• Title/Summary/Keyword: Electrode Movement

Search Result 124, Processing Time 0.024 seconds

Oil Movement Control of Electrowetting Display with Patterned Electrode (전극 패턴을 이용한 Electrowetting display의 오일 제어)

  • Kim, Tae-Hyun;Kim, Yeon-Sik;Ashanulhaq, Q.;Jeong, Eun;Lee, Seung-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.04a
    • /
    • pp.47-48
    • /
    • 2006
  • Electrowetting phenomenon is applied in the various field of technology. One of that is electrowetting display as a paper like electronic paper. Fast response and easy to express a color is goodness. In spite of that, the oil movement of the electrowetting display is irregular. So it doesn't look like uniform. Because of the above reason, electrowetting display using patterned electrode is made and the characteristic of oil movement is observed. Electrode and polymer wall is patterned by photo-lithography. We analyze the oil movement according to the variation of size and the position of etched electrode area.

  • PDF

Optimal Electrode Selection for Detection of Human Leg Movement Using Bio-Impedance (생체 임피던스를 이용한 인체 하지운동 출을 위한 최적 전극위치 선정)

  • 송철규;윤대영;이동헌;김승찬;김덕원
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.8
    • /
    • pp.506-509
    • /
    • 2003
  • This paper describes the possibility of analyzing gait pattern from the changes of the lower leg electrical impedance. This impedance was measured by the four-electrode method. Two current electrodes were applied to the thigh, knee, and foot., and two potential electrodes were applied to the lateral, medial, and posterior position of human leg. The correlation coefficients of the joint angle and the impedance change from human leg movement was obtained using a electrogoniometer and 4ch impedance measurement system developed in this study. We found the optimal electrode position for knee and ankle joint movements based on high correlation coefficient, least interference, and maximum magnitude of impedance change. The correlation coefficients of the ankle, knee, and the hip movements were -0.913, 0.984 and 0.823, respectively. From such features of the human leg impedance, it has been made clear that different movement patterns exhibit different impedance patterns and impedance level. This system showed feasibility that lower leg movement could be easily measured by impedance measurement system with a few skin-electrodes.

Oil Movement Control by Charge Density Control in the Electrowetting Display (하전입자의 분포에 따른 Electrowetting display의 오일의 움직임)

  • Kim, Tae-Hyun;Kim, Yeon-Sik;Ashanulhaq, Q.;Jeong, Eun;Hahn, Yoon-Bong;Lee, Seung-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.495-496
    • /
    • 2006
  • Electrowetting phenomenon is applied in the various field of technology. One of that is electrowetting display as a paper like electronic paper. Fast response and easy to express a color is goodness. In spite of that, the oil movement of the electrowetting display is irregular. So it doesn't look like uniform. Because of above reason, electrowetting display using patterned electrode is made and the characteristic of oil movement is observed. Electrode and polymer wall is patterned by photo-lithography. We analyze the oil movement according to the variation of size and the position of etched electrode area.

  • PDF

Oil Movement of Electrowetting Display with Patterned Pixel Electrode (화소전극의 부분 식각을 통한 Electrowetting Display의 오일의 움직임)

  • Kim, Su-Young;Kim, Youn-Sik;Song, Eun-Gyoung;Sureshkumar, Palanivelu;Lee, Chan-Jae;Han, Jeong-In;Lee, Seung-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.286-287
    • /
    • 2006
  • Electrowetting display (EWD) is one of the strong candidates for electronic paper like display (EPD). However, in the conventional EWD, the oil movement occurs in random direction so that we can observe irregular distribution of contracted oil in the operation. To realize colorful display and achieve a fast response time, oil movement in the pixel should be directed in a specific direction. In this paper, we report the result of oil contraction with specified direction which is achieved by patterned electrode. From the experiments, we find that the oil movement depends on the portion of etched electrode area and study other influencing factors of patterned electrode on the oil movement.

  • PDF

Development and Assessment of Conductive Fabric Sensor for Evaluating Knee Movement using Bio-impedance Measurement Method (슬관절 운동 평가를 위한 생체 임피던스 측정용 전도성 섬유센서 개발 및 평가)

  • Lee, Byung-Woo;Lee, Chung-Keun;Cho, Ha-Kyung;Lee, Myoung-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.1
    • /
    • pp.37-44
    • /
    • 2011
  • This paper describes the development and assessment of conductive fabric sensor for evaluating knee movement using bio-impedance measurement method. The proposed strip-typed conductive fabric sensor is compared with a dot-typed Ag/AgCl electrode for evaluating validity under knee movement condition. Subjects are composed of ten males($26.6{\pm}2.591$) who have not had problems on their knee. The strip-typed conductive fabric sensor is analyzed by correlation and reliability between a dot-typed Ag/AgCl electrode and the strip-typed conductive fabric sensor. The difference of bio-impedance between a dot-typed Ag/AgCl electrode and the strip-typed conductive fabric sensor averages $7.067{\pm}13.987\;{\Omega}$ As the p-value is under 0.0001 in 99% of t-distribution, the strip-typed conductive fabric sensor is correlated with a dot-typed Ag/AgCl electrode by SPSS software. The strip-typed conductive fabric sensor has reliability when it is compared with a dot-typed Ag/AgCl electrode because most of bio-impedance values are in ${\pm}1.96$ standard deviation by Bland-Altman Analysis. As a result, the strip-typed conductive fabric sensor can be used for assessing knee movement through bio-impedance measurement method as a dot-typed Ag/AgCl electrode. Futhermore, the strip-typed conductive fabric sensor is available for wearable circumstances, applications and industries in the near future.

The Use of Artificial Neural Networks in the Monitoring of Spot Weld Quality (인공신경회로망을 이용한 저항 점용접의 품질감시)

  • 임태균;조형석;장희석
    • Journal of Welding and Joining
    • /
    • v.11 no.2
    • /
    • pp.27-41
    • /
    • 1993
  • The estimation of nugget sizes was attempted by utilizing the artificial neural networks method. Artificial neural networks is a highly simplified model of the biological nervous system. Artificial neural networks is composed of a large number of elemental processors connected like biological neurons. Although the elemental processors have only simple computation functions, because they are connected massively, they can describe any complex functional relationship between an input-output pair in an autonomous manner. The electrode head movement signal, which is a good indicator of corresponding nugget size was determined by measuring the each test specimen. The sampled electrode movement data and the corresponding nugget sizes were fed into the artificial neural networks as input-output pairs to train the networks. In the training phase for the networks, the artificial neural networks constructs a fuctional relationship between the input-output pairs autonomusly by adjusting the set of weights. In the production(estimation) phase when new inputs are sampled and presented, the artificial neural networks produces appropriate outputs(the estimates of the nugget size) based upon the transfer characteristics learned during the training mode. Experimental verification of the proposed estimation method using artificial neural networks was done by actual destructive testing of welds. The predicted result by the artifficial neural networks were found to be in a good agreement with the actual nugget size. The results are quite promising in that the real-time estimation of the invisible nugget size can be achieved by analyzing the process variable without any conventional destructive testing of welds.

  • PDF

Optimal Electrode Displacement for Motion Analysis using Bio-impedance (임피던스 방식의 동작분석을 위한 최적전극 선정)

  • 송철규;변용훈;윤대영;이명권;김거식;송창훈;김경섭;김수찬;김덕원
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2887-2890
    • /
    • 2003
  • This paper describes the possibility of analyzing gait pattern from the variation of the lower leg electrical impedance. This impedance is measured by the four-electrode method. Two current electrodes are applied to the thigh, knee, and foot, and two potential electrodes are applied to the lateral, medial, and posterior position of lower leg. The correlation coefficients of the joint angle and the impedance change from human leg movement was obtained using electrogoniometer and 4ch impedance measurement system developed in this study. We found the optimal electrode position for ankle, knee and hipjoint movements based on high correlation coefficient, least interference, and maximum magnitude of impedance change. The correlation coefficients of the ankle, knee, and the hip movements -0.87, 0.957 and 0.80. respectively. From such features of the lower leg impedance, it has been made clear that different movement patterns exhibit different impedance patterns and impedance level. This system showed possibility that lower leg movement could be easily measured by impedance measurement system with a few skin-electrodes.

  • PDF

Effect of Electrode Space on Optical Property in Three-Electrode Type E-paper Display (3전극형 전자종이 디스플레이에서 하부전극 간격이 패널의 광특성에 미치는 영향)

  • Lee, Sang-il;Hong, Youn-Chan;Kim, Young-cho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.4
    • /
    • pp.231-236
    • /
    • 2016
  • A three-electrode type reflective display (electronic paper) is designed to apply an independent electric field to each three electrodes of the cell including two electric-type of particles and electrically neutral color fluid, so single color realization is possible. In particular, the movement of particles and optical properties are decided by the electric field between two electrodes on the lower substrate. So, the effect of electric field by the distance between two electrodes on the lower substrate is studied with electrode spacing with $10{\mu}m$, $15{\mu}m$, $20{\mu}m$, and $25{\mu}m$. By our experimentation, the driving voltage induces more reliable movement of charged particles and the optical properties as compared with the threshold voltage. We ascertain the single color realization and non-inverted particle separation is possible. So the more desirable optical properties are observed in case of the short electrode like $10{\mu}m$.

Evaluation and Verification of Optimal Electrode Configurations for Detection of Arm Movement Using Bio-Impedance (생체임피던스에 의한 상지운동 감지를 위한 최적 전극 위치의 평가 및 검증)

  • Ahn, Seon-Hui;Kim, Soo-Chan;Nam, Ki-Chang;Kim, Deok-Won
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.399-402
    • /
    • 2002
  • In this study, we constructed a four-channel impedance measurement system including a two-channel goniometer to analyze human arm movement. Impedances and joint angles were simultaneously measured for wrist and elbow movements. As the impedance changes resulting from wrist and elbow movements depended heavily on electrode placement, we determined the optimal electrode configurations for those movements by searching for high correlation coefficients, large impedance changes, and minimum interferences in ten subjects (age: 29+6). Our optimal electrode configurations showed very strong relationships between the wrist joint angle and forearm impedance (correlation coefficient = 0.95+0.04), and between the elbow joint angle and upper arm impedance (correlation coefficient = -0.98+0.02). Although the measured impedances changes of the wrist (1.1+1.5 ohm) and elbow (-5.0+2.9 ohm) varied among individuals, the reproducibilities of wrist and elbow impedance changes of five subjects were 5.8+1.8 % and 4.6+1.4 % for the optimal electrode pairs, respectively. We propose that this optimal electrode configuration would be useful for future studies involving the measurement of accurate arm movements by impedance method.

  • PDF

Welding Quality Improvement of Inverter Spot Welder by Electrode Movement Control (전극분리 제어에 의한 인버터 스폿용접기의 용접품질 향상)

  • 김재문;김종덕;원충연;최규하;김규식;목형수
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.3
    • /
    • pp.276-284
    • /
    • 2000
  • 저항 스폿용접기에서 용접품질의 보증은 오래 계속 되어온 문제이었다. 본 논문에서는 용접품질과 전극분리와의 관계를 조사하였으며 전극분리가 하나의 제어변수로써 사용될 수 있음을 실험적으로 입증하였다. 피드백신호로서 전극분리를 이용한 퍼지제어에 기초를 둔 용접품질개선을 제시하였다. 저항 스폿용접기의 용접품질은 인장전단강도시험과 같은 파괴적인 검사에 의해 증명되었다. 시험결과는 퍼지 제어기를 이용한 전극분리 제어의 성능이 종래의 정전류 제어와 비교하여 훨씬 더 우수하였다.

  • PDF