• 제목/요약/키워드: Electrode position

검색결과 211건 처리시간 0.013초

전극위치에 따른 전기장 내 프로판 예혼합 화염의 특성 (Characteristics of Premixed Propane Flame in Electric Field according to Electrode Position)

  • 김태훈;김민석;김혜민
    • 한국분무공학회지
    • /
    • 제28권3호
    • /
    • pp.134-142
    • /
    • 2023
  • Electric field assisted combustion is a method that reduces instability in lean combustion. In this study investigated the effects of electrode position on propane-air flame characteristic using a ring electrode. Results showed that burning velocity was not affected by electrode position, but positive voltage expanded the flammability limit while negative voltage contracted it. The effect of voltage polarity on the flammability limit decreased as the electrode position increased. Expanding the flammability limit with a positive voltage can reduce NOx emissions.

진공인터럽터 극간 랩거리 조정에 따른 각 부위의 전계값 계산을 통한 진공인터럽터 내부 절연파괴부위 예측 (Estimate of Flashover Position from E-field Calculation along Electrode Gap Distance)

  • 윤재훈;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 춘계학술대회 논문집
    • /
    • pp.23-23
    • /
    • 2010
  • Because of power consumption increase, global warming, and limitation of installation, not only high reliability and interruption capability but also compact and light power apparatuses are needed. In this paper, various models that short and long gap distance were used to analyze E field of each model. Calculation value was estimated of flashover position. As a result, short and long gap distance that vacuum interrupter inner between move electrode and fix electrode not coincided flashover position of each model. short gap distance estimated flashover position at electrode edge. but long gap distance model confirmed $E_{max}$ value at center shield. in this paper was compared electric field value. and estimated of flashover position from electric field calculation.

  • PDF

Apparatus for determining the angular position, speed and/or direction of rotary objects

  • Lim, J.T.;Choi, D.H.;Lee, H.J.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1986년도 한국자동제어학술회의논문집; 한국과학기술대학, 충남; 17-18 Oct. 1986
    • /
    • pp.596-600
    • /
    • 1986
  • This paper describes a capacitively reading apparatus for determining the angular orientation, speed and/or direction of rotary objects such as shaft, dial hand, counter wheel and the like. The apparatus consists of sensing device and circuit accompanying with said sensing device. The sensing device is provided by arranging many stationary electrodes lying substantially on a surface of a stationary plane member and by arranging rotary electrode lying substantially on a surface of rotary objects to be monitored, in which said rotary electrode is in confronting relationship to some stationary electrodes so as to construct unique capacitors according to the angular position of rotary objects. The angular position of said rotary electrode is determined by sets of stationary electrodes which are in confronting relationship to rotary electrode. A carrier signal is generated by scanning device while scanning said stationarelectrodes, whose periods are in corresponding relationship to said stationary electrodes, respectively. The periods of carrier corresponding to the angular position of said rotary electrode is modulated by a modulation signal generated by detecting device according to said rotary electrode. This apparatus is applied to automatically monitor any kind of storage tank, as well as to automatically read the conventional utility meters such as Watthour meters, Gas meters, Water meters, etc..

  • PDF

복합근육활동전위의 시작잠복기와 진폭에 대한 기준전극의 영향 (The Influence of the Reference Electrode on Compound Muscle Action Potential Onset Latency and Amplitude)

  • 이상무;손종희;최휘철
    • Annals of Clinical Neurophysiology
    • /
    • 제12권1호
    • /
    • pp.11-15
    • /
    • 2010
  • Background: In belly-tendon (bipolar) montage, reference (R2) electrode placed on muscle's tendon has traditionally been considered to be electrically inactive. However, recent studies have revealed that R2 electrode is not simply referential, but actively contributes to compound muscle action potential (CMAP) waveform morphology. These findings suggest that CMAP onset latency and amplitude may also be influenced by the position of R2 electrode. This study was performed in order to evaluate the effect of R2 electrode position on CMAP onset latency and amplitude. Methods: We performed motor nerve conduction studies of median, ulnar, tibial and peroneal nerves on bilateral limbs of 20 normal subjects. We used traditional bipolar and monopolar montage and compared their CMAP onset latencies and amplitudes. In bipolar montage, recording (R1) electrode was placed on mid-belly of muscle with R2 electrode on the tendon of the muscle. In monopolar montage, R1 electrode was placed on the same site of bipolar montage, while R2 electrode was placed on the contralateral limb. Results: The mean CMAP onset latencies of median and peroneal nerves in bipolar montage were significantly different (p<0.05) with those in monopolar montage. And those of ulnar and tibial nerves were not significantly different (p>0.05). The mean CMAP amplitudes of all the tested nerves except ulnar nerve were significantly different (p<0.05). Conclusions: This study shows that change in R2 electrode position can affect the CMAP onset latency and amplitude, and these differences seem to be related to the generation of far field potential by CMAP.

상지 복합부위통증증후군 I형 환자에서 시행한 8극 척수자극술 - 증례보고 - (Cervical Spinal Cord Stimulation Using an 8 Electrode Lead in a Patient with Complex Regional Pain Syndrome Type I - A case report -)

  • 김용철;김성현;조지연;홍지희
    • The Korean Journal of Pain
    • /
    • 제20권2호
    • /
    • pp.186-189
    • /
    • 2007
  • The most important factors for successful stimulation of the spinal cord are strict patient selection and proper lead position. To ensure proper lead position, paresthesia produced by the stimulator should cover all of the areas in which pain is occurring. Until recently, only the quadripolar electrode lead has been used in for spinal cord stimulation in Korea, however, the 8 electrode lead was recently introduced to offer greater programming options and enhance the precision with which paresthesias is delivered to the desired sites. In addition, because the 8-electrode lead has a longer electrode span, it provides greater dermatomal coverage of up to 2 vertebral segments. Furthermore, the 8-electrode lead allows electronic repositioning of the stimulation to accommodate changing pain patterns, thereby reducing the need for lead revisions due to lead migration. Here, we present a case in which complex regional pain syndrome type I was successfully managed using an 8-electrode lead to induce spinal cord stimulation.

산화물을 첨가한 Ag-Pd 전극의 제조 (Synthesis of Ag-Pd Electrode having Oxide Additive)

  • 이재석;이동윤;송재성;김명호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.735-738
    • /
    • 2003
  • Downsizing electronics requires precision position control with an accuracy of sub-micron order, which demands development of ultra-fine displacive devices. Piezoelectric transducer is one of devices transferring electric field energy into mechanical energy and being capable for fine displacement control. The transducer has been widely used as fine Position control device Multilayer piezoelectric actuator, one of typical piezo-transducer, is fabricated by stacking alternatively ceramic and electrode layers several hundred times followed by cofiring process. Electrode material should be tolerable in the firing process maintaining at ceramic-sintering temperatures up to $1100{\sim}1300^{\circ}C$. Ag-Pd can be used as stable electrode material in heat treatment above $960^{\circ}C$. Besides, adding small quantity ceramic powder allow the actuator to be fabricated in a good shape by diminishing shrinkage difference between ceramic and electrode layers, resulting in avoidance of crack and delamination at and/or nearby interface between ceramic an electrode layers. This study presents synthesis of nano-oxide-added Ag/Pd powders and its feasibility to candidate material tolerable at high temperature. The powders were formed in a co-precipitation process of Ag and Pd in nano-oxide-dispersed solution where Ag and Pd precursors are melted in $HNO_3$ acid.

  • PDF

유한요소법에 의한 적층형 세라믹 히터의 전극 패턴 최적화 (Optimization of Electrode Pattern for Multilayer Ceramic Heater by Finite Element Method)

  • 한윤수;김시연;여동훈
    • 한국전기전자재료학회논문지
    • /
    • 제30권12호
    • /
    • pp.776-781
    • /
    • 2017
  • In this study, we investigated the effect of electrode pattern design on the thermal shock resistance and temperature uniformity of a ceramic heater. A cordierite substrate with a low thermal expansion coefficient was fabricated by tape casting, and a tungsten electrode was printed and used as a heating element. The temperature distribution of the ceramic heater was calculated by a finite-element method (FEM) by considering various electrode patterns, and the tensile stress distribution due to the thermal stress was calculated. In the electrode pattern with a single-line width, the central part of the ceramic heater was heated to the maximum temperature, and the position of the ceramic heater having a double-line width was changed to the maximum temperature, depending on the position of the minimum line width pattern. The highest tensile stress was found along the edges of the ceramic heater. The temperature gradient at the edge determined the tensile stress intensity. The smallest tensile stress was observed for electrode pattern D, which was expected to be advantageous in resisting thermal shock failures in ceramic heaters.

국제적인 10~20 전극시스템의 실용적인 방법에 관한 연구 (Study of Practical Method for International 10~20 Electrode System)

  • 김성희;이옥경;김대진
    • 대한임상검사과학회지
    • /
    • 제53권1호
    • /
    • pp.60-67
    • /
    • 2021
  • 뇌파검사는 뇌전증의 진단과 뇌 기능을 검사하는 것으로 이용된다. 임상병리사는 뇌파검뇌파 시행할 때 International 10~20 electrode system에 따라 정확하게 전극을 부착하고 인공산물 없이 의사들이 정확한 판독을 할 수 있게 뇌파를 기록하는 업무를 담당한다. 이러한 뇌파검사를 시행하는 임상병리사를 양성하기 위해 대학의 교육과정에서 실습시간을 통해 실무능력을 배양하게 되는데, 뇌파검사의 경우 정확한 전극 부착위치를 찾는 것이 학생들의 애로사항이었다. 본 연구에서는 전극부착위치를 쉽고 신속하게 찾아 학생들의 애로사항을 해결하기 위해 위치밴드를 제작하여 교과서에 기재된 줄자법과 전극 부착위치 찾는 방법을 비교하였다. 그 결과 피검자의 자세(앉은 자세 vs 누운 자세)에 따라 밴드법은 (196.7±61.8초 vs 200.2±49.3초), 줄자법은 (1281.0±457.4초 vs 1417.9±482.3초)로 앉은 자세일 때는 1084.3초(18.1분), 누운 자세일때는 1217.7초(20.3분)의 차이를 보여 줄자법보다 밴드법의 사용이 신속하다는 것을 확인하였다. 또한 전극 부착위치를 찾는데 영향을 줄 수 있는 교육과정 내의 뇌파 검사실습의 경험 유무와 피검자의 성별에 따른 차이에서도 밴드법은 줄자법보다 시간적인 차이가 적다는 것을 확인하였다. 본 연구에서 개발한 위치밴드를 사용한 줄자법을 사용하게 되면 대학의 교육과정에서 뇌파검사 실습시 애로사항이었던 전극 부착위치 찾는법을 신속하고 효율적으로 해결할 수 있다는 것을 확인하였고, 임상에서 신규 임상병리사들에게 교육하는데 적용도가 높을 것으로 사료된다. 다만 International 10~20 electrode system의 줄자법과 마찬가지로 전극 부착위치에 대한 정확성을 판정하는 기준에 대해서는 좀 더 연구가 필요할 것이다.

높은 위상지연값을 갖는 FFS mode에서 전극 위치에 따른 전기광학적 특성 연구 (Study on electro-optical characteristics of FFS mode with high $d{\Delta}n$ according to the electrode position)

  • 하경수;조은미;박지웅;김성수;정준호;김민수;김미영;이명훈;이승희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.310-311
    • /
    • 2008
  • We have studied electro-optical characteristics of fringe-field switching (FFS) mode with high $d{\Delta}n$ according to the electrode position. In this device, the fringe-electric field drives the LCs to rotate so that the dielectric torque is electrode-positional dependent, which results in electrode-position dependency in the LC's rotating angle. We confirmed polarization microscope image and chromaticity diagram at the different electrode position with LC that have high $d{\Delta}n$. Since the FFS mode is influenced by horizontal and vertical electric field, the FFS mode modulates light using both phase retardation and polarization rotation effect, which had already been verified with previous studies. However, from another point of view, tight modulation of FFS mode has been demonstrated by performing experiment and calculated simulation at the high $d{\Delta}n$ LC cell.

  • PDF

전기집전기 방전극 프레임 최적 설계 (Optimal Design of Discharge Electrode Frame in Electrostatic Precipitator)

  • 이후광;최재승;황석환;조창호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.626-629
    • /
    • 1997
  • In this study, position optimization of insulation rods and suspension rods in discharge electrode frame of electrostatic precipitator(EP) is performed using finite element analysis(FEA). The object of the optimization is to minimize the difference of altitudes in unevenly sagged horizontal structure and to regulate the size of materials within the allowable stress bounds. Uppermost horizontal channel of discharge electrode frame is highly stressed and uniformity of lowest horizontal angle depends on the position of rods. Ten types of frame are analyzed and one recommended model is presented.

  • PDF