• 제목/요약/키워드: Electrocautery dissection

검색결과 6건 처리시간 0.017초

Ultrasonic dissection versus electrocautery for immediate prosthetic breast reconstruction

  • Lee, Dongeun;Jung, Bok Ki;Roh, Tai Suk;Kim, Young Seok
    • Archives of Plastic Surgery
    • /
    • 제47권1호
    • /
    • pp.20-25
    • /
    • 2020
  • Background Ultrasonic dissection devices cause less thermal damage to the surrounding tissue than monopolar electrosurgical devices. We compared the effects of using an ultrasonic dissection device or an electrocautery device during prosthetic breast reconstruction on seroma development and short-term postoperative complications. Methods We retrospectively reviewed the medical records of patients who underwent implant-based reconstruction following mastectomy between March 2017 and September 2018. Mastectomy was performed by general surgeons and reconstruction by plastic surgeons. From March 2017 to January 2018, a monopolar electrosurgical device was used, and an ultrasonic dissection device was used thereafter. The other surgical methods were the same in both groups. Results The incidence of seroma was lower in the ultrasonic dissection device group than in the electrocautery group (11 [17.2%] vs. 18 [31.0%]; P=0.090). The duration of surgery, total drainage volume, duration of drainage, overall complication rate, surgical site infection rate, and flap necrosis rate were comparable between the groups. Multivariate analysis revealed that the risk of seroma development was significantly lower in the ultrasonic dissection device group than in the electrocautery group (odds ratio for electrocautery, 3.252; 95% confidence interval, 1.242-8.516; P=0.016). Conclusions The findings of this study suggest that the incidence of seroma can be reduced slightly by using an ultrasonic dissection device for prosthesis-based breast reconstruction. However, further randomized controlled studies are required to verify our results and to assess the cost-effectiveness of this technique.

내시경을 이용한 겨드랑절개 이중평면 유방확대술 (Endoscopic Transaxillary Dual Plane Breast Augmentation)

  • 심형보;위형곤;홍윤기
    • Archives of Plastic Surgery
    • /
    • 제35권5호
    • /
    • pp.545-552
    • /
    • 2008
  • Purpose: The transaxillary approach for breast augmentation has been advocated for patients and surgeons for several decades. However, this blind technique had many disadvantages including, traumatic dissection, difficult hemostasis, displacement of implants, and ill-defined asymmetrical location of inframammary crease. In the present study, the precise endoscopic electrocautery dissection was applied to eliminate the limits of blunt dissection throughout the procedures. Methods: From December 2006 to December 2007, a total of 103 patients with an average age of 29.5 years underwent endoscopic assisted transaxillary dual plane augmentation mammoplasty. The mean implant size was 243 cc with the range between 150 and 350 cc. Through a 4 cm axillary incision, electrocautery dissection for submuscular pockets was carried out under the endoscopic control. The costal origin of pectoralis muscle was completely divided to expose subcutaneous tissue and to make type I dual plane. Results: Using the endoscopic dissection, we achieved good aesthetic results including a short recovery period, less morbidity, and symmetrical well-defined inframammary crease. Type I dual plane procedure could support the consistent inframammary fold shape and be applied to most patients without breast ptosis. Minor complications did not occur, however, four major complications of capsular contracture occurred. Conclusion: In contrast to the era of the blind techniques, endoscopic assisted transaxillary dual plane breast augmentation can now be performed effectively and reproducibly. With Its advantage, the axillary application of endoscopy for augmentation mammaplasty is useful to achieve the optimal cosmetic outcomes.

Transaxillary Endoscopic Breast Augmentation

  • Sim, Hyung-Bo
    • Archives of Plastic Surgery
    • /
    • 제41권5호
    • /
    • pp.458-465
    • /
    • 2014
  • The axillary technique is the most popular approach to breast augmentation among Korean women. Transaxillary breast augmentation is now conducted with sharp electrocautery dissection under direct endoscopic vision throughout the entire process. The aims of this method are clear: both a bloodless pocket and a sharp non-traumatic dissection. Round textured or anatomical cohesive gel implants have been used to make predictable welldefined inframammary creases because textured surface implants demonstrated a better stability attributable to tissue adherence compared with smooth surface implants. The axillary endoscopic technique has greatly evolved, and now the surgical results are comparable to those with the inframammary approach. The author feels that this technique is an excellent choice for young patients with an indistinct or absent inframammary fold, who do not want a scar in the aesthetic unit of their chest.

Endoscopic transaxillary prepectoral conversion for submuscular breast implants

  • Park, Si-Hyun;Sim, Hyung-Bo
    • Archives of Plastic Surgery
    • /
    • 제45권2호
    • /
    • pp.158-164
    • /
    • 2018
  • Background During breast augmentation, the transaxillary approach provides the advantage of allowing the mammary prosthesis to be placed through incisions that are remote from the breast itself, thereby reducing the visibility of postoperative scars. For patients experiencing capsular contracture who do not want additional scars, the previous transaxillary scar can be used for site change and implant exchange. Methods This study analyzed 17 patients (34 breasts) with submuscular breast implants with grade III-IV capsular contracture who received treatment from 2010 to 2015. The mean age of the patients was 29 years (range, 20-38 years). The inclusion criterion was a pinch test of more than 3 cm at the upper pole of the breast. Previous axillary scars were used to expose the pectoralis fascia, and submuscular breast implants were removed carefully. The dissection underneath the pectoralis fascia was performed with endoscopic assistance, using electrocautery under direct visualization. Results The mean follow-up period was 14 months (range, 6-24 months). The entire dissection plane was changed from the submuscular plane to the subfascial plane. Round textured gel implants were used, with a mean implant size of 220 mL (range, 160-300 mL). Two patients developed grade II capsular contracture. There were no cases of malposition or asymmetry. Three patients complained of minor implant palpability. None of the patients required additional surgery. Conclusions Endoscopic subfascial conversion may be an effective technique for treating capsular contracture and avoiding scarring of the breast in selected patients.

변형된 쌈지봉합을 이용한 함몰 유두의 교정 (The Correction of Inverted Nipple Using Modified Purse-string Suture)

  • 오상하;우종설;이승렬;김재룡
    • Archives of Plastic Surgery
    • /
    • 제35권6호
    • /
    • pp.687-691
    • /
    • 2008
  • Purpose: An inverted nipple presents both cosmetic and functional problems. It is a source of repeated irritation and inflammation, and interferes with nursing. In addition, its abnormal appearance may cause psychological distress. With consideration of its underlying pathophysiologic components and severity, a number of techniques have been introduced for correction of this anomaly. The diversity of techniques indicates the lack of a good, sustainable, and durable solution for this quite common problem. We report our method as an alternative solution for correcting of the inverted nipple. Methods: From August 2003 to November 2007, 273 nipples in 147 patients were treated. 126 patients had bilateral inverted nipples. Patient age at the operation ranged from 21 to 63 years(mean age, 34 years). All nipples were congenital anomaly. 45 nipples were graded as grade I, 179 nipples as II, and 49 nipples as III. In the our study, we made some modification to the classic purse-string suture: (1) twice purse-string suture: (2) excision of diamond-shaped skin at the nipple neck: (3) buried suture of the breast parenchyma at the nipple base: (4) some timely release of retraction using Bovie's electrocautery dissection at inner surface of the nipple neck. Results: The operation time averaged 15 minutes. The mean follow-up period ranged from 3 to 48 months, with an average of 8.4 months. There were no complications associated with the surgery, such as infection, hematoma, permanent sensory disturbance, or total nipple necrosis except temporary sensory loss in 9 cases, partial nipple necrosis in 7 cases, and recurred inversion in 15 cases. All patients except recurred inversion were satisfied with their results. Conclusion: We believe that our modified purse-string suture is a reliable, simple, safe, and effective method for correcting the inverted nipple.

초기 상후두암종에서 레이저를 이용한 내시경하 상후두부분절제술의 적용 (Clinical Application of Endoscopic Laser Assisted Supraglottic Partial Laryngectomy in Early Supraglottic Cancer)

  • 최종욱;권기환;오준환;한승훈;이승훈;최건
    • 대한두경부종양학회지
    • /
    • 제14권2호
    • /
    • pp.164-168
    • /
    • 1998
  • 레이저를 이용한 내시경하 상후두부분절제술은 술전에 정확한 병기판정으로 초기 국소병변의 선택을 신중하게 하고 경부 림프절전이의 치료를 효율적으로 시행하는 경우 기존의 수술법과 유사한 생존율을 얻을 수 있었다. 환자의 상태에 따라서 충분한 수술시야를 확보하는데 어려움이 있으며, 병변의 위치에 따라서 술중 절제연의 확인이 힘들다는 제한점을 고려해야 하며, 술 후 발생할 수 있는 출혈, 부종, 오연 등의 합병증에 대비하기 위하여 술 전 기관절개술이 유용할 것으로 생각된다.

  • PDF