• Title/Summary/Keyword: Electrode guide

Search Result 26, Processing Time 0.02 seconds

Cochlear Implant Failure in the Pediatric Population

  • Ozer, Fulya;Yavuz, Haluk;Yilmaz, Ismail;Ozluoglu, Levent N.
    • Journal of Audiology & Otology
    • /
    • v.25 no.4
    • /
    • pp.217-223
    • /
    • 2021
  • Background and Objectives: In cochlear implant (CI) surgery, the results and causes of revision and reimplantation may guide surgeons in establishing surgical protocols for revision surgery with safe audiological outcomes. The aim of this study was to review our experience in terms of etiology, surgical strategy, and hearing outcomes in pediatric patients who underwent CI removal and reimplantation. Subjects and Methods: All patients received implants of the same brand. Pre and postoperative Categories of Auditory Performance score and aided free-field pure tone audiometry thresholds were noted. In vivo integrity tests were performed for each patient and the results of ex vivo tests of each implant were obtained from manufacturer. Results: A total of 149 CIs were placed in 121 patients aged <18 years. The revision rate in children was 6.7% (10/121 children). Six patients had a history of head injury leading to a hard failure. The causes of reimplantation in others were soft failure (n=1), electrode migration (n=1), infection (n=1), and other (n=1). All patients showed better or similar postreimplantation audiological performance compared with pre-reimplantation results. Conclusions: It is very important to provide a safe school and home environment and educate the family for reducing reimplantation due to trauma. Especially for active children, psychiatric consultation should be continued postoperatively.

Cochlear Implant Failure in the Pediatric Population

  • Ozer, Fulya;Yavuz, Haluk;Yilmaz, Ismail;Ozluoglu, Levent N.
    • Korean Journal of Audiology
    • /
    • v.25 no.4
    • /
    • pp.217-223
    • /
    • 2021
  • Background and Objectives: In cochlear implant (CI) surgery, the results and causes of revision and reimplantation may guide surgeons in establishing surgical protocols for revision surgery with safe audiological outcomes. The aim of this study was to review our experience in terms of etiology, surgical strategy, and hearing outcomes in pediatric patients who underwent CI removal and reimplantation. Subjects and Methods: All patients received implants of the same brand. Pre and postoperative Categories of Auditory Performance score and aided free-field pure tone audiometry thresholds were noted. In vivo integrity tests were performed for each patient and the results of ex vivo tests of each implant were obtained from manufacturer. Results: A total of 149 CIs were placed in 121 patients aged <18 years. The revision rate in children was 6.7% (10/121 children). Six patients had a history of head injury leading to a hard failure. The causes of reimplantation in others were soft failure (n=1), electrode migration (n=1), infection (n=1), and other (n=1). All patients showed better or similar postreimplantation audiological performance compared with pre-reimplantation results. Conclusions: It is very important to provide a safe school and home environment and educate the family for reducing reimplantation due to trauma. Especially for active children, psychiatric consultation should be continued postoperatively.

Flash Lamp Annealing of Ag Organometallic Ink for High-Performance Flexible Electrode (플래시 기반 유기금속화합물 열처리를 통한 고성능 유연 전극 제조)

  • Yu Mi Woo;Dong Gyu Lee;Yun Sik Hwang;Jae Chan Heo;SeongMin Jeong;Yong Jun Cho;Kwi-Il Park;Jung Hwan Park
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.5
    • /
    • pp.454-462
    • /
    • 2023
  • Flash lamp annealing (FLA) of metal nanoparticle (NP) ink has provided powerful strategies to fabricate high-performance electrodes on a flexible substrate because of its rapid processing capability (in milliseconds), low-temperature process, and compatibility with to roll-to-roll process. However, metal NPs [e.g., gold (Au), silver (Ag), copper (Cu), etc.] have limitations such as difficulty in synthesizing fine metal NPs (diameter less than 10 nm), high price, and degradation during ink storage and FLA processing. In this regard, organometallic ink has been proposed as a material that can replace metal NPs due to their low-cost (usually 1/100 times cheaper than metal nano inks), low-temperature processability, and high material stability. Despite these advantages, the fabrication of flexible electrodes through FLA treatment of organometallic compounds has not been extensively researched. In this paper, we experimentally guide how to determine the optimal conditions for forming electrodes on flexible substrates by considering material parameters, and flashlight processing parameters (energy density, pulse duration, etc) to minimize the difficulties that may arise during the FLA of organometallic ink.

Double-Mode SAW Filter for Mobile Communication System (이중 모드 결합에 의한 이동 통신 기기용 SAW 필터)

  • 정영지;진익수;황금찬
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.4
    • /
    • pp.468-480
    • /
    • 1993
  • In this paper, at first, the characteristics of double mode SAW (DMS) resonator are analysed by applying the wave guide model and coupled mode theory to 1-port resonator. The DMS resonators (2-pole), which are arranged in a close, parallel configuration of two identical 1-port resonators on a single plate, and 4-pole DMS filters are designed and fabricated at the center frequency of 150.15 MHz with 3-dB bandwidth of 80 KHz. The empirical design characteristics are obtained from the comparison of experimental and theoretical values resulted from several fabrications, and the narrow bandpass filters are implemented on the basis of the above empirical results, which can be used to mobile communication systems. A ST-cut quartz substrate is selected for the stable temperature-frequence characteristics, and high resolution photolithography is applied to the fabrication of filter to get the fine electrode patterns.

  • PDF

A Study on Mechanical Properties of SM490-TMC Back Plate(40 mm) Steel by SAW Welding (SM490-TMC 후판(40 mm) 강재의 SAW 용접을 통한 기계적 특성 연구)

  • Lee, Soung-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.3
    • /
    • pp.88-93
    • /
    • 2021
  • SAW (Submerged Arc Welding) is often used for ship construction or welding pressure vessels and involves spraying a flux in a powder form to a welding site to a certain thickness and continuously supplying electrode wires therein. This welding method enables high current welding up to 1,500 to 3,000 A. Arc efficiency is higher than 95% and the technique allows clean work as it creates less welding fume, which is composed of fine metal oxide particles, and the arc beam is not exposed. In this study, SM490C-TMC thick plates were heterogeneously welded by SAW. Mechanical properties of welds were measured, and welds were assessed macroscopically and for adhering magnetic particles. The following conclusions were drawn. Bending tests showed no spots exploded on sample surfaces or any other defect, and plastic deformation testing confirmed sufficient weld toughness. These results showed the 1F welding method has no shortcomings in terms of bending performance.

Study on Design of ZnO-Based Thin-Film Transistors With Optimal Mechanical Stability (ZnO 기반 박막트랜지스터의 기계적 안정성 확보에 관한 연구)

  • Lee, Deok-Kyu;Park, Kyung-Yea;Ahn, Jong-Hyun;Lee, Nae-Eung;Kim, Youn-Jea
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.1
    • /
    • pp.17-22
    • /
    • 2011
  • ZnO-based thin-film transistors (TFTs) have been fabricated and the mechanical characteristics of electric circuits, such as stress, strain, and deformation are analyzed by the finite element method (FEM). In this study, a mechanical-stability design guide for such systems is proposed; this design takes into account the stress and deformation of the bridge to estimate the stress distribution in an $SiO_2$ film with 0 to 5% stretched on 0.5-${\mu}m$-thick. The predicted buckle amplitude of $SiO_2$ bridges agrees well with experimental results within 0.5% error. The stress and strain at the contact point between bridges and a pad were measured in a previous structural analysis. These structural analysis suggest that the numerical measurement of deformation, SU-8 coating thickness for Neutral Mechanical Plane (NMP) and ITO electrode size on a dielectric layer was useful in enhancing the structural and electrical stabilities.