes, such as the nickeltitanium alloy (nitinol), are characterized by low thermal and electrical conductivities. On the other hand, the use of materials that have high thermal and electrical conductivities, such as titanium aluminide alloy (gamma titanium), produces more thermal energy for tumours. In this paper, we developed a cool-tip RF electrode model that uses nickel-titanium alloy and replaced it with titanium aluminide alloy by using the finite element model (FEM). The aim of this paper is to study the effect of the thermal and electrical conductivities of gamma titanium on the ablation volume. Results showed that the proposed design of the electrode increased the ablation rate by 1 cm3 /minute and 6.3 cm3/10 minutes, with a decrease in the required time ablation. Finally, the proposed model reduces the ablation time and damages healthy tissue while increasing the ablation volume from 22.5% cm3 to 62.5% cm3 in ten minutes compared to recent studies.

Synthesis and Characterization of Silver Vanadium Oxide as a Cathode for Lithium Ion Batteries

  • Nguyen, Van Hiep;Gu, Hal-Bon
    • Transactions on Electrical and Electronic Materials
    • /
    • 제17권3호
    • /
    • pp.139-142
    • /
    • 2016
  • β-AgVO3 nanorods have been successfully synthesized using a soft chemistry route followed by heat treatment. They were characterized by X-ray diffraction and field emission scanning electron microscopy, and their electrochemical properties were investigated using cyclic voltammetry, impedance spectra, and charge-discharge tests. The results showed that the smooth-surfaced nanorods are very uniform and well dispersed, with diameters of ~100-200 nm and lengths of the order of several macrometers. The nanorods deliver a maximum specific discharge capacity of 275 mAh g-1 at 30 mA g-1. They also demonstrated good rate capability with a discharge capacity at the 100th cycle of 51 mAh g-1.

Induction motors with electrostatic suspension

  • Jeon, Jong-Up;Woo, Shao-Ju;Higuchi, Toshiro
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 Proceedings of the Korea Automatic Control Conference, 11th (KACC); Pohang, Korea; 24-26 Oct. 1996
    • /
    • pp.393-396
    • /
    • 1996
  • This paper studies electrostatically suspended induction motors (ESIM). The ESIM possesses the rotating ability of an ordinary electrostatic induction motor, in addition to providing contactless support by electrostatic suspension. To accomplish these two functions, a feedback control strategy and the operating principle of an ordinary electrostatic induction motor are used. The stator possesses electrodes which exert the electrostatic forces to the rotor and are divided into a part responsible for suspension and one for rotation. Two rotor types are utilized: a polished glass disk without any surface treatment, and a polished glass disk covered with a thin layer of conductive material (ITO layer) on only one side. In this paper, the principle of the ESIM is described, followed by stator electrode design, experimental apparatus, control strategy for stable suspension. Experimental results show that the glass disk has been rotated with a speed of approximately 70 rpm while being suspended stably at a gap length of 0.3 mm.

  • PDF

Effusion Cell 방식에 의한 <111> 결정구조의 Au 박막의 제작 (Au Thin Film Fabrication of <111> Crystal Structure by Effusion Cell Process)

  • 표경수;김강대;김용규;송정근
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2004년도 하계종합학술대회 논문집(2)
    • /
    • pp.383-386
    • /
    • 2004
  • The one of important requisites for fabricating molecular electronic device is the single crystal direction of bottom substrate nowadays. [1,2]. We obtain the optimum SAM result when the Au crystal is <111> structure for Self-Assembled molecular. To get the <111> crystal Au, we generally repeat heating and cooling course after evaporating Au [3]. However, we can fabricate <111> crystal Av thin film except post treatment because we simultaneously evaporate and anneal using Effusion Cell. In this paper, we study on thin film growth of <111> crystal Au as bottom electrode which is essential for Self-Assembled molecular by Effusion Cell and analyze crystal structure, thickness, surface conductivity and so on as each process condition.

  • PDF

Low & Intermediate Level Radioactive Waste Vitrification Using Plasma Arc Melting Technology

  • Min Byeong-Yeon
    • Nuclear Engineering and Technology
    • /
    • 제35권5호
    • /
    • pp.482-496
    • /
    • 2003
  • effectiveness of the PAM graphite-electrode technology for the treatment of many types of low-level radioactive waste including : combustible material, solidified resins in cement, inorganic materials, steel, glass, and solidified boric acid cement. The objectives of PAM-200 evaluation were to verify that 1) the facility meets air emission regulations, 2) the facility can be safely operated when processing hazardous and radioactive materials and 3) satisfactory final waste forms can be produced. Results, derived from KAERI's(Korea Atomic Energy Research Institute) analyses for samples of vitrified product, scrubbing solution and offgas collected during test period, show that PAM-200 can treat radioactive wastes as well as hazardous wastes with toxic constituents and radionuclides contained in the offgas exiting from the stack to the environment controlled to be far lower than the limit regulated by air conservation law and atomic law.

Ni-MH 전지용 thin nickel foam의 제조 (Preparation of Thin Nickel Foam for Nickel-Metal Hydride Battery)

  • 신준호;김기원
    • 한국표면공학회지
    • /
    • 제28권2호
    • /
    • pp.83-91
    • /
    • 1995
  • A new method for preparation of thin nickel foam for Ni-MH battery was investigated. In this method, fine graphite powders of $1\mu\textrm{m}$$2\mu\textrm{m}$ diameter were pasted into pores of thin polyurethane foam film in order to supply electric conducting seeds for nickel deposition by electroless plating reaction. After electroless plating, remaining polyurethane foam was removed chemically by organic solvent treatment and graphite particles also removed by ultrasonic cleaning. Porosity of formed nickel foam was about 85% During electroplating, porosity of the nickel foam decreased less than 5% up to $30\mu\textrm{m}$ coating thickness. And then it was electroplated and heat-treated to improve mechanical strength and ductility. Finally, thin nickel foam for Ni electrode of Ni-MH battery with 80% porosity and $350\mu\textrm{m}$~X$400\mu\textrm{m}$ thickness was obtained.

  • PDF

Flow Injection Biosensor for the Detection of Anti-Cholinesterases

  • Chung, Myung-Sun;Lee, Yong-Tae;Lee, Hye-Sung
    • BMB Reports
    • /
    • 제31권3호
    • /
    • pp.296-302
    • /
    • 1998
  • A potentiometric flow injection biosensor for the analysis of anti-cholinesterases (anti-ChEs), based on inhibition of enzyme activity, was developed. The sensor system consists of a reactor with acetylcholinesterase (AChE) immobilized on controlled pore glass and a detector with an $H^{+}-selective$ PVC-based membrane electrode. The principle of the analysis is based on the fact that the degree of inhibition of AChE by an anti-ChE is dependent on the concentration of the anti-ChE in contact with AChE. The sensor system was optimized by changing systematically the operating parameters of the sensor to evaluate the effect of the changes on sensor response to ACh. The optimized biosensor was applied to the analysis of paraoxon, an organophosphorus pesticide. Treatment of the inhibited enzyme with pyridine-2-aldoxime fully restored the enzyme activity allowing repeated use of the sensor.

  • PDF

Cardiac pacemaker implantation 의 합병증 (Complications Following Permanent Transvenous Endocardial Pacemaker Implantation)

  • 왕영필
    • Journal of Chest Surgery
    • /
    • 제10권2호
    • /
    • pp.219-225
    • /
    • 1977
  • Pacemaker therapy has been established as a routine procedure in a variety of disturbances of :cardiac rhythm. Cardiac pacing has greatly reduced the mortality rate in patients suffering from bradyarrhythmias complicated by Stokes-Adams attacks. However, in spite of the simplicity of the treatment and reliability of the devices available today, patients and physicians alike are invovled in a multitde of pacemaker specific problems. Clinical experience with permanent transvenous pacing during a 3 year period is presented. A total of 20 pacemaker operations were performed in 13 patients. The complications in our 20 pacemaker operations were headed by skin ulceration of 3 generator pockets and early dislocation of 3 electrodes. In an additional 2 patient, stimulation of diaphragm due to a position of electrode in the coronary sinus was noticed in one and battery failure of pulse generator was detected in the other. Literatures were reviewed.

  • PDF

Clark Cell을 이용한 ppb단위 용존산소 측정기술개발 (Development of pub Level Dissolved Oxygen Measuring Technology using Clark Cell)

  • 정경열;류길수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제26권3호
    • /
    • pp.375-381
    • /
    • 2002
  • Measuring of the dissolved oxygen is widely used for the environmental control of natural waters, sewage waste treatment, medical and biochemical studies, soil husbandry, food and drug process control, and prevention of corrosion in boilers. Especially, a power plants need special management for preventing accidents from corrosion, therefore, it is essential to measure the concentration of dissolved oxygen in real-time. In this paper we present a method of measuring dissolved oxygen very accurately up to pub units. This method, called polarograph method, is based on the measures of the electric current generated by the oxidation process in cathode and de-oxidation process in anode, assuming that the amount of the current is proportional to the density of dissolved oxygen.