• Title/Summary/Keyword: Electrode position

Search Result 211, Processing Time 0.028 seconds

Analysis of Lower Leg Movement Using Bio-impedance Technique (바이오 임피던스를 이용한 하지 운동분석)

  • Song, C.G.;Song, C.H.;Lee, M.G.;Kim, S.C.;Kim, J.C.;Seo, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.414-417
    • /
    • 2002
  • This paper describes the possibility of analyzing gait pattern from the variation of the lower leg electrical impedance. This impedance is measured by the four-electrode method. Two current electrodes are applied to the thigh and foot., and two potential electrodes are applied to the lateral aspect, medial aspect, and posterior position of lower leg. We found the optimal electrode position for knee and ankle joint movements based on high correlation coefficient, least interference, and maximum magnitude of impedance change. From such features of the lower leg impedance, it has been made clear that different movement patterns exhibit different impedance patterns and impedance level.

  • PDF

Fabrication of vertical Hall sensor for detecting three phases magnetic field (3상의 자계 검출을 위한 수직 Hall 센서의 제작)

  • Lee, Ji-Yeon;Nam, Tae-Chul
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.85-90
    • /
    • 2005
  • In this study, we have fabricated a three branches vertical Hall sensor for detecting three phases rotation informations of miniaturized brushless motor. The sensor gives three position signals phase shifted by $120^{\circ}$, corresponding to the motor driving signals. The branch has one Hall output and one input each other. The central part acts as common driving input. Sensor has branch width of $150{\mu}m$ and distance from central electrode to Hall electrode of $100{\mu}m$. The sensitivity of sensor is 250 V/$A{\cdot}T$ at magnetic field of 0.1 T. It has also showed three sine waves of Hall voltages with $120^{\circ}$ phase over a $360^{\circ}$ rotation. A packaged sensing part are $2{\times}2mm^{2}$ and has been successfully tested on a motor rotation at a speed up to 60,000 rpm.

Analysis of leg movements using bioimpedance bignal (bioimpedance 신호를 이용한 하지동작 분석)

  • Song, C.C.;Youn, D.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.940-942
    • /
    • 2003
  • This paper describes the possibility of analyzing gait pattern from the variation of the lower leg electrical impedance. This impedance is measured by the four-electrode method. Two current electrodes are applied to the thigh and foot, and two potential electrodes are applied to the lateral aspect, medial aspect, and posterior position of lower leg. We found the optimal electrode position for knee and ankle joint movements based on high correlation coefficient, least interference, and maximum magnitude of impedance change. From such features of the lower leg impedance, it has been made clear that different movement patterns exhibit different impedance patterns and impedance level.

  • PDF

Positional correction of a 3D position-sensitive virtual Frisch-grid CZT detector for gamma spectroscopy and imaging based on a theoretical assumption

  • Younghak Kim ;Kichang Shin ;Aleksey Bolotnikov;Wonho Lee
    • Nuclear Engineering and Technology
    • /
    • v.55 no.5
    • /
    • pp.1718-1733
    • /
    • 2023
  • The virtual Frisch-grid method for room-temperature radiation detectors has been widely used because of its simplicity and high performance. Recently, side electrodes were separately attached to each surface of the detectors instead of covering the entire detector surface with a single electrode. The side-electrode structure enables the measurement of the three-dimensional (3D) gamma-ray interaction in the detector. The positional information of the interaction can then be utilized to precisely calibrate the response of the detector for gamma-ray spectroscopy and imaging. In this study, we developed a 3D position-sensitive 5 × 5 × 12 mm3 cadmium-zinc-telluride (CZT) detector and applied a flattening method to correct detector responses. Collimated gamma-rays incident on the surface of the detector were scanned to evaluate the positional accuracy of the detection system. Positional distributions of the radiation interactions with the detector were imaged for quantitative and qualitative evaluation. The energy spectra of various radioisotopes were measured and improved by the detector response calibration according to the calculated positional information. The energy spectra ranged from 59.5 keV (emitted by 241Am) to 1332 keV (emitted by 60Co). The best energy resolution was 1.06% at 662 keV when the CZT detector was voxelized to 20 × 20 × 10.

Precipitation Characteristics with the Relative Position of the Ionizer in a Two-stage Electrostatic Precipitator (이단식 전기 집진 장치에서 하전부의 상대 위치 변화에 따른 집진 특성)

  • Lim, Hun-Chan;Lee, Duck-Chool
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.35T no.2
    • /
    • pp.66-71
    • /
    • 1998
  • A compact ESP of two-stage type is widely used with positive corona discharge in working environment where the production of ozone is extreamly prohibited. Since there are few scientific reports on a compact ESP, we have investigated the fundamental characteristics of a two-stage ESP. A model two-stage ESP is made with simple structure in order to simplify theoretical analysis and the relative position of the ionizer and collector section can be changed. The experimental investigation revealed many interesting facts.: The electric field in the collector electrodes affects the corona discharge of the ionizer. The concentration of particles after collector remarkably varied in the region between the high voltage and grounded electrodes. The collection efficiency right behind the high voltage electrode is much greater than that behind the grounded one. The total collection efficiency, calculated by integrating the particle concentration in whole measuring region, is greater when the high voltage electrode of the collector is located behind the discharge electrode of ionizer. Thus, the relative position of the ionizer and collector electrodes affects the precipitation characteristics.

  • PDF

Implementation of Wearable Heart Activity Monitoring System having Modified Bipolar Electrode and Correlation Analysis with Clinical Electrocardiograph(ECG) (수정된 바이폴라 전극을 갖는 착용형 심장활동 모니터링 시스템 구현 및 임상 심전도와의 상관관계 분석)

  • Lee, Kang-Hwi;Lee, Jeong-Whan;Lee, Young-Jae;Kim, Kyeong-Seop;Yang, Heui-Koung;Shin, Kun-Su;Lee, Myoung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.6
    • /
    • pp.1102-1108
    • /
    • 2008
  • Wearable physiological signal monitoring systems are regarded as an important sensing unit platforms in ubiquitous/mobile healthcare application. In this paper, we suggested the modified bipolar electrodes implemented on the portable heart activity monitoring system, which minimized the distance of electrodes formed on a attachable pad. The proposed electrode configuration is useful in mobile measurement environments, but has a disadvantage of reduced amplitude of the heart action potential. In order to overcome the shortcoming of the suggested electrode configuration, we implemented the amplifying circuit to increase the signal-gain and decrease the artifacts. For evaluations, we analyzed the specificity of measured cardiography using the proposed electrodes through the comparing of heart activity monitoring system with standard clinical ECG(lead2) by pearson correlation coefficients. The result showed that the average correlation coefficient is $0.903{\pm}0.036,\;0.873{\pm}0.072$ at V3, V4 chest lead position, respectively. Thus, the modified bipolar electrode is quite suitable to monitor the electrical activity of the heart in the situation of the mobile environment, and could be considered having high similarity with standard clinical ECG.

A Microcatuator for High-Density Hard Disk Drive Using Skewed Electrode Arrays (경사 전극 배열을 이용한 고밀도 하드 디스크의 마이크로 구동부 제작)

  • Choi, Seok-Moon;Park, Sung-Jun
    • Journal of Institute of Convergence Technology
    • /
    • v.1 no.2
    • /
    • pp.6-15
    • /
    • 2011
  • This paper reports the design and fabrication of a micro-electro-mechanical-system(MEMS)-based electrostatic angular microactuator for a dual-stage servo. The proposed actuator employs a novel electrode pattern named "skewed electrode array(SEA)" scheme. It is shown that SEA has better linearity than a parallel plate type actuator and stronger force than a comb-drive based actuator. The moving and the fixed electrodes are arranged to make the driving force perpendicular to the rotating moment of arm. By changing the electrode overlap length, the magnitude of electrostatic force and stable displacement will be changed. In order to optimize the design, an electrostatic FE analysis was carried out and an empirical force model was established for SEA. A new assembly method which will allow the active electrodes to be located beneath the slider was developed. The active electrodes are connected by inner and outer rings lifted on the base substrate, and the inner and outer rings are connected to platform on which the slider locates. Electrostatic force between active electrodes and platform can be used for exiting out of plane modes, so this provides the possibility of the flying height control. A microactuator that can position the pico-slider over ${\pm}0.5{\mu}m$ using under 20 volts for a 2 kHz fine-tracking servo was designed and fabricated using SoG process.

  • PDF

Automated external defibrillator electrode pad placement by the general public and health-care providers : A manikin study (일반인 및 의료종사자들의 자동제세동기를 이용한 제세동에서 전극부착 위치에 관한 연구: 마네킨을 이용한 연구)

  • Park, Si-Eun
    • The Korean Journal of Emergency Medical Services
    • /
    • v.20 no.1
    • /
    • pp.83-94
    • /
    • 2016
  • Purpose: This study aimed to assess defibrillator pad positioning by the general public and healthcare providers during basic life support (BLS) renewal education (RE). Methods: A total 130 subjects performed defibrillation using an automated external defibrillator (AED) equipped with electrode pads developed by the researchers and male resuscitation manikins, in order to assess electrode pad placement (EPP) before BLS RE. Subjects included 54 Healthcare providers (HP) and 76 members of the general public (GP). Results: The apex EPP was positioned in the risk area (RA), more than 5 cm distant from the area recommended, by 63.2% of the GP (n = 48). The apex EPP was positioned in the RA by 44.4% of the HP (n = 23). The distance from the apex (GP $5.27{\pm}2.21cm$, HP $4.18{\pm}1.71cm$) was statistically significant, using Student's t-test. Conclusion: For both GP and HP, apex EPP was significantly in error. Thus, to prevent defibrillation failures, EPP education and practice for GP and HP in all BLS education programs should be improved, and incorrect Korean cardiopulmonary resuscitation guidelines and related literature should be revised and corrected.

Study on single gap transflective fringe-fields switching liquid crystal display using the liquid crystal with negative dielectric anisotropy (유전율 이방성이 음인 액정을 이용한 FFS 모드의 단일 갭형 반투과형 액정 디스플레이 연구)

  • Kim, Jin-Ho;Chin, Mi-Hyung;Lim, Young-Jin;Lee, Seung-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.312-313
    • /
    • 2008
  • A transflective liquid crystal displays associated with fringe field switching (FFS) mode of new concept is proposed. The device utilizes unique characteristic of the FFS mode in which the rotation angle of LC director is strongly dependent on electrode position in on state. We use the liquid crystal with negative dielectric anisotropy. Also we are look for optimized electrode size and the optimization of pixel electrode width and distance between them, the LC director could rotate about $22.5^{\circ}$ and $45^{\circ}$ depending on electrode positions. Consequently, we get high transmittance and high reflection on the optimized electrode condition. Respectively, a high image quality transflective display with single gap and single gamma characteristics realized.

  • PDF

Design & implementation of differential sensor using electrostatic capacitance method for detecting Ringer's solution exhaustion (링거액 소진 감지를 위한 정전용량방식의 차동센서 설계 및 제작)

  • Sim, Yo-Sub;Kim, Cheong-Worl
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.391-397
    • /
    • 2010
  • This paper proposes a differential structure sensor for detecting Ringer's solution exhaustion, in which three C-type electrodes of 10 mm width are disposed on a ringer hose at a distance of 5 mm each other in the direction of Ringer's solution flow. In the center of middle electrode, two capacitances are formed at the proposed sensor. When ringer hose is filled with Ringer's solution, there is no difference between two capacitances. But capacitance difference exist under the Ringer's solution shortage, because the shortage causes the hose filled with air from the top position electrode. The capacitance difference got to maximum 1.81 pF, when air was filled between top and middle electrode and the last of hose was filled with 10 % dextrose injection Ringer's solution. The capacitance difference varied with hose-wraparound coverage of electrodes as well as the width of them. For hose-wraparound electrode coverage of 90 % and 70 %, the maximum capacitance difference was 1.81 pF and 1.56 pF, respectively. A differential charge amplifier converted the capacitance difference to electric signal, and minimized electrodes' adhering problem and external noise coupling problem.