A Study on the Sensor Calibration of Motion Capture System using PSD Sensor to Improve the Accuracy (PSD 센서를 이용한 모션캡쳐센서의 정밀도 향상을 위한 보정에 관한 연구)

  • Choi, Hun-Il;Jo, Yong-Jun;Ryu, Young-Kee
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.583-585
    • /
    • 2004
  • In this paper we will deal with a calibration method for low cost motion capture system using psd(position sensitive detection) optical sensor. To measure the incident direction of the light from LED emitted marker, the PSD is used the output current ratio on the electrode of PSD is proportional with the incident position of the light focused by lens. In order to defect the direction of the light, the current output is converted into digital voltage value by opamp circuits peak detector and AD converter with the digital value the incident position is measured. Unfortunately, due to the non-linearly problem of the circuit poor position accuracy is shown. To overcome such problems, we compensated the non-linearly by using least-square fitting method. After compensated the non-linearly in the circuit, the system showed more enhanced position accuracy.

  • PDF

A Study of Particle-Initiated Breakdown Characteristics on a Spacer Surface for $SF_6$ GIS ($SF_6$ GIS용 스페이서 표면에서의 파티클에 의한 절연파괴 특성연구)

  • Kim, Jae-Ho;Lee, Yong-Gil;Kim, Dong-Eui;Lee, Sae-Hun;Kim, Jung-Dal
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1536-1539
    • /
    • 1994
  • The influence due to metallic particle contaminated on spacer surface is remarkable in the decreasing of dielectric strength in $SF_6$ GIS. In relation with this problem, We studied, AC flash-over voltage characteristics and breakdown mechanism are investigated under metallic particle initiated condition in $SF_6$ gas by varying the particle position, particle shape with a plane-plane electrode. The main results arc as follows 1. The small amount of the metallic particle in the gap do not make flash-over voltage to be influence, but the significant decrease of th flash-overed voltage is result in case of the big and long size of the metallic paraticle. 2. Influence of the flash-over voltage are lowest in the mid and are highest in the electrode of metallic particle position. 3. In case of the initiated metallie particle, The more the pressure are high, the more the recluced ratio of flash-over voltage are high. 4. The metallic particle shape which results in the reduced flash-over voltage forced the critical pressure to move in to the region of low pressure. 5. The existance of the metallic particle on the upper electrode side and high pressure make the decreasing ratio of flash-over voltage bigger than that of the ground side electrode.

  • PDF

A Study on Inertia Sensor System for Nano Electronic Device (나노전자소자로서의 관성센서 시스템에 관한 연구)

  • Lee, Jun-Ha
    • Journal of the Semiconductor & Display Technology
    • /
    • v.8 no.4
    • /
    • pp.21-24
    • /
    • 2009
  • We investigated a nanoscale inertia sensor based on telescoping carbon nanotubes, using classical molecular dynamics simulations. The position of the telescoping nanotubes is controlled by the centrifugal force exerted by the rotation platform, thus, position shifts are determined by the capacitance between carbon nanotubes and the electrode, and the operating frequency of the carbon nanotube oscillator. This measurement system, tracking oscillations of the carbon nanotube oscillator, can be used as the sensor for numerous types of devices, such as motion detectors, accelerometers and acoustic sensors.

  • PDF

A Study on the Characteristics of Four Electrode Bioimpedance Model using Dry Electrode (건식전극을 이용한 4 전극형 생체임피던스 모델 특성 연구)

  • Cho, Young Chang;Jeong, Jong Hyeong;Yun, Jeong-oh;Kim, Min Soo
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1122-1127
    • /
    • 2019
  • In this study, the bio-impedance of the human body is able to obtain a lot of information by monitoring the pathological and physiological conditions of clinical and biological tissues. The four electrode method system for biometrics measured the potential difference between two electrodes and the other two electrodes were used as electrodes for current flow. The newly developed dry gold electrode measured impedance from 1 Hz to 50 kHz and produced reproducible results. To verify the impedance measurement of the dry electrode, the pitting was performed using an equivalent circuit model of the bioelectrode skin, and the effectiveness was demonstrated through modeling. Fixed electrode types have a constant position of the electrodes attached during the measurement, so that a stable measurement can be obtained, thereby minimizing the error.

A Model Study for Electrical Resistivity Method Using Three-Point Electrode Array (Three-Point 전극(電極) 배열법(配列法)을 이용(利用)한 전기(電氣) 비저항탐사(比抵抗探査) 모형연구(模型硏究))

  • Min, Kyung Duck;Kim, Chong Mi
    • Economic and Environmental Geology
    • /
    • v.14 no.3
    • /
    • pp.111-122
    • /
    • 1981
  • This study is a model analysis for an effective application of the geophysical prospecting to the investigation of geological structures or useful resources, and the purpose of it is to research a property of the electrical resistivity prospecting, especially by using a Three-Point electrode array method. In using the Three-Point electrode array method, it is theoretically assumed to choose the infinite for a distance between the two current electrodes, however it is impossible in applying to the practical field prospecting. Therefore this study was conducted for determination and presentation of a minimum appropriate distance between the two current electrodes by making a study on prospecting effect in the variation of distance between both the electrodes. In case that the ratios of the distance between the two current electrodes to that between the two potential electrodes are respectively chosen for 40, 400, 5,000, the experimental data of this study showed that the minimum appropriate distance between the two current electrodes is forty times as much as that between two potential electrodes. In order to make clear a problem about prospecting depth which is essential to the data processing, it had been chosen equally to the distance between two potential electrodes. As a result of it, it was shown that the anomaly is appeared along the position of an assumed ore body. Consequently it was found out that the prospecting depth of the Three-Point electrode array method is the same as the distance between the two potential electrodes. From the model experiment on the sheeting ore body(or linear structure) of horizontal, dipping of $30^{\circ}$, $60^{\circ}$ and vertical on the basis of above experimental condition, it was found out that the position and dip of assumed ore body could be inferred from the aspects of the equiresistivity curve. In consequence of performing out the simultaneous Normal and Reversal electrode movement, it was shown that the electrode movement of the Reversal forms the anomaly more clearly than that of Normal when the sheeting ore body is situated obliquely, therefore it could be ascertained that the electrode movement have to be performed simultaneously in the manner of Normal and Reversal. It was also exhibited that the aspect of the equiresistivity curve forms symmetrically when an assumed ore body (or linear structure) is situated horizontally or vertically, that is, symmetrically, and moreover that the aspect of the equiresistivity curve forms unsymmetrically when an assumed ore body (or linear structure) is situated obliquely. On the basis of these experimental analysis it is thought that it can be inferred from the aspect of equiresistivity curve whether an assumed ore body is obliquely situated or not.

  • PDF

A Study on the Addressing speed and Luminous Efficiency as Positions of Bus Electrodes in ac PDP (ac-PDP의 상판 Bus 전극 위치 변화에 따른 addressing 속도 및 발광효율에 관한 연구)

  • Kim, Yun-Gi;Lee, Sung-Hyun;Moon, Young-Seop;Kim, Gyu-Seop;Cho, Jung-Soo;Park, Chung-Hoo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.112-116
    • /
    • 2000
  • In this paper, we investigated the relationship between the position of bus electrode and address time, luminance and luminous efficiency in ac PDP of 50in. XGA resolution. When the bus electrode was placed in which was about $140{\mu}m$ apart from discharge gap, the luminous efficiency was the highest and address time was the least. Whereas, when the bus electrode was placed in the edge of ITO, the luminance was the highest.

  • PDF

Analysis of Electroencephalogram Electrode Position and Spectral Feature for Emotion Recognition (정서 인지를 위한 뇌파 전극 위치 및 주파수 특징 분석)

  • Chung, Seong-Youb;Yoon, Hyun-Joong
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.35 no.2
    • /
    • pp.64-70
    • /
    • 2012
  • This paper presents a statistical analysis method for the selection of electroencephalogram (EEG) electrode positions and spectral features to recognize emotion, where emotional valence and arousal are classified into three and two levels, respectively. Ten experiments for a subject were performed under three categorized IAPS (International Affective Picture System) pictures, i.e., high valence and high arousal, medium valence and low arousal, and low valence and high arousal. The electroencephalogram was recorded from 12 sites according to the international 10~20 system referenced to Cz. The statistical analysis approach using ANOVA with Tukey's HSD is employed to identify statistically significant EEG electrode positions and spectral features in the emotion recognition.

동전기 기법과 Zeolite를 이용한 중금속 오염토의 고정화에 관한 연구

  • 김종윤;김기년;김병일;김수삼
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.195-198
    • /
    • 2004
  • This study applied EK method to remediate contaminated soil by heavy metal(Pb), tried to increase the efficiency of remediation using zeolite as enhanced EK remediation method to overcome the limit of traditional EK remediation method. Adsorption tests on Pb were conducted to apply the EK extraction and test conditions which contained the electrode reversal, operating time were established. After tests, lead-ions were transported into the specific position of zeolite by EK phenomena, then the immobilization of lead-ions at zeolite was developed. Based on these tests, the efficiency of remediation is different with its test conditions. In addition, the efficiency of remediation was improved dramatically by adding zeolite without electrode reversal and satisfied TCLP regulation of EPA in USA through the whole sample range. Finally, absorption and immobilization capacity of zeolite were proved its excellence and confirmed the possibility of application as enhanced EK remediation method.

  • PDF

Improvement of the performance of EOC Amp in AOC method using microprocessor (마이크로프로세서를 이용한 AOC 방식에서 EOG 앰프 성능 개선)

  • 고석남;이상세;정호춘;임승관;이영석;진달복;박병림
    • Proceedings of the IEEK Conference
    • /
    • 2000.06e
    • /
    • pp.218-221
    • /
    • 2000
  • The electronystagmography(ENG) means to measure and record CRP(Corneal-Retinal Potential) whenever the eyeball is moved by using a skin electrode stuck to the hi-temporal and the difference of CRP. Both the horizontal and vertical movement are known according to the position of the stuck skin electrode. In this paper, the variable time-constances to record the eyeball signal of the conventional EOG(Electro-Oculograph) Amplifier is chosen. The shorter the time-constance is, the worse the distortion of a signal is. But the unbalanced impedance of the electrode stuck on the hi-temporal is reduced. Also, the longer the time-constance is, the less the distortion of it signal is. But it is sensitive to the change of base line according to the unbalanced impedance. In order to solve these problems, an DC-Amplifier, the distortion of the eyeball signal is globally used. By solving unbalanced impedance problem of EOG amplifier, the distortion ratio of EOG amplifier is improved.

  • PDF

A study on the Potential Detection System of Gas Insulated Switchgear (가스절연개폐장치의 전위감지 시스템에 대한 연구)

  • Choi, Seung-Kil;Baek, Seung-Kook;Kim, Kwang-Ho;Kang, Hyung-Boo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2284-2286
    • /
    • 1999
  • This paper describes the development of potential detection system in 22.9kV gas insulated switchgear. This system composed with main system and LPS can detect the source voltage by capacitive potential division which is accomplished by inserting signal electrode between main electrode and earthed metal enclosure of the switchgear. The appropriate position of signal electrode is achieved by numerical analysis using finite element method. The developed potential detection system is verified by several tests such as voltage test, swc test and others and by applicaion at site. From the results, it is concluded that potential detection system is very reliable and available to operate the switchgear safely.

  • PDF