• 제목/요약/키워드: Electrode Tip

검색결과 171건 처리시간 0.027초

알루미늄 합금의 저항점용접에서의 열전 효과에 대한 연구 (A Study of Thermoelectric Effect in Resistance Spot Welding of Aluminium Alloy)

  • 한용섭
    • 한국자동차공학회논문집
    • /
    • 제6권5호
    • /
    • pp.10-19
    • /
    • 1998
  • The erosion of electrode in spot welding of aluminium alloy by direct current is dependent on the electric polarity. The positive electrode is much more eroded than the negative one. To explain this phenomenon, Peltier effect has been generally accepted as a unique theory. In this study Peltier effect was evaluated by calculations on the basis of some references and experiments. The difference of heat generated by Peltier effect on both electrode surfaces was, however, only 4% of total heat generated during wel- ding. Because of insufficient explanation, Kohler theory, which is mainly affected by thin oxide film, was introduced. A theoretical calculation showed 17% of the temperature difference between the positive and negative electrode, in case "surface voltage" resulted from oxide film was 30% of total contact voltage. This revealed that the erosion of electrode could be more affected by Kohler theory than effect.an effect.

  • PDF

관형 코로나 방전전극을 이용한 이온풍속의 최대화 (An Maximization of Ionic Wind Utilizing a Cylindrical Corona Electrode)

  • 정재승;문재덕
    • 전기학회논문지
    • /
    • 제59권12호
    • /
    • pp.2256-2261
    • /
    • 2010
  • A corona discharge system with needle point or wire type corona electrode has been well used as an ionic wind blower. The corona discharge system with a needle point electrode produces ions at lower applied voltage effectively. However, the corona discharge on the needle point electrode transits to the arc discharge at lower voltage, and it is hard to obtain the elevated electric field in the discharge airgap for enhancing the ion migration velocity due to the weak Coulomb force. A cylindrical corona electrode with sharp round tip is reported as one of effective corona electrode, because of its higher breakdown voltage than that of the needle electrode. A basic study, for the effectiveness of cylindrical electrode shape on the ionic wind generation, has been investigated to obtain an maximum wind velocity, which however is the final goal for the real field application of this kind ionic wind blower. In this paper, a parametric study for maximizing the ionic wind velocity utilizing the cylindrical corona electrode and a maximum ion wind velocity of 4.1 m/s were obtained, which is about 1.8 times higher than that of 2.3m/s obtained with the needle corona electrode from the velocity profile.

침전극 곡률반경에 따른 LLDPE/EVA의 교류트리 특성 (A Study on the AC Treeing Characteristics with Tip Radius of Needle Electrode in LLDPE/EVA)

  • 이재필;이충호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.476-480
    • /
    • 2003
  • Polyethylene used as insulating material of power cable is nonpolar and low dielectric loss polymer. But it has defects of tree generation and accumulation of space charge by an applied voltage resulting in the decreased life and performance. To solve these problems, mixed films with LLDPE and EVA that is similar to LLDPE at physical properties in case of low VA contents were made and tested due to the blend ratios of 80:20, 70:30, 60:40 and 50:50[wt%] respectively. We investigated AC electrical treeing characteristics to acquire the best mixture ratio and effect of the tip radius of needle electrode to develop excellent treeproof materials. The degree of crystallity calculated with XRD pattern is higher for pure LLDPE, 50:50 and 70:30. For DSC analysis, it is confirmed that the melting points of mixed specimens are lower than that of pure LLDPE and higher than pure EVA's. The shape of tree propagation showed that pure EVA was electrical tree shape of the branch type, pure LLDPE and blended specimens was able to confirm tree shape of the bush type. As the tip radius go up in the blend ratio 70:30 specimen, the tree inception voltage rise. Probably the reason is the relaxation of electric field in the specimen with bigger tip ratio. As the 6 specimens were applied AC 5[KV],7.5[KV],10[KV] respectively, tree growth length is far shorter in the specimen with blend ratio 70:30, 50:50 than in pure EVA and pure LLDPE specimen. Conclusively, it is confirmed that specimens of which blend ratio are 70:30 and 50:50 are good in electrical tree retardant characteristics, especially, 70:30 has lower dielectric loss than 50:50 and its mixture ratio is the best.

  • PDF

점용접 시 압흔 깊이 감소를 위한 절연팁 개발에 관한 연구 (A Study on the Development of Insulated Electrode Tip for Spot Welding to Reduce Indentation)

  • 서승일;장상길
    • Journal of Welding and Joining
    • /
    • 제21권1호
    • /
    • pp.42-47
    • /
    • 2003
  • Stainless rolling stocks are usually fabricated by spot welding process without painting. Indentation on the surface of the car body after spot welding injures the beauty of the stainless rolling stocks. In this study, insulated electrode tips to reduce the indentation are developed and applied to the actual spot welding works. The developed tips are composed of head, neck, hole for cooling water, body and resistance material. They provide large surface contact area with the base materials during spot welding and enhance the current density by necking. Experimental results using the developed tips show that small indentation and sufficient tensile shear strength is produced due to large contact area and enhanced current density.

Fabrication of Sputtered Gated Silicon Field Emitter Arrays with Low Gate Leakage Currents by Using Si Dry Etch

  • Cho, Eou Sik;Kwon, Sang Jik
    • Transactions on Electrical and Electronic Materials
    • /
    • 제14권1호
    • /
    • pp.28-31
    • /
    • 2013
  • A volcano shaped gated Si-FEA (silicon field emitter array) was simply fabricated using sputtering as a gate electrode deposition and lift-off for the removal of the oxide mask, respectively. Due to the limited step coverage of well-controlled sputtering and the high aspect ratio in Si dry etch caused by high RF power, it was possible to obtain Si FEAs with a stable volcano shaped gate structure and to realize the restriction of gate leakage current in field emission characteristics. For 100 tip arrays and 625 tip arrays, gate leakage currents were restricted to less than 1% of the anode current in spite of the volcano-shaped gate structure. It was also possible to keep the emitters stable without any failure between the Si cathode and gate electrode in field emission for a long time.

DLC-coated Si-tip FEA 제조에 있어서 기판 상에 경사-회전 증착된 Al 희생층을 이용한 Gate누설 전류의 감소 (Decrease of Gate Leakage Current by Employing Al Sacrificial Layer Deposited on a Tilted and Rotated Substrate in the DLC-coated Si-tip FEA Fabrication)

  • 주병권;김영조
    • 마이크로전자및패키징학회지
    • /
    • 제7권3호
    • /
    • pp.27-29
    • /
    • 2000
  • Lift-off를 이용한 DLC-coated Si-tip FEA 제조에 있어서 gate 절연막의 측면에 DLC가 coating되는 것을 방지하기 위해 기판 상에 Al 희생층을 경사-회전 증착한 뒤 DLC를 coating하고, 다음으로 희생층을 식각하여 tip 이외의 DLC를 제거하는 방법을 제안하였다. 이러한 Al희생층을 이용한 lift-off공정에 의해 제조된 DLC-coated Si-tip FEA의 전류전압 특성과 전류 표동 특성을 조사하였으며, gate 누설 전류의 감소와 방출 전류의 안정성을 확인하였다.

  • PDF

전극 형상에 따른 저비중 경량강판의 저항 점 용접 특성 (Resistance Spot Weldability of Low Density Lightweight Steel according to Electrode Shape)

  • 황인성;윤현상;김동철;강문진;김재도;김영민
    • Journal of Welding and Joining
    • /
    • 제35권2호
    • /
    • pp.52-57
    • /
    • 2017
  • In this study, resistance spot weldability of lightweight steel with high Al contents was evaluated using various electrode shapes. The six types of electrode shape were prepared with different electrode face diameter and radius. The tensile shear tests were carried out to investigate the failure behaviors. Also, the nugget size and hardness were measured and compared with various electrode shapes. The experimental results show that the acceptable weld current region for low density lightweight steel could be obtained with 10mm electrode face diameter and 76mm electrode face radius.

정위적 삼차신경절 고주파열응고술 (Stereotactic Radiofrequency Gasserian Ganglionotomy)

  • 신근만;신삼철;조용노;임소영;홍순용;최영룡
    • The Korean Journal of Pain
    • /
    • 제9권1호
    • /
    • pp.183-186
    • /
    • 1996
  • When medical therapy fail to relieve pain at tolerable level for patients confirmed with trigeminal neuralgia, presence of mass lesion excluded, surgery is indicated. Innumerable surgical strategies have been attempted for the treatment of trigeminal neuralgia but only four have proven appropriate: (1)stereotactic radiofrequency gasserian ganglionotomy, (2) percutaneous glycerol gangliolysis, (3) percutaneous microcompression, (4) microvascular decompression. Radiofrequency thermocoagulation of the gasserian ganglion stems from the efforts of Sweet. This technique is the surgical treatment of choice around the world for surgical treatment for trigeminal neuralgia. Since 1986, over 14,000 cases have been reported utilizing this technique. To improve the treatment method further, an electrode with a flexible curved tip has been developed for easier and more precise electrode placement and lesion production during the thermocoagulation of gasserian ganglion. This operation was performed recently on three patients at Hallym University Hospital. using a curved tip electrode. Complete relief of pain was achieved for all patient. However, some complications were noted.

  • PDF

Development of Nonthermal Bioplasma Source Applicable to Human Liquid Fluids

  • Min, Boo-Ki;Oh, Hyun-Joo;Song, Ki-Baek;Uhm, Han-Sup;Kang, Seung-Oun;Choi, Eun-Ha
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제41회 하계 정기 학술대회 초록집
    • /
    • pp.327-327
    • /
    • 2011
  • A nonthermal bioplasma source was developed for application to human liquid fluids by making use of nano-size tungsten tips. Characteristics of the plasma source are investigated. Here we have used the AC voltage system. The bioplasma source generated by a tungsten tip with quartz tube and ground electrode is a low-temperature plasma without making any noticeable damage to cells at a low power operation. The breakdown voltage and current signals are measured by high voltage probe (Tektronix P6015A) and current probe (P6021). Variation of breakdown temperature near the tip electrode is larger than that in the neighborhood of ground electrode. Bubble formation during discharge has been recorded and investigated by using the high speed camera. The existence and behavior of hydroxyl and superoxide radicals are detected and measured by spectrometers. The electrical and optical properties of breakdown characteristics are also investigated.

  • PDF